Loading...
HomeMy WebLinkAboutCoyote canyon Specific PlanEXISTING CAPACITY STUDY FOR THE HAWKER CRAWFORD CHANNEL COYOTE CANYON SPECIFIC PLAN FONTANA. CALIFORNIA PREPARED FOR: A COYOTE CANYON, LLC 16027 BROOKHURST STREET • SUITE G-251 FOUNTAIN VALLEY, CA 92708 PREPARED BY: AEI•CASC ENGINEERING 937 SOUTH VIA LATA • SUITE 500 COLTON, CA 92324 (909) 783 -3636 • Fax (909) 783 -0108 MAY 28, 2002 REVISED JANUARY 9, 2003 No. 416 ,G OF E�q EXISTING CAPACITY STUDY HAWKER CRAWFORD CHANNEL AWk COYOTE CANYON SPECIFIC PLAN — FONTANA, CALIFORNIA TABLE OF CONTENTS PAGE I . PURPOSE OF STUDY ......................................................................................... ..............................1 II. PROJECT SITE AND DRAINAGE AREA OVERVIEW ............................ ............................... 1 -2 III. FLOOD PLAIN ANALYSIS .......................................................................... ............................... 2 -3 IV. FINDINGS ............................................................................................................. ..............................3 V. REFERENCES ...................................................................................................... ..............................4 FIGURE 1: REGIONAL LOCATION MAP FIGURE 2: LOCAL VICINITY MAP PROJECT PHOTOGRAPHS APPENDIX A: HAWKER - CRAWFORD CHANNEL APPENDIX A.1: EXISTING HEC -RAS ANALYSIS — SUBCRITICAL EXHIBIT " A " CURRENT FEMA FLOOD INSURANCE RATE MAP (FIRM) EXHIBIT "A -1" CURRENT FEMA FLOOD INSURANCE RATE MAP (FIRM) EXHIBIT "A -2" CURRENT FEMA FLOOD INSURANCE RATE MAP (FIRM) EXHIBITS "B" & "B -1 11 : HAWKER CRAWFORD EXISTING FLOOD PLAIN MAP EXHIBIT "C": NOT USED EXHIBIT "C -1 11 : NOT USED EXHIBIT "C -2 11 : NOT USED EXHIBIT "D ": PROJECT TOPOGRAPHIC MAP (1" = 200' AND 1 -FOOT CONTOURS) EXHIBIT "E ": TTM NO. 16325 AND TTM NO. 16326 (1" =100') Ma 2s, 2002 AEIOCASC ENGINEERING O:\word p rocessin&b r elated \734 - C oyote C anyon \73405 -LOMA for H awker C rawford C hannehReports and Studies\Coyote Canyon_Existing Capacity Study for Hawker Crawford Channel.doc EXISTING CAPACITY STUDY HAWKER CRAWFORD CHANNEL COYOTE CANYON SPECIFIC PLAN — FONTANA, CALIFORNIA I. PURPOSE OF STUDY Coyote Canyon LLC seeks the approval from the City of Fontana for the existing capacity study for the reach of the Hawker Crawford Channel located within the Coyote Canyon Specific Plan, specifically adjacent to TTM No. 16326, TTM No. 16325 -1, and TTM No. 16325 -2. The purpose of the study is to determine if the existing unimproved Hawker Crawford Channel has adequate capacity to convey the tributary 100 -year flows within the study reach. II. PROJECT SITE AND DRAINAGE AREA OVERVIEW The Coyote Canyon Specific Plan is located in the City of Fontana, County of San Bernardino, and State of California. This 323 -acre project site is roughly bounded by I- 15/Duncan Canyon Road to the south and east, the existing Hunter's Ridge development to the west, and the undeveloped hillsides to the north (see Figure 1). TTM No. 16326, TTM No. 16325 -1, and TTM No. 16325 -2 are located within the southern portion the Coyote Canyon Development, south and south east of Rich Basin, respectively (see Exhibit "E"). The Hawker - Crawford Channel is the existing major watercourse that impacts the proposed tentative tract maps. The Hawker - Crawford channel enters the project site from the northeast project boundary and traverses the site southwesterly before discharging into the Rich Detention Basin. The outlet channel for the Rich Detention Basin continues downstream and joins the San Sevaine Drainage system. The Hawker Crawford Channel poses a possible flooding threat to the proposed tentative tract maps previously mentioned. The ultimate facility improvements will alleviate the possible flooding i ssue, b ut t hey in ay not be constructed until some time after the development of the proposed tentative tract maps. Therefore, this study analyzes the Hawker Crawford Channel in its existing condition to determine the existing 100 -year floodplain limits. III. FLOOD PLAIN ANALYSES The analysis for the Hawker - Crawford Channel was performed with the Boss River Modeling System (RMS) HEC -RAS Module, and the United States Army Corps of Engineers "HEC -RAS 3.0" software. The RMS program allows a river model to be analyzed within an Autocad environment. The project topographic map was used to develop the cross sections (see Exhibit "D "). Analysis summary tables are included herein along with the input and output files. Prior to beginning the analysis for the Hawker - Crawford Channel, the hydraulic parameters for the stream were determined. The following is a list of parameters utilized to analyze the Hawker Crawford Channel: 1) Per the Coyote Canyon Master Drainage Plan (Reference 1), the Hawker - Crawford flow rate to be used for this study is 2,830 W /s. This flow represents a "Bulked" 100 -year storm event condition. A bulking factor of 1.5 was used. C January 9, 2003 AEI -CASC ENGINEERING O:\word processing\ ob related \734 - Coyote Canyon \73405 -LAMA for Hawker Crawford Chwml\Reportc and Studies\Coyote Canyon_Exisdng Capacity Study for Hawker Crawford Channel.doc EXISTING CAPACITY STUDY HAWKER CRAWFORD CHANNEL COYOTE CANYON SPECIFIC PLAN - FONTANA, CALIFORNIA 2) The existing HEC -RAS model used the following Manning's "n" value: Zone Description Manning ten" value Surface Channel 0.027 Earthen gravel channel North Overbank 0.032 Tilled soil with patches of vegetation South Overbank 0.032 Tilled soil with patches of vegetation 3) Starting water surface elevations for the subcritical model is based on critical depth. 4) For the most part, the sides of the main channel are protected with small cobbles and rocks. The banks extend above the adjacent ground, thus forming a levee condition. Since the south and north channel levees are not FEMA certified levees, the potential for levee failure exists. In an effort to model the worse case flood plain limits for the existing Hawker - Crawford Channel, a flood plain analysis was performed based upon the assumption that both the existing north and south levees will fail. 5) Two (2) culvert crossing, located approximately 200' south of Coyote Canyon Road and 480' north of Coyote Canyon Road, exist along the study reach of the Hawker Crawford Channel. These crossings are composed of a depressed or "sag" roadway across the channel with triple -36" corrugated metal pipes (CMP) culverts for low flows (see project photographs). The triple 36" CMP culverts were modeled with approximately 6- inches of debris deposited in each pipe. IV. FINDINGS The results of the existing flood plain analysis for the Hawker - Crawford Channel indicate that if the a xisting 1 evees fail, t he n orth a nd s outh o verbanks o f t he H awker C rawford Channel will become inundated. These flows will overtop the existing Coyote Canyon Road and proceed southwesterly through the project site. The overbank flooding will consist of shallow flooding typically one foot or less in depth. The shallow flooding within the south overbank will reenter the Hawker Crawford Channel before it discharges into the existing Rich Basin. The proposed pad elevations adjacent to Rich Basin and the Hawker Crawford Channel will be elevated a minimum of one foot above the existing base flood elevation (see Exhibits `B" and `B -1 "). In summary, the detailed study shows that the existing Hawker Crawford Channel will convey the 100 -year storm flows with the associated floodplain. The proposed TTM No. 16325 -1 and TTM No.16326 will remain outside of the 100 -year flood hazard while portions of TTM No. 16325 -2 will remain within the flood plain area (see Exhibit `B" and `B -1 "). Only those areas of TTM No. 16325 -2 that are located outside of the 100 -year flood plain can be developed prior to January 9, 2003 AEI -CASC ENGINEERING O:\word processing\ ob related \734 - Coyote Canyon \73405 -LAMA for Hawker Crawford Channel\Reports and Studies\Coyote Canyon_Existing Capacity Study for Hawker Crawford Channel.doc EXISTING CAPACITY STUDY HAWKER CRAWFORD CHANNEL COYOTE CANYON SPECIFIC PLAN - FONTANA, CALIFORNIA the construction of the ultimate improvements for Hawker Crawford Channel. V. REFERENCES 1. AEI -CASC Engineering: Master Drainage Plan for the Coyote Canyon Specific Plan, April 2002. 2. AEI -CASC Engineering: Conditional Letter of Map Revision for the Coyote Canyon Specific Plan, Case No. 02- 09 -411R, April 2002. M C --- January 9, 2003 AEI*CASC ENGINEERING O:\word processin&b related \734 - Coyote Canyon \73405 -LAMA for Hawker Crawford Channel\Reports and Studies\Coyote Canyon_Existing Capacity Study for Hawker Crawford Channel.doc A FIGURE L• REGIONAL LOCATION MAP m r ; UQ u . 2 O I RANCHO I CUCAMONi ONTARIO E CHINO r----- - - - -- ti j 15 1 ♦ CORONA Vw If & aD Norm Coyote Carryon Specific Plan City of Fontana RIALTO FONTANA ► "TTY�I7 Regional Location Figure 1- I SAN REDLANDS tDINO CO. MORENO ,VALLEY 1 -3 m FIGURE 2: LOCAL VICINITY MAP Figure III- I ■ . ww�� a r.ei ■ ■ a� SAN B pi :�. N a 2 L w F w r r m FONTANA SPHERE OF INFLUENCE A i I 1 I �J I o D a o 'a z COYOTE CANYON SPECIFIC PLAN AREA Vicinity Map J �y \ �1 W � North Coyote Canyon Specific Plan City of Fontana III -2 m PROJECT PHOTOGRAPHS LETTER OF MAP AMENDMENT COYOTE CANYON - FONTANA, CALIFORNIA 0 Hawker- Crawford Channel looking upstream, north of Coyote Canyon Road. Typical Hawker - Crawford Channel overbank. May 21, 2002 AEI•CASC ENGINEERING 0Aword processing \job related \734 - Coyote Canyon \73405 -LOMA for Hawker Crawford Channel\Reports and Studies \Coyote Canyon_LOMA.doc LETTER OF MAP AMENDMENT COYOTE CANYON - FONTANA, CALI 0 Hawker - Crawford Channel culvert crossing E Hawker - Crawford Channel between culvert crossings. May 21, 2002 AEI•CASC ENGINEERING O: \word processing\job related \734 - Coyote Canyon \73405 -LOMA for Hawker Crawford ChannehReports and Studies\Coyote Canyon_LOMA.doc north of Coyote Canyon Road. LETTER OF MAP AMENDMENT COYOTE CANYON - FONTANA, CALIFORNIA 0 Hawker- Crawford Charnel culvert crossing Hawker - Crawford Channel looking downstream, inlet of Rich Detention Basin. Ma 21, 2002 AEI•CASC ENGINEERING O: \word processing \job related \734 - Coyote Canyon\7 3405 -LOMA for Hawker Crawford Channel\Reports and Studies \Coyote Canyon_LOMA.doc south of Coyote Canyon Road. C APPENDIX A.1: EXISTING HEC -RAS ANALYSIS - SUBCRITICAL LM m n'e O M N O O M n O M v m (O O O 0 m� 0 n m m m m M n 1` O m O o (O CO CO O O O O CO CO O O m m L U O O O O O O O r O O O O O O O O O O O O O O O O O 7. O ll. n c0 n n n N M N Co O O (O m O st O T Cl) m 0 m m N r (D O r N M 0 'I7 N T O O q CM O M M O T O Cn 00 O o n .p r to M r.- o O O N M 0 O O N O M 0 0 M� w m o O CO d' n M 0 N M O N O m O T m N O M m Cl) N M M CD m O M (D O r 0 00 0 00 0 00 CO co M to N N m T m 12 w m n O M n N n v n CO 00 n O O N V co N M n m M 0 to CO CO CO M CD M N T T at (O M r ((7 T N CM m n CM Cl? CD n O--t O m m cO N_ O (D (0 n CO co N_ n m N co N It co N n O O N 00 n N M et m M O c0 CO m Q co V 'at � co O n N CO O O It (D n n N N n 00 co n n CO CO N N O LL N O m N co N M m T M O co Cl) O O m N n n 0 CO M CD r n OO CO M O r._ T r OR Cb (D n T O co O M 00 't M O ' 0 h co Co 1.: n n (() Cn CD co co n n n o r Co Co n n (D n 00 0 U � a� Cp M O N n T (D M N CD co co 00 N CO O n 0 m CO 'a O n y n T m M m T (n m rn O w 9 m n m O n 0 N m 0 O O O v N (o O O m N (n 0 G d' 00 co CO m u7 r CO o O M N M M O 0 0 N N M CO N (D n (n O M O o CO O m O 0 O O v O v N N O O LO O O O O O O O O O O O o O O O O O O O O O O O O O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C. 0 �. w m n M O O n O m 0 m a0 CO n 0 N m m co M CO301 (f) m > n 00 T O oo O h M m Coo T" 1� N Ut M n (n M M M N m 0 N " O CO n m N 1` (D M N m T CO � M 00 M O M O O N M N n O lO M M N N N � r 0 0 O m a0 O n O (n M N m n n n n n n n n n n n n n n m c0 (D c0 m c0 0 0 (D c0 T T r T T r T T T T T T T T T T T r T T r T T LO ' O M N d' O (O o m m O N n O N O O (O (O m y N N CM M� m M m (O N a m n m m N� 00 O OR O M M O CO , 0 Co Co 00 CO - CO CV CV M o_ W) M N r- 0 m N --t (O M O v v M M N N N O O O m 00 n n CO Cn t M N _O > n n n n n T n n n n n T n n n n n O CO (D CD CD O CO (D (D O O M N '7 0 0 0 m 0 CO N n O N O co (O (D m y. ,. N Cl! M Cl) m M m CO N V m n m ao N o O 0 c0 CO M O V V ,'' ((1 to Co 00 Co r M M N 0o o W) M N 1.- 0 m N CO M C W n to (n v a M M N n N n N n T n O 1- n O n O n m (D M (D n (D n O CO CD CO m N vI �n T r T r T T T T r T T T T T T T T r r T 0 0 0 0 0 0 0 0 0 Cl) O O m 0 0 0 0 0 0 0 0 0 0 0 0 '. OU� O O O r n r r N T O m n (D O O (O O r n 0 0 0 0 O N M h N o o w 1` M Co CA t- CO M T M Co Oo CV 00 M CV n CO O V M M N N h P O m m m m n n (O O <t -7 N O U n n r n T n r n r n T n r n T T T 1� T n T O T O T CO T CD T (O T co T CO T O T CO T CO T (D T (O T O c_ ... T 0 0 0 C. 0 0 0 0 o r o 0 C. C. o r o 0 0 0 0 0 0 0 0 0 0 O O O 0 O O O O 0 N O O 0 0 0 N O O o O O O O Cl O 0 O ' o 0 o O O O O O o ? 7 O o o M O M CD M ? 7 O M O M O M O M O M O M O M O M O M C M O M O N M 00 M O M 00 M O M O M a0 M (O M tO M 00 U M M O CO („) O O O O O O N N N N N N cq N N N N N N N N N N N N N N N N N d v co > O O O O O O O O O O O O O O O O O O O O O O O O '�. 