Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4854-23
IRRIGATION SCHEDULES FOR THE FONTANA CAMPUS PARKING LOT NEW REMOTE CONTROL VALVE SECTIONS ONLY IRRIGATION CONTROLLER "A" VALVE # EQUIPMENT D.E PLANT MATERIAL Kc P. R. (IN/H) JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC A36 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A37 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A38 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 1 5 9 13 17 18 18 15 9 3 1 A39 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A40 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A41 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A42 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A43 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A44 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 1 17 18 18 15 9 3 1 A45 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A46 BUBBLERS 0.9 Shrubs/Trees 0.6 5.35 0 0 1 1 2 2 2 2 2 1 0 0 A47 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A48 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A49 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A50 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A51 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A52 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A53 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 A54 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 IRRIGATION CONTROLLER "C" VALVE # EQUIPMENT D.E PLANT MATERIAL Kc P. R. (IN/H) JAN FEB MAR I APR MAY JUN I JUL AUG SEP OCT I NOV DEC C1 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 C2 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 C3 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 1 18 15 9 3 1 C4 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 C5 BUBBLERS 0.9 Shrubs/Trees 0.6 5.35 0 0 1 1 2 2 2 2 2 1 0 0 C6 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 C7 DRIP 0.9 Turf 0.8 0.96 0 2 5 8 12 15 16 16 13 8 3 1 IRRIGATION CONTROLLER "E" VALVE # EQUIPMENT D.E PLANT MATERIAL Kc P. R. (IN/H) JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC E21 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 E22 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 E23 BUBBLERS 0.9 Shrubs/Trees 0.6 5.35 0 0 1 1 2 2 2 2 2 1 0 0 E24 DRIP 0.9 Turf 0.8 0.96 0 2 5 8 12 15 16 16 13 8 3 1 DATA INDUSTRIAL IR -250B m NETAFIM FILTER (1") 2.1 ■ EXISTING BACKFLOW PREVENTER , SIZE INDICATED N/A TOTAL SYSTEM LOSSES 32.19 REMOTE CONTROL VALVE (1-1/4-) 0.85 N/A PRESSURE NEEDED AT FARTHEST HEAD 30 N/A IRRIGATION CONTROLLER AT MILLER FITNESS CENTER VALVE # EQUIPMENT D.E PLANT MATERIAL Kc P. R. (IN/H) JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC X1 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 IRRIGATION CONTROLLER AT ARROW BLVD. VALVE # EQUIPMENT D.E PLANT MATERIAL Kc P. R. (IN/H) JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC X1 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 X2 DRIP 0.9 Shrubs/Trees 0.6 0.64 0 2 5 9 13 17 18 18 15 9 3 1 FITTINGS 1 0.2 NETAFIM TLSOV DETAIL NO. 4 GATE VALVE 0.14 IRRIGATION METER (2-) 0.3 REV. MASTER VALVE (2') 1.62 IRRIGATION WATER METER , SIZE INDICATED BACKFLOW PREVENTER (2-) 13 NOTE: 1 -THE IRRIGATION SCHEDULES ARE SHOWN FOR GUIDELINE USE ONLY AND ARE TO BE MODIFIED ACCORDINGLY AS THE WEATHER CHANGES. 