HomeMy WebLinkAbout3799-8ICement grout
d f
UJ
PI
<I
E:
UJ
of IV2 "xIV2 -xl/4
%JI Angle
V4
V
(/ 'Steel Plate
DETAIL -PLATE STIFFENER
8` 8.
Mtn Mn Conc. collar
C.S.P P ' ° R.C.P. m
,r
-- a- 17-
C%
_C m E
ALTERNATE JUNCTION
Tef on tape
2/2 "x2/2_ -x%"
Sti, bar (typ)
Scarf -.and '- __�
we - '�. M
L
% -x% " Spacer
Y2 " Allen bolt
HOLD-DOWN
Ring O.D.
q5 • (TYprn' places
Y2 - std. pipe or
mild steel bar
-x2- Wlde
C.S.P. O.D.
I
1�
Maa4tch atop plate
NOTES: BOTTOM VIEW
I. Riser pipe shall extend to "Elev. A". CAGE RETAINER RING
2. Elevation *A, DI , .D2 , LI , L2 ore shown on plans.
3. Corrugated steel pipe shall conform to AASHTO M-36.
4. Grate assembly shall be galvanized after fabrication.
5. For Dl =54" and larger, weld I%2 "x1Y2 "xl/4 " angles to plate with I"
welds at 6" O.C.
6. n=number of bars on grate assembly.
7. Gauge of pipe for diameter D2 shall be some as for riser.
B. Riser and stub shall be shop fabricated and galvanized after welding.
9. The following shall be stencilled using 2 inch high letters and black
paint on the face of the curb adjacent to the inlet (either side)
and on the Top .of the inlet:
NO DUMPING
DRAINS TO OCEAN
-
(See note 5)
''
'/4" Hole, "H.D.", See Stiffener
equally spaced Detail next page
Center of hole 1
to be I" from
O.D. of plate,
j
DTYpI
D, + s�
BOTTOM VIEW
TOP PLATE
See detail for
Locking Devices
Elev. A Grading at lip,
unless otherwise
shown on plan.
J
slope to
drain -
I Conc. slab
ELEVATION
� <n places
V2
Standard
galvanized
connection band.
C.S.P. _,R.C.P.
D, RISER
DIAMETER
C.S.P.
GAUGE
18"-27" 1
16
30"-39"
14
42"-48"
12
51"-66"
10
DI
A: 5 1. 0
n"
Hp'
18"
400
9
2
24"-27" 300 12
30"-33"
1 240
15
3
36"-39" 200 18
42"-45"
16.50
22
4
48"-51" 14.50 25
54"-57" 130 28
60"-6 3" 111.501 31
66" 10.5 ° 34
ry pack
ORANGE COUNTY ENVIRONMENTAL MANAGEMENT AGENCY STD. PLA" I •ORANGE COUNTY ENVIRONMENTAL MANAGEMENT AGENCY
Approved Approved.13
iY7
WL Zoun, Dlr or of Pr bllc Works f WL Zoun, D! for of Public Works
Adopted: Res. 77-92 Revlsed-. Res. 96-546 [/! Adopted: Res. 77-92 Revlsed: Res. 96-546
INLET TYPE V SH7.2 of 2 INLET TYPE N
4"x 53" DIAM.
STL. PLATE
1/4 "x 6"
STL. BAN D
NICOLON MIRAFI 140N
FILTER FABRIC
CONST 3" THICK A.C.
SLOPE PROTECTION
ELEV.
A: 5 1. 0
Di:
48"
D2:
30"
Li:
10.83'
L2:
2.5'
1/4 x 6
1/4 11 x 2" STL. BAR
6 O.C.
Z
LIJ
N a.
PIPE RIM
N
49.0
FL ^'
6" x 12" 12"
OPENING (TYP
2' 2' 48"' DIAM. 2' 2'
C.S.P.
MODIFIED "TYPE V" INLET DETAIL 8A
PIPE
k laid lengthwise
and mortared
nside edge of R.C.P. groove
copping at en o Alpe SECTION or end of pipe (if broken)
II Dll
1 Cement grout capping
• _ i
` Brick 8i mortar closure
DOUBLE COURSE 4" x 8"
ELEVATION
PIPE CLOSURE -TYPE "B"
(Brick and Mortar)
NOTE:
I. Type "B"closure for I'D" not larger than SAN SERNARDINO COUNTY
FLOOD CONTROL DISTRICT
36° unless approved or specified by the
• REVISIONS owN. BY DATE
Engineer.
