HomeMy WebLinkAbout3873-1GENERAL SEWER NOTES
r,alTY 01= F=ONITANIA raAl 1p"Pl�k IA
1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, '
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CANNOT BE
SEWER IMP OVEMENT PLANS
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA- COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TW0 WORKING DAYS PRIOR TO THE STAR1" OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT `TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATION GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED
BY SHORING, SLOPING OF THE GROUND OR 'OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFE%TY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY NTHOUT OBTAINING A SEPARATE
PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT
SMALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION
AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE
CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITIES COMPANIES SHALL BE GIVEN
TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTH(JRIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO
CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION
OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT
PRIOR NOTIFICATION TO THE CITY ENGINEER.
15 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND
BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE
CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SQ THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES.. A MINIMUM
12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENQY. .
VEHICLES.
C0 E AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL INCLUDING ADEQUATE:
18 THE ONTRACTOR SHALL PR VID
WATERING, AT AI .I. TIMES. ; = s `' '' :t.,,
t, n
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE -"DEPOSITED`ONTO PUBLIC OR
PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. '~
21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAItU- RE --TO OBTAIN THE REQUIRED DENSITY
SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON
INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRED TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING
IMPROVEMENTS. ;
23 ALL EXPOSED CONCRETE •SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCTION IS TO BE DONE 1N PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE
BOUNDARY, NO MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR
TERMINAL - CLEANOUT.
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL. AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.)
EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION: C700 FOR V.C.P.
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE .END OF THE DAY WITHOUT PRIOR APPROVAL- .OF' �Tf �TY`ENGINEER.
27 SHORT VCP STUBS NTH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE -:WA TO' ALLO; FOR MINOR
DEFLECTIONS IN ALIGNMENT.
I
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES AND- -VERIFY ELEVATI:QN AND, LOCATION OF
CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY=GORREC{TN,SS OF `ELEVATIONS OR
LOCATIONS SHOWIJ ON THE PLANS. _
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN
PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT
AS MEASURED FROM THE UTILITY EASEMENT.
31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL.
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY
THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
BENCHMARK
SAN BERNARDINO COUNTY
B.M. OF 627, NAVD 88
ELEVATION: 1011.70 FEET
TOLL FREE -800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
FOR RNO. 14244
INDEX MAP
SCALE 1 "=200'
SHEET INDEX MAP
SHEET N0.
REVISION DESCRIPTION
DESCRIPTION
1
TI TLE
SH EET
2
DETAILS
3
PLAN
& PROFILE (BONSAI AVENUE, SPARTAN LANE, BRIARCLIFF AVENUE)
4
PLAN
& PROFILE (BRIARCLIFF AVENUE)
5
PLAN
& PROFILE (WILLOW DRIVE)
UTILITY AGENCIES
CITY OF FONTANA
8353 SIERRA AVE
FONTANA CA 92335
TELEPHONE (909) 350-6632
THE GAS COMPANY -- DISTRIBUTION FACILITIES
16231 VALLEY BLVD.
FONTANA, CA 92335
TELEPHONE ._(889-9711) OR (800) 422-4133
THE GAS COMPANY -- TRASMISSION DEPARTMENT
BREA, CA 92621
TELEPHONE (909) 529-2889 OR (800) 422-4133
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909)• 357-6231, (SO. OF MERRILL)
(909) 357-6223 (NO. OF MERRILL)
(800) 422-4133
BASIS OF BEARINGS
THE BEARING OF N 89'34'47" W FOR THE SOUTH- LINE
OF THE SOUTHWEST ONE-QUARTER OF SECTION 36
TOWNSHIP 1 SOUTH, RANGE 6 WEST, AS SHOWN ON
THE TRACT 13613 IN BOOK 204 PAGES 19-22 OF THE
OFFICIAL RECORDS OF SAN BERNARDINO COUNTY.
LEGEND
GENERAL SEWER NOTES (CONTINUES)
m w a U
11 —1 JURUPA AVE L
"'� KnECT SITE
VICINITY MAP
N.T.S.
THOMAS BROTHERS MAP REFERENCE
SAN BERNARI)INO AND RIVERSIDE
COUNTY 2003 EDITION
PAGE 644, F`.4
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISH GRADE BY THE PAVING
CONTRACTOR UPON COMPLETION OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC
CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD
DRAWINGS TO THE CITY ENGINEER.
SHEET
REVISION DESCRIPTION
O
SEWER
MANHOLE
Q
SEWER
MAIN
SEWER
LATERAL
U
DATE-
, Q)
05-27-2005
O
DRAWING V,..
1-
j
LEGEND
GENERAL SEWER NOTES (CONTINUES)
m w a U
11 —1 JURUPA AVE L
"'� KnECT SITE
VICINITY MAP
N.T.S.