2 -IT IS BASED ON AVERAGE EVAPOTRANSPIRATION FOR SAN BERNARDINO COUNTY, FONTANA. AREA. MORE DAILY ACCURATE DATA CAN BE OBTAINED BY CONTACTING: CALIFORNIA DEPARTMENT OF WATER RESOURCES, OFFICE OF WATER CONSERVATION P.O. BOX 942836 SACRAMENTO, CA 94236-0001 (916) 653-7366. 3 -THE NUMBERS SHOWN ON THE ABOVE WATER CHART ARE THE MINUTES PER DAY FOR EACH STATION, INA SEVEN DAY WEEK. i.e, VALVE #A-36 IN JULY WILL NEED: 18X7=126 MIN./WEEK IF WE IRRIGATED ONLY FIVE DAYS A WEEK THEN VALVE A-36 WILL NEED: 126/5= 25.2 MIN.(APPROX) PER DAY FOR FIVE DAYS. 4 -THEORETICALLY, NOVEMBER TROUGH MARCH DO NOT REQUIRE IRRIGATION. BUT, WATERING, TO SOME DEGREE, WILL BE REQUIRED. UNUSUALLY HOT WEATHER WILL REQUIRE IRRIGATION ADJUSTMENT AS WEATHER CHANGES. 5 -VALVES ON SLOPES WILL REQUIRED THE AMOUNT OF IRRIGATION AS STATED ON THE WATER CHART, BUT IRRIGATION CONTRACTOR WILL HAVE TO PROGRAM THE CONTROLLER IN CYCLES IN SUCH A WAY AS TO AVOID RUN-OFF. IN ORDER TO DO THIS, HE MUST TURN VALVES ON AND OBSERVE AMOUNT OF TIME IT TAKES UNTIL RUN-OFF STARTS. THIS WILL BE THE TIME FOR EACH IRRIGATION CYCLE. e.g., IF, FOR VALVE C-1, THE RUN-OFF STARTS AFTER 6 MINUTES OF IRRIGATION THEN VALVE C-' SHOULD BE PROGRAMMED TO 3 CYCLES OF 6 MINUTES EACH TO COMPLETE A TOTAL OF 18 MINUTES/DAY OF IRRIGATION IN JULY. NOTES (TYPICAL): 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.) INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2) MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE SITE. 3 ADJUST ALL SPRINKLERS FOR HEAD-TO-HEAD COVERAGE. 4 INSTALL BACKFLOW PREVENTER IN GROUND COVER OR SHRUB AREA, ONLY. 5 AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE PRO- GRAMMED TO IRRIGATE SOLELY DURING NIGHTTIME. GENERAL IRRIGATION NOTES: 1. THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE MAXIMUM FLOW DEMAND SHOWN ON THE DRAWINGS AT EACH POINT OF CONNECTION. THE CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION, REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S AUTHORIZED REPRESENTATIVE. 2. THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHERE POSSIBLE. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEAN FILL SAND SHALL BE INSTALLED ABOVE AND BELOW PIPING. 3. BEFORE ANY WORK COMMENCES, A CONFERENCE SHALL BE HELD WITH THE OWNER'S REPRESENTATIVE, THE CONTRACTOR AND THE CITY REGARDING GENERAL REQUIREMENTS OF THIS WORK. 4. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT UTILITIES AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND HE IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO, THESE LINES OR STRUCTURES. 5. CONTRACTOR AGREES THAT HE SHALL ASSUME COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, THIS REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND CONTRACTOR AGREES TO DEFEND AND INDEMNIFY AND HOLD OWNER AND DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 6. DO NOT INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS, IN THE FIELD, THAT OBSTRUCTIONS, GRADE DIFFERENCES, OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CON- SIDERED IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM OPERATING FLOW FOR EACH SYSTEM. 8. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN SHRUB OR GROUND COVER AREAS SHALL BE INSTALLED SO THAT THE TOP OF THE SPRINKLER HEAD IS 1 " (INCH) ABOVE FINISHED GRADE. 9. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN LAWN AREAS SHALL BE INSTALLED SO THE TOP OF THE SPRINKLER HEAD IS FLUSH WITH ADJACENT SIDE- WALK OR CURB. 10. IN OPEN SEEDED LAWN AREAS SET TOP OF POP-UP TYPE SPRINKLER HEADS 3" ABOVE FINISH GRADE UNTIL LAWN IS ESTABLISHED. LOWERING OF ALL LAWN HEADS BY THE CONTRACTOR SO THAT THE TOP OF THE SPRINKLER HEADS IS FLUSH WITH FINISHED GRADE, SHALL BE ACCOMPLISHED WITHIN TEN (10) DAYS AFTER NOTIFICATION BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 11. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE DESIGNATED ON THE PLANS. 12. 110/120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL OUTLET TO THE AUTOMATIC CONTROLLER. 13. INSTALL ALL PIPE MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC MALE PIPE THREADS ON ALL SPRINKLER SWING JOINT AND VALVE ASSEMBLIES. 14. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS WORK WITH THE SUBCONTRACTORS FOR THE LOCATION AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING STRUCTURES, ETC. 15. IN ADDITION TO THE CONTROL WIRE SLEEVES AND PIPE SLEEVES SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE AND PIPE SLEEVES OF SUFFICIENT SIZE UNDER ALL PAVED AREAS. IRRIGATION METER 3 MANUF. & PART NO. SYSTEM VALVE SECTION C-7 CALCULATION FLOW 8 GPM REMOTE CONTROL VALVE , SIZE INDICATED SECTION HW PIPE TYPE .C. IN. DIA. (INCHES) PIPE LENGTH GPM ACCUM. G.P.M (FEET) PRESSURE LOSS (PSI) v (ft/s) 1 150 PVC SCH. 40 0.824 70 3.41 3.41 0.74 2.05 MAIN 1 150 PVC class 315 2.449 480 70 70 6.83 4.76 SUPPLY 140 Type "K" copper 1.959 50 70 70 2.4 7.44 1.61 200 19 19 1.96 2.99 MAIN II 150 PVC class 315 2.023 290 19 19 IRRIGATION METER (2-) 3.8 SUPPLY 140 Type "K" copper 1.959 BACKFLOW PREVENTER (2') 13 1 2.02 LF LINE FLUSHING VALVE - PVC PIPE CONNECTION NETAFIM TLSOV FITTINGS 1 0.2 NETAFIM TLSOV DETAIL NO. 4 GATE VALVE 0.14 IRRIGATION METER (2-) 0.3 REV. MASTER VALVE (2') 1.62 IRRIGATION WATER METER , SIZE INDICATED BACKFLOW PREVENTER (2-) 13 jF�\P CHECKED K Y: BM FLOW SENSOR (1-1/2') 1 23 39 FITTINGS 0.41 NETAFIM FILTER (1') 2.1 CITY DATE GATE VALVE REMOTE CONTROL VALVE (1-) 0.85 ELEVATION CHANGES -1.29 FLOW SENSOR, SIZE INDICATED DATA INDUSTRIAL IR -250B m NETAFIM FILTER (1") 2.1 ■ EXISTING BACKFLOW PREVENTER , SIZE INDICATED N/A TOTAL SYSTEM LOSSES 32.19 REMOTE CONTROL VALVE (1-1/4-) 0.85 N/A PRESSURE NEEDED AT FARTHEST HEAD 30 N/A ELEVATION CHANGES 2.4 PRESSURE NEEDED AT P.O.0 62.19 EXISTING GATE VALVE, PIPE SIZE N/A TOTAL SYSTEM LOSSES 21.51 STATIC WATER PRESSURE 75-91 N/A TORO SENTINEL ASSEMBLY. CONTACT TOM RADEN TOTAL SYSTEM LOSSES SET PRESSURE REDUCING VALVE AT 70 NOTES (TYPICAL): 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.) INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2) MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE SITE. 3 ADJUST ALL SPRINKLERS FOR HEAD-TO-HEAD COVERAGE. 4 INSTALL BACKFLOW PREVENTER IN GROUND COVER OR SHRUB AREA, ONLY. 5 AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE PRO- GRAMMED TO IRRIGATE SOLELY DURING NIGHTTIME. GENERAL IRRIGATION NOTES: 1. THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE MAXIMUM FLOW DEMAND SHOWN ON THE DRAWINGS AT EACH POINT OF CONNECTION. THE CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION, REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S AUTHORIZED REPRESENTATIVE. 2. THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHERE POSSIBLE. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEAN FILL SAND SHALL BE INSTALLED ABOVE AND BELOW PIPING. 3. BEFORE ANY WORK COMMENCES, A CONFERENCE SHALL BE HELD WITH THE OWNER'S REPRESENTATIVE, THE CONTRACTOR AND THE CITY REGARDING GENERAL REQUIREMENTS OF THIS WORK. 4. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT UTILITIES AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND HE IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO, THESE LINES OR STRUCTURES. 5. CONTRACTOR AGREES THAT HE SHALL ASSUME COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, THIS REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND CONTRACTOR AGREES TO DEFEND AND INDEMNIFY AND HOLD OWNER AND DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 6. DO NOT INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS, IN THE FIELD, THAT OBSTRUCTIONS, GRADE DIFFERENCES, OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CON- SIDERED IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM OPERATING FLOW FOR EACH SYSTEM. 8. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN SHRUB OR GROUND COVER AREAS SHALL BE INSTALLED SO THAT THE TOP OF THE SPRINKLER HEAD IS 1 " (INCH) ABOVE FINISHED GRADE. 9. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN LAWN AREAS SHALL BE INSTALLED SO THE TOP OF THE SPRINKLER HEAD IS FLUSH WITH ADJACENT SIDE- WALK OR CURB. 10. IN OPEN SEEDED LAWN AREAS SET TOP OF POP-UP TYPE SPRINKLER HEADS 3" ABOVE FINISH GRADE UNTIL LAWN IS ESTABLISHED. LOWERING OF ALL LAWN HEADS BY THE CONTRACTOR SO THAT THE TOP OF THE SPRINKLER HEADS IS FLUSH WITH FINISHED GRADE, SHALL BE ACCOMPLISHED WITHIN TEN (10) DAYS AFTER NOTIFICATION BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 11. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE DESIGNATED ON THE PLANS. 12. 110/120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL OUTLET TO THE AUTOMATIC CONTROLLER. 13. INSTALL ALL PIPE MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC MALE PIPE THREADS ON ALL SPRINKLER SWING JOINT AND VALVE ASSEMBLIES. 14. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS WORK WITH THE SUBCONTRACTORS FOR THE LOCATION AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING STRUCTURES, ETC. 15. IN ADDITION TO THE CONTROL WIRE SLEEVES AND PIPE SLEEVES SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE AND PIPE SLEEVES OF SUFFICIENT SIZE UNDER ALL PAVED AREAS. IRRIGATION METER 2 MANUF. & PART NO. SYSTEM VALVE SECTION A-39 CALCULATION FLOW 19 GPM REMOTE CONTROL VALVE , SIZE INDICATED SECTION HW .C. PIPE TYPE IN. DIA. (INCHES) PIPE LENGTH GPM JACCUM. G.P.M (FEET) PRESSURE LOSS (PSI) v (ft/s) 1 150 PVC SCH. 40 0.824 35 3.41 3.41 0.37 2.05 2 150 PVC SCH. 40 1.049 130 4.25 4.25 0.64 1.58 MAIN 1 150 PVC class 315 1.61 200 19 19 1.96 2.99 MAIN II 150 PVC class 315 2.023 290 19 19 0.93 1.89 SUPPLY 140 Type "K" copper 1.959 50 1 19 19 0.21 1 2.02 LF LINE FLUSHING VALVE - PVC PIPE CONNECTION NETAFIM TLSOV DETAIL NO. 4 IRRIGATION METER (2-) 0.2 NETAFIM TLSOV DETAIL NO. 4 GATE VALVE, PIPE SIZE 2-1/2" AND SMALLER, NIBCO T-113 IRRIGATION METER (2-) 0.3 REV. IRRIGATION WATER METER , SIZE INDICATED BACKFLOW PREVENTER (2-) 13 jF�\P CHECKED K Y: BM UNDER CIVIL WORK DRAWING NO.: 4854 23 39 FITTINGS 0.41 DETAIL 510 ENGR. CITY DATE GATE VALVE 0.02 FEBCO 860 W/650A STRAINER MASTER VALVE (1-1/2-) 1 FLOW SENSOR, SIZE INDICATED DATA INDUSTRIAL IR -250B