HomeMy WebLinkAbout2998-23STAGE 4 - SHEET 23 - SCOPE OF WORK I. KEEP IN PLACE THE TRAFFIC CONTROL AND DETOUR SIGNING PER STAGE 2. REMOVE ANY EXISTING CONFLICTING STRIPING AND INSTALL TEMPORARY 3. INSTALL MEDIANS PER STREET IMPROVEMENT PLANS. A. INSTALL AC PAVING. 5. INSTALL STRIPING AND PAVEMENT MARKINGS PER PROPOSED SIGNING ANI ON SIERRA AVENUE FROM 90+00 STA. T0- STA. 109+00 pari T im TRAFFIC.CONTROL ON THESE PLANS ARE FOR CONCEPT ONLY, LANE LOCATIONS MAY HAVE TO BE MODIFIED PER CONTRACTORS SCHEDULE AND CONSTRUCTION METHODS. CONTRACTOR SHALL SUBMIT DETAILED TRAFFIC CONTROL PLANS FOR APPROVAL OF THE CITY TRAFFIC ENGINEER TEN(10) WORKING DAYS IN ADVANCE OF ANY PROPOSED MODIFICATION OF THESE PLANS OR CONSTRUCTION STAGING. I. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE' ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY. CALL (909) 350-7610 3. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. C18a W 13. TRAFFIC SIGNS DIMENSIONS, COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATION SHEET. SIGN CODES SHOWN HEREON ARE TO CONFORM TO Z CAL TRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. 14. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 139. V 15. ALL FLASHING YELLOW WARNING LIGHTS SHALL BE TYPE 'A' PORTABLE, LENS DIRECTED. ~ ENCLOSED AND MOUNTED AT A MINIMUM HEIGHT OF THREE FEET, MEASURED FROM THE CQ BOTTOM OF THE LENS TO THE UNDERLYING SURFACE. G 16. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 17. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL REMOVE TRAFFIC CONTROL DEVICES LEGEND TO THE SATISFACTION OF THE CITY. TRAFFIC ENGINEER, ANS INSTALL SIGNING AND STRIPING PER THE SIGNING AND STRIPING PLAN. ® FLASHING ARROW BOARD 18. CONTRACTOR TO CONTACT T I M RASTEDT AT (909) 350-6649 TWO WORKING DAYS • DELINEATOR PRIOR TO ANY SIGN INSTALLATION TO ALLOW CITY STAFF TO LOCATE EXISTING UNDERGROUND FACILITIES. ++ TYPE II BARRICADE -EH- TYPE III BARRICADE -�-{ FLAG TREE LANE CLOSURE 0 PERMIT NO.08-03-N-MC-0483 REV. REVISION DESCRIPTION DATE ENGR. CITY DATE PLANS PREPARED BY: CITYOF FONTANA. WORK AREA A D CALTRANS CHAN��'ST. �uA� u,irs .���3 SHOULD CONSTRUCTION OF THE REQUIRED PROFEss,�,7­ IMPROVEMENTS NOT COMMENCE WITHIN TWO ,, - F W WILLDANDIRECTION OF TRAFFIC Flow _ I1 #2�,.�.��-��,A._P._A �.,M .�. - . .. . .. .. .-- WORK ZONE TRAFFIC CONTROL PLA K -RAIL TEMPORARY CRASH CUSHION PER CALTRANS STD PLAN (2002) TIA-ARRAY TUTA C20(LTI C18 1041 6 L.L Li Q ry LLJ z 0 N 0 Q ry L -i m A. THE CONTRACTOR SHALL NOTIFY THE CITY TRAFFIC SECTION TWO WORKING DAYS PRIOR TO SIERRA AVO IMPLEMENTING THE TRAFFIC CONTROL PLAN TO ALLOW CITY STAFF TIME TO ADJUST TRAFFIC SIGNAL DETECTION. SCALE 1" 40' 550 TAPER 250 TAPER N 5. THE CONTRACTOR SHALL MAINTAIN TWO WAY TRAFFIC AT ALL TIMES UNLESS OTHERWISE N APPROVED BY THE CITY TRAFFIC ENGINEER. QUALIFIED FLAGGERS SHALL BE USED WHEN THE