2.See specifications for additional information. C. L. 5-9-63
L
SCALE: 1 "= 2'
GRADE SURFACE
TO DRAIN
51.0
FS
-CONST 3" THICK A.C.
SLOPE PROTECTION
NOTES:
FABRICATE WELDED ASSEMBLY WITH
MODIFICATIONS AS SHOWN
HEREON.
CONSTRUCT STRUCTURE PER
O.C.E.M.A. (O.C.P.F. & R.D.)
STD. PLAN 1305.
WRAP W/NICOLON MIRAFI 140N
FABRIC AND SECURE WITH
CHICKEN WIRE.
JI L. DHIVV �
,r
RECO LDRAWINU
THESE RECORD DRAWINGS HA\/E BEEN PREPARED, IN
PART, ON THE BASIS OF INF`:HMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO THE DOCUMENTS AS
A RESULT THEREOF.
STD. PLAN
130.5
SHT. I OF 2
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PIAN
300-2
CONCRETE COLLAR FOR RCP
'ISM
'-100 MM
O 300 mm(+4012')
EACH WAY
5 mm(I/4•)R
�_ W
ASSEMBLY
STREET, GUTTER.
OR LOCAL- OEPRES-
SION SURFACE
3:
m. OPE
�� -... I I
GREENBO1964 AfTTEE
1500 mm (609 TO 1800 mm (72')
00-2
300-2
FLOW LINE
cr•:
3 IRm
REV' 1M
FACE
PLATE
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
((TYP)
E
SPECIFICATIONS
I
I
UNDISTURBED EARTH
BEDDING. PER
SCORING
LINE
SPECIFICATIONS
CURB LINE
c N a
N t o
!
12
I
FOR OUTLET SEE STD.
f F
EXTRA 15M(•41 +
STEPS
r -CATCH BASIN FLOOR
a
O�
ION 2 SIDES OF
MANHOLE FRAME
t
_
W.
AND COVER
(44) MIN.
I
I300
Min
75 mm mm300
CATCH BASIN E
(12')MA)L
3')R
I MANHOLE FRAME E
I
I
W^
y
AND COVER-
W
w
M y
O.
st
__ -
Z
OZ
E_
-io
OPTIONAL SUBGRADE CONNECTOR PIPE
OR MONOLITHIC
d
U
-�
a3
zoo
CATCH BASIN
B
CONNECTION
��� STEPS a II
o.c
ov
SECTION
A -A
A
--1
I
N V f
Q
I
\
100 mm
200 mm(8')
IOM(°41
`R
1
u �r
-90°
m
Ix
C
Q
10
DOWEL (TYP.) -•-
PLAN
P
DOWEL DETAIL
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PIAN
300-2
CONCRETE COLLAR FOR RCP
STANDARD PIAN
PROMULGATED TTHECURB
PUBLIC WORKS STANDARDS INC.
OPENING CATCH BASIN
METRIC
GREENBO1964 AfTTEE
1500 mm (609 TO 1800 mm (72')
00-2
300-2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
REV' 1M
SHEET 1 OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
NOTES
I. WHERE THE BASIN IS TO BE CONSTRUCTED WITHIN THE LIMITS OF EXISTING OR PROPOSED
SIDEWALK OR IS CONTIGUOUS TO SUCH SIDEWALK. THE TOP SLAB OF THE BASIN MAY BE
POURED EITHER MONOLITHIC WITH THE SIDEWALK OR SEPARATELY, USING THE SAME CLASS
OF CONCRETE AS IN THE BASIN. WHEN POURED MONOLITHICALLY. THE SIDEWALK SHALL BE
PROVIDED WITH A WEAKENED PLANE OR A 25 mm(I-) DEEP SAWCUT CONTINUOUSLY AROUND
THE EXTERNAL PERIMETER OF THE CATCH BASIN WALLS. INCLUDING ACROSS THE FULL WIDTH
OF THE SIDEWALK. SURFACE OF ALL EXPOSED CONCRETE SHALL CONFORM IN SLOPE. GRADE.