m NETAFIM FILTER (1") 2.1 ■ EXISTING BACKFLOW PREVENTER , SIZE INDICATED N/A N/A 0 REMOTE CONTROL VALVE (1-1/4-) 0.85 N/A EXISTING REMOTE CONTROL VALVE TO BE N/A N/A ELEVATION CHANGES 2.4 N EXISTING GATE VALVE, PIPE SIZE N/A TOTAL SYSTEM LOSSES 21.51 EXISTING IRRIGATION CONTROLLER N/A N/A TORO SENTINEL ASSEMBLY. CONTACT TOM RADEN TOTAL SYSTEM LOSSES 24.19 © DETAIL 505 PRESSURE NEEDED AT FARTHEST HEAD 30 m QUICK COUPLING VALVE HUNTER HQ-44LRC DETAIL 521 PRESSURE NEEDED AT P.O.0 54.19 2" AND 2-1/2" USE PVC CLASS 315 SPECIFICATION ML 1-1/2" AND SMALLER USE PVC SC. 40 STATIC WATER PRESSURE 75.91 EXISTING SUPPLY LINE , SIZE INDICATED N/A N/A NON PRESSURE LINE , SIZE INDICATED SET PRESSURE REDUCING VALVE AT 65 NOTES (TYPICAL): 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.) INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2) MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE SITE. 3 ADJUST ALL SPRINKLERS FOR HEAD-TO-HEAD COVERAGE. 4 INSTALL BACKFLOW PREVENTER IN GROUND COVER OR SHRUB AREA, ONLY. 5 AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE PRO- GRAMMED TO IRRIGATE SOLELY DURING NIGHTTIME. GENERAL IRRIGATION NOTES: 1. THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE MAXIMUM FLOW DEMAND SHOWN ON THE DRAWINGS AT EACH POINT OF CONNECTION. THE CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION, REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S AUTHORIZED REPRESENTATIVE. 2. THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHERE POSSIBLE. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEAN FILL SAND SHALL BE INSTALLED ABOVE AND BELOW PIPING. 3. BEFORE ANY WORK COMMENCES, A CONFERENCE SHALL BE HELD WITH THE OWNER'S REPRESENTATIVE, THE CONTRACTOR AND THE CITY REGARDING GENERAL REQUIREMENTS OF THIS WORK. 4. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT UTILITIES AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND HE IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO, THESE LINES OR STRUCTURES. 5. CONTRACTOR AGREES THAT HE SHALL ASSUME COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, THIS REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND CONTRACTOR AGREES TO DEFEND AND INDEMNIFY AND HOLD OWNER AND DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 6. DO NOT INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS, IN THE FIELD, THAT OBSTRUCTIONS, GRADE DIFFERENCES, OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CON- SIDERED IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM OPERATING FLOW FOR EACH SYSTEM. 8. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN SHRUB OR GROUND COVER AREAS SHALL BE INSTALLED SO THAT THE TOP OF THE SPRINKLER HEAD IS 1 " (INCH) ABOVE FINISHED GRADE. 9. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN LAWN AREAS SHALL BE INSTALLED SO THE TOP OF THE SPRINKLER HEAD IS FLUSH WITH ADJACENT SIDE- WALK OR CURB. 10. IN OPEN SEEDED LAWN AREAS SET TOP OF POP-UP TYPE SPRINKLER HEADS 3" ABOVE FINISH GRADE UNTIL LAWN IS ESTABLISHED. LOWERING OF ALL LAWN HEADS BY THE CONTRACTOR SO THAT THE TOP OF THE SPRINKLER HEADS IS FLUSH WITH FINISHED GRADE, SHALL BE ACCOMPLISHED WITHIN TEN (10) DAYS AFTER NOTIFICATION BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 11. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE DESIGNATED ON THE PLANS. 12. 