HomeMy WebLinkAbout4914-1V)
01
V)
U_
Ld
CITY OF FONTANA STREET. IMPROVEMENT GENERAL NOTES'.
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTIONS C'GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTORS
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEERS FOR RESOLUTION.
J. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY
DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK
INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR To THE
START OF ANY WORK IN PUBLIC RIGHT -OF -.WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -
METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONS181LITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS
OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTORS SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL
SAFETY
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
MOVEMENT
9. NO MATERIAL OR EQUIPMENT SHA LL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING
A SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBIL17Y OF THE CONTRACTOR TO DETERMINE, IN THE FIELD,
THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER
PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT 1-800-277-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING,
BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
1J. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE -OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADE. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, A40NUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OR EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED As A RESULT OF THIS
CONSTRUCTION, SHALL BE REPLACED. THE CONTRACTOR SHALL. NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESS AT ALL TIMES. A
MINIMUM 12 FOOT LAND SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES
PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT, OR DEBRIS To BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH HACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
2J. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION, FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
24. CARE SqO ULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE.- APPROVED AT THE
TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE
SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTI�ITIES SHALL HE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
JO. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO
PLACEMENT
J1. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND
APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFFER COMPLETION OF
ROUGH GRADING.
J2. ACTUAL THICKNESS OF A.C. PAVEMENT ANDIOR BASE COURSE MATERIAL FOR STRUCTURAL STREET
SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF
FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
JJ. ALL MANHOLES, CLEAN OUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
,34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CRY TRAFFIC
ENGINEER.
J5. CONTRACTOR SHALL RELOCATE ANDIOR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS
AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS TO THE C17 -Y ENGINEER. I
CITY OF FONTANA
STREET IMPROvEMENT PLAN
14594 ALISO DRIVE
U71LITY CONTACTS
ELECTRICITY
SOUTHERN CALIFORNIA EIDSON COMPANY
JOO N. PEPPER AVE,
RIALTO CA. 92J76
UNDERGROUND. (909) J57-62JJ
TRANSMISSION. (909) 875-5100
PIPELINES * - (909) 657-12JJ
DISTRIBUTION: (909) J57-6233
GAS
SOUTHERN CALIFORNIA GAS CO.
1981 LUGONIA AVENUE
REDLANDS, CA. 92J74
ATT'N JOHN OATES
EMERGENCIES: (800) 427-2200
ENGINEER'S NOTE:
6
APN: 0236m-,,121-06
30 $
241
5j
10 1
0. 50'_ ___lj._j)_ 10.71
Q: VARIES
27. Qj 1.967. TO 2. 93Z 21w,
.... . ...... .. .. . ..... ... ..... ..
GRIND 0. 10' AND
0 VERLA Y 0. 10'
Zzo
EXISTING IMPROVEMENT
WA TER
FONTANA WATER COMPANY
8440 NUEVO AVENUE
FONTANA, CA. 92JJ5
ATTN- MICHAEL McGRAW
(909) 822-2201
FAX (909) 283-5046
m
EXIST. STREET CROSS-SECTION
ALISO. DRIVE
T.I. -7-9
NOT TO SCALE
GENERAL TELEPHONE COMPANY
1400 E. PHILLIPS RANCH BLVD.
ONTARIO, CA. 91766
ATT'N.- STEVE HOCK
(800), 422-4 1 JJ
SEWER
CITY OF FONTANA
8353 SIERRA AVENUE
FONTANA, CA. 92J35
(909) J50-6632
COMCAST CABLEVISION
1205 DUPONT AVENUE
ONTARIO, CA. 91761
A TTN.- JA CK HA YES
(909) J90-47JB
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR ANY
OTHER STRUCTURES SHOWN ON THESE DRAWINGS WERE OBTAINED BY A SEARCH OF THE
AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO OTHER UTILITIES
OR STRUCTURES EXCEPT AS SHOWN ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED
TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THE
DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR
JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORM4-.i'. WORKING HOURS, ANO THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CITY, THE OWNER AND THE
ENGINEER HARMLESS FROM ANY AND -ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION
WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING
FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER
UNDERGROUND SERVICE ALERT
CALLJOLL FREE
1-800
227-2600
TWO WORKING DAYS BEFORE YOU DIG
R EV, I REVISION DESCRIPTION IDATE I ENGR.1 CITY IDATE
LEGEND:
Z)
2
FL =
FLOWLINE ELEVATION
TC =
TOP OF CURB ELEVATION
(X)
EXISTING ELEVATION
TP
TOP OF PAVEMENT
W
WA TERLINE
FS
FINISHED SURFACE
NG
NATURAL GROUND
EP
EDGE OF PA VING
CF
CURB FACE
EP
EDGE OF PAVING
PCO PA VING
PCC SURFACE
EXISTING PAVEMENT REMOVAL
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPRCVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
I
NEW PAVEMENT
SECTION
CONSTRUCTION NOTES:
T
GRIND 0.10' MIN.