COLOR, FINISH. AND SCORING TO EXISTING OR PROPOSED CURB AND WALK ADJACENT TO THE
BASIN.
2. ALL CURVED CONCRETE SURFACES SHALL BE FORMED BY CURVED FORMS. AND SHALL NOT BE
SHAPED BY PLASTERING,
3. FLOOR OF BASIN SHALL BE GIVEN A STEEL TROWEL FINISH AND SHALL HAVE A LONGITUDINAL
AND LATERAL SLOPE OF 1:12 MINIMUM AND 1:3 MAXIMUM, EXCEPT WHERE THE GUTTER GRADE
EXCEEDS 8 PERCENT, IN WHICH CASE THE LONGITUDINAL SLOPE OF THE FLOOR SHALL BE
THE SAME AS THE GUTTER GRADE. SLOPE FLOOR FROM ALL DIRECTIONS TO THE OUTLET.
4. DIMENSIONS:
B = 970 mm(3' -2')
V = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF
THE CATCH BASIN AT THE OUTLET = 1.35 m(4.51).
VU = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT AT
THE UPSTREAM END OF THE BASIN. AND SHALL BE DETERMINED BY THE REQUIREMENTS
OF NOTE 3. BUT SHALL NOT BE LESS THAN CURB FACE PLUS 300 mm(120).
V, = THE DIFFERENCE 1N ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF
THE INLET, NOTED ON THE PROJECT PLANS.
H = NOTED ON THE PROJECT PLANS.
W = NOTED ON THE PROJECT PLANS.
A = THE ANGLE, IN DEGREES, INTERCEPTED BY THE CENTERLINE OF THE CONNECTOR PIPE
AND THE CATCH BASIN WALL TO WHICH THE CONNECTOR PIPE IS ATTACHED.
5. PLACE CONNECTOR PIPES AS INDICATED ON THE PROJECT PLANS. UNLESS OTHERWISE SPECI-
FIED. THE CONNECTOR PIPE SHALL BE LOCATED AT THE DOWNSTREAM END OF THE BASIN.
WHERE THE CONNECTOR PIPE IS SHOWN AT A CORNER. THE CENTERLINE OF THE PIPE SHALL
INTERSECT THE INSIDE CORNER OF THE BASIN. THE PIPE MAY BE CUT AND TRIMMED AT A
SKEW NECESSARY TO INSURE MINIMUM 80 mm(W) PIPE EMBEDMENT. ALL AROUND. WITHIN
THE CATCH BASIN WALL. AND 75 mm(36) RADIUS OF ROUNDING OF STRUCTURE CONCRETE.
ALL AROUND. ADJACENT TO PIPE ENDS. A MONOLITHIC CATCH BASIN CONNECTION SHALL BE
USED TO JOIN THE CONNECTOR PIPE TO THE CATCH BASIN WHENEVER ANGLE 'A' IS LESS THAN
70 DEGREES OR GREATER THAN 110 DEGREES, OR WHENEVER THE CONNECTOR PIPE IS LOCATED
IN A CORNER. THE OPTIONAL USE OF A MONOLITHIC CATCH BASIN CONNECTION IN ANY CASE
IS PERMITTED. MONOLITHIC CATCH BASIN CONNECTIONS MAY BE CONSTRUCTED TO AVOID CUT-
TING STANDARD LENGTHS OF PIPE.
6. STEPS SHALL BE LOCATED AS SHOWN. IF THE CONNECTOR PIPE INTERFERES WITH THE STEPS.
THEY SHALL BE LOCATED AT THE CENTERLINE OF THE DOWNSTREAM END WALL. STEPS SHALL
BE SPACED 300 mm(129 APART. THE TOP STEP SHALL BE 175 mm(72) BELOW THE TOP TO THE
MANHOLE AND PROJECT 65 mm(2-1/21. ALL OTHER STEPS SHALL PROJECT 130 mm(5').
7. DOWELS ARE REQUIRED AT EACH CORNER AND AT 2 m(79 ON CENTER (MAXIMUM) ALONG THE
BACKWALL.
8. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN:
308 MONOLITHIC CATCH BASIN CONNECTION
309 CATCH BASIN REINFORCEMENT
310 CATCH BASIN FACE PLATE ASSEMBLY AND PROTECTION BAR
312 CATCH BASIN MANHOLE FRAME AND COVER
635 STEEL STEP
636 POLYPROPYLENE PLASTIC STEP
9. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL
VALUES. IF METRIC VALUES ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE
METRIC VALUES, EXCEPT REINFORCING BARS SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED
FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION
SHALL BE ENGLISH UNITS.
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PIAN
300-2
CONCRETE COLLAR FOR RCP
CURB OPENING CATCH BASIN
SHEET 2 OF 2
..
r
380 c 2
L
JTW C 1, 6637
Cry11. �P
q4FOFCAI��
W t sem' lf1t.�
6elz i.
15M O 300 mm (04 O 12'
L/2. (TYP.)-1.--.L
.s•'' rte. ~
N I /
:W OR •
:IST.
FLOW o �` NFB,
9 I !
Top
FLOW
15M 0 300 mm
(94 O 12') --
3-15M (a4) CIRCULAR TIES,
SEE NOTE 9
150 mm
6') MIN
CUT
NO. 2 CUT NO. 1
LINE q
N
90, CUT
NO. 2
LINE
150 tnm CUT N(
6') MIN
3.14 (Do -
DETAIL 'A' (SEE NOTE 10)
SONO -TUBE. OR EQUAL. INTERIOR FORM
CUT NO. 1: SAW THE TUBE AT AN ANGLE OF A/2 WITH THE TRANS-
VERSE PLANE. REVERSE ONE SECTION AND TAPE BOTH SECTIONS
TOGETHER FORMING THE DEFLECTION ANGLE A.
CUT NO. 2: SAW THE TUBE LONGITUDINALLY REMOVING A STRIP
3.14 (DO -D ) WIDE ON THE SIDE OPPOSITE THE OPEN JOINT.
BEND THE ENDS OF THE CUT TOGETHER AND INSERT THE
TUBE IN THE PIPE
330-C-23 (560-C-3250) CONCRETE
25 mm (10) (TYP.)
D L T
300 mm (120) 300 mm (120) 100 mm (46)
450 MM 081' 300 mm (12')' 125 mm (54
600 mm (240) 300 mm (IF) 150 mm (67
750 mm (300) 450 mm (18') 175 trim (71)
900 mm (368) 450 mm (180) 225 mm (90)
1050 mm (42') 450 mm (IB') 225 mm (9')
1200 mm (48.) 450 mm (18') 250 mm (109)
1425 mm (57.1 450 mm (180) 250 mm (100)
1500 mm (60' 525 rnm (211 275 mm (Q-)
1650 mm (66. 525 mm (21.1 275 nm (II')
1800 mm (720) 600 mm (24. 300 mm (12')
�- INTERIOR SURFACE
OF PIPE
DETAIL 'B"
TYPICAL JOINT FOR
REINFORCED CONCRETE PIPE
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
PRWORKS11T�gy THEDARDS
CONCRETE COLLAR FOR RCP
STANDARD PLAN
PUBLIC ° INC.
300 mm 12" THROUGH 1800 mm 7211
380 c 2
REV' 1998
1500 mm (609 TO 1800 mm (72')
SHEET 1 OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
NOTES
I. A CONCRETE COLLAR IS REQUIRED WHERE THE CHANGE IN GRADE -
EXCEEDS 10 PERCENT.
2. FOR CURVE JOINTS (SEE DETAIL B. SHEET 0
IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE
THAT IS GREATER THAN 25 mm (I'). BUT IS LESS THAN 75 mm(W)
A CONCRETE COVER IS REQUIRED IN ACCORDANCE WITH SUBSECTION
306-1.2.4 OF THE SSPWC.
IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE
THAT IS EQUAL TO OR GREATER THAN 75 mm (3'). BUT LESS THAN
150 mm (62). A CONCRETE COLLAR IS REQUIRED. IF THE CLEAR
SPACE IS 150 mm (60) OR GREATER. A TRANSITION STRUCTURE
IS REQUIRED.
3. CONCRETE COLLAR SHALL NOT BE USED FOR A SIZE CHANGE ON
THE MAIN LINE.
4. CONNECTOR PIPES
A. WHERE PIPES OF DIFFERENT DIAMETERS ARE JOINED WITH A
CONCRETE COLLAR. L AND T SHALL BE THOSE OF THE LARGER
PIPE. D=DI OR 02. WHICHEVER IS GREATER.