110/120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL OUTLET TO THE AUTOMATIC CONTROLLER. 13. INSTALL ALL PIPE MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC MALE PIPE THREADS ON ALL SPRINKLER SWING JOINT AND VALVE ASSEMBLIES. 14. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS WORK WITH THE SUBCONTRACTORS FOR THE LOCATION AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING STRUCTURES, ETC. 15. IN ADDITION TO THE CONTROL WIRE SLEEVES AND PIPE SLEEVES SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE AND PIPE SLEEVES OF SUFFICIENT SIZE UNDER ALL PAVED AREAS. PVC PIPE NOTES: 1) MAIN LINE PIPE AND FITTINGS: 2-1/2" AND SMALLER USE SOLVENT WELD PIPE WITH PVC SCHEDULE 80 FITTINGS. TYPICAL. 2) LATERAL PIPE AND FITTINGS: USE SOLVENT WELD PIPE WITH PVC SCHEDULE 80 FITTINGS. TYPICAL. EXISTING TREES: WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING TREES, USE ALL POSSIBLE CARE TO AVOID INJURY TO TREES AND TREE ROOTS. EXCAVATION IN AREAS WHERE 2 INCH AND LARGER ROOTS OCCUR SHALL BE DONE BY HAND. ROOTS 2 INCHES AND LARGER IN DIAMETER, SHALL BE TUNNELED UNDER AND SHALL BE HEAVILY WRAPPED IN BURLAP, TO PREVENT SCARRING OR EXCESSIVE DRYING. WHERE A DITCHING MACHINE IS RUN CLOSE TO TREES HAVING ROOTS SMALLER THAN 2 INCHES IN DIAMETER, THE WALL OF THE TRENCH ADJACENT TO THE TREE SHALL BE HAND TRIMMED, MAKING CLEAN CUTS THROUGH. ROOTS 1 INCH AND LARGER IN DIAMETER SHALL BE PAINTED WITH TWO COATS OF TREE SEAL, OR EQUAL. TRENCHES ADJACENT TO TREES WOULD BE CLOSED WITHIN 24 HOURS. WHERE THIS IS NOT POSSIBLE, THE SIDE OF THE TRENCH ADJACENT TO THE TREE SHALL BE KEPT SHADED WITH BURLAP OR CANVAS. IRRIGATION LEGEND GENERAL LEGEND SYM. IRRIGATION METER 1 MANUF. & PART NO. SYSTEM VALVE SECTION A-40 CALCULATION FLOW 15 GPM REMOTE CONTROL VALVE , SIZE INDICATED SECTION HW 'C' PIPE TYPE IN. DIA. (INCHES) PIPE LENGTH GPM ACCUM. G.P.M (FEET) PRESSURE LOSS (PSI) v (ft/s) 1 150 PVC SCH. 40 1.049 55 5.26 5.26 0.4 1.95 MAIN 1 150 PVC class 315 1.61 350 15 15 2.21 2.36 MAIN 11 150 PVC class 315 2.023 300 15 15 0.62 1.5 SUPPLY 1 140 Type "K" copper 1.959 50 15 15 0.14 1.59 SCALE: N.T.S. 18-35 GPM USE 1-1/2" NETAFIM PRV15035V2K USE REDUCING BUSHING TO CONNECT EQUIPMENT OF DIFFERENT SIZES TOGETHER LF LINE FLUSHING VALVE - PVC PIPE CONNECTION NETAFIM TLSOV DETAIL NO. 4 IRRIGATION METER (2-) 0.2 NETAFIM TLSOV DETAIL NO. 4 GATE VALVE, PIPE SIZE 2-1/2" AND SMALLER, NIBCO T-113 BACKFLOW PREVENTER (2-) 13 REV. IRRIGATION WATER METER , SIZE INDICATED FITTINGS 0.34 jF�\P CHECKED K Y: BM UNDER CIVIL WORK DRAWING NO.: 4854 23 39 GATE VALVE 0 DETAIL 510 ENGR. CITY DATE MASTER VALVE (1-1/2") 1 FEBCO 860 W/650A STRAINER NETAFIM FILTER (1") 2.1 FLOW SENSOR, SIZE INDICATED DATA INDUSTRIAL IR -250B m REMOTE CONTROL VALVE (1-) 1.5 ■ EXISTING BACKFLOW PREVENTER , SIZE INDICATED N/A N/A 0 ELEVATION CHANGES 0 N/A EXISTING REMOTE CONTROL VALVE TO BE N/A N/A RELOCATED OR REMOVED AS CALLED OUT ON PLANS N EXISTING GATE VALVE, PIPE SIZE N/A TOTAL SYSTEM LOSSES 21.51 EXISTING IRRIGATION CONTROLLER N/A N/A TORO SENTINEL ASSEMBLY. CONTACT TOM RADEN PRESSURE NEEDED AT FARTHEST HEAD 30 © DETAIL 505 PRESSURE NEEDED AT P.O.0 51.51 m QUICK COUPLING VALVE HUNTER HQ-44LRC DETAIL 521 STATIC WATER PRESSURE 75-91 2" AND 2-1/2" USE PVC CLASS 315 SPECIFICATION ML 1-1/2" AND SMALLER USE PVC SC. 40 SET PRESSURE REDUCING VALVE AT 65 EXISTING SUPPLY LINE , SIZE INDICATED PVC PIPE NOTES: 1) MAIN LINE PIPE AND FITTINGS: 2-1/2" AND SMALLER USE SOLVENT WELD PIPE WITH PVC SCHEDULE 80 FITTINGS. TYPICAL. 