00 c0 c0 c0 (A O CO CO T m n CO O O OM T m Y O m O T m� 0 (0 0 0 M (O O et 0 et at N d' O �' O M O M n co n M co M 'q M N M T M T co o co m N 0 N N N O N n — OM T O T T n PM V Y T T T T r r T T T U U U U U of U to U N U C0 U U N U C0 U N U (0 U (0 U N U N U t0 U N U U l0 U (0 U CO U (0 U CO U CO U U (0 (0 t0 (0 CU CU N CO 0 d N CU N N N d N lU fU 0 fU d 0 0 N CU N 0 lU (U N C0 0 N 0 m w J CO ;(n m !z ? y i W i W CO co Cl) C/) m m z Cn � W W fn U o.. @ 4 a J m o 0 0 N C Co a3: 0 LL -- - - J p W Y Z J 0 r Q m } 00 O LO O 11 LL (n Z H CO U W M ° o z W 0 co Y u- n Q J U = W � I �p U J cc LL Q ? � r o 0 CD Z Z 0 F- z W 0 O O N o C. r O O O co O co (D d' N O r ti (u) u011en913 N IN= m m! J ;m (n m Z i (n i W iW i w m m U) U) M Z +Z U) U) W W U c O CD w m v) D c m 0 0 0 C (6 00 IL J LL J p W w Z Y Z Q m M O r 0 } C O O II U- U) Z F- c j UW*a N L t L U O N YLL� u = Q N Il m 0 -- - - -- ; - _ - - - - - - - -- - - - - -- -- - o c o = w v r _ j 4k L to W J U Q Z Q' O o o C9 Z Z Ocn Z X Q w U E W 4) o 0 f— c7 N r O O U 0 0 r 0 0 c m m 0 (D co co to r r r r r r r r r (4) u01jenel3 Lq im i m CO D U) N C C7 0 c y f4 iz z +z o' a>i�c m X W W W 'w U) U o 0 c CD CID LL ' J p W Y N Z � o Q in 2� V W o p }co � 0 io O Z DO UW L w 3 m W ° I o LL o - - - — -- - - - - -- - - - �o > Y� > It -- -- - - - - - - 2 a m LL N W m o 2 W 7k to L O J N O LL z O a�it � o CD zZ O1-- Q W N U E N } U 0 0 0 0 LO LO LO LO LO 0 co CN LO LO LO (u) u01leAG13 O A ;m :> m m ;N m cn im m m CD v) Cl i Z Z+ Z o J fn N - i co m i W X . X W W i W CQ Z U o 0 c Cc d 3: 0 LL N cn ' J O W W z Q m 2 � O � o v o 0 ° u U- () co Z N o > U w Y i° g co - - -- - --- - - -- -' - - - v U- N �_ = W J O N W J v 0 QZ o 0 -i zZ o� Q w N U E W a) N - - -- - - Q M -- U 0 0 0 0 LO LO v v 0 v �� (u) u04en913 C�] c C7 ;z X iW w C7 C7 W W N .0 c y in m o 0 m C M (p O 0 0 O J p LO W Y am o }CD It o °f LL � c) o 0 Z Uwx� t W p y Y u If - - - - u < LL om' N cn LLI W . J tL7 L z C Q C i N O Z z N O ��„ Z X Q w U E - - W a O N- o - - -- -- - - - - -- U o 0 0 0 n 0 Cl) M ce)� n (4)u01len913 a ;U) U .U) m m m 0 z z +Z c p in c -i � CO ( C7 N m X . W W W iw N 3 :U O O N N C CO O LL -- -- - - - - - - - - - + - -- - - O o J 0 N W Y Q m 2 � D N O O II O LL co Z r Cn W t U Q . N > Y 11 Q M - _. - - -' --- - - - - - - O LL (D CA -' i C CO = W w _ # Cn W U J Q z I 2 N O J z °� Z r Z W 0 E N M W d N O O O to O O O L6 O r to to V Cl) M (u) UOI IEA913 Lq CO m m m a !z z +z J i C/) fn Cn ! W W W i C D j W U) '= U O O N N C Co -- O O N J O W Y Q m 2 � >- CO C) O ° u LL Vr (n U X it W z U f0 w u 2 a m v LL N = - - - - i -- -- - f - --' -' - - o W W cLi J N O Q 5 l O (7 Z Z ° O OF co Q W F- CD O N co U C, N O O M Cl) Cl) co Cl) O N N N (11) u01len913 u r� c a m ) CD J i Z U) i W Z +Z fn L W W cn _ c @ m 0 C. 0 C LO - - -- - - - --- - - J U. O W W Z Cl) Q m °• U , W Ors O co O II u O > H r NO W L •• U f0 W Y LL Q' - - j ---- -- - --- -'- -- --- - - --- - --- --- --- -' - - - -- - - -- - 11 i U L N v LLJ O W W t fn J U f L6 Q Z 2 O O Z Z O p O ~ N W O Q U E o O� U p o i i 0 0 N CD N In 7 M N N N N N O N N r ~ r r r r r r r (4) u01leA913 m m i .\ 2 .$ .j .E \ \ } } } U U w :j \ \ \ _\ ® \ m / k -- � - - -- -� - - - - - -- - - - - � / CN R - -- -- - - - -- - - - - -- .- -- - - - - -- - -- z § : } § k � Q i < C) C' 0a]1 /2� Cl) w \ m / ƒ � - --- «�§ - - -- - - -- -- -- ! - ; -- - - - - - - -- -- - -- / I E ®�k \ . m Eck . . L2) . / R ! § > qcƒq C) ° 0 * ® . Z X ' LU / -- - - -- - - - - - -.. \ e -- - -- - - -- -- -- - - — { . - -� -- - - �- S g = o 04 p o o\ C%4 p p p p U p a A W J co U) 'm CD ; Z ! y j W W CO CO N :U) CO CO 0 C7 Z +Z c N W W U c a tt CO •Y _ c Ql 0 0 c tB d 3 O o J p Y O Z a •- Z :D m N G < C) } rn O M Q it LL Vr N Z 1- Cl) _ W it o L 3 m O W Y LL IX LL N = W W J v U_ Z =O a o 0 C� N N z Z o 0 F- z Q W m 1 } U 0 0 N N N N N 0 O tD (u) u01lenal3 N Mo OR J CO ;> ;C im co Z fq W iw CO m U m m c� Z + Z N (n W W CO U = o ' 0 > J �Y C (0 m o 0 c Im CL O LL ---------- J C) Z Y Q m 2 of Q U W rn O M N O II Z u) 'ties. H 57< L °o r it > Y W U) o = W W # L «p N W O J (7 a) Z Q n o 0 O 0 of -j c� Z z LO O � o a Z X Q w U E W aa) C7 O ° o U r 0 0 c0 N O 0 a0 O r (u) u01;eA913 M C1 J m ? CA i W iW LM CO Cn U) Z +Z L L W W 3 .0 O` a) J � cn C•a m co Co o u� C CD - LL J p � ° C) Z Y v am U W C:) M N LL Z H q cf) LL W it O L o W u Q J L U LL- -- - - - .. - - - - - - - -' -- - -- -- - - - � W w o .m = W UJ W CO J V L of Q Z o O 0 Z Z O N M o Q W U E LLI c a) O 0 0 N N N N 0 r (u) u01;en913 a ;m cl) im Z W W m m U) cl) m :m Z +? p W W ca : C� m m 0 v c Co a. O i LL N M Y O O Z c Q m 2 w Q D >- m R o M O 11 LL Z N Q H cn U W o O L f0 w CN — U _ LQ N - ._. W m o = W j # ip co d' W L J U Q � Z ° o Q n O O M O Z ? o CO zW Q U E H - O o 0 0 O N O O (D tf> M O (u) UOIIEA913 m m J u) m ; Z ! W 'W .� m m Z ±Z W W U :3 �Y c — N m o 0 au C co CL - - -- - � o J p - CO W W Z Y Z J = Q N co � Q p } o O M O II O Z r UW t W U u U � LL (D i O O W I- W r W J tL) Q Z Q' O Of Vr N U Z? o ° o O ►— ° Q W U E LLJ a) O } O U o 0 o 0 c0 st N O 0 CO CO CO O O (u) UOIIEA91 x c im (� W i W Z) U) m m C7 C7 W W U c to CO cc 0 0 co c m 0 LL -- 0 J p W W Z Q m Cl) _ � o ° o p } M o r II Z Q' o N X o w N L U O w Y ti - - -- - -- i - - d U- W '- --- -- - --- .. -- i �-- - -- - -- -- -' - ' --- -- -' -' - - --- - -- -- --- - - - '--- -- - - - -- - - - -- - - O 0 O CD W _ 7# w W v U) O J Z � Q 5 11 O `m O N Z o0 Z p ►- op a W 0 U 0 0 co 0 0 0 0 v n o (4) uoi;enaIB N m J m iZ co W W co cn m m C� Z +Z C/) w W N .0 c o vn COY _ c m m O 0 0 c co 0 LL 0 0 J p W W Z Y N m Q = Cl) � p } Cl) O M O 11 U- co O O Z Uw t U Nr• I f0 W n U = N � O LL F � It J U Q Z O d OJ (D Q' N CD Z Cl) ° o O O ZQ W - W a0 i H � U o 0 0 0 0 r- r- o co to co (u) UOIMAGJ�3 A m J ;m m Z U W ! W m U) CO m Z +Z � W W N U - m 0 0 0 Co O LL '---- -- -'-- -- -- -� --- - - •- --- -- -- - - - - -- ' '- -' - - --- O J p co w w Z Y m Q = N M Ix O Q } O � LL co O Z X r w N ^ L X cc w p = N LL = w -- - - - - - - - -- - - - ----- - ' - - --'- - - O O r I t w J U � Q O J O of N Z Z ° o O o z w° CD — O U O 0 0 0 0 ^ ^ o 0 0 (4) U014en919 ;m m m m ;m m CO co m Z Z +Z p �Y j � (7 c — l0 m w X X W W W .0 o 0 N N C (0 CL — — 0 LL.- - . -_- __ -_ _ _ - .,.- . - -. ... - - _.- - . - _ _ . - -. _ _ _- -__- - __ �. _ - _ - 0 Co J p N W Y Z Y Q m 2 Of p w 0 0 M O M O 11 O U- C9 cn O > Z aD >� F— UW� s uj 3 m W o m Y LL of --- - - - - -- -- - - - -- - II N o m = _ N O W L J V Q I G 0 4I O Z Z ° o O } CO Zw Q .. U 00 0 --- - - - - - -- -- - - - -- - - - -- - - - - W d } U 0 N O O O O O 0 O O) O r (4) u01leA913 C�] C ;m U) O Z U) W i W m m � O C7 Z +Z cn in W W N :3, Vr C/) � Y c t0 m 0 0 N N C t0 CL ?� LL O J p - -- -- - -- -- -- - - -- - - - - - - -- - -- - - - -- CD N WW Z Q m 2 m U Q M D rn R� O Cl) o II j O Cn O O Z Z ° r rJWit L Y L it n No Q J L N _.. _ - _ _. _..- _ _ _ _ _ - O LLL = - -- - -- - - - --- - - - - - - — C O W N J U LL Q O I O O Z Z ° o OF U) zW W (D O U o 0 N r O O O O O O O) O (u) u01;eAG13 m 4) J cn 'm I Z : cn W iw CO CO U) co m .m Z+ Z N CO W W N 3: 'U 2 J C• f0 m 0 0 c c0 N 0 EL O Cl) O LL J p W w o Z J Q m 2 it U w o oO N O Q II LL Z of -2, ,7- F Q Cl) U X i W o .. L U t O o >YLLC W y o o = w W it cn Q' W t U- J U U- Z Q II 0 O 0 J N Z Z 0 CO Z W Q i W CD 0 0 U 0 ° 0) c c c (4) UOIIBA913 A M :> CO .m > .Z) ;c) .cn im m :m w J !� cn cn Ur J f0 CO iW W W ! W CO 3 U 0 0 0 N C _N � LL., _ --- _- ._ ._ _. _ —___ _ __ ._ _ _.. - -_.___ _. _ _ _ ___. ------ _- O J p W w Z J Q m o 2 I Q cl >- O N O 11 LL Ur UW it t w Y LL -- -- -- - u r• 2 Q m o O LL G7 C mw W j CO W L J V Q Z 2 0 J O 0 C7 Z Z N OF Q W N U E O W aa) CD U o 0 0 0 00 o 0 D c n c r c too too co o (U) u01len9l3 A 4 J ;m !Z) iU) m Z co ;W W W m m D D U) m m Z +Z N L W W .0 N c in � (� N m 0 0 0 N C f0 D.. 3 O J- LL - -- -- - --- -- J p o Z J co Q m _ of Q p } rn o N O2 O II L Ur (n Cl) > Z N N (� w L o coo W o 4) Y LL Q J L — U LL N . . W y o = W j jp U) W v J � � n p Q D - 0 O a) � lY Z Z Z W W aa) U o 0 0 0 co o ° co r.- ° •- co co co co co co co (11) U0I12n813 m C7 x = a J im U im cD ;Z ; fn i w iW U) m m cn m m C7 C7 z +z Cn co W W :U c U � in J m o 0 O C Cc CL LL J p W W o Z -j ro Z m N O p�. O N O II LL c� N _Z co U W L o O O > YLLOf aJ� _ LL -- a) W m Q� o 0 2 w F' j Q' L to W 0 J U p a� Ca Z G O 7 o 0 2 Z Z O� >- LO N Z M w a O U E LU c� O I U 0 cl 0 04 m coo co m (u) U01;en913 m � "� '� m m m @ ° c c m C7 !Z C7 C7 Z +Z in o�c J i Cn (n C7 , m W W W W w co 3: U o 0 0 c Co O LL - - - W w o Z Y Q m N Q 0 w p M O O � O � 11 LL(� Z Ir q � N LC H UWL o Lu 3 m fO LL i ---- - -•-- - - - - - > Y = a w o 2 w F- > w n cn J U O N p Z � 0 II o N O � Z Z ON Z X w Q U E N M W d Q O O - p N U 0 m c2 c c coo Ln LO (U) u011en913 .I •r° L LM—' Co CO co N C0 ct) c im m m ca c in m C7 iz CD (D z +z o � J j Vr o m iX W W : W 3 U o 0 N C f0 d - -- — -- - - - - � LL O O O J p W W Z Y Q m = tr p }� O r N Q II M O O Z W q � LL C/) U w t Y - - u = Q m LL v N W_ __ .. ___ __ - _. _; - -_ _ __ _- _ _ __ -. -._ __ _._____ ____- _ - ... _ __. - __ - -- _ O C O g CD = W td W O J N O z Q I 2 O N Q Ix of Z? O pCO v Q W U E N -- W o U °o N O co Co C � 00 co co r (u) u01;en913 C �I L m J ;m U) Z i cn W i W m m U Z z N N W W N 3 U > �'� m 0 0 rn c c0 0 EL co O J LL WW Q m _ it O Q } L O O O II U- Z q � U W 0 0 r W o a Y IL u o Q J t U = LL N W -'- -' +- - - - - o 0 = W � # @ W v Cl) J O o Q D it O >_ o 0 Z Z O� a W (, M O O n O O N O O O co h (O C'7 N r C r C r C C C r r r (0 co r r (1j) U01leA913 COYOTE CANYON- LOMA FOR THE HAWKER CRAWFORD CHANNEL Plan: Geom: EXISTING GROUND LEVEES FAIL Flow: EXISTING 100 YEAR BULKED FLOW River = Reach #1 Reach = Reach #1 RS = 710 < .027 i< .027 + .027 4 1644■ Legend - EG EXISTING (B) SUB WS EXISTING (B) SUB 1642 .............. ' Crit EXISTING (B) SUB - ... Ground • Bank Sta 1640 - ... , 1638- , • c o .= 1636- , co m w 1634- 1632 : , ii____ , . 1630- , - , 1628 100 200 300 400 500 600 Station (ft) O A A -j p i U) i m ?Z ? co X W i W p p U) U) m m Z +Z T L W W U o, cu cc m 0 LO M G IL O J LL. - - J p o w o Z J M Q m 2 � >- p L LO R � o v o n U- Cr z W 0 U 3 LO N w Y F of Q J U .. Li N w o 2 W W O �o fA W c O J N LL p Q D N O ' J � � C9 Z z O f' In Q W CCD - - O >- 0 LO U N O O O M M N N T (4) U011BA913 m ;m m m 'C/) CO .Ct) c C9 C7 : C7 c y CO z z +z o a'>�c J 1 cn UJ En CD J m W W W i W U 0 a7 N C CO o a � N 0 N O ( J J p W Y Qco o N U w p >- c �ocn 0 o n LL z ~ U� - - o U W L N r U a7 Y F L [Y CV N > if O Q J U Q N 11 f 2 W ° � U) W U O -' 0 LL Q Z n 0 o o f C7 R O J C9 Zz 0 Z X Z W W aa) O O N Co r O O o O O O e (D O (D (D (u) u01len913 PROJECT DATA Project Title: COYOTE CANYON- LOMA FOR THE HAWKER CRAWFORD CHANNEL Project File : H_C_FLOODPLAIN EXISTING_B.prj Run Date and Time: 10/25/02 1:25:28 PM Project in English units PLAN DATA Plan Title: Plan File : q: \73405 \HEC RAS\ EXPORT \H_C_FLOODPLAIN_EXISTING_B.PO1 Geometry Title: EXISTING GROUND LEVEES FAIL Geometry File q: \73405 \HEC RAS \EXPORT \H_C_FLOODPLAIN EXISTING_B.GO1 Flow Title EXISTING 100 YEAR BULKED FLOW Flow File q: \73405 \HEC RAS\ EXPORT \H_C_FLOODPLAIN_EXISTING_B.FO1 Plan Summary Information: Number of: Cross Sections = 25 Mulitple Openings = 0 Culverts = 2 HEC -RAS Version 3.0.1 Mar 2001 Bridges = 0 Computational Information U.S. Army Corp of Engineers Water surface calculation tolerance = 0.01 Critical depth calculaton tolerance Hydrologic Engineering Center Maximum number of interations = 20 Maximum difference tolerance 609 Second Street, Suite D Flow tolerance factor = 0.001 Davis, California 95616 -4687 (916) 756 -1104 X X XXXXXX XXXX XXXX XX XXXX X X X X X X X X X X X X X X X X X X X XXXXXXX XXXX X XXX XXXX XXXXXX XXXX X X X X X X X X X X X X X X X X X X X X X XXXXXX XXXX X X X X XXXXX PROJECT DATA Project Title: COYOTE CANYON- LOMA FOR THE HAWKER CRAWFORD CHANNEL Project File : H_C_FLOODPLAIN EXISTING_B.prj Run Date and Time: 10/25/02 1:25:28 PM Project in English units PLAN DATA Plan Title: Plan File : q: \73405 \HEC RAS\ EXPORT \H_C_FLOODPLAIN_EXISTING_B.PO1 Geometry Title: EXISTING GROUND LEVEES FAIL Geometry File q: \73405 \HEC RAS \EXPORT \H_C_FLOODPLAIN EXISTING_B.GO1 Flow Title EXISTING 100 YEAR BULKED FLOW Flow File q: \73405 \HEC RAS\ EXPORT \H_C_FLOODPLAIN_EXISTING_B.FO1 Plan Summary Information: Number of: Cross Sections = 25 Mulitple Openings = 0 Culverts = 2 Inline Weirs = 0 Bridges = 0 Computational Information Water surface calculation tolerance = 0.01 Critical depth calculaton tolerance = 0.01 Maximum number of interations = 20 Maximum difference tolerance = 0.3 Flow tolerance factor = 0.001 Computation Options Critical depth computed at all cross sections Conveyance Calculation Method: At breaks in n values only Friction Slope Method: Average Conveyance Computational Flow Regime: Subcritical Flow FLOW DATA Flow Title: EXISTING 100 YEAR BULKED FLOW Flow File : q: \73405 \HEC RAS\ EXPORT \H_C_FLOODPLAIN_EXISTING_B.FO1 Flow Data (cfs) ****************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * River Reach RS *EXISTING (B) SUB * * Reach #1 Reach #1 5480 * 2830 * Boundary Conditions 1 * * * # * ** * * *aF * * *k kkk******# fr******** kk* x** xxlr**** 1r** 1r* 1r* xk* rt*********** * *x * * * * *x * * * * * kk * * * * * * * * * * * * ** *kk* * River Reach Profile * Upstream Downstream * k *k* * Reach #1 Reach #1 EXISTING (B) SUB * Critical * xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx k * ** GEOMETRY DATA Geometry Title: EXISTING GROUND LEVEES FAIL Geometry File : q: \73405 \HEC RAS\ EXPORT \H_C_FLOODPLAIN_EXISTING_B.GO1 CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 5480 INPUT Description: Station Elevation Data num= 36 * Left OB * Channel * Right OB * • Vel Head (ft) * Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev k********* k**k******************* • Crit W.S. (ft) * * * * * *k * *k * * *k * * * * *k * * * * * * * * * ** *kkk * * * * * *k * * * ** 1000 1777 1101.57 1776 1113.47 1776 1126.77 1776 1129.36 1776 1167.56 1776 1169.1 1776 1223.44 1775 1234.57 1775 1240.9 1775 1345.55 1774 1351.97 1774 1399.41 1774 1401.46 1773 1404.24 1772 1408.74 1771 1412.67 1770 1420.62 1770 1421.36 1770 1425.57 1770 1431.11 1771 1435.2 1772 1442.4 1773 1544.63 1774 1548.9 1774 1555.23 1774 1578.12 1774 1609.54 1774 1639.11 1774 1657.88 1774 1687.2 1775 1719.12 1776 1750.74 1777 1775.19 1778 1797.09 1779 1818.33 1780 * C & E Loss (ft) * 0.02 * Cum SA (acres) * 20.38 * 10.33 * 27.80 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .032 1399.41 .027 1442.4 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1399.41 1442.4 286.25 293.19 307.36 .3 .5 Left Levee Station= 1399.41 Elevation= 1774.01 Right Levee Station= 1442.4 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB * * * * * *x * * * * ** kkk * * * * * * * * * * * * xx * * * * * * ** kkk**** xk**** x************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • E.G. Elev (ft) * 1775.79 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.59 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1775.20 * Reach Len. (ft) * 286.25 * 293.19 * 307.36 * • Crit W.S. (ft) * 1775.20 * Flow Area (sq ft) * 142.80 * 173.88 * 331.30 * • E.G. Slope (ft /ft) *0.003478 * Area (sq ft) * 142.80 * 173.88 * 331.30 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 326.76 * 1412.33 * 1090.91 * * Top Width (ft) * 481.17 * Top Width (ft) * 186.93 * 42.99 * 251.24 * * Vel Total (ft /s) * 4.37 * Avg. Vel. (ft /s) * 2.29 * 8.12 * 3.29 * * Max Chl Dpth (ft) * 5.20 * Hydr. Depth (ft) * 0.76 * 4.04 * 1.32 * * Conv. Total (cfs) * 47987.1 * Conv. (cfs) * 5540.7 * 23948.3 * 18498.1 * Length Wtd. (ft) * 298.67 * Wetted Per. (ft) * 186.95 * 43.92 * 251.27 * Min Ch E1 (ft) * 1770.00 * Shear (lb /sq ft) * 0.17 * 0.86 * 0.29 * Alpha * 1.98 * Stream Power (lb /ft s) * 0.38 * 6.98 * 0.94 * Frctn Loss (ft) * 1.52 * Cum Volume (acre -ft) * 24.39 * 29.03 * 23.72 * C & E Loss (ft) * 0.02 * Cum SA (acres) * 20.38 * 10.33 * 27.80 Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross kov section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates 2 that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 5180 INPUT Description: Station Elevation Data num= 40 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 1767 1061.4 1767 1210.45 1767 1232.75 1767 1284.52 1767 1284.53 1767 1333.61 1766 1359.74 1766 1363.93 1766 1366.94 1766 1370.26 1766 1393.8 1766 1396.22 1766 1398.5 1766 1401.78 1766 1404.88 1765 1409.1 1764 1412.58 1763 1415.87 1762 1418.6 1761.5 1432 1761.5 1435.28 1762 1440.92 1763 1446.2 1764 1469.13 1765 1484.6 1765 1504.6 1764.5 1508.6 1764.5 1534.6 1765 1600.6 1765 1629.34 1764 1635.25 1764 1639.59 1765 1662.22 1766 1670.98 1766 1679.29 1766 1689 1766 1694.3 1766 1714.02 1767 1744.64 1768 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 .032 1359.74 .027 1469.13 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1359.74 1469.13 295.36 300.45 287.94 .3 .5 Left Levee Station= 1359.74 Elevation= Right Levee Station= 1469.13 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB • E.G. Elev (ft) * 1766.87 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.64 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1766.23 * Reach Len. (ft) * 295.36 * 300.45 * 287.94 * * Crit W.S. (ft) * 1766.23 * Flow Area (sq ft) * 7.40 * 206.70 * 270.59 * • E.G. Slope (ft /ft) *0.008113 * Area (sq ft) * 7.40 * 206.70 * 270.59 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 10.48 * 1557.96 * 1261.56 * * Top Width (ft) * 376.68 * Top Width (ft) * 37.54 * 109.39 * 229.75 * * Vel Total (ft /s) * 5.84 * Avg. Vel. (ft /s) * 1.42 * 7.54 * 4.66 * * Max Chl Dpth (ft) * 4.73 * Hydr. Depth (ft) * 0.20 * 1.89 * 1.18 * * Conv. Total (cfs) * 31419.0 * Conv. (cfs) * 116.4 * 17296.6 * 14006.0 * * Length Wtd. (ft) * 294.78 * Wetted Per. (ft) * 37.54 * 110.24 * 229.92 * * Min Ch E1 (ft) * 1761.50 * Shear (lb /sq ft) * 0.10 * 0.95 * 0.60 * • Alpha * 1.20 * Stream Power (lb /ft s) * 0.14 * 7.16 * 2.78 * • Frctn Loss (ft) * 2.20 * Cum Volume (acre -ft) * 23.89 * 27.75 * 21.59 * • C & E Loss (ft) * 0.05 * Cum SA (acres) * 19.65 * 9.81 * 26.11 * **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 4880 INPUT Description: Station Elevation Data num= 47 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 1759 1014.39 1758 1057.77 1758 1060.28 1758 1184.73 1758 1187 1758 1195.49 1758 1195.53 1758 1204.6 1758 1248.73 1757 1285.09 1757 1291.78 1757 1316.61 1757 1336.29 1757 1339.25 1757 1342.02 1757 1349.79 1757 1364.4 1757 1368.02 1757 1370.76 1757 1373.55 1757 1376.62 1757 1378.42 1756 1380.96 1755 1381.29 1754 1384.18 1753 1391.28 1753 1396 1752 1413.05 1754 1420.07 1754 3 1420.08 1754 1438.6 1754 1442.29 1755 1464.88 1755 1470.89 1755 1474.15 1755 1478.15 1755 1493.82 1755 1506.56 1754 1521.45 1754 1563.8 1755 1569.52 1755 1572.97 1754 1575.64 1754 1582.38 1755 1623.74 1756 1666.73 1757 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * ** * * * ** 1000 .032 1364.4 .027 1442.29 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1364.4 1442.29 270.46 273.68 286.87 .3 .5 Left Levee Station= 1364.4 Elevation= Right Levee Station= 1442.29 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * ** * * * * * * * * * * * * *** • E.G. Elev (ft) * 1757.13 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.81 * Wt. n -Val. * * 0.027 * 0.032 * • W.S. Elev (ft) * 1756.32 * Reach Len. (ft) * 270.46 * 273.68 * 286.87 * • Crit W.S. (ft) * 1756.32 * Flow Area (sq ft) * * 175.00 * 270.87 * • E.G. Slope (ft /ft) *0.006890 * Area (sq ft) * * 175.00 * 270.87 * * Q Total (cfs) * 2830.00 * Flow (cfs) * * 1532.10 * 1297.90 * * Top Width (ft) * 259.57 * Top Width (ft) * * 64.44 * 195.13 * * Vel Total (ft /s) * 6.35 * Avg. Vel. (ft /s) * * 8.75 * 4.79 * * Max Chl Dpth (ft) * 4.32 * Hydr. Depth (ft) * * 2.72 * 1.39 * * Conv. Total (cfs) * 34094.8 * Conv. (cfs) * * 18458.2 * 15636.7 * * Length Wtd. (ft) * 276.83 * Wetted Per. (ft) * * 65.96 * 195.41 * * Min Ch E1 (ft) * 1752.00 * Shear (lb /sq ft) * * 1.14 * 0.60 * • Alpha * 1.29 * Stream Power (lb /ft s) * * 9.99 * 2.86 * • Frctn Loss (ft) * 2.24 * Cum Volume (acre -ft) * 23.87 * 26.44 * 19.80 * • C & E Loss (ft) * 0.04 * Cum SA (acres) * 19.52 * 9.21 * 24.70 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 4680 INPUT Description: Station Elevation Data num= 39 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 1000 1751 1018.44 1750 1023.4 1749 1031.36 1749 1051.74 1750 1060.51 1750 1060.52 1750 1062.09 1750 1215.9 1749 1228.36 1749 1282.05 1748 1285.44 1748 1288.25 1748 1306.77 1748 1312.18 1748 1313.24 1748 1316.39 1748 1317.81 1748 1318.49 1748 1324.98 1748 1331.53 1746 1334.37 1745 1336.55 1744 1342.99 1744 1347.29 1744 1353.46 1745 1359.41 1746 1364.41 1747 1369.41 1748 1459.02 1748 1471.02 1747 1481.02 1746 1503.9 1745 1511.17 1743 1518.44 1745 1528.89 1746 1557.56 1747 1577.06 1748 1613.89 1750 Manning's n Values num= 4 Sta n Val Sta n Val Sta n Val Sta n Val 1000 .032 1312.18 .027 1369.41 .032 1557.56 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1312.18 1557.56 214.41 210.28 250.24 .3 .5 Left Levee Station= 1312.18 Elevation= Right Levee Station= 1557.56 Elevation= 4 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * * * * ** * * * * * ** * E.G. Elev (ft) * 1749.05 * Element * Left OB * Channel * Right OB * Vel Head (ft) * 0.72 * Wt. n -Val. * 0.032 * 0.030 * 0.032 * W.S. Elev (ft) * 1748.34 * Reach Len. (ft) * 214.41 * 210.28 * 250.24 * Crit W.S. (ft) * 1748.34 * Flow Area (sq ft) * 13.11 * 398.42 * 17.32 * E.G. Slope (ft /ft) *0.009631 * Area (sq ft) * 13.11 * 398.42 * 17.32 * Q Total (cfs) * 2830.00 * Flow (cfs) * 25.11 * 2744.24 * 60.65 * Top Width (ft) * 319.17 * Top Width (ft) * 48.12 * 245.38 * 25.67 * Vel Total (ft /s) * 6.60 * Avg. Vel. (ft /s) * 1.92 * 6.89 * 3.50 * Max Chl Dpth (ft) * 5.34 * Hydr. Depth (ft) * 0.27 * 1.62 * 0.67 * Conv. Total (cfs) * 28836.9 * Conv. (cfs) * 255.8 * 27963.0 * 618.0 * Length Wtd. (ft) * 210.88 * Wetted Per. (ft) * 48.12 * 247.15 * 25.71 * Min Ch E1 (ft) * 1743.00 * Shear (lb /sq ft) * 0.16 * 0.97 * 0.41 * Alpha * 1.06 * Stream Power (lb /ft s) * 0.31 * 6.68 * 1.42 * Frctn Loss (ft) * 1.96 * Cum Volume (acre -ft) * 23.83 * 24.64 * 18.86 * C & E Loss (ft) * 0.07 * Cum SA (acres) * 19.37 * 8.24 * 23.97 warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 4480 INPUT Description: Station Elevation Data num= 30 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * ** * * * * * * * * * * * * * ** * * * * * * * * * * ** 1000 1744 1160.05 1744 1202.14 1743 1234.97 1743 1275.6 1743 1281.01 1741 1283.98 1740 1286.52 1739 1291.52 1738.2 1299.3 1738.2 1304.3 1739 1313.02 1740 1317.8 1741 1321.94 1742 1340.86 1743 1354.51 1743 1359.96 1742 1365.45 1741 1371.28 1740 1406.24 1739 1418.42 1738 1421.77 1737 1427.74 1737 1427.75 1737 1430.26 1738 1433.85 1739 1443.56 1740 1452.32 1741 1480.76 1741.55 1592.92 1742 Manning's n Values num= 4 Sta n Val Sta n Val Sta n Val Sta n Val 1000 .032 1275.6 .027 1340.86 .032 1480.76 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1275.6 1480.76 225.46 209.85 239.32 .3 .5 Left Levee Station= 1275.6 Elevation= Right Levee Station= 1480.76 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * ** * ** * * * * * * * * * * * * * * * * * * * * * ** • E.G. Elev (ft) * 1742.85 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.94 * Wt. n -Val. * * 0.030 * 0.032 * • W.S. Elev (ft) * 1741.90 * Reach Len. (ft) * 225.46 * 209.85 * 239.32 * • Crit W.S. (ft) * 1741.90 * Flow Area (sq ft) * * 359.29 * 15.54 * • E.G. Slope (ft /ft) *0.008992 * Area (sq ft) * * 359.29 * 15.54 * * Q Total (cfs) * 2830.00 * Flow (cfs) * * 2808.46 * 21.54 * * Top Width (ft) * 251.27 * Top Width (ft) * * 163.24 * 88.03 * * Vel Total (ft /s) * 7.55 * Avg. Vel. (ft /s) * * 7.82 * 1.39 * * Max Chl Dpth (ft) * 4.90 * Hydr. Depth (ft) * * 2.20 * 0.18 * * Conv. Total (cfs) * 29843.5 * Conv. (cfs) * * 29616.3 * 227.2 * * Length Wtd. (ft) * 214.22 * Wetted Per. (ft) * * 164.96 * 88.03 * * Min Ch E1 (ft) * 1737.00 * Shear (lb /sq ft) * * 1.22 * 0.10 * * Alpha * 1.06 * Stream Power (lb /ft s) * * 9.56 * 0.14 * * Frctn Loss (ft) * 1.42 * Cum Volume (acre -ft) * 23.79 * 22.81 * 18.76 * * C & E Loss (ft) * 0.16 * Cum SA (acres) * 19.25 * 7.25 * 23.65 * 5 Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 4280 INPUT Description: Station Elevation Data num= 57 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 1756 1002.82 1755 1010.04 1750 1021.31 1745 1032.35 1740 1034.58 1739 1037.11 1738 1040.92 1737 1046.57 1736 1051.99 1735 1062.44 1734 1075.53 1733 1103.1 1733 1122.86 1734 1141.72 1735 1171.32 1735 1224.56 1735 1315.5 1735 1323.36 1734 1327.43 1733 1331.52 1733 1337.4 1734 1343.28 1735 1400.62 1735 1420.16 1735 1426.85 1735 1441.77 1735 1480.47 1736 1604.81 1736 1609.71 1736 1612.87 1736 1615.96 1736 1633.48 1736 1637.64 1736 1640.36 1736 1642.87 1736 1646.07 1736 1649.88 1735 1652.87 1734 1655.64 1733 1664.54 1732.29 1673.43 1733 1676.73 1733 1685.64 1732.1 1694.54 1733 1698.91 1734 1702.42 1735 1706.16 1736 1733.73 1736 1778.73 1735.1 1781.73 1735.1 1823.74 1736 1834.73 1736 1838.91 1736 1851.18 1736 1860.06 1736 2004.15 1737 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .032 1633.48 .027 1733.73 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1633.48 1733.73 193.46 192.99 195.79 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F CROSS SECTION OUTPUT Profile #EXISTING (B) SUB • E.G. Elev (ft) * 1737.57 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.61 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1736.96 * Reach Len. (ft) * 193.46 * 192.99 * 195.79 * • Crit W.S. (ft) * 1736.96 * Flow Area (sq ft) * 72.03 * 258.69 * 229.65 * • E.G. Slope (ft /ft) *0.005117 * Area (sq ft) * 1127.19 * 258.69 * 229.65 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 232.91 * 1903.29 * 693.80 * * Top Width (ft) * 957.31 * Top Width (ft) * 592.34 * 100.25 * 264.72 * * Vel Total (ft /s) * 5.05 * Avg. Vel. (ft /s) * 3.23 * 7.36 * 3.02 * * Max Chl Dpth (ft) * 4.86 * Hydr. Depth (ft) * 0.96 * 2.58 * 0.87 * * Conv. Total (cfs) * 39562.9 * Conv. (cfs) * 3256.1 * 26607.6 * 9699.1 * * Length Wtd. (ft) * 193.92 * Wetted Per. (ft) * 75.00 * 101.25 * 264.74 * * Min Ch E1 (ft) * 1732.10 * Shear (lb /sq ft) * 0.31 * 0.82 * 0.28 * • Alpha * 1.55 * Stream Power (lb /ft s) * 0.99 * 6.00 * 0.84 * • Frctn Loss (ft) * 0.89 * Cum Volume (acre -ft) * 20.88 * 21.32 * 18.09 * • C & E Loss (ft)' * 0.08 * Cum SA (acres) * 17.72 * 6.62 * 22.68 * warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to no INPUT Description: Station Elevation Data num= 60 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * ** * * * * * * ** * * * * * * * * * * ** * * * * * * ** 1000 1741 1002.65 1740 1013.11 1735 1027.23 1730 1037.21 1729 1049.95 1728 1062.69 1727.6 1090.7 1728 1118.18 1729 1150.59 1730 1160.91 1730 1197.74 1729 1202.25 1729 1268.34 1730 1270.7 1730 1270.74 1730 1274.52 1729 1282.27 1728 1282.28 1728 1289.76 1728 1311.6 1729 1360.37 1730 1488.52 1730 1493.4 1730 1495.63 1730 1498.54 1730 1515.62 1730 1518.64 1730 1521.33 1730 1524.14 1730 1525.22 1730 1525.23 1730 1527.88 1729 1530.47 1728 1533.44 1727 1536.85 1726 1541 1725.7 1545.48 1726 1550.39 1727 1554.47 1728 1556.64 1729 1559.23 1730 1562.15 1730 1565.11 1730 1584.7 1730 1588.53 1730 1592.97 1730 1630.3 1730 1720.08 1731 1752 1731 1794 1730 1808 1730 1869 1730.3 1907.7 1730.3 1975 1731 2010 1731 2022 1730.8 2030.83 1731 2037.12 1731.7 2043.24 1731 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 .032 1515.62 .027 1565.11 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1515.62 1565.11 206.72 211.65 218.14 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F Right Levee Station= 2037.12 Elevation= 1731.7 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * ** * * * * * * * * * * * * * * * * * ** ** • E.G. Elev (ft) * 1731.75 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.45 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1731.30 * Reach Len. (ft) * 206.72 * 211.65 * 218.14 * • Crit W.S. (ft) * 1731.30 * Flow Area (sq ft) * 171.08 * 156.86 * 391.68 * • E.G. Slope (ft /ft) *0.004151 * Area (sq ft) * 952.09 * 156.86 * 391.68 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 610.93 * 1179.13 * 1039.94 * * Top Width (ft) * 1010.02 * Top Width (ft) * 492.07 * 49.49 * 468.45 * * Vel Total (ft /s) * 3.93 * Avg. Vel. (ft /s) * 3.57 * 7.52 * 2.66 * * Max Chl Dpth (ft) * 5.60 * Hydr. Depth (ft) * 1.30 * 3.17 * 0.84 * * Conv. Total (cfs) * 43925.0 * Conv. (cfs) * 9482.4 * 18301.6 * 16141.1 * * Length Wtd. (ft) * 210.99 * Wetted Per. (ft) * 131.19 * 50.81 * 468.50 * * Min Ch El (ft) * 1725.70 * Shear (lb /sq ft) * 0.34 * 0.80 * 0.22 * * Alpha * 1.87 * Stream Power (lb /ft s) * 1.21 * 6.01 * 0.58 * * Frctn Loss (ft) * 1.75 * Cum Volume (acre -ft) * 16.26 * 20.40 * 16.69 * * C & E Loss (ft) * 0.59 * Cum SA (acres) * 15.31 * 6.29 * 21.03 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. 