B. WHEN DI IS EQUAL TO OR LESS THAN Q2. JOIN INVERTS AND
WHEN DI IS GREATER THAN D2. JOIN SOFFITS.
5. FOR PIPE LARGER THAN 1800 mm (720) SPECIAL COLLAR DETAILS
ARE REQUIRED.
6. FOR PIPE SIZE NOT LISTED USE NEXT SIZE LARGER.
7. REINFORCEMENT SHALL CONFORM TO ASTM A 615 M (A 615) GRADE
300(40).
8. WHERE REINFORCING IS REQUIRED THE DIAMETER OF THE CIRCULAR
TIES SHALL BE D+(2X WALL THICKNESS) + T.
9. REINFORCING SHALL BE USED WHERE THE PIPE DIAMETER IS
GREATER THAN 525 mm (21') AND ON ALL PIPES WHERE THE SPACES
BETWEEN THE EXTREME OUTER ENDS IS 75 mm (30) OR LARGER.
CIRCULAR TIES=
PIPE DIAMETER
N0. OF
CIRCULAR TIES
525 mm (210) OR LESS
3
600 mm (24') TO 750 mm (30')
3
825 mm (33') TO 1425 mm (57-)
4
1500 mm (609 TO 1800 mm (72')
5
WHERE THE SPACE BETWEEN PIPE ENDS EXCEEDS. 75 mm (39. THE
NUMBER OF CIRCULAR TIES SHALL BE INCRW. TO MAINTAIN AN
APPROXIMATE SPACING OF 150 mm (69) O.C:' �' =-
10. WHERE THE PIPE IS 525 mm (21') OR LESS �`p1AMETER AN INTERIOR
FORM OF UNSEALED SONO -TUBE OR EQUAL/SHALL BE USED TO
PROVIDE A SMOOTH INTERIOR JOINT. THEI`RAPER FORM MAY BE
LEFT IN PLACE (SEE DETAIL A). WHEN :THEA` P IPE I S .600 mm (240)
OR LARGER A REMOVABLE INTERIOR FOUSHALL"BE USED OR.THE
INTERIOR JOINT SHALL BE COMPLETELYFILLED WITH MORTAR AND
NEATLY POINTED. t ' -
II. DIMENSIONS SHOWN ON THIS PLAN FORETRIC Na.ENGLISIJUNITS
ARE NOT EXACT EQUAL VALUES. IF ME' E=�1RE. USED. ALL
VALUES USED FOR CONSTRUCTION SHALL' •ICNALUES. EXCEPT
REINFORCING BAR SIZES IN ENGLISH UNITS MA -SUBSTITUTED FOR
METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES,'. -USED
FOR CONSTRUCTION SHALL BE ENGLISH UNITS. j
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PLAN
c 2
SHEET20172
300
CONCRETE COLLAR FOR RCP380
mm 12" THROUGH 1800 mm 72"
E LATERAL/CONNECTOR PIPE
I (i. MAIN LINE RCP
49$ I
CONC. PIPE, RCP OR CSP
O' CLASS C 15 mm (I/2' MIN.
tia MORTAR I ca SEE NOTE 4
� -� i -•�.�_
I +B BEDDING OF
R INLET PIPE �4ga
V BACKFILL WITH °� '" 4'' SEE NOTE 6
AYA45° 265 Kq-C-14 Mpo
1 -100 v 4.
CASE I
PLAN
..a; ....
-CRETE
PRUC OMULGATED BY THEDARDS
COC OR
sTANAETR�c LAN
PU6GREENRKSSTAMMITTEINC..
OREENHOI COMMITTEE
rip <_ 600 mm (24IT
L
COMPACT SOIL TO
REV. 1998
SHEET 1 OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
RELATIVE DENSITY
REQUIRED BY
SPECIFICATIONS
UNDISTURBED EARTH
BEDDING. PER
SPECIFICATIONS
CASE
I
SECTION
B -B
FOR OUTLET SEE STD.