2) LATERAL PIPE AND FITTINGS: USE SOLVENT WELD PIPE WITH PVC SCHEDULE 80 FITTINGS. TYPICAL. EXISTING TREES: WHERE IT IS NECESSARY TO EXCAVATE ADJACENT TO EXISTING TREES, USE ALL POSSIBLE CARE TO AVOID INJURY TO TREES AND TREE ROOTS. EXCAVATION IN AREAS WHERE 2 INCH AND LARGER ROOTS OCCUR SHALL BE DONE BY HAND. ROOTS 2 INCHES AND LARGER IN DIAMETER, SHALL BE TUNNELED UNDER AND SHALL BE HEAVILY WRAPPED IN BURLAP, TO PREVENT SCARRING OR EXCESSIVE DRYING. WHERE A DITCHING MACHINE IS RUN CLOSE TO TREES HAVING ROOTS SMALLER THAN 2 INCHES IN DIAMETER, THE WALL OF THE TRENCH ADJACENT TO THE TREE SHALL BE HAND TRIMMED, MAKING CLEAN CUTS THROUGH. ROOTS 1 INCH AND LARGER IN DIAMETER SHALL BE PAINTED WITH TWO COATS OF TREE SEAL, OR EQUAL. TRENCHES ADJACENT TO TREES WOULD BE CLOSED WITHIN 24 HOURS. WHERE THIS IS NOT POSSIBLE, THE SIDE OF THE TRENCH ADJACENT TO THE TREE SHALL BE KEPT SHADED WITH BURLAP OR CANVAS. IRRIGATION LEGEND GENERAL LEGEND SYM. DESCRIPTION MANUF. & PART NO. REFERENCE O REMOTE CONTROL VALVE , SIZE INDICATED SUPERIOR 950-DWPRS DETAIL 511 DETAIL NO. REMOTE CONTROL VALVE FOR DRIP , SIZE INDICATED SUPERIOR 950 -DW HUNTER 120 MESH DISK FILTER NETAFIM TECHFILTER SERIES N/A 30 N/A 2 0-6 GPM USE 3/4" NETAFIM TF075912-100 7-17 GPM USE 1" NETAFIM TF10912-200 DETAIL NO. 1 18-35 GPM USE 1-1/2" NETAFIM TF15L912-500 IN-LINE PRESSURE REGULATOR NETAFIM PRV SERIES 0-4 GPM USE 3/4" NETAFIM PRV075LF35V2K 5-17 GPM USE 3/4" NETAFIM PRV075HF35V2K DRAWN BY: AC' SM IRRIGATION N TES SCALE: N.T.S. 18-35 GPM USE 1-1/2" NETAFIM PRV15035V2K USE REDUCING BUSHING TO CONNECT EQUIPMENT OF DIFFERENT SIZES TOGETHER LF LINE FLUSHING VALVE - PVC PIPE CONNECTION NETAFIM TLSOV DETAIL NO. 4 DESIGNED BY: SM, EL LINE FLUSHING VALVE - PVC PIPE CONNECTION NETAFIM TLSOV DETAIL NO. 4 GATE VALVE, PIPE SIZE 2-1/2" AND SMALLER, NIBCO T-113 DETAIL 519 REV. IRRIGATION WATER METER , SIZE INDICATED N/A N/A jF�\P CHECKED K Y: BM UNDER CIVIL WORK DRAWING NO.: 4854 23 39 MASTER IRRIGATION VALVE, SIZE INDICATED WATTS 815-4SA-SS-NO-MO-T DETAIL 510 ENGR. CITY DATE BACKFLOW PREVENTER, SIZE INDICATED FEBCO 860 W/650A STRAINER DETAIL 507 FLOW SENSOR, SIZE INDICATED DATA INDUSTRIAL IR -250B m DETAIL 510 ■ EXISTING BACKFLOW PREVENTER , SIZE INDICATED N/A N/A 0 EXISTING WATER METER , SIZE INDICATED N/A N/A EXISTING REMOTE CONTROL VALVE TO BE N/A N/A RELOCATED OR REMOVED AS CALLED OUT ON PLANS N EXISTING GATE VALVE, PIPE SIZE N/A N/A EXISTING IRRIGATION CONTROLLER N/A N/A TORO SENTINEL ASSEMBLY. CONTACT TOM RADEN TORO MODEL NUMBER: © DETAIL 505 AQUA-FLO SUPPLY TEL. 661 273-5820 ESB48-U2-MPEA- 161 OK -0131 -VRA m QUICK COUPLING VALVE HUNTER HQ-44LRC DETAIL 521 PRESSURE SUPPLY LINE , SIZE INDICATED 2" AND 2-1/2" USE PVC CLASS 315 SPECIFICATION ML 1-1/2" AND SMALLER USE PVC SC. 40 SEX �Ex EXISTING SUPPLY LINE , SIZE INDICATED N/A N/A NON PRESSURE LINE , SIZE INDICATED PVC CLASS 200 SPECIFICATION DRIP IRRIGATION LINE WITH 12" O.C. EMITTERS NETAFIM TECHLINE CV TLDL6-12025 DETAIL NO. 5, 6 0.6 GPH, FOR TURF AREAS 7, 8, & 9 DRIP IRRIGATION LINE WITH 12" O.C. EMITTERS NETAFIM TECHLINE CV TLDL6-12025 DETAIL NO. 5, 6 0.6 GPH, FOR G.0 SHRUBS AREAS 7, 8, & 9 � ML -• DENOTE MAIN LINE SLEEVE, SIZE INDICATED PVC SC. 40 SPECIFICATION DENOTE LATERAL LINE SLEEVE, SIZE INDICATED PVC SC. 40 SPECIFICATION DENOTE SLEEVE FOR WIRES, SIZE INDICATED PVC SC. 40 SPECIFICATION CONTROLLER SEQUENCEA-1 GALLONS PER MINUTES 11 1" REMOTE CONTROL VALVE SIZE FLOW SENSOR NOTES: 1.FLOW SENSOR SHOULD BE INSTALLED IN-LINE, ONE AT DIAMETER OF SENSOR -SIZED PIPE UPSTREAM OF FLOW OF SENSOR -SIZED PIPE DOWNSTREAM, e.g., 2" SENSOR UPSTREAM AND 10" OF 2" PIPE DOWNSTREAM. 