7 indicates critical depth, the calculated water surface came back below critical depth. This k ov that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 4080 INPUT Description: Station Elevation Data num= 60 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * ** * * * * * * ** * * * * * * * * * * ** * * * * * * ** 1000 1741 1002.65 1740 1013.11 1735 1027.23 1730 1037.21 1729 1049.95 1728 1062.69 1727.6 1090.7 1728 1118.18 1729 1150.59 1730 1160.91 1730 1197.74 1729 1202.25 1729 1268.34 1730 1270.7 1730 1270.74 1730 1274.52 1729 1282.27 1728 1282.28 1728 1289.76 1728 1311.6 1729 1360.37 1730 1488.52 1730 1493.4 1730 1495.63 1730 1498.54 1730 1515.62 1730 1518.64 1730 1521.33 1730 1524.14 1730 1525.22 1730 1525.23 1730 1527.88 1729 1530.47 1728 1533.44 1727 1536.85 1726 1541 1725.7 1545.48 1726 1550.39 1727 1554.47 1728 1556.64 1729 1559.23 1730 1562.15 1730 1565.11 1730 1584.7 1730 1588.53 1730 1592.97 1730 1630.3 1730 1720.08 1731 1752 1731 1794 1730 1808 1730 1869 1730.3 1907.7 1730.3 1975 1731 2010 1731 2022 1730.8 2030.83 1731 2037.12 1731.7 2043.24 1731 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 .032 1515.62 .027 1565.11 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1515.62 1565.11 206.72 211.65 218.14 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F Right Levee Station= 2037.12 Elevation= 1731.7 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * ** * * * * * * * * * * * * * * * * * ** ** • E.G. Elev (ft) * 1731.75 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.45 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1731.30 * Reach Len. (ft) * 206.72 * 211.65 * 218.14 * • Crit W.S. (ft) * 1731.30 * Flow Area (sq ft) * 171.08 * 156.86 * 391.68 * • E.G. Slope (ft /ft) *0.004151 * Area (sq ft) * 952.09 * 156.86 * 391.68 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 610.93 * 1179.13 * 1039.94 * * Top Width (ft) * 1010.02 * Top Width (ft) * 492.07 * 49.49 * 468.45 * * Vel Total (ft /s) * 3.93 * Avg. Vel. (ft /s) * 3.57 * 7.52 * 2.66 * * Max Chl Dpth (ft) * 5.60 * Hydr. Depth (ft) * 1.30 * 3.17 * 0.84 * * Conv. Total (cfs) * 43925.0 * Conv. (cfs) * 9482.4 * 18301.6 * 16141.1 * * Length Wtd. (ft) * 210.99 * Wetted Per. (ft) * 131.19 * 50.81 * 468.50 * * Min Ch El (ft) * 1725.70 * Shear (lb /sq ft) * 0.34 * 0.80 * 0.22 * * Alpha * 1.87 * Stream Power (lb /ft s) * 1.21 * 6.01 * 0.58 * * Frctn Loss (ft) * 1.75 * Cum Volume (acre -ft) * 16.26 * 20.40 * 16.69 * * C & E Loss (ft) * 0.59 * Cum SA (acres) * 15.31 * 6.29 * 21.03 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. 7 Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3880 INPUT Description: Station Elevation Data num= 44 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* ** * * * * ** * * ** * * * ** * * * * * * * * * * * * ** 1006.95 1727 1012.02 1726 1015.17 1725 1018.77 1724 1022.46 1723 1025.15 1722 1049.31 1722 1052.22 1722 1111.08 1721.01 1121.64 1721.01 1174.81 1722 1241.8 1723 1285.63 1724 1322.09 1724 1327.78 1724 1331.13 1724 1340.11 1724 1347.19 1724 1349.15 1724 1351.46 1724 1355.2 1724 1357.3 1724 1360.45 1723 1362.37 1722 1365.71 1721 1368 1720.15 1378 1720.15 1381.72 1721 1384.57 1722 1387.28 1723 1389.68 1724 1391.72 1725 1394.04 1726 1397.23 1726 1409.23 1726 1412.46 1726 1415.71 1726 1418.83 1726 1418.84 1726 1520.65 1726 1527.31 1727 1530.9 1727 1536.13 1726 1539.66 1725 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1006.95 .032 1355.2 .027 1394.04 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1355.2 1394.04 69.26 71.01 74.36 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F CROSS SECTION OUTPUT Profile #EXISTING (B) SUB • E.G. Elev (ft) * 1726.39 * Element * Left OB * Channel * Right OB • Vel Head (ft) * 2.41 * Wt. n -Val. * 0.032 * 0.027 * • W.S. Elev (ft) * 1723.99 * Reach Len. (ft) * 69.26 * 71.01 * 74.36 • Crit W.S. (ft) * 1723.99 * Flow Area (sq ft) * 175.56 * 83.81 * • E.G. Slope (ft /ft) *0.024196 * Area (sq ft) * 489.67 * 83.81 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 1511.34 * 1318.66 * * Top Width (ft) * 298.48 * Top Width (ft) * 266.18 * 32.30 * * Vel Total (ft /s) * 10.91 * Avg. Vel. (ft /s) * 8.61 * 15.73 * * Max Chl Dpth (ft) * 3.84 * Hydr. Depth (ft) * 1.30 * 2.59 * * Conv. Total (cfs) * 18193.3 * Conv. (cfs) * 9716.0 * 8477.3 * * Length Wtd. (ft) * 69.74 * Wetted Per. (ft) * 134.92 * 33.64 * • Min Ch E1 (ft) * 1720.15 * Shear (lb /sq ft) * 1.97 * 3.76 * • Alpha * 1.30 * Stream Power (lb /ft s) * 16.92 * 59.22 * • Frctn Loss (ft) * 0.10 * Cum Volume (acre -ft) * 12.84 * 19.81 * 15.71 • C & E Loss (ft) * 0.03 * Cum SA (acres) * 13.51 * 6.09 * 19.86 **************************************************************** * * * * * * * * * * ** * * * * * * * * * * * * * * * * * ** Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3810 INPUT c;. Description: Station Elevation Data num= 31 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 1728 1019.46 1727 1033.92 1726 1038.96 1725 1044.14 1724 1050.93 1723 1055.59 1722 1120.54 1721.01 1146.45 1720 1158.71 1720 1227.31 1721.01 1286.37 1722 1302.47 1722 1332.05 1722 1335 1723 1337.36 1723 1341 1723 1357.19 1723 1359.26 1723 1360.47 1723 1362.53 1722 1364.54 1721 1367.12 1720 1371.62 1718.1 1383.3 1718.15 1387.6 1720 1391.18 1721 1393.22 1722 1395.99 1723 1406.23 1724 1437.81 1725 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 .032 1359.26 .032 1406.23 .027 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1359.26 1406.23 39.27 41.65 37.64 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • E.G. Elev (ft) * 1723.90 * Element * Left OB * Channel * Right OB • Vel Head (ft) * 0.30 * Wt. n -Val. * 0.032 * 0.032 * • W.S. Elev (ft) * 1723.60 * Reach Len. (ft) * 39.27 * 41.65 * 37.64 • Crit W.S. (ft) * 1722.69 * Flow Area (sq ft) * 508.99 * 139.22 * • E.G. Slope (ft /ft) *0.002691 * Area (sq ft) * 692.65 * 139.22 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 2116.20 * 713.80 * * Top Width (ft) * 355.22 * Top Width (ft) * 312.38 * 42.84 * * Vel Total (ft /s) * 4.37 * Avg. Vel. (ft /s) * 4.16 * 5.13 * * Max Chl Dpth (ft) * 5.50 * Hydr. Depth (ft) * 2.27 * 3.25 * * Conv. Total (cfs) * 54556.7 * Conv. (cfs) * 40796.1 * 13760.6 * * Length Wtd. (ft) * 41.65 * Wetted Per. (ft) * 224.45 * 44.83 * * Min Ch E1 (ft) * 1718.10 * Shear (lb /sq ft) * 0.38 * 0.52 * * Alpha * 1.03 * Stream Power (lb /ft s) * 1.58 * 2.67 * * Frctn Loss (ft) * * Cum Volume (acre -ft) * 11.90 * 19.63 * 15.71 * C & E Loss (ft) * * Cum SA (acres) * 13.05 * 6.03 * 19.86 **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CULVERT RIVER: Reach #1 REACH: Reach #1 RS: 3790 INPUT Description: Distance from Upstream XS = 2.5 Deck /Roadway Width = 32 weir Coefficient = 2.6 Upstream Deck /Roadway Coordinates num= 5 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1360.47 1723 1367.12 1722 1371.62 1722 1383.3 1722 1395.99 1723 Upstream Bridge Cross Section Data Station Elevation Data Sta Elev Sta * * * * * * * * * * * * * * * * * * * * * * ** 1000 1728 1019.46 1050.93 1723 1055.59 1227.31 1721.01 1286.37 1337.36 1723 1341 1362.53 1722 1364.54 1387.6 1720 1391.18 1437.81 1725 num= 31 Elev Sta Elev Sta 1727 1033.92 1726 1038.96 1722 1120.54 1721.01 1146.45 1722 1302.47 1722 1332.05 1723 1357.19 1723 1359.26 1721 1367.12 1720 1371.62 1721 1393.22 1722 1395.99 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 .032 1359.26 .032 1406.23 .027 Elev Sta Elev 1725 1044.14 1724 1720 1158.71 1720 1722 1335 1723 1723 1360.47 1723 1718.1 1383.3 1718.15 1723 1406.23 1724 E N M A Bank Sta: Left Right 1359.26 1406.23 Ineffective Flow num= Sta L Sta R Elev 888 F Coeff Contr. Expan. .3 .5 1 Permanent Downstream Deck /Roadway Coordinates num= 5 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord 1321.44 1722 1331.99 1722 1346.7 1722 1355.3 1722 1367.71 1722 Downstream Bridge Cross Section Data Station Elevation Data num= 30 Culvert ID : CULVERT #1 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev * Culy Q (cfs) * 1000 1725 1018.15 1724 1037.28 1723 1057.78 1722 1078.18 1721.01 1097.82 1720 1116.87 1719 1118.3 1719 1190.9 1720 1226.6 1721.01 1296.52 1722 1300.78 1722 1321.44 1722 1331.99 1722 1337.53 1719 1339.35 1718 1340.8 1717.23 1353.9 1717.23 1355.3 1718 1356.56 1719 1356.57 1719 1358.77 1720 1364.21 1722 1367.71 1722 1392.29 1722 1402.24 1722 1403.66 1722 1405.06 1722 1422.25 1722 1445.57 1722 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 .035 1331.99 .027 1367.71 .035 Bank Sta: Left Right Coeff Contr. Expan. 1331.99 1367.71 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F Right Levee Station= 1445.57 Elevation= 1725 Upstream Embankment side slope = 2 horiz. to 1.0 vertical Downstream Embankment side slope = 2 horiz. to 1.0 vertical Maximum allowable submergence for weir flow = .95 Elevation at which weir flow begins = 1722.02 Energy head used in spillway design = Spillway height used in design = Weir crest shape = Broad Crested Number of Culverts = 1 Culvert Name Shape Rise Span CULVERT #1 Circular 3 FHWA Chart # 1 - Concrete Pipe Culvert FHWA Scale # 2 - Groove end entrance with headwall Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value Entrance Loss Coef Exit Loss Coef 2.5 32 .024 .5 1 Number of Barrels = 3 Upstream Elevation = 1717.5 Centerline Stations Sta. Sta. Sta. 1370.96 1377.46 1383.96 Downstream Elevation = 1716.5 Centerline Stations Sta. Sta. Sta. 1340.85 1347.35 1353.85 CULVERT OUTPUT Profile #EXISTING (B) SUB Culvert ID : CULVERT #1 * Culy Q (cfs) * 146.18 * Culy Ful Lngh (ft) * 32.00 * * # Barrels * 3 * Culy Vel US (ft /s) * 6.89 * * Q Barrel (cfs) * 48.73 * Culy Vel DS (ft /s) * 6.89 * * E.G. US. (ft) * 1723.90 * Culy Inv E1 Up (ft) * 1717.50 * * W.S. US. (ft) * 1723.60 * Culy Inv E1 Dn (ft) * 1716.50 * * E.G. DS (ft) * 1722.89 * Culy Frctn Ls (ft) * 0.58 * 10 CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3770 INPUT Description: Station Elevation Data * W.S. DS * Delta EG (ft) (ft) * Element * * 1722.21 1.01 * Culy Ext Lss (ft) * Culy Ent Lss (ft) * 0.06 * * 0.37 * Elev Sta * Delta WS (ft) Elev * 1.38 * Q Weir (cfs) * 2683.82 * + + + + + + + + + * E.G. IC (ft) 1000 1725 1018.15 * 1723.82 * Weir Sta Lft (ft) * 1135.00 * 1078.18 * E.G. OC (ft) 1719 1118.3 * 1723.90 * Weir Sta Rgt (ft) * 1404.96 * 1721.01 * Culvert Control * Outlet * Weir Submerg * 0.38 * 1719 * Culy WS Inlet (ft) * 1720.50 * Weir Max Depth (ft) * 3.88 * 1356.57 1719 1358.77 * Culy WS Outlet (ft) * 1719.50 * Weir Avg Depth (ft) * 2.35 * 1722 1405.06 * Culy Nml Depth (ft) * 1722 * Wr Flw Area (sq ft) * 633.65 * * Conv. Total (cfs) * Culy Crt Depth (ft) * 2.27 * Min E1 Weir Flow (ft) * 1722.02 * * ++++++++++++++++++++++++++++++++++++++++ * Wetted Per. (ft) * 240.05 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3770 INPUT Description: Station Elevation Data num= 30 1722.89 * Element * Left OB * Channel * Right OB * Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ++++++*++++++++++++++++++++++++++++++++++++++++++ * + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ 1000 1725 1018.15 1724 1037.28 1723 1057.78 1722 1078.18 1721.01 1097.82 1720 1116.87 1719 1118.3 1719 1190.9 1720 1226.6 1721.01 1296.52 1722 1300.78 1722 1321.44 1722 1331.99 1722 1337.53 1719 1339.35 1718 1340.8 1717.23 1353.9 1717.23 1355.3 1718 1356.56 1719 1356.57 1719 1358.77 1720 1364.21 1722 1367.71 1722 1392.29 1722 1402.24 1722 1403.66 1722 1405.06 1722 1422.25 1722 1445.57 1722 Manning's n Values num= 3 * Conv. Total (cfs) * 35228.7 * Conv. (cfs) * 22204.0 Sta n Val Sta n Val Sta n Val * 100.95 * Wetted Per. (ft) * 240.05 +++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ * 1717.23 * Shear (lb /sq ft) * 0.64 1000 .035 1331.99 .027 1367.71 .035 * 1.43 * Stream Power (lb /ft s) * 2.99 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1331.99 1367.71 102.56 99.18 101.15 0.01 .3 .5 Ineffective Flow num= 1 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Sta L Sta R Elev Permanent 888 F Right Levee Station= 1445.57 Elevation= 1725 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ • E.G. Elev (ft) * 1722.89 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.68 * Wt. n -Val. * 0.035 * 0.027 * 0.035 * • W.S. Elev (ft) * 1722.21 * Reach Len. (ft) * 102.56 * 99.18 * 101.15 * • Crit W.S. (ft) * 1722.21 * Flow Area (sq ft) * 383.02 * 112.61 * 16.50 * • E.G. Slope (ft /ft) *0.006453 * Area (sq ft) * 419.43 * 112.61 * 16.50 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 1783.69 * 1026.34 * 19.97 * * Top Width (ft) * 392.13 * Top Width (ft) * 278.55 * 35.72 * 77.86 * * Vel Total- (ft /s) * 5.53 * Avg. Vel. (ft /s) * 4.66 * 9.11 * 1.21 * * Max Chl Dpth (ft) * 4.98 * Hydr. Depth (ft) * 1.60 * 3.15 * 0.21 * * Conv. Total (cfs) * 35228.7 * Conv. (cfs) * 22204.0 * 12776.2 * 248.5 * * Length Wtd. (ft) * 100.95 * Wetted Per. (ft) * 240.05 * 38.05 * 78.07 * * Min Ch E1 (ft) * 1717.23 * Shear (lb /sq ft) * 0.64 * 1.19 * 0.09 * • Alpha * 1.43 * Stream Power (lb /ft s) * 2.99 * 10.87 * 0.10 * • Frctn Loss (ft) * 0.58 * Cum Volume (acre -ft) * 11.40 * 19.51 * 15.70 * • C & E Loss (ft) * 0.01 * Cum SA (acres) * 12.79 * 5.99 * 19.82 * ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The cross - section end points had to be extended vertically for the computed water surface. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, energy was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3665 11 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 964.33 .032 1204.18 .027 1252.19 .032 Bank Sta: Left Right INPUT Lengths: Left Channel Right Coeff Contr. Expan. 1204.18 1252.19 267.49 249.65 249.26 Sta .3 Description: Elev CROSS SECTION OUTPUT Profile #EXISTING (B) SUB Elev • E.G. Elev (ft) * 1719.18 * Element * Station Elevation Data num= 39 0.73 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev * 249.26 * 964.33 1719 982 1718 994.01 1717 1003.98 1716 1012.7 1716 1264 1075.33 1717.01 1100.83 1718 1125.99 1718 1133.58 1718 1161.32 1719 846.40 1173.42 1719 1177.59 1719 1177.96 1719 1204.18 1719 1206.29 1719 * Vel Total (ft /s) 1207.13 1718 1208.96 1717 1210.41 1716 1211.26 1715 1216.23 1714 * Hydr. Depth (ft) 1219 1713.1 1229 1713.1 1232.87 1714 1238.1 1715 1241.9 1716 * 19888.1 1243.34 1717 1245.14 1717 1248.27 1717 1252.19 1717 1278.59 1717 * 1280.72 1717 1282.41 1717 1288.22 1717 1296.12 1717 1298.32 1717 * 1300.52 1717 1341.89 1717 1352.21 1718 1377.83 1719.5 10.65 * 19.20 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 964.33 .032 1204.18 .027 1252.19 .032 Bank Sta: Left Right Elevation Lengths: Left Channel Right Coeff Contr. Expan. 