AND 0 VERLA Y 0. 10' MIN.
LAP JOIN DETAIL
NOT TO SCALE
FREE Y 10
10
BOYLE AVE.
SLOVER A VE.
lzn�
ALISO DR.
R
SANTA ANA A VE.
VICIIVITY MAID
NOT TO SCALE
CONSTRUCT COMMERCIAL DRIVEWAY PER CITY STD. NO. 1002, W=AS SHOWN ON PLAN
CONSTRUCT 8" P.C.C. CURB AND GUTTER PER CITY STD. NO. 1000
CONSTRUCT 5' WIDE P.C.C. SIDEWALK PER CITY STD. NO. 1006
CONSTRUCT 5.5 pl. A.C. (MIN.) OVER PAVING OVER'12" (MIN.) OF 95.2o (_70MPACTED NATIVE SUBGRADE
5 SAW -CUT, REMOVE IIND DISPOSE EXISTING A.C. PAVING
8 6 CONSTRUCT SIZE 3, UNDER SIDEWALK DRAIN PER CITY STD. 3001
7 CONSTRUCT FIRE HYDRANT (SEPARATE PERMIT)
8 RELOCATE EXISTING WATER METER
9 REMOVE EXISTING POWER POLE (BY OTHERS)
INSTALL STREET LIGHT (PER STREET LIGHT PLAN)
PAINT 4" WIDE WHITE EDGE LINE STRIPING
REMOVE AND DISPOSE EXISTING CHAIN LINK FENCE
@ INSTALL CA. TYPE L-A (OMG-2V) OBJECT MARKER PER CA. MUTOD 2010, FIG. JC -1 (CA.)
P 0*1
(9 INSTALL REFLECTIVE BAND ON SCE POWER POLE %' 11 - it t! t
BENCH MARK:
DESCIRIPTION: CITY, OF FONTA.NIA BENCH MARK RIO. 518
ELEVATION = i002.80
Prepared Under The Supervision Of:
E Sl HENRY C. POOUIZ '
c HP ENGINEERING, INC.
a. T\ / 0
ESTIMATED
OUANTMES
1, 386 S. F.
J41 L. F
1, 705 S.F.
J60 TON 10, 842 S. F.
5,6 10 S. F.
J EA CH
I EA CH
1 EACH
2 EACH
2 EACH
12J L. F.
341 L. F.
6 EA CH
1 E4CH
BASIS OF BEARINGS IS THE CENTERLINE OF ALISO DRIVE
BEING 1V89*44`10"E PER R.S. 07-080, RECORDED IN
BOOK PAGE 84, RECORDS OF SAN BERNARDINO COUNTY
I Itu �1/ I-\ L_ ID I U_VV ut-xu DRAWN BY:
No. 37037 REDLP4)S, CA. 92374 CADD
(909) 7 9- 797, FAX (909) 799-1508
DESIGNEff- _BY
Exp. 6-30-12 75. 1 HCP
CIVI I CHECKED BY:
CAL A, DATE: 69/11// HCPo?f4
HENRY C. POQUIZffiC.E. 370,37
CITY OF FONTANA, CALI FORNIA
STREET IMPROVEMENT PLAN
SCALE:
AS SHOWN
14-',5;94ALlS0 DRIVE -
DATE:
6/21/11
/,,,-/,ASP #06'021j
APPROV)p BY: i DRAWING NO.
DlTElq
1 4914
ENGINEER R.C.E. 51152