ROADWAY IS REDUCED TO A SINGLE LANE OR WHERE TRAFFIC MUST STOP FOR 4" SOLID YELLOW(TEMP) I C30 2 MOVEMENT OF EQUIPMENT. C30 2 C30 2 C30 2 ]jl W C13 2 C30 2 C30 2 C30 2 W 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES. DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. V) 7. THE WORK ZONE SHALL BE ROUTINELY INSPECTED AND MAINTAINED TO ENSURE PROPER "' � � � VISIBILITY AND OPERATION OF ALL TRAFFIC CONTROL AND ADVANCED TRAFFIC CONTROL DEVICES. ull W 8. ALL EXISTING OR TEMPORARY SIGNS. STRIPING OR PAVEMENT MARKINGS THAT ARE IN CONFLICT ° �� W AND/OR NO LONGER APPLICABLE SHALL BE REMOVED. 40 ' (T Y P) 9. SIGNS SHALL NOT BE PLACED IN EXCESS OF 15 FEET FROM THE EDGE OF THE TRAVELED WAY. PORTABLE SIGN STANDARDS SHALL BE TIED DOWN OR WEIGHTED. TO PREVENT o Lo_ TOPPLING. _ _ _ 10. THE EXACT LOCATION OF ALL TRAFFIC CONTROL DEVICES IS SUBJECT TO APPROVAL OF + 00 THE CITY TRAFFIC ENGINEER, ADDITIONAL WARNING, CONSTRUCTION SIGNS OR TRAFFIC pq _ �Q 00 SAFETY EQUIPMENT MAY BE REQUIRED BY THE CITY TRAFFIC ENGINEER. II. ALL WORK AREAS SHALL BE CLEARLY IDENTIFIED AND DELINEATED WITH CONES. PORTABLE a _ Q DELINEATORS AND/OR BARRICADES. ALL CONES SHALL BE A MINIMUM OF 28 INCHES IN HEIGHT. ALL DELINEATORS SHALL BE A MINIMUM OF 36 INCHES IN HEIGHT. l� (n 12. ALL SIGNS SHALL BE REFLECTORIZED OR ILLUMINATED. C18a W 13. TRAFFIC SIGNS DIMENSIONS, COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATION SHEET. SIGN CODES SHOWN HEREON ARE TO CONFORM TO Z CAL TRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. 14. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 139. V 15. ALL FLASHING YELLOW WARNING LIGHTS SHALL BE TYPE 'A' PORTABLE, LENS DIRECTED. ~ ENCLOSED AND MOUNTED AT A MINIMUM HEIGHT OF THREE FEET, MEASURED FROM THE CQ BOTTOM OF THE LENS TO THE UNDERLYING SURFACE. G 16. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 17. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL REMOVE TRAFFIC CONTROL DEVICES LEGEND TO THE SATISFACTION OF THE CITY. TRAFFIC ENGINEER, ANS INSTALL SIGNING AND STRIPING PER THE SIGNING AND STRIPING PLAN. ® FLASHING ARROW BOARD 18. CONTRACTOR TO CONTACT T I M RASTEDT AT (909) 350-6649 TWO WORKING DAYS • DELINEATOR PRIOR TO ANY SIGN INSTALLATION TO ALLOW CITY STAFF TO LOCATE EXISTING UNDERGROUND FACILITIES. ++ TYPE II BARRICADE -EH- TYPE III BARRICADE -�-{ FLAG TREE LANE CLOSURE 0 PERMIT NO.08-03-N-MC-0483 REV. REVISION DESCRIPTION DATE ENGR. CITY DATE PLANS PREPARED BY: CITYOF FONTANA. WORK AREA A D CALTRANS CHAN��'ST. �uA� u,irs .���3 SHOULD CONSTRUCTION OF THE REQUIRED PROFEss,�,7­ IMPROVEMENTS NOT COMMENCE WITHIN TWO ,, - F W WILLDANDIRECTION OF TRAFFIC Flow _ I1 #2�,.�.��-��,A._P._A �.,M .�. - . .. . .. .. .-- WORK ZONE TRAFFIC CONTROL PLA K -RAIL TEMPORARY CRASH CUSHION PER CALTRANS STD PLAN (2002) TIA-ARRAY TUTA C20(LTI C18 1041 6 L.L Li Q ry LLJ z 0 N 0 Q ry L -i m