1204.18 1252.19 267.49 249.65 249.26 Sta .3 .5 Elev CROSS SECTION OUTPUT Profile #EXISTING (B) SUB Elev • E.G. Elev (ft) * 1719.18 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.73 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1718.46 * Reach Len. (ft) * 267.49 * 249.65 * 249.26 * • Crit W.S. (ft) * 1718.46 * Flow Area (sq ft) * 218.40 * 160.58 * 142.19 * • E.G. Slope (ft /ft) *0.005082 1264 * Area (sq ft) * 218.40 * 160.58 * 142.19 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 846.40 * 1417.75 * 565.85 * * Top Width (ft) * 325.50 * Top Width (ft) * 172.26 * 45.44 * 107.80 * * Vel Total (ft /s) * 5.43 * Avg. Vel. (ft /s) * 3.88 * 8.83 * 3.98 * * Max Chl Dpth (ft) * 5.36 * Hydr. Depth (ft) * 1.27 * 3.53 * 1.32 * * Conv. Total (cfs) * 39699.1 * Conv. (cfs) * 11873.3 * 19888.1 * 7937.7 * * Length Wtd. (ft) * 254.89 * Wetted Per. (ft) * 172.40 * 47.57 * 107.86 * * Min Ch E1 (ft) * 1713.10 * Shear (lb /sq ft) * 0.40 * 1.07 * 0.42 * * Alpha * 1.58 * Stream Power (lb /ft s) * 1.56 * 9.46 * 1.66 * * Frctn Loss (ft) * 1.24 * Cum Volume (acre -ft) * 10.65 * 19.20 * 15.52 * * C & E Loss (ft) * 0.04 * Cum SA (acres) * 12.25 * 5.90 * 19.61 * **************************************************************** ** * * * * * *** * * * * * * * * * * * * * * * * * * * ** Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3400 INPUT Description: Station Elevation Data num= 32 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 799.93 1712 852.77 1711 907.62 1711 945.17 1711 1150.86 1711 1173.66 1710.01 1182.18 1708.98 1188.84 1708 1198.26 1708.98 1228.31 1708.98 1231.77 1708.98 1232.82 1709 1240.81 1709 1247.6 1709 1264 1709 1269.72 1709 1277.91 1707 1286.1 1706 1306 1706 1308.96 1707 1315.84 1710.01 1317.75 1711 1320.67 1711 1334.87 1711 1351.39 1711 1365.67 1711 1385.75 1711 1391.47 1711 1411.3 1711 1444.53 1710 1510.75 1710 1702.25 1713 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 799.93 .032 1264 .027 1320.67 .032 12 Bank Sta: Left Right 1264 1320.67 Ineffective Flow num= Sta L Sta R Elev 888 F Lengths: Left Channel Right Coeff Contr. Expan. 198.74 202.99 201.58 .3 .5 1 Permanent CROSS SECTION OUTPUT Profile #EXISTING (B) SUB xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx • E.G. Elev (ft) * 1711.76 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.85 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1710.91 * Reach Len. (ft) * 198.74 * 202.99 * 201.58 * • Crit W.S. (ft) * 1710.91 * Flow Area (sq ft) * 186.37 * 198.88 * 100.21 * • E.G. Slope (ft /ft) *0.004646 * Area (sq ft) * 186.37 * 198.88 * 100.21 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 832.15 * 1760.10 * 237.75 * * Top Width (ft) * 319.00 * Top Width (ft) * 111.03 * 53.57 * 154.40 * * Vel Total (ft /s) * 5.83 * Avg. Vel. (ft /s) * 4.47 * 8.85 * 2.37 * * Max Chl Dpth (ft) * 4.91 * Hydr. Depth (ft) * 1.68 * 3.71 * 0.65 * * Conv. Total (cfs) * 41516.9 * Conv. (cfs) * 12207.8 * 25821.2 * 3487.9 * * Length Wtd. (ft) * 201.46 * Wetted Per. (ft) * 111.24 * 54.89 * 154.42 * * Min Ch E1 (ft) * 1706.00 * Shear (lb /sq ft) * 0.49 * 1.05 * 0.19 * • Alpha * 1.62 * Stream Power (lb /ft s) * 2.17 * 9.30 * 0.45 * • Frctn Loss (ft) * 0.76 * Cum Volume (acre -ft) * 9.40 * 18.17 * 14.83 * • C & E Loss (ft) * 0.15 * Cum SA (acres) * 11.38 * 5.61 * 18.86 * xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. AMIN Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3200 INPUT Description: Station Elevation Data num= 39 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 580 1706 658.38 1705.5 772.5 1706 842.53 1705 888.22 1704 966.51 1705 1000 1705 1012.75 1705 1019.13 1703.99 1028 1703 1036.88 1703.99 1050.59 1704.4 1064.31 1703.99 1069.38 1703.99 1108.39 1703.99 1110.84 1703 1115.26 1702 1118.91 1701.03 1125.81 1699.99 1134.1 1699.99 1143.79 1701.03 1148.11 1702 1150.41 1703 1151.92 1703.99 1153.75 1705 1155.43 1705 1158.42 1705 1180.77 1705 1185.59 1705 1189.92 1705 1192.11 1705 1218.47 1705 1224.01 1703.99 1232.86 1703.99 1239.31 1704.99 1247.35 1704.99 1249.51 1704.99 1258.43 1704.99 1472.84 1708 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 580 .032 1108.39 .027 1158.42 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1108.39 1158.42 73.09 74.68 76.3 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F Left Levee Station= 1108.39 Elevation= 1703.99 Right Levee Station= 1158.42 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB xxxxxx*xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx xx xxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx • E.G. Elev (ft) * 1706.27 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.55 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1705.72 * Reach Len. (ft) * 73.09 * 74.68 * 76.30 * 13 Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3130 INPUT Description: Station Elevation Data num= 41 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 740 1705 1000 1703.99 1041.97 1703 1144.45 1703 1219.94 1703 1227.87 1702 1238.18 1702 1276.09 1703 1282.89 1703.99 1311.12 1703.99 1312.87 1703 1315.37 1702 1316.87 1701.03 1319.74 1699.99 1325.07 1699 1326.7 1697.99 1333.9 1697.7 1340.33 1697.99 1345.54 1699 1347.15 1699.99 1350.98 1701.03 1353.22 1702 1355.44 1703 1391.04 1703 1405.6 1702 1405.61 1702 1417.72 1702 1428.38 1703 1437.9 1703.99 1442.21 1703.99 1455.66 1703.99 1458.96 1703.99 1479.67 1703 1482.96 1701.99 1494.32 1701.99 1496.76 1703 1549.34 1703 1578.2 1703 1578.3 1703 1641.89 1703.98 1716.2 1705 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 740 .032 1311.12 .027 1355.44 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1311.12 1355.44 43.68 40.91 42.27 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F CROSS SECTION OUTPUT Profile #EXISTING (B) SUB • E.G. Elev (ft) * 1704.50 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.53 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1703.97 * Reach Len. (ft) * 43.68 * 40.91 * 42.27 * • Crit W.S. (ft) * 1703.97 * Flow Area (sq ft) * 283.63 * 192.14 * 250.53 * • E.G. Slope MAO *0.002976 * Area (sq ft) * 283.63 * 192.14 * 250.53 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 721.13 * 1484.96 * 623.92 * * Top Width (ft) * 590.39 * Top Width (ft) * 281.93 * 44.29 * 264.18 * * Vel Total (ft /s) * 3.90 * Avg. Vel. (ft /s) * 2.54 * 7.73 * 2.49 * * Max Chl Dpth (ft) * 6.27 * Hydr. Depth (ft) * 1.01 * 4.34 * 0.95 * * Conv. Total (cfs) * 51874.8 * Conv. (cfs) * 13218.5 * 27219.7 * 11436.6 * * Length Wtd. (ft) * 40.91 * Wetted Per. (ft) * 282.09 * 46.53 * 264.69 * * Min Ch El (ft) * 1697.70 * Shear (lb /sq ft) * 0.19 * 0.77 * 0.18 * * Alpha * 2.26 * Stream Power (lb /ft s) * 0.47 * 5.93 * 0.44 * * Frctn Loss (ft) * * Cum Volume (acre -ft) * 7.57 * 16.89 * 14.04 * * C & E Loss (ft) * * Cum SA (acres) * 9.65 * 5.29 * 17.79 * 14 * Crit W.S. (ft) * E.G. Slope (ft /ft) * *0.003098 1705.72 * Flow Area (sq ft) * Area (sq ft) * 367.37 * 376.62 * * 203.40 203.40 * * 105.90 * 105.90 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 1057.39 * 1557.53 * 215.08 * * Top Width (ft) * 601.98 * Top Width (ft) * 400.08 * 50.03 * 151.87 * * Vel Total (ft /s) * 4.18 * Avg. Vel. (ft /s) * 2.88 * 7.66 * 2.03 * * Max Chl Dpth (ft) * 5.73 * Hydr. Depth (ft) * 1.18 * 4.07 * 0.70 * * Conv. Total (cfs) * 50843.3 * Conv. (cfs) * 18996.9 * 27982.3 * 3864.1 * * Length Wtd. (ft) * 74.42 * Wetted Per. (ft) * 312.61 * 51.47 * 152.04 * * Min Ch E1 (ft) * 1699.99 * Shear (lb /sq ft) * 0.23 * 0.76 * 0.13 * • Alpha * 2.04 * Stream Power (lb /ft s) * 0.65 * 5.85 * 0.27 * • Frctn Loss (ft) * 0.23 * Cum Volume (acre -ft) * 8.12 * 17.23 * 14.35 * • C & E Loss (ft) * 0.01 * Cum SA (acres) * 10.22 * 5.37 * 18.15 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3130 INPUT Description: Station Elevation Data num= 41 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 740 1705 1000 1703.99 1041.97 1703 1144.45 1703 1219.94 1703 1227.87 1702 1238.18 1702 1276.09 1703 1282.89 1703.99 1311.12 1703.99 1312.87 1703 1315.37 1702 1316.87 1701.03 1319.74 1699.99 1325.07 1699 1326.7 1697.99 1333.9 1697.7 1340.33 1697.99 1345.54 1699 1347.15 1699.99 1350.98 1701.03 1353.22 1702 1355.44 1703 1391.04 1703 1405.6 1702 1405.61 1702 1417.72 1702 1428.38 1703 1437.9 1703.99 1442.21 1703.99 1455.66 1703.99 1458.96 1703.99 1479.67 1703 1482.96 1701.99 1494.32 1701.99 1496.76 1703 1549.34 1703 1578.2 1703 1578.3 1703 1641.89 1703.98 1716.2 1705 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 740 .032 1311.12 .027 1355.44 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1311.12 1355.44 43.68 40.91 42.27 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F CROSS SECTION OUTPUT Profile #EXISTING (B) SUB • E.G. Elev (ft) * 1704.50 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.53 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1703.97 * Reach Len. (ft) * 43.68 * 40.91 * 42.27 * • Crit W.S. (ft) * 1703.97 * Flow Area (sq ft) * 283.63 * 192.14 * 250.53 * • E.G. Slope MAO *0.002976 * Area (sq ft) * 283.63 * 192.14 * 250.53 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 721.13 * 1484.96 * 623.92 * * Top Width (ft) * 590.39 * Top Width (ft) * 281.93 * 44.29 * 264.18 * * Vel Total (ft /s) * 3.90 * Avg. Vel. (ft /s) * 2.54 * 7.73 * 2.49 * * Max Chl Dpth (ft) * 6.27 * Hydr. Depth (ft) * 1.01 * 4.34 * 0.95 * * Conv. Total (cfs) * 51874.8 * Conv. (cfs) * 13218.5 * 27219.7 * 11436.6 * * Length Wtd. (ft) * 40.91 * Wetted Per. (ft) * 282.09 * 46.53 * 264.69 * * Min Ch El (ft) * 1697.70 * Shear (lb /sq ft) * 0.19 * 0.77 * 0.18 * * Alpha * 2.26 * Stream Power (lb /ft s) * 0.47 * 5.93 * 0.44 * * Frctn Loss (ft) * * Cum Volume (acre -ft) * 7.57 * 16.89 * 14.04 * * C & E Loss (ft) * * Cum SA (acres) * 9.65 * 5.29 * 17.79 * 14 15 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Warning: During analysis, the water surface culvert went to critical depth. subcritical upstream of CULVERT RIVER: Reach #1 REACH: Reach #1 RS: 3110 INPUT Description: Distance from Upstream XS = 2.6 Deck /Roadway Width = 38 Weir Coefficient = 2.6 Upstream Deck /Roadway Coordinates num= 4 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Sta Hi Cord Lo Cord 1312.87 1703 1315.37 1702 1333.9 1701.4 1353.22 1702 Upstream Bridge Cross Section Data Station Elevation Data num= 41 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 740 1705 1000 1703.99 1041.97 1703 1144.45 1703 1219.94 1703 1227.87 1702 1238.18 1702 1276.09 1703 1282.89 1703.99 1311.12 1703.99 1312.87 1703 1315.37 1702 1316.87 1701.03 1319.74 1699.99 1325.07 1699 1326.7 1697.99 1333.9 1697.7 1340.33 1697.99 1345.54 1699 1347.15 1699.99 1350.98 1701.03 1353.22 1702 1355.44 1703 1391.04 1703 1405.6 1702 1405.61 1702 1417.72 1702 1428.38 1703 1437.9 1703.99 1442.21 1703.99 1455.66 1703.99 1458.96 1703.99 1479.67 1703 1482.96 1701.99 1494.32 1701.99 1496.76 1703 1549.34 1703 1578.2 1703 1578.3 1703 1641.89 1703.98 1716.2 1705 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val xxxxxx xxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 740 .032 1311.12 .027 1355.44 .032 Bank Sta: Left Right Coeff Contr. Expan. 1311.12 1355.44 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F Downstream Deck /Roadway Coordinates num= 5 Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord Sta Hi Cord Lo Cord xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 1639.91 1702 1652.74 1701 1662.06 1700.5 1672.74 1701 1681.92 1702 Downstream Bridge Cross Section Data Station Elevation Data num= 43 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 1000 1703.99 1273.58 1703 1348.33 1702 1391.76 1701 1403.27 1701 1491.23 1702 1525.21 1702 1544.81 1702 1549.4 1702 1558.87 1701 1564.57 1701 1603.23 1702 1639.91 1702 1642.74 1701 1645.09 1699.99 1647.75 1699 1650.51 1698 1655.28 1697 1662.06 1696.6 1668.84 1697 1671.09 1698 1671.1 1698 1673.29 1699 1675.69 1699.99 1678.38 1701.03 1681.92 1702 1689.34 1703 1703.43 1703 1721.56 1702 1750.45 1702 1764.19 1703 1768.33 1703 1812.87 1702 1824.16 1701 1833.5 1700 1833.51 1700 1837.57 1700 1840.26 1701 1842.78 1702 1857.35 1702 1894.08 1702 1958.79 1703 2060.76 1704 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 1000 .032 1639.91 .027 1689.34 .032 Bank Sta: Left Right Coeff Contr. Expan. 1639.91 1689.34 .3 .5 Ineffective Flow num= 1 15 Culvert Name Shape Rise Span CULVERT #1 Circular 3 FHWA Chart # 2 - Corrugated Metal Pipe Culvert FHWA Scale # 1 - Headwall Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value Entrance Loss Coef Exit Loss Coef 2.6 38 .024 .5 1 Number of Barrels = 3 Upstream Elevation = 1697.2 Centerline Stations Sta. Sta. Sta. 1329.4 1333.9 1338.4 Downstream Elevation = 1696.2 Centerline Stations Sta. Sta. Sta. 1657.56 1662.06 1666.56 CULVERT OUTPUT Profile #EXISTING (B) SUB Culvert ID : CULVERT #1 * Culy Q (cfs) * 131.88 * Culy Ful Lngh (ft) * 38.00 * * # Barrels * 3 * Culy Vel US (ft /s) * 6.22 * * Q Barrel (cfs) * 43.96 * Culy Vel DS (ft /s) * 6.22 * * E.G. US. (ft) * 1704.31 * Culy Inv E1 Up (ft) * 1697.20 * * W.S. US. (ft) * 1703.97 * Culy Inv E1 Dn (ft) * 1696.20 * * E.G. DS (ft) * 1703.32 * Culy Frctn Ls (ft) * 0.56 * * W.S. DS (ft) * 1702.85 * Culy Ext Lss (ft) * 0.13 * * Delta EG (ft) * 0.99 * Culy Ent Lss (ft) * 0.30 * * Delta WS (ft) * 1.12 * Q Weir (cfs) * 2698.12 * * E.G. IC (ft) * 1704.27 * Weir Sta Lft (ft) * 976.00 * * E.G. OC (ft) * 1704.31 * Weir Sta Rgt (ft) * 1665.78 * * Culvert Control * Outlet * Weir Submerg * 0.15 * * Culy WS Inlet (ft) * 1700.20 * Weir Max Depth (ft) * 2.91 * * Culy WS Outlet (ft) * 1699.20 * Weir Avg Depth (ft) * 1.24 * * Culy Nml Depth (ft) * * Wr Flw Area (sq ft) * 853.89 * * Culy Crt Depth (ft) * 2.16 * Min E1 Weir Flow (ft) * 1701.41 * **************************************** * ** ** * * * * * * * * * * * * * * * * * * * * * * * * ** Warning: During subcritical analysis, the water surface upstream of culvert went to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3090 INPUT Description: Station Elevation Data Sta Elev Sta 1000 1703.99 1273.58 1491.23 1702 1525.21 1564.57 1701 1603.23 1647.75 1699 1650.51 1671.09 1698 1671.1 1681.92 1702 1689.34 1764.19 1703 1768.33 1833.51 1700 1837.57 1894.08 1702 1958.79 Manning's n Values Sta n Val Sta num= 43 Elev Sta 1703 1348.33 1702 1544.81 1702 1639.91 1698 1655.28 1698 1673.29 1703 1703.43 1703 1812.87 1700 1840.26 1703 2060.76 num= 3 n Val Sta Elev Sta Elev Sta Elev 1702 1391.76 1701 1403.27 1701 1702 1549.4 1702 1558.87 1701 1702 1642.74 1701 1645.09 1699.99 1697 1662.06 1696.6 1668.84 1697 1699 1675.69 1699.99 1678.38 1701.03 1703 1721.56 1702 1750.45 1702 1702 1824.16 1701 1833.5 1700 1701 1842.78 1702 1857.35 1702 1704 n Val 16 888 Sta L F Sta R Elev Permanent Upstream Embankment side slope = 2 horiz. to 1.0 vertical Downstream Embankment side slope = 2 horiz. to 1.0 vertical Maximum allowable submergence for weir flow = .95 Elevation at which weir flow begins = 1701.4 Energy head used in spillway design = Spillway height used