2.FLOW SENSOR SHOULD BE INSTALLED 10 PIPE DIAMETEF OF ANY VALVE, FITTING, METER OR BACKFLOW DEVICE. EACH POC, WITH 10 SENSOR AND 5 DIAMETER NEEDS 20" OF 2" PIPE UPSTREAM OR DOWNSTREAM 3.WIRES FROM FLOW SENSOR TO CONTROLLER SHOULD CONSIST OF ONE (1) BLACK AND ONE (1) RED STANDARD #14 IRRIGATION VALVE WIRES. 4.FLOW SENSOR SHALL BE HOUSED IN A VALVE BOX AND MARKED "FS" SPRINKLER HEADS SYM. DESCRIPTION MANUF. & PART N0. GPM RAD PSI ARC DETAIL NO. • BUBBLER BELOW GRADE HUNTER RZWS-18-50-CV 0.50 N/A 30 N/A 2 FONTANA CAMPUS PARKING LOT DRIP IRRIGATION NOTES: A. INSTALLATION 1. FOR TURF AREAS: INSTALL NETAFIM TECHLINE CV WITH 0.60 GPH EMITTERS 12" O.0 ALONG THE DRIP LATERAL. INSTALL DRIP LATERALS AT A DEPTH OF 6" AND AT A SPACING OF 12" BETWEEN LATERALS. MAXIMUM LENGTH OF TECHLINE LATERAL NOT TO EXCEED 300 LINEAR FEET. REFER TO CONSTRUCTION DETAILS FOR ADDITIONAL INFORMATION. 2. FOR GC/SHRUBS AREAS: INSTALL NETAFIM TECHLINE CV WITH 0.60 GPH EMITTERS 12" O.0 ALONG THE DRIP LATERAL. INSTALL DRIP LATERALS AT A DEPTH OF 4" AND AT A SPACING OF 18" BETWEEN LATERALS. MAXIMUM LENGTH OF TECHLINE LATERAL NOT TO EXCEED 300 LINEAR FEET. REFER TO CONSTRUCTION DETAILS FOR ADDITIONAL INFORMATION. 3. IRRIGATION SUBMAIN AND PIPE UNDER CONCRETE TO BE PVC CLASS 200. USE NETAFIM TECHLINE FITTINGS TO CONNECT PVC TO POLY TUBE 4. PREVENT KINKING OF TUBE. USE ELBOWS WHERE TIGHT BENDS ARE ENCOUNTERED. 5. "SNAKE" LATERALS ABOUT LANDSCAPE AREA SO AS TO ALLOW FOR EXPANSION AND CONTRACTION DUE TO TEMPERATURE VARIATIONS. 6. DO NOT USE DETERGENT OR LUBRICANTS IN POLYETHYLENE HOSE CONNECTIONS AS THEY MAY CAUSE ACCELERATED DETERIORATION OF THE HOSE. 7. MAKE ALL HOSE CUTS SQUARELY WITH A SHARP KNIFE OR SHEARS. 8. DIRT OR OTHER CONTAMINANTS SHOULD BE KEPT OUT OF EMISSION LINES BY PLACING TAPE OVER ENDS THAT ARE NOT IMMEDIATELY SECURED. 9. HAVE WATER RUNNING THROUGH LATERALS AT LOW PRESSURE (0-5 PSI) DURING FITTINGS CONNECTIONS 10. INSURE AREAS ABOUT WHICH LATERALS ARE BURIED ARE FREE OF SHARP STONES OR AGGREGATE MATERIALS. 11. BEFORE OPERATION, OPEN TUBING (LATERALS) END CAPS. TURN ON WATER AND ALLOW IT TO FLOW FREELY FOR SEVERAL MINUTES TO FLUSH LINES CLEAN. B. MAINTENANCE 1. CHECK/FLUSH LATERALS AT LEAST ONCE A MONTH. 2. CHECK/FLUSH FILTERS AT LEAST ONCE A WEEK. 3. CHECK/FLUSH EMITTERS, WHERE REQUIRED. 4. CLEAR WEED GROWTH FROM AROUND EMITTER AREAS. 5. CHECK CONTROLLER PROGRAM FOR CORRECT OPERATION. ADJUST WHEN NECESSARY TO ACCOMMODATE CLIMATIC VARIATION. DATE SUBMITTAL TRACKER Q RD C= DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER THE ' CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH ��� 5P� ��`� P��� E M� -9� ?� rn �� ATURE n 9/30/11 y EXP. DATE ��9TF OF CA�� CITY OF FONTANA, CALIFORNIA 10-23-09 FIRST PLAN CHECK SUBMITTAL FONTANA CAMPUS PARKING LOT DRAWN BY: AC' SM IRRIGATION N TES SCALE: N.T.S. DESIGNED BY: SM, EL DATE: 10-23-09 REV. jF�\P CHECKED K Y: BM APP /p,?p,�� DATE: DRAWING NO.: 4854 23 39 REVISION DESCRIPTION DATE ENGR. CITY DATE