CATCH BASIN PLANS
r -CATCH BASIN FLOOR
O�
265 Kg -C-14 Mpo
(450-C-2000)
CONC. ENCASEMENT,
SEE NOTE 5 ,
/Sp _
SEE NOTE.3
5 mm (1/2' MIN /
SEE NOT
-- - 1 LB>450
- --
CASE 2
(SEE NOTES -9 a 10)
1/2 OD MIN.
CONC. PIPE. BACKFILL
RCP OR CSP r�
BEDDING
OD
CASE 1
SECTION C -C
"Ao.re TO SL
DNS
PLAN
CASE 3
SADDLE CONNECTION
SECTION
IRTAR
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
PRUC OMULGATED BY THEDARDS
JUNCTION STRUCTURE - PIPE TO PIPE
sTANAETR�c LAN
PU6GREENRKSSTAMMITTEINC..
OREENHOI COMMITTEE
rip <_ 600 mm (24IT
L
332 -1
REV. 1998
SHEET 1 OF 2
USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
GENERAL NOTE
I. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS
ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED, ALL
VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. IF
ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION
SHALL BE ENGLISH UNITS.
NOTES
CASE I AND CASE 2
I. IF ANGLE A IS LESS THAN 450 OR IF D IS LARGER THAN 600 mm
(240), THEN ANOTHER STANDARD STRUCTURE SHALL BE SPECIFIED.
2. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED
ONE-HALF THE INSIDE DIAMETER OF THE MAIN LINE.
3. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY. IF THE
INLET PIPE CANNOT ENTER RADIALLY, THEN ANOTHER STANDARD
STRUCTURE SHALL BE SPECIFIED.
4. THE SIZE OF THE OPENING INTO THE MAIN LINE SHALL BE THE
OUTSIDE DIAMETER OF THE INLET PIPE PLUS 30 mm (I') MINIMUM
TO 75 mm (31 MAXIMUM.
5. ALL CONNECTOR PIPES FOR CASE 2 SHALL BE ENCASED IN CONCRETE
IF LAID WITHIN THE MAIN LINE EXCAVATED TRENCH OR IF LAID ON
FILL WHICH HAS NOT BEEN DENSIFIED.
6. BURN OR CHIP END OF CONNECTOR PIPE FLUSH WITH INNER SURFACE
OF MAIN LINE. ROUND EDGE OF CONCRETE PIPE OR RCP.
7. ALL CSP AND FITTINGS SHALL BE GALVANIZED.
S. STATION SPECIFIED ON THE PROJECT DRAWINGS APPLIES AT THE
INTERSECTION OF THE INSIDE WALL OF MAIN LINE AND THE CENTER
LINE OF INLET PIPE.
9. CASE 2 SHALL NOT BE USED TO CONNECT TO THE FLOOR OF A
GRATING CATCH BASIN WHERE THE GRATE WILL BE SUBJECT TO
VEHICLE TRAFFIC.
10. FOR CASE 2, NOT MORE THAN 3.5 m (121 OF INLET PIPE SHALL BE
LOCATED WITHIN THE MAIN LINE EXCAVATED TRENCH.
CASE 3
11. CONNECTIONS TO PIPES 525 mm (211 OR LESS IN DIAMETER WITHOUT JUNCTION
STRUCTURES OR PRECAST,Y BRANCHES SHALL BE MADE WITH SADDLES.
12. THE OUTSIDE DIAMETER OF THE INLET PIPE SHALL NOT EXCEED ONE-HALF
THE INSIDE DIAMETER OF THE MAIN LINE.
13. TRIM OR CUT SADDLE TO FIT SNUGLY OVER THE OUTSIDE OF THE MAIN LINE
SO ITS AXIS WILL BE ON THE LINE AND GRADE OF THE CONNECTOR PIPE.
14. THE OPENING INTO THE PIPE SHALL BE CUT AND TRIMMED TO FIT THE
SADDLE SO THAT NO PART WILL PROJECT WITHIN THE BORE OF THE
SADDLE PIPE.
15. THE CONNECTOR PIPE SHALL BE SUPPORTED AS SHOWN IN CASES I AND 2.
AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER
STANDARD PIAN
METRIC 3322- 1
SHEET 2OF2
JUNCTION STRUCTURE - PIPE TO PIPE
ID < 600 mm 24")
J:\126-2023�stotTn�sd09.dwa. 5/17/2005 12:06:28 PM. DJ