in design = Weir crest shape = Broad Crested Number of Culverts = 1 Culvert Name Shape Rise Span CULVERT #1 Circular 3 FHWA Chart # 2 - Corrugated Metal Pipe Culvert FHWA Scale # 1 - Headwall Solution Criteria = Highest U.S. EG Culvert Upstrm Dist Length n Value Entrance Loss Coef Exit Loss Coef 2.6 38 .024 .5 1 Number of Barrels = 3 Upstream Elevation = 1697.2 Centerline Stations Sta. Sta. Sta. 1329.4 1333.9 1338.4 Downstream Elevation = 1696.2 Centerline Stations Sta. Sta. Sta. 1657.56 1662.06 1666.56 CULVERT OUTPUT Profile #EXISTING (B) SUB Culvert ID : CULVERT #1 * Culy Q (cfs) * 131.88 * Culy Ful Lngh (ft) * 38.00 * * # Barrels * 3 * Culy Vel US (ft /s) * 6.22 * * Q Barrel (cfs) * 43.96 * Culy Vel DS (ft /s) * 6.22 * * E.G. US. (ft) * 1704.31 * Culy Inv E1 Up (ft) * 1697.20 * * W.S. US. (ft) * 1703.97 * Culy Inv E1 Dn (ft) * 1696.20 * * E.G. DS (ft) * 1703.32 * Culy Frctn Ls (ft) * 0.56 * * W.S. DS (ft) * 1702.85 * Culy Ext Lss (ft) * 0.13 * * Delta EG (ft) * 0.99 * Culy Ent Lss (ft) * 0.30 * * Delta WS (ft) * 1.12 * Q Weir (cfs) * 2698.12 * * E.G. IC (ft) * 1704.27 * Weir Sta Lft (ft) * 976.00 * * E.G. OC (ft) * 1704.31 * Weir Sta Rgt (ft) * 1665.78 * * Culvert Control * Outlet * Weir Submerg * 0.15 * * Culy WS Inlet (ft) * 1700.20 * Weir Max Depth (ft) * 2.91 * * Culy WS Outlet (ft) * 1699.20 * Weir Avg Depth (ft) * 1.24 * * Culy Nml Depth (ft) * * Wr Flw Area (sq ft) * 853.89 * * Culy Crt Depth (ft) * 2.16 * Min E1 Weir Flow (ft) * 1701.41 * **************************************** * ** ** * * * * * * * * * * * * * * * * * * * * * * * * ** Warning: During subcritical analysis, the water surface upstream of culvert went to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 3090 INPUT Description: Station Elevation Data Sta Elev Sta 1000 1703.99 1273.58 1491.23 1702 1525.21 1564.57 1701 1603.23 1647.75 1699 1650.51 1671.09 1698 1671.1 1681.92 1702 1689.34 1764.19 1703 1768.33 1833.51 1700 1837.57 1894.08 1702 1958.79 Manning's n Values Sta n Val Sta num= 43 Elev Sta 1703 1348.33 1702 1544.81 1702 1639.91 1698 1655.28 1698 1673.29 1703 1703.43 1703 1812.87 1700 1840.26 1703 2060.76 num= 3 n Val Sta Elev Sta Elev Sta Elev 1702 1391.76 1701 1403.27 1701 1702 1549.4 1702 1558.87 1701 1702 1642.74 1701 1645.09 1699.99 1697 1662.06 1696.6 1668.84 1697 1699 1675.69 1699.99 1678.38 1701.03 1703 1721.56 1702 1750.45 1702 1702 1824.16 1701 1833.5 1700 1701 1842.78 1702 1857.35 1702 1704 n Val 16 ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 1000 .032 1639.91 .027 1689.34 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1639.91 1689.34 145.89 150.87 146.79 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 888 F CROSS SECTION OUTPUT Profile #EXISTING (B) SUB x************* xxxxxxx* xx******** x** x******* x*** xxxxxxxxx******** * *xx *xx *xxxxxxxxxx * * * * * *xx *x *xx • E.G. Elev (ft) * 1703.32 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.47 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1702.85 * Reach Len. (ft) * 145.89 * 150.87 * 146.79 * • Crit W.S. (ft) * 1702.85 * Flow Area (sq ft) * 379.43 * 181.01 * 176.72 * • E.G. Slope (ft /ft) *0.003308 * Area (sq ft) * 380.38 * 181.01 * 176.72 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 1083.95 * 1348.16 * 397.90 * * Top Width (ft) * 632.58 * Top Width (ft) * 354.81 * 48.29 * 229.48 * * Vel Total (ft /s) * 3.84 * Avg. Vel. (ft /s) * 2.86 * 7.45 * 2.25 * * Max Chl Dpth (ft) * 6.25 * Hydr. Depth (ft) * 1.11 * 3.75 * 0.77 * * Conv. Total (cfs) * 49202.2 * Conv. (cfs) * 18845.4 * 23439.0 * 6917.8 * * Length Wtd. (ft) * 149.60 * Wetted Per. (ft) * 343.00 * 50.15 * 230.02 * * Min Ch E1 (ft) * 1696.60 * Shear (lb /sq ft) * 0.23 * 0.75 * 0.16 * • Alpha * 2.05 * Stream Power (lb /ft s) * 0.65 * 5.55 * 0.36 * • Frctn Loss (ft) * 0.68 * Cum Volume (acre -ft) * 7.23 * 16.72 * 13.83 * • C & E Loss (ft) * 0.33 * Cum SA (acres) * 9.33 * 5.25 * 17.55 * * xxxxxx* xxx****** xx* x* x*********** x* x*********** x** xxxxxxx* xxx* xxx * * *x * * *x *xx *xxxxxxx * *x *x * * *x* Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross- section. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross %g/ section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, energy was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 2940 INPUT Description: 17 Station Elevation Data num= 50 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev x** xxxxxxx******* xxx** x*** x************ xx** x* xxxx *xxxxxxx * * *xxxx *x * * * * * * * * *x * *x* 100 1698.96 102.31 1698.96 204.13 1698 208.67 1698 224.05 1698 379.96 1697 441.97 1697 572.38 1697 583.43 1697 592.64 .1698 604.49 1698 640.9 1698 647.52 1698 657.01 1698 659.15 1698 659.16 1698 671.26 1695 676.81 1693 679.55 1692 682 1691.05 692 1691.25 694.82 1692 698.75 1693 702.19 1694 704.31 1695 712.92 1699 721.43 1700 730.19 1700 734.31 1699 736.78 1698 739.21 1697 739.22 1697 741.72 1696 743.88 1695 745.04 1694 746.48 1693 749.39 1692 752.5 1691 755.77 1692 759.45 1693 761.39 1694 763.22 1695 767.83 1696 789.85 1697 824.43 1698 902.88 1699 927.7 1700 931.36 1700 963.04 1699 981.04 1699 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val x********* x* xxxx* * *x * * * * * *xxxx * * * * * * *x * * * * * * * * *x 100 .032 659.16 .027 767.83 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 659.16 767.83 331.6 325.56 310.91 .3 .5 Ineffective Flow num= 1 Sta L Sta R Elev Permanent 17 888 F Left Levee Station= 659.16 Elevation= Right Levee Station= 767.83 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx • E.G. Elev (ft) * 1698.79 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 1.57 * Wt. n -Val. * * 0.027 * 0.032 * • W.S. Elev (ft) * 1697.22 * Reach Len. (ft) * 331.60 * 325.56 * 310.91 * • Crit W.S. (ft) * 1697.22 * Flow Area (sq ft) * * 275.01 * 16.54 * • E.G. Slope (ft /ft) *0.006572 1687 1234.33 1687 1251.21 * Area (sq ft) * * 275.01 * 16.54 * * Q Total (cfs) * 2830.00 * Flow (cfs) * * 2787.65 * 42.35 * * Top Width (ft) * 105.34 * Top Width (ft) * * 75.89 * 29.45 * * Vel Total (ft /s) * 9.71 * Avg. Vel. (ft /s) * * 10.14 * 2.56 * * Max Chl Dpth (ft) * 6.21 * Hydr. Depth (ft) * * 3.62 * 0.56 * * Conv. Total (cfs) * 34909.8 * Conv. (cfs) * * 34387.4 * 522.5 * * Length Wtd. (ft) * 325.45 * Wetted Per. (ft) * * 80.30 * 29.48 * * Min Ch E1 (ft) * 1691.00 * Shear (lb /sq ft) * * 1.41 * 0.23 * * Alpha * 1.08 * Stream Power (lb /ft s) * * 14.24 * 0.59 * * Frctn Loss (ft) * 2.19 * Cum Volume (acre -ft) * 6.60 * 15.93 * 13.50 * * C & E Loss (ft) * 0.14 * Cum SA (acres) * 8.73 * 5.03 * 17.11 * xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx Left Levee Station= 1401.37 Elevation= Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 2600 INPUT Description: Station Elevation Data num= 41 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 856.34 1690 863.71 1690 863.77 1690 942.2 1689 988.06 1689 990.57 1689 1006.51 1688.01 1012.76 1688.01 1050.59 1688.01 1052.67 1688.01 1099.51 1688 1225.74 1687 1234.33 1687 1251.21 1687 1281.48 1687 1335.92 1687 1363.91 1687 1378.18 1687 1381.02 1687 1384.45 1687 1401.37 1687 1405 1687 1411.04 1685 1420.57 1680 1426.01 1679 1429.5 1678.5 1433.88 1679 1438.12 1680 1455.88 1685 1462.66 1686 1469.98 1687 1545.47 1688 1573.33 1688 1620 1687 1706.72 1688 1806.29 1689 1812.46 1689 1825.17 1689 1871 1690 1940.02 1689 1996.46 1689 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx 856.34 .032 1401.37 .027 1469.98 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1401.37 1469.98 283.71 288.52 291.03 .3 .5 Left Levee Station= 1401.37 Elevation= Right Levee Station= 1469.98 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx * E.G. Elev (ft) * 1688.51 * Element * Left OB * Channel * Right OB * Vel Head (ft) * 2.05 * Wt. n -Val. * * 0.027 * * W.S. Elev (ft) * 1686.45 * Reach Len. (ft) * 283.71 * 288.52 * 291.03 * Crit W.S. (ft) * 1686.45 * Flow Area (sq ft) * * 246.10 * * E.G. Slope (ft /ft) *0.006923 * Area (sq ft) * * 246.10 * * Q Total (cfs) * 2830.00 * Flow (cfs) * * 2830.00 * * Top Width (ft) * 59.31 * Top Width (ft) * * 59.31 * 19 Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 2290 INPUT Description: Station Elevation Data num= 25 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * * * * * * * * * * * * * * * * * ** * * * * * * ** * ** 1000 1680 1006.09 1680 1156.23 1679 1360.13 1679 1365.7 1679 1369.36 1679 1369.38 1679 1372.51 1679 1390.72 1679 1392.69 1679 1394.98 1679 1405.39 1675 1409.99 1673 1413.49 1672 1415 1671.6 1423.5 1671.6 1425.15 1672 1427.11 1673 1430.77 1674 1435.15 1675 1446.67 1678 1451.91 1678.99 1545.05 1678.99 1656.86 1678.99 1856.86 1680 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .032 1390.72 .027 1451.91 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1390.72 1451.91 315.65 311.5 314.54 .3 .5 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB • E.G. Elev (ft) * Vel Total ft /s) * 11.50 * Avg. Vel. (ft 's) * * 11.50 * * 0.53 * Max Chl Dpth (ft) * 7.95 * Hydr. Depth (ft) * * 4.15 * * Reach Len. (ft) * 315.65 * Conv. Total (cfs) * 34012.8 * Conv. (cfs) * * 34012.8 * * 288.79 * 252.74 * * Length Wtd. (ft) * 288.34 * Wetted Per. (ft) * * 61.84 * * Q Total (cfs) * * Min Ch E1 (ft) * 1678.50 * Shear (lb /sq ft) * * 1.72 * 801.56 * Top Width (ft) • Alpha * 1.00 * Stream Power (lb /ft s) * * 19.78 * * 1.68 * 6.89 • Frctn Loss (ft) * 1.00 * Cum Volume (acre -ft) * 6.60 * 13.98 * 13.44 * * Conv. Total (cfs) • C & E Loss (ft) * 0.76 * Cum SA (acres) * 8.73 * 4.53 * 17.01 * 312.67 **************************************************************** * 363.41 * 63.55 * * * * * * * * * * * * **** * * *** * * * * * * * *** Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 2290 INPUT Description: Station Elevation Data num= 25 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * * * * * * * * * * * * * * * * * ** * * * * * * ** * ** 1000 1680 1006.09 1680 1156.23 1679 1360.13 1679 1365.7 1679 1369.36 1679 1369.38 1679 1372.51 1679 1390.72 1679 1392.69 1679 1394.98 1679 1405.39 1675 1409.99 1673 1413.49 1672 1415 1671.6 1423.5 1671.6 1425.15 1672 1427.11 1673 1430.77 1674 1435.15 1675 1446.67 1678 1451.91 1678.99 1545.05 1678.99 1656.86 1678.99 1856.86 1680 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 1000 .032 1390.72 .027 1451.91 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 1390.72 1451.91 315.65 311.5 314.54 .3 .5 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB • E.G. Elev (ft) * 1680.39 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.53 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1679.86 * Reach Len. (ft) * 315.65 * 311.50 * 314.54 * • Crit W.S. (ft) * 1679.86 * Flow Area (sq ft) * 256.69 * 288.79 * 252.74 * • E.G. Slope (ft /ft) *0.002080 * Area (sq ft) * 256.69 * 288.79 * 252.74 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 431.19 * 1988.76 * 410.05 * * Top Width (ft) * 801.56 * Top Width (ft) * 363.41 * 61.19 * 376.96 * * Vel Total (ft /s) * 3.55 * Avg. Vel. (ft /s) * 1.68 * 6.89 * 1.62 * * Max Chl Dpth (ft) * 8.26 * Hydr. Depth (ft) * 0.71 * 4.72 * 0.67 * * Conv. Total (cfs) * 62046.3 * Conv. (cfs) * 9453.6 * 43602.6 * 8990.1 * * Length Wtd. (ft) * 312.67 * Wetted Per. (ft) * 363.41 * 63.55 * 376.96 * * Min Ch E1 (ft) * 1671.60 * Shear (lb /sq ft) * 0.09 * 0.59 * 0.09 * • Alpha * 2.72 * Stream Power (lb /ft s) * 0.15 * 4.06 * 0.14 * • Frctn Loss (ft) * 0.65 * Cum Volume (acre -ft) * 5.76 * 12.21 * 12.60 * • C & E Loss (ft) * 0.05 * Cum SA (acres) * 7.55 * 4.13 * 15.75 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to 19 critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 2000 INPUT Description: Station Elevation Data num= 32 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 117.29 1671.5 153.88 1671 227 1670.1 264.34 1670.35 305.35 1670 333.94 1669.7 353.08 1670 375.44 1670 449.68 1671 455.31 1671 457.61 1671 460.43 1671 476.03 1671 479.66 1671 484.25 1670 496.04 1665 499.56 1664 502 1663 511 1663 513.06 1664 516.86 1665 520.69 1666 524.65 1667 529.24 1668 534.07 1669 541.85 1670 705.19 1670 739.45 1670.4 820.51 1670 862.93 1669.6 874.88 1670 958.44 1671 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 117.29 .032 476.03 .027 541.85 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 476.03 541.85 288.58 289.19 289.5 .3 .5 Left Levee Station= 476.03 Elevation= Right Levee Station= 541.85 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB * E.G. Elev (ft) * 1671.43 * Element * Left OB * Channel * Right OB * * Vel Head (ft) * 0.42 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * Ampok * W.S. Elev (ft) * 1671.01 * Reach Len. (ft) * 288.58 * 289.19 * 289.50 * * Crit W.S. (ft) * 1671.01 * Flow Area (sq ft) * 212.49 * 276.08 * 365.77 * * E.G. Slope (ft /ft) *0.002107 * Area (sq ft) * 212.49 * 276.08 * 365.77 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 342.82 * 1772.27 * 714.91 * * Top Width (ft) * 805.11 * Top Width (ft) * 322.70 * 65.82 * 416.59 * * Vel Total (ft /s) * 3.31 * Avg. Vel. (ft /s) * 1.61 * 6.42 * 1.95 * * Max Chl Dpth (ft) * 8.01 * Hydr. Depth (ft) * 0.66 * 4.19 * 0.88 * * Conv. Total (cfs) * 61646.4 * Conv. (cfs) * 7467.7 * 38605.7 * 15573.0 * * Length Wtd. (ft) * 289.21 * Wetted Per. (ft) * 322.72 * 68.17 * 416.62 * * Min Ch E1 (ft) * 1663.00 * Shear (lb /sq ft) * 0.09 * 0.53 * 0.12 * * Alpha * 2.47 * Stream Power (lb /ft s) * 0.14 * 3.42 * 0.23 * * Frctn Loss (ft) * 0.72 * Cum Volume (acre -ft) * 4.06 * 10.19 * 10.37 * * C & E Loss (ft) * 0.01 * Cum SA (acres) * 5.06 * 3.67 * 12.88 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The cross - section end points had to be extended vertically for the computed water surface. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 1710 INPUT Description: Station Elevation Data num= 34 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 100 1663.55 124.98 1663 163.64 1662.35 302.4 1662.5 321.55 1662 337.02 1662 395.49 1662 398.97 1662 402.32 1662 404.36 1662 407.58 1662 411.98 1662 420.04 1662 421.43 1662 433.13 1660 438.47 1658 443.22 1657 445 1656.1 453 1656.1 454.79 1657 20 458.15 1658 463.01 1659 466.88 1660 473.04 1661 480.53 1662 493.42 1662 535.72 1662 598.75 1662 731.83 1662 749.66 1662 854.64 1662 887.24 1661.4 916.77 1662 997.21 1663 * 165.28 * 222.73 Manning's n Values num= 3 * Area (sq ft) * 165.28 * 222.73 * 424.96 * * Q Total (cfs) Sta n Val Sta n Val Sta n Val * 963.52 * * Top Width (ft) * 853.03 ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * Vel Total (ft /s) * 3.48 * Avg. Vel. (ft /s) 100 .032 420.04 .027 480.53 .032 6.76 * Hydr. Depth (ft) * 0.58 * 3.68 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 420.04 480.53 314.37 315.94 316.2 316.3 * 62.08 .3 .5 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • E.G. Elev (ft) * 1663.33 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.46 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1662.86 * Reach Len. (ft) * 314.37 * 316.20 * 316.30 * • Crit W.S. (ft) * 1662.86 * Flow Area (sq ft) * 165.28 * 222.73 * 424.96 * • E.G. Slope (ft /ft) *0.003006 * 0.032 * * Area (sq ft) * 165.28 * 222.73 * 424.96 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 291.33 * 1575.15 * 963.52 * * Top Width (ft) * 853.03 * Top Width (ft) * 286.90 * 60.49 * 505.64 * * Vel Total (ft /s) * 3.48 * Avg. Vel. (ft /s) * 1.76 * 7.07 * 2.27 * * Max Chl Dpth (ft) * 6.76 * Hydr. Depth (ft) * 0.58 * 3.68 * 0.84 * * Conv. Total (cfs) * 51616.1 * Conv. (cfs) * 5313.6 * 28729.0 * 17573.5 * * Length Wtd. (ft) * 315.94 * Wetted Per. (ft) * 286.91 * 62.08 * 505.66 * * Min Ch E1 (ft) * 1656.10 * Shear (lb /sq ft) * 0.11 * 0.67 * 0.16 * • Alpha * 2.47 * Stream Power (lb /ft s) * 0.19 * 4.76 * 0.36 * • Frctn Loss (ft) * 0.99 * Cum Volume (acre -ft) * 2.81 * 8.53 * 7.74 * • C & E Loss (ft) * 0.01 * Cum SA (acres) * 3.04 * 3.26 * 9.82 * **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 1395 INPUT Description: Station Elevation Data num= Sta Elev Sta Elev * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 100.01 1656 109.59 1656 208.84 1657 215.62 1656 405.81 1654 440.29 1653 493.51 1653 496.45 1653 519.82 1653 521.28 1653 546.47 1649 548.07 1650 571.67 1654 585.55 1654 766.11 1654.5 798.68 1654 959.37 1655.01 993.65 1655.01 1083.04 1656 46 Sta Y * * * * * ** 163.71 222.22 473.52 499.03 533.23 556.44 611.94 857.6 1007.8 Elev Sta Elev Sta Elev 1656 172.02 1656 196.88 1657 1655 274.03 1655.01 305.21 1655.01 1653 488.16 1653 491.66 1653 1653 515.77 1653 517.89 1653 1650 537.59 1649 542 1648.7 1651 561.31 1652 566.82 1653 1653.5 649.53 1654 743.24 1654 1654 894.18 1654 917.37 1654 1654 1024.48 1654 1037.87 1655.01 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 100.01 .032 515.77 .027 571.67 .032 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 515.77 571.67 344.2 352.08 353.37 .3 .5 CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • E.G. Elev (ft) * 1655.31 * Element * Left OB * Channel * Right OB * * Vel Head (ft) * 0.50 * Wt. n -Val. * 0.032 * 0.027 * 0.032 * • W.S. Elev (ft) * 1654.61 * Reach Len. (ft) * 344.20 * 352.08 * 353.37 * • Crit W.S. (ft) * 1654.81 * Flow Area (sq ft) * 214.36 * 205.35 * 318.02 * 21 Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 1045 INPUT Description: Station Elevation Data num= 25 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 100 1648 113.1 1647 126.8 1646 148.36 1644.99 174.36 1644 180.99 1643 214.69 1642 220.17 1642 220.47 1642 231.14 1642 234.67 1643 239.85 1644 297 1646 349.66 1645.5 395.66 1646 446.3 1646 477.58 1646 650.23 1645 673.17 1645 703.06 1646 738.14 1646 743.7 1646 790.64 1647 790.65 1647 841.64 1648 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 100 .027 174.36 .027 239.85 .027 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 174.36 239.85 388.23 384.25 388.63 .3 .5 Left Levee Station= 174.36 Elevation= Right Levee Station= 239.85 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * ** * * * * * * * * ** • E.G. Elev (ft) * E.G. Slope (ft /ft) * Q Total (cfs) *0.003249 * 2830.00 * Area (sq ft) * Flow (cfs) * 214.36 * 613.53 * * 205.35 1512.90 * * 318.02 * 703.58 * * Wt. n -Val. * Top Width (ft) * 664.59 * Top Width (ft) * 190.58 * 55.90 * 418.11 * * 388.63 * * Vel Total (ft /s) * 3.84 * Avg. Vel. (ft /s) * 2.86 * 7.37 * 2.21 * * Max Chl Dpth (ft) * 6.11 * Hydr. Depth (ft) * 1.12 * 3.67 * 0.76 * * 1696.36 * Conv. Total (cfs) * 49652.6 * Conv. (cfs) * 10764.4 * 26543.9 * 12344.3 * * * Length Wtd. (ft) * 351.28 * Wetted Per. (ft) * 190.60 * 57.04 * 418.20 * * 1.30 * Min Ch E1 (ft) * 1648.70 * Shear (lb /sq ft) * 0.23 * 0.73 * 0.15 * * Length Wtd. (ft) • Alpha * 2.18 * Stream Power (lb /ft s) * 0.65 * 5.38 * 0.34 * * Shear (lb /sq ft) • Frctn Loss (ft) * 1.01 * Cum Volume (acre -ft) * 1.44 * 6.98 * 5.04 * * 0.28 * • C & E Loss (ft) * 0.01 * Cum SA (acres) * 1.32 * 2.83 * 6.46 * 0.12 * Cum SA (acres) * 0.36 * 2.34 * 2.65 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: Divided flow computed for this cross - section. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 1045 INPUT Description: Station Elevation Data num= 25 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 100 1648 113.1 1647 126.8 1646 148.36 1644.99 174.36 1644 180.99 1643 214.69 1642 220.17 1642 220.47 1642 231.14 1642 234.67 1643 239.85 1644 297 1646 349.66 1645.5 395.66 1646 446.3 1646 477.58 1646 650.23 1645 673.17 1645 703.06 1646 738.14 1646 743.7 1646 790.64 1647 790.65 1647 841.64 1648 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val 100 .027 174.36 .027 239.85 .027 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 174.36 239.85 388.23 384.25 388.63 .3 .5 Left Levee Station= 174.36 Elevation= Right Levee Station= 239.85 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * ** * * * * * * * * ** • E.G. Elev (ft) * 1646.83 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.47 * Wt. n -Val. * 0.027 * 0.027 * 0.027 * • W.S. Elev (ft) * 1646.36 * Reach Len. (ft) * 388.23 * 384.25 * 388.63 * • Crit W.S. (ft) * 1646.36 * Flow Area (sq ft) * 68.16 * 249.37 * 391.78 * • E.G. Slope (ft /ft) *0.002586 * Area (sq ft) * 68.16 * 249.37 * 391.78 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 226.80 * 1696.36 * 906.84 * * Top Width (ft) * 638.88 * Top Width (ft) * 52.53 * 65.49 * 520.87 * * Vel Total (ft /s) * 3.99 * Avg. Vel. (ft /s) * 3.33 * 6.80 * 2.31 * * Max Chl Dpth (ft) * 4.36 * Hydr. Depth (ft) * 1.30 * 3.81 * 0.75 * * Conv. Total (cfs) * 55646.4 * Conv. (cfs) * 4459.6 * 33355.5 * 17831.2 * * Length Wtd. (ft) * 385.12 * Wetted Per. (ft) * 52.58 * 65.81 * 520.93 * * Min Ch E1 (ft) * 1642.00 * Shear (lb /sq ft) * 0.21 * 0.61 * 0.12 * • Alpha * 1.91 * Stream Power (lb /ft s) * 0.70 * 4.16 * 0.28 * • Frctn Loss (ft) * 1.66 * Cum Volume (acre -ft) * 0.32 * 5.14 * 2.16 * • C & E Loss (ft) * 0.12 * Cum SA (acres) * 0.36 * 2.34 * 2.65 * Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to 22 critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 710 INPUT Description: Station Elevation Data num= 34 Expan. 190.5 404.83 272.9 255.09 263.76 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev * * * * * * * * * * * * * * * * * * * * ** * * * * * * * ** • E.G. Elev (ft) * 1632.25 100 1644 103.97 1644 147.27 1643 150.34 1641.99 155.38 1640 173.73 1635 182.08 1631.99 185.09 1631 190.5 1631 198.5 1631 202.14 1631 225.05 1631 242.22 1630 263.76 1629 284.68 1628 309.68 1628 312.62 1628 316.37 1628 331.07 1629 337.33 1630 337.36 1630 342.47 1630 350.44 1630 350.45 1630 354.69 1630 392.19 1630 404.83 1631 427.06 1631.99 434.09 1633 452.93 1634 473.98 1635 479.37 1635 503.09 1635 537.09 1635 * Length Wtd. (ft) * 255.95 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * ** * * * * * ** 100 .027 190.5 .027 404.83 .027 Bank Sta: Left Right Lengths: Left Channel Right Coeff Contr. Expan. 190.5 404.83 272.9 255.09 263.76 .3 .5 Sta CROSS SECTION OUTPUT Profile #EXISTING (B) SUB Elev Sta Elev Sta **************************************************************** * * * * * * * * * * * * * * * * * * * * ** * * * * * * * ** • E.G. Elev (ft) * 1632.25 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.86 * Wt. n -Val. * 0.027 * 0.027 * 0.027 * • W.S. Elev (ft) * 1631.39 * Reach Len. (ft) * 272.90 * 255.09 * 263.76 * • Crit W.S. (ft) * 1631.39 * Flow Area (sq ft) * 2.32 * 378.39 * 1.68 * * E.G. Slope (ft /ft) *0.008614 * Area (sq ft) * 2.32 * 378.39 * 1.68 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 5.86 * 2821.28 * 2.86 * * Top Width (ft) * 229.59 * Top Width (ft) * 6.58 * 214.33 * 8.68 * * Vel Total (ft /s) * 7.40 * Avg. Vel. (ft /s) * 2.53 * 7.46 * 1.71 * * Max Chl Dpth (ft) * 3.39 * Hydr. Depth (ft) * 0.35 * 1.77 * 0.19 * * Conv. Total (cfs) * 30491.4 * Conv. (cfs) * 63.2 * 30397.4 * 30.8 * Length Wtd. (ft) * 255.95 * Wetted Per. (ft) * 6.65 * 214.56 * 8.68 * Min Ch E1 (ft) * 1628.00 * Shear (lb /sq ft) * 0.19 * 0.95 * 0.10 * Alpha * 1.01 * Stream Power (lb /ft s) * 0.47 * 7.07 * 0.18 * Frctn Loss (ft) * 2.03 * Cum Volume (acre -ft) * 0.01 * 2.37 * 0.41 * C & E Loss (ft) * 0.04 * Cum SA (acres) * 0.10 * 1.11 * 0.29 Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 455 INPUT Description: Station Elevation Data num= 38 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev 100 1634 107.11 1634 113.19 1634 115.5 1634 117.34 1633 118.68 1632 122.34 1630 135.24 1625 137.74 1624 144.31 1623 150.46 1623 162.53 1623 234 1622 234.01 1622 236.15 1621 237.75 1620 237.76 1620 241.17 1618 242.93 1617 246.93 1616.01 249.94 1615 261.11 1615 262.52 1616.01 267.09 1617 269.09 1618 270.23 1619.01 271.63 1620 273.89 1621 274.89 1622 275.66 1623 281.82 1623 284.66 1622 291.05 1621 291.06 1621 319.42 1621 319.43 1621 332.98 1622 334.33 1623 23 Manning's n Values Sta n Val Sta * * * * * * * * * * * * * * * * * * * * * * ** 100 .027 162.53 Bank Sta: Left Right 162.53 274.89 Left Levee Station= Right Levee Station= num= 3 n Val Sta n Val .027 274.89 .027 Lengths: Left Channel Right Coeff Contr. Expan 83.85 78.6 80.52 .3 .5 162.53 Elevation= 274.89 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** • E.G. Elev (ft) * 1623.99 * Element * Left OB * Channel * Right OB * • Vel Head (ft) * 0.98 * Wt. n -Val. * 0.027 * 0.027 * 0.027 * • W.S. Elev (ft) * 1623.01 * Reach Len. (ft) * 83.85 * 78.60 * 80.52 * • Crit W.S. (ft) * 1623.01 * Flow Area (sq ft) * 0.18 * 273.75 * 89.74 * • E.G. Slope (ft /ft) *0.007296 * Area (sq ft) * 0.18 * 273.75 * 89.74 * * Q Total (cfs) * 2830.00 * Flow (cfs) * 0.04 * 2281.57 * 548.39 * * Top Width (ft) * 190.09 * Top Width (ft) * 18.29 * 112.36 * 59.44 * * Vel Total (ft /s) * 7.78 * Avg. Vel. (ft /s) * 0.22 * 8.33 * 6.11 * * Max Chl Dpth (ft) * 8.01 * Hydr. Depth (ft) * 0.01 * 2.44 * 1.51 * * Conv. Total (cfs) * 33130.7 * Conv. (cfs) * 0.5 * 26710.2 * 6420.0 * * Length Wtd. (ft) * 78.88 * Wetted Per. (ft) * 18.29 * 115.96 * 60.56 * * Min Ch E1 (ft) * 1615.00 * Shear (lb /sq ft) * 0.00 * 1.08 * 0.68 * • Alpha * 1.04 * Stream Power (lb /ft s) * 0.00 * 8.96 * 4.13 * • Frctn Loss (ft) * 0.50 * Cum Volume (acre -ft) * 0.00 * 0.46 * 0.13 * • C & E Loss (ft) * 0.19 * Cum SA (acres) * 0.02 * 0.15 * 0.09 * **************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Warning: The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning: The cross - section end points had to be extended vertically for the computed water surface. Warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning: During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. CROSS SECTION RIVER: Reach #1 REACH: Reach #1 RS: 380 INPUT Description: Station Elevation Data num= 29 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev ************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 100 1620 105.7 1619 113.61 1618 121.39 1617 129.52 1616 138.73 1615 145.31 1614 154.03 1613 155.96 1611.99 157.81 1611 162.74 1610 178.97 1605 180.56 1604.01 181.11 1603 182.61 1602 187.09 1602 190.2 1603 191.11 1604.01 193.07 1605 194.87 1606 198.45 1607 199.39 1607 212.67 1607 218.49 1608 222.84 1608 224.84 1608 238.34 1609 250.02 1610 253.56 1611 Manning's n Values num= 3 Sta n Val Sta n Val Sta n Val ***************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** 100 .027 162.74 .027 218.49 .027 Bank Sta: Left Right Coeff Contr. Expan. 162.74 218.49 .3 .5 Left Levee Station= 162.74 Elevation= Right Levee Station= 218.49 Elevation= CROSS SECTION OUTPUT Profile #EXISTING (B) SUB **************************************************************** * * * * * * * * * * * * * * * * * * * * * ** * * * * * * ** * E.G. Elev (ft) * 1612.01 * Element * Left OB * Channel * Right OB • Vel Head (ft) * 1.60 * Wt. n -Val. * 0.027 * 0.027 * 0.027 • W.S. Elev (ft) * 1610.41 * Reach Len. (ft) 24 AT * Crit W.S. (ft) * E.G. Slope (ft /ft) * *0.005657 1610.41 * Flow Area (sq ft) * Area (sq ft) * 0.41 * 0.41 * * 240.48 240.48 * * 51.90 * 51.90 * * Reach * Q Total (cfs) * 2830.00 * Flow (cfs) * 0.58 * 2539.53 * 289.90 * *Reach * Top Width (ft) * 90.72 * Top Width (ft) * 2.00 * 55.75 * 32.97 * #1 * Vel Total (ft /s) * 9.67 * Avg. Vel. (ft /s) * 1.41 * 10.56 * 5.59 * * * Max Chl Dpth (ft) * 8.41 * Hydr. Depth (ft) * 0.20 * 4.31 * 1.57 * 4680 * Conv. Total (cfs) * 37627.8 * Conv. (cfs) * 7.6 * 33765.6 * 3854.5 * * * Length Wtd. (ft) * .032* * Wetted Per. (ft) * 2.04 * 59.01 * 33.11 * .032* * Min Ch E1 (ft) * 1602.00 * Shear (lb /sq ft) * 0.07 * 1.44 * 0.55 * .027* * Alpha * 1.11 * Stream Power (lb /ft s) * 0.10 * 15.20 * 3.09 * .032* * Frctn Loss (ft) * #1 * Cum Volume (acre -ft) 3810 * .032* .032* .027* * C & E Loss (ft) * **************************************************************** #1 * Cum SA (acres) * *** * ** * ** * * * * * * * * * * * * * * * * * * *** Warning: The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. SUMMARY OF MANNING'S N VALUES River:Reach #1 Reach #1 * Reach * River Sta. * nl * n2 * n3 * n4 ******************************************** * * * * *** * * * * * * * * * * * ** * * * ** * * * * ** *Reach #1 * 5480 * .032* .027* .032* *Reach #1 * 5180 * .032* .027* .032* *Reach *Reach #1 * 4880 * .032* .027* .032* 307.36* *Reach #1 * 4680 * .032* .027* .032* .032* *Reach #1 * 4480 * .032* .027* .032* .032* *Reach #1 * 4280 * .032* .027* .032* 4680 *Reach #1 * 4080 * .032* .027* .032* #1 *Reach #1 * 3880 * .032* .027* .032* *Reach #1 * 3810 * .032* .032* .027* *Reach #1 * 3790 *Culvert * 4080 * 206.72* *Reach #1 * 3770 * .035* .027* .035* 3880 *Reach #1 * 3665 * .032* .027* .032* #1 *Reach #1 * 3400 * .032* .027* .032* *Reach #1 * 3200 * .032* .027* .032* *Reach #1 * 3130 * .032* .027* .032* *Reach #1 * 3110 *Culvert * *Reach #1 * 3090 * .032* .027* .032* *Reach #1 * 2940 * .032* .027* .032* *Reach #1 * 2600 * .032* .027* .032* *Reach #1 * 2290 * .032* .027* .032* *Reach #1 * 2000 * .032* .027* .032* *Reach #1 * 1710 * .032* .027* .032* *Reach #1 * 1395 * .032* .027* .032* *Reach #1 * 1045 * .027* .027* .027* *Reach #1 * 710 * .027* .027* .027* *Reach #1 * 455 * .027* .027* .027* *Reach #1 * 380 * .027* .027* .027* SUMMARY OF REACH LENGTHS River: Reach #1 * Reach * River Sta. * Left * Channel * Right *Reach #1 * 5480 * 286.25* 293.19* 307.36* *Reach #1 * 5180 * 295.36* 300.45* 287.94* *Reach #1 * 4880 * 270.46* 273.68* 286.87* *Reach #1 * 4680 * 214.41* 210.28* 250.24* *Reach #1 * 4480 * 225.46* 209.85* 239.32* *Reach #1 * 4280 * 193.46* 192.99* 195.79* *Reach #1 * 4080 * 206.72* 211.65* 218.14* *Reach #1 * 3880 * 69.26* 71.01* 74.36* *Reach #1 * 3810 * 39.27* 41.65* 37.64* *Reach #1 * 3790 *Culvert * *Reach #1 * 3770 * 102.56* 99.18* 101.15* 25 +++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ SUMMARY OF CONTRACTION AND EXPANSION COEFFICIENTS River: Reach #1 ++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ * Reach * River Sta. * Contr. * Expan. ++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ *Reach #1 * 5480 * .3* .5* *Reach #1 * 5180 * .3* .5* *Reach #1 * 4880 * .3* .5* *Reach #1 * 4680 * .3* .5* *Reach #1 * 4480 * .3* .5* *Reach #1 * 4280 * .3* .5* *Reach #1 * 4080 * .3* .5* *Reach #1 * 3880 * .3* .5* *Reach #1 * 3810 * .3* .5* *Reach #1 * 3790 *Culvert * *Reach #1 * 3770 * .3* .5* *Reach #1 * 3665 * .3* .5* *Reach #1 * 3400 * .3* .5*' *Reach #1 * 3200 * .3* .5* *Reach #1 * 3130 * .3* .5* *Reach #1 * 3110 *Culvert * *Reach #1 * 3090 * .3* .5* *Reach #1 * 2940 * .3* .5* *Reach #1 * 2600 * .3* .5* *Reach #1 * 2290 * .3* .5* *Reach #1 * 2000 * .3* .5* *Reach #1 * 1710 * .3* .5* *Reach #1 * 1395 * .3* .5* *Reach #1 * 1045 * .3* .5* *Reach #1 * 710 * .3* .5* *Reach #1 * 455 * .3* .5* *Reach #1 * 380 * .3* .5* ++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Profile Output Table - Standard Table 1 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ +++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ * Reach * River Sta * Q Total *Min Ch E1 *W.S. Elev *Crit W.S. *E.G. Elev *E.G. Slope * Vel Chnl *Flow Area *Top Width *Froude # Chl * + * * (cfs) * (ft) * (ft) * (ft) * (ft) * (ft /ft) * (ft /s) * (sq ft) * (ft) +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ +++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ * Reach #1 * 5480 * 2830.00 * 1770.00 * 1775.20 * 1775.20 * 1775.79 * 0.003478 * 8.12 * 647.98 * 481.17 * 0.71 * * Reach #1 ' * 5180 * 2830.00 * 1761.50 * 1766.23 * 1766.23 * 1766.87 * 0.008113 * 7.54 * 484.69 * 376.68 * 0.97 * * Reach #1 * 4880 * 2830.00 * 1752.00 * 1756.32 * 1756.32 * 1757.13 * 0.006890 * 8.75 * 445.87 * 259.57 * 0.94 * Reach #1 * 4680 * 2830.00 1743.00 * 1748.34 * 1748.34 * 1749.05 * 0.009631 * 6.89 * 428.85 * 319.17 * 0.95 * 26 *Reach #1 * 3665 * 267.49* 249.65* 249.26* *Reach #1 * 3400 * 198.74* 202.99* 201.58* *Reach #1 * 3200 * 73.09* 74.68* 76.3* *Reach #1 * 3130 * 43.68* 40.91* 42.27* *Reach #1 * 3110 *Culvert * *Reach #1 * 3090 * 145.89* 150.87* 146.79* *Reach #1 * 2940 * 331.6* 325.56* 310.91* *Reach #1 * 2600 * 283.71* 288.52* 291.03* *Reach #1 * 2290 * 315.65* 311.5* 314.54* *Reach #1 * 2000 * 288.58* 289.19* 289.5* *Reach #1 * 1710 * 314.37* 316.2* 316.3* *Reach #1 * 1395 * 344.2* 352.08* 353.37* *Reach #1 * 1045 * 388.23* 384.25* 388.63* *Reach #1 * 710 * 272.9* 255.09* 263.76* *Reach #1 * 455 * 83.85* 78.6* 80.52* *Reach #1 * 380 ++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ +++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ SUMMARY OF CONTRACTION AND EXPANSION COEFFICIENTS River: Reach #1 ++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ * Reach * River Sta. * Contr. * Expan. ++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ *Reach #1 * 5480 * .3* .5* *Reach #1 * 5180 * .3* .5* *Reach #1 * 4880 * .3* .5* *Reach #1 * 4680 * .3* .5* *Reach #1 * 4480 * .3* .5* *Reach #1 * 4280 * .3* .5* *Reach #1 * 4080 * .3* .5* *Reach #1 * 3880 * .3* .5* *Reach #1 * 3810 * .3* .5* *Reach #1 * 3790 *Culvert * *Reach #1 * 3770 * .3* .5* *Reach #1 * 3665 * .3* .5* *Reach #1 * 3400 * .3* .5*' *Reach #1 * 3200 * .3* .5* *Reach #1 * 3130 * .3* .5* *Reach #1 * 3110 *Culvert * *Reach #1 * 3090 * .3* .5* *Reach #1 * 2940 * .3* .5* *Reach #1 * 2600 * .3* .5* *Reach #1 * 2290 * .3* .5* *Reach #1 * 2000 * .3* .5* *Reach #1 * 1710 * .3* .5* *Reach #1 * 1395 * .3* .5* *Reach #1 * 1045 * .3* .5* *Reach #1 * 710 * .3* .5* *Reach #1 * 455 * .3* .5* *Reach #1 * 380 * .3* .5* ++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ Profile Output Table - Standard Table 1 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ +++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ * Reach * River Sta * Q Total *Min Ch E1 *W.S. Elev *Crit W.S. *E.G. Elev *E.G. Slope * Vel Chnl *Flow Area *Top Width *Froude # Chl * + * * (cfs) * (ft) * (ft) * (ft) * (ft) * (ft /ft) * (ft /s) * (sq ft) * (ft) +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ +++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ * Reach #1 * 5480 * 2830.00 * 1770.00 * 1775.20 * 1775.20 * 1775.79 * 0.003478 * 8.12 * 647.98 * 481.17 * 0.71 * * Reach #1 ' * 5180 * 2830.00 * 1761.50 * 1766.23 * 1766.23 * 1766.87 * 0.008113 * 7.54 * 484.69 * 376.68 * 0.97 * * Reach #1 * 4880 * 2830.00 * 1752.00 * 1756.32 * 1756.32 * 1757.13 * 0.006890 * 8.75 * 445.87 * 259.57 * 0.94 * Reach #1 * 4680 * 2830.00 1743.00 * 1748.34 * 1748.34 * 1749.05 * 0.009631 * 6.89 * 428.85 * 319.17 * 0.95 * 26 ERRORS WARNINGS AND NOTES Errors Warnings and Notes for Plan : Subcritical River: Reach #1 Reach: Reach #1 RS: 5480 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 5180 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. 27 * Reach 7.82 * #1 * 374.83 4480 * 251.27 * * 2830.00 * 0.93 * 1737.00 * 1741.90 * 1741.90 * 1742.85 * 0.008992 * * Reach #1 * 4280 * 2830.00 * 1732.10 * 1736.96 * 1736.96 * 1737.57 * 0.005117 * 7.36 * 560.37 * 957.31 * 0.81 * * Reach #1 * 4080 * 2830.00 * 1725.70 * 1731.30 * 1731.30 * 1731.75 * 0.004151 * 7.52 * 719.62 * 1010.02 * 0.74 * * Reach #1 * 3880 * 2830.00 * 1720.15 * 1723.99 * 1723.99 * 1726.39 * 0.024196 * 15.73 * 259.37 * 298.48 * 1.72 * * Reach #1 * 3810 * 2830.00 * 1718.10 * 1723.60 * 1722.69 * 1723.90 * 0.002691 * 5.13 * 648.21 * 355.22 * 0.50 * * Reach * #1 * * 3790 * * Culvert * * * Reach #1 * 3770 * 2830.00 * 1717.23 * 1722.21 * 1722.21 * 1722.89 * 0.006453 * 9.11 * 512.14 * 392.13 * 0.90 * * Reach #1 * 3665 * 2830.00 * 1713.10 * 1718.46 * 1718.46 * 1719.18 * 0.005082 * 8.83 * 521.17 * 325.50 * 0.83 * * Reach #1 * 3400 * 2830.00 * 1706.00 * 1710.91 * 1710.91 * 1711.76 * 0.004646 * 8.85 * 485.46 * 319.00 * 0.81 * * Reach #1 * 3200 * 2830.00 * 1699.99 * 1705.72 * 1705.72 * 1706.27 * 0.003098 * 7.66 * 676.68 * 601.98 * 0.67 * * Reach #1 * 3130 * 2830.00 * 1697.70 * 1703.97 * 1703.97 * 1704.50 * 0.002976 * 7.73 * 726.31 * 590.39 * 0.65 * * Reach * #1 * * 3110 * * Culvert * * Reach #1 * 3090 * 2830.00 * 1696.60 * 1702.85 * 1702.85 * 1703.32 * 0.003308 * 7.45 * 737.17 * 632.58 * 0.68 * * Reach #1 * 2940 * 2830.00 * 1691.00 * 1697.22 * 1697.22 * 1698.79 * 0.006572 * 10.14 * 291.55 * 105.34 * 0.94 * * Reach #1 * 2600 * 2830.00 * 1678.50 * 1686.45 * 1686.45 * 1688.51 * 0.006923 * 11.50 * 246.10 * 59.31 * 0.99 * * Reach #1 * 2290 * 2830.00 * 1671.60 * 1679.86 * 1679.86 * 1680.39 * 0.002080 * 6.89 * 798.22 * 801.56 * 0.56 * * Reach #1 * 2000 * 2830.00 * 1663.00 * 1671.01 * 1671.01 * 1671.43 * 0.002107 * 6.42 * 854.34 * 805.11 * 0.55 * * Reach #1 * 1710 * 2830.00 * 1656.10 * 1662.86 * 1662.86 * 1663.33 * 0.003006 * 7.07 * 812.98 * 853.03 * 0.65 * Reach #1 * 1395 * 2830.00 1648.70 * 1654.81 * 1654.81 * 1655.31 * 0.003249 * 7.37 * 737.72 * 664.59 * 0.68 * * Reach #1 * 1045 * 2830.00 * 1642.00 * 1646.36 * 1646.36 * 1646.83 * 0.002586 * 6.80 * 709.31 * 638.88 * 0.61 * * Reach #1 * 710 * 2830.00 * 1628.00 * 1631.39 * 1631.39 * 1632.25 * 0.008614 * 7.46 * 382.38 * 229.59 * 0.99 * * Reach #1 * 455 * 2830.00 * 1615.00 * 1623.01 * 1623.01 * 1623.99 * 0.007296 * 8.33 * 363.67 * 190.09 * 0.94 * * Reach #1 * 380 * 2830.00 * 1602.00 * 1610.41 * 1610.41 * 1612.01 * 0.005657 * 10.56 * 292.79 * 90.72 * 0.90 * ERRORS WARNINGS AND NOTES Errors Warnings and Notes for Plan : Subcritical River: Reach #1 Reach: Reach #1 RS: 5480 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 5180 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. 27 Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. River: Reach #1 Reach: Reach #1 RS: 4880 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 4680 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. River: Reach #1 Reach: Reach #1 RS: 4480 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross - section. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 4280 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. 28 Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 4080 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 3880 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross - section. Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 3770 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The cross - section end points had to be extended vertically for the computed water surface. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, energy was used. River: Reach #1 Reach: Reach #1 RS: 3665 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross - section. AOONNI Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated WIG water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 3400 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross - section. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 3200 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross - section. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 3130 Profile: EXISTING (B) SUB Warning:During subcritical analysis, the water surface upstream of culvert went to critical depth. River: Reach #1 Reach: Reach #1 RS: 3110 Profile: EXISTING (B) SUB Warning:During subcritical analysis, the water surface upstream of culvert went to critical depth. River: Reach #1 Reach: Reach #1 RS: 3090 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross - section. Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, energy was used. River: Reach #1 Reach: Reach #1 RS: 2940 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross- section. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. LOV Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The 30 program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 2600 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Note: Multiple critical depths were found at this location. The critical depth with the lowest, valid, water surface was used. River: Reach #1 Reach: Reach #1 RS: 2290 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 2000 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The cross - section end points had to be extended vertically for the computed water surface. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. River: Reach #1 Reach: Reach #1 RS: 1710 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 1395 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:Divided flow computed for this cross - section. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. 31 Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 1045 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 710 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth for the water surface and continued on with the calculations. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. River: Reach #1 Reach: Reach #1 RS: 455 Profile: EXISTING (B) SUB Warning:The energy equation could not be balanced within the specified number of iterations. The program used critical depth �. for the water surface and continued on with the calculations. Warning:The cross - section end points had to be extended vertically for the computed water surface. Warning:The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. Warning:The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. Warning:During the standard step iterations, when the assumed water surface was set equal to critical depth, the calculated water surface came back below critical depth. This indicates that there is not a valid subcritical answer. The program defaulted to critical depth. Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. River: Reach #1 Reach: Reach #1 RS: 380 Profile: EXISTING (B) SUB Warning:The parabolic search method failed to converge on critical depth. The program will try the cross section slice /secant method to find critical depth. 32 A EXHIBIT "A ": CURRENT FEMA FLOOD INSURANCE RATE MAP (FIRM) L44] Cam] "A-1": EXHIBIT CURRENT FEMA FLOOD INSURANC E RATE MAP (FIRM) m EXHIBIT "A -2 CURRENT FEMA FLOOD INSURANCE RATE MAP (FIRM) G EXHIBIT "B ": HAWKER - CRAWFORD EXISTING FLOOD PLAIN MAP M cc » . EXHIBIT D . PROJECT TOPOGRAPHIC MAP (1" =200' AND 1 -FOOT CONTOURS) A 11 10083 1774.65 HV -22 10082 1761.05 HV -21 J File Editor Points file - AERIAL.PTS A Point No. Northina I Easdng I Elevation I Descriptor/Name 11 1885460. 583000 !6721677.133000:1973.970000 HV-11 2'1880111. 191000 '6721674.30400011621.040000 1HV -2 311881502.654000 .11800011673.910000 IHV -3 4'1882837.15600016724289 .120000!1752.990000 iHV -4 5 :1882766. 80300016723013 .i11000i1 7 01.950000 iHV -5 611882805.880000 6721692.328000 1667.460000 IHV -6 1007841884391.68200016723476 .80600011740.450000 IHV -24 1008111882845. 479000 6723477.331000 1711.800000 1HV6 10084:1884785.152000 6724603.93400011795.080000 IHV -23 100831883792.496000 6725299.16900011774.650000 ,HV -22 100821682863.61600016725277 .29200011761.050000 iHV -21 1' .04100011576.880000 IHV -1 1011884057.89400016719150 ' 31600011845.620000 IHV -10 12'1885386.871000 6720395.42900012016.860000 IHV -12 13 1HV -13 14 ;1884780.547000 .406000!1990.220000 1HV -14 1511882886. 234000 16719137.36500011740.530000 iHV -15 16il881527.062000 6719501.32200011652.970000 HV -16 19;1880210.385000 6719581.852000 1589.480000 IHV -19 7' 1882886. 61300016720424 .84700011692.000000 IHV -7 8;1884081. 801000 6720347.676000;1749.990000 1HV -8 17'1881504.51400016721089 .59400011635.540000 1HV -17 1811880170.10700016720521 .186000!1603.6 IHV -18 911884172.52700016721414 .235000`1720.160000 iHV -9 Page 1 m EXHIBIT "E ": TTM NO. 16325-1 AND TTM 16326 (1" =1009)