THOMAS BROTHERS MAP REFERENCE
SAN BERNARI)INO AND RIVERSIDE
COUNTY 2003 EDITION
PAGE 644, F`.4
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISH GRADE BY THE PAVING
CONTRACTOR UPON COMPLETION OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC
CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD
DRAWINGS TO THE CITY ENGINEER.
SHEET
NO
O
SEWER
MANHOLE
Q
SEWER
MAIN
SEWER
LATERAL
U
SAN BERNARDINO COUNTY FLOOD CONTOL DISTRICT
825 E. THIRD STREET
SAN BERNARDINO, CA 92408
(909) 383-1665
PACIFIC TELEPHONE AND TELEGRAPH COMPANY
3073 ADAMS STREET
RIVERSIDE, CA 92504
(714) 359-2585 OR (800)422-4133
FONTANA WATER COMPANY
8440 NUEVO AVENUE
P.O. BOX 987
FONTANA, CA 92334
(909) 822-2201
CONSTRUCTION NOTES AND QUANTITIES
NO. ITEM
1 INSTALL STANDARD SEWER MANHOLE PER
CITY OF FONTANA STANDARD DETAIL 112.
2 INSTALL 8" DIA. EXTRA STRENGTH VITRIFIED CLAY PIPE PER CITY OF
FONTANA STANDARDS AND SPECIFICATIONS
SEE BEDDING DETAILS
3 CONSTRUCT 4" SEWER LATERAL -AND HOUSE CLEANOUT
PER CITY OF FONTANA STD. NO. 125 AND INSTALL SEWER CLEAN-OUT
BOX PER CITY OF FONTANA STD. 125A (IN CONCRETE AREAS) OR
1258 (IN LANDSCAPE AREAS).
7 :=> "=INSTALL BACKFLOW PREVENTER
RECORD DRAWING
A
THESE REC.ORD-DRAWI , S PREPARED, IN
PART ON THE BASIS: O F;
:. . _ ' OMPILED AND
FURNISHED 8Y DTFiEF 3- �A ENONE WILL NOT BE
RESPONSIBLE FOR.AN?'%ARORS OR'OKISSIONS WHICH
HAVE BEEN INCQRPOHIIEtTED IJO 'FIE:UMENi8 A8
A RESULT THEREOF.' H' r
4. •. r
�'" SAFETY RESPONSIBILITY
h..
GENERAL TELEPHONE COMPANYRE 410N No.®
245 N. MOUNTAIN AVENUE
POMONA, CA 91766 it
i
(213) 357-2257 OR (800)422-4133 W 'T 14041 L. lW T`U RU
MaDOLS testi ASSO CAATt-5, ISG,
9302 PITT5WJR0H AVIS., STE. 230
RANG N O 0LfCs + M0t4 s , . CA 1173b
PRONF-' C909)48(- 403-.2
APPLICANT/DEVELOPER
FIESTA DEVELOPMENT
470 E. HARRISON STREET
CORONA, CA 92879
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
QROFESSI,-
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, W a m
No. 024725 '
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO * Exp.12/31/05
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND 9�- CIVIL
-��
STANDARDS IN EFFECT. OF OPl
iumnaxosm ".0
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB
SITE CONDITIONS DURING THE ('BURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY, THAT THE REQUIREMENTS SHALL APPLY CONTINUOUSLY AND
.NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND,
INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNEC PION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCE-NTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
EXISTING UNDERGROUND STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN
THESE PLANS ARE OBTAINED. BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS
RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
THE CONTRACTOR SHALL CALL DIGALERT AND HAVE ALL UTILITIES MARKED BEFORE DIGGING.
VAN DELL AND ASSOCIATES, INC.
CIVIL ENGINEERS
SURVEYORS LAND PLANNERS DRAWN BY:
17801 CARTWRIGHT ROAD TWH
IRVINE CA 92614 (949) 474-1400 DESIGNED BY:
UNM TM %%RMVISION OF: D�4
CHECKED BY:
�� �••
DONALD R. GORDON R.C.E. 24725 ` DATE DRG
u _ ice.-T•.�...:'
TOTAL UNIT
8 ._.,_1. EA
2,230 LF.
34 ( EA
CITY OF FONTANA r -Ai lPnPKIIO
SEWER IMPROVEMENT PLAN
TRAC 0.14244
LE SHEET
AVED BY:
R ARDO SANDOVAL-CITY ENGR. R.C.E. 51152 DATE
0
n
Q
LO
dN-
alw,
O
cn
U)cn
3873 1 /
51
00
/n
SCALE: 1"=40'
U
DATE-
, Q)
05-27-2005
O
DRAWING V,..
1-
j
3873 1 /
51