Loading...
HomeMy WebLinkAbout2998-21STAGE 4 - SHEET 21 - SCOPE OF WORK I. KEEP IN PLACE'THE TRAFFIC CONTROL AND DETOUR SIGNING PER STAGE 3 - SHEET 17. 2. REMOVE ANY EXISTING CONFLICTING STRIPING AND INSTALL TEMPORARY STRIPING. 3. INSTALL MEDIANS PER STREET IMPROVEMENT PLANS. 4. INSTALL AC PAVING. 5. INSTALL STRIPING AND PAVEMENT MARKINGS PER PROPOSED SIGNING AND STRIPING PLAN ON CITRUS AVENUE FROM STA.88+78 TO STA.104+00 C30 lfl—\ CITRUS NOTE TRAFFIC CONTROL ON THESE PLANS ARE FOR CONCEPT ONLY, LANE LOCATIONS MAY HAVE TO BE MODIFIED PEER .CO.NTRACTORS SCHEDULE AND CONSTRUCTION METHODS. CONTRACTOR SHALL SUBMIT DETAILED TRAFFIC CONTROL PLANS FOR APPROVAL ' OF THE CITY TRAFFIC ENGINEER TEN(10) WORKING DAYS IN ADVANCE OF ANY PROPOSED MODIFICATION OF THESE PLANS OR CONSTRUCTION STAGING. r(DETAIL 3��TRUS ( AV* i I CONSTRUCTION TRAFFIC CONTROL PLAN INSTALLATION NOTES Fl PAINT STRIPING, MARKING, OR LEGEND AS NOTED. F2] PLACE SIGN AS NOTED. AV. I1TYPE IV(L)ARROW (TEMP) rn C30 O ' �--- xxCN X X O p _ Ljj W = zV) = W U V) —> 40' (TY, Ll Q r �x x x x x x x SCALE: 1" 40' o D DIAL TWO WORKIN BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-Zo00 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALE X 21 C30 C30 1 2 £f- f m w cZ 4 _... ( T REV. REVISION DESCRIPTION DATE ENGR. CITY DATE I CAL TRANSI CM16ES . DuAL vy1rs - L • /f-03 TYPE III BARRICADE —� DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. eeC 0, eZ > Z: >, 8 4 W11 tle. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR WORK AREA trA� -.;Ce J (909) 350-7610 3. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PLANS PREPARED BY: PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, N 0 LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. W WILLDAN 4. THE CONTRACTOR SHALL NOTIFY THE CITY TRAFFIC SECTION TWO WORKING DAYS PRIOR TO �-- IMPLEMENTING THE TRAFFIC CONTROL PLAN TO ALLOW CITY STAFF TIME TO ADJUST W S/ �2� TRAFFIC SIGNAL DETECTION. W PLAN L.L 5. THE CONTRACTOR SHALL MAINTAIN TWO WAY TRAFFIC AT ALL TIMES UNLESS OTHERWISE Q APPROVED BY THE CITY TRAFFIC ENGINEER. QUALIFIED FLAGGERS SHALL BE USED WHEN ' 16' 16'1 4.4m 4.em 21 C30 1 a6.ro m 350' TAPER CITY OF FONTANA GENERAL NOTES f 0b.G m 16&. b m 350' 350' 2 C30 L_J t� i SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. C20 (LT) C18 I. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE FLASHING ARROW BOARD • ONE WEEK PRIOR TO IMPLEMENTING DETOURS. i+ 2. CONSTRUCTION PERMITS.SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY TYPE III BARRICADE —� DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. LANE CLOSURE INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR WORK AREA m-0- TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY. CALL J (909) 350-7610 3. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PLANS PREPARED BY: PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, N 0 LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. W WILLDAN 4. THE CONTRACTOR SHALL NOTIFY THE CITY TRAFFIC SECTION TWO WORKING DAYS PRIOR TO �-- IMPLEMENTING THE TRAFFIC CONTROL PLAN TO ALLOW CITY STAFF TIME TO ADJUST W S/ �2� TRAFFIC SIGNAL DETECTION. W PLAN L.L 5. THE CONTRACTOR SHALL MAINTAIN TWO WAY TRAFFIC AT ALL TIMES UNLESS OTHERWISE Q APPROVED BY THE CITY TRAFFIC ENGINEER. QUALIFIED FLAGGERS SHALL BE USED WHEN Industry, CA 91746-3497 DRAWN BY: THE ROADWAY IS REDUCED TO A SINGLE LANE OR WHERE TRAFFIC MUST STOP FOR scal.E: MOVEMENT OF EQUIPMENT. W = No. 45729 (562) 908-6200 (�J 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, - () 00 DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. UNDER THE S ER SION OF: T. THE WORK ZONE SHALL BE ROUTINELY INSPECTED AND MAINTAINED TO ENSURE PROPER O DATE 4. 14.03 VISIBILITY AND OPERATION OF ALL TRAFFIC CONTROL AND ADVANCED TRAFFIC CONTROL DEVICES. qTF �F A F\P Q0 4% *.� 113.C.E. 8. ALL EXISTING OR TEMPORARY SIGNS, STRIPING OR PAVEMENT MARKINGS THAT ARE IN CONFLICT + 00 CHECKED BY: AND/OR NO LONGER APPLICABLE SHALL BE REMOVED. 9. SIGNS SHALL NOT BE PLACED IN EXCESS OF 15 FEET FROM THE EDGE OF THE TRAVELED HERBERT L. GLUESING JR. 45729 WAY. PORTABLE SIGN STANDARDS SHALL BE TIED DOWN OR WEIGHTED TO PREVENT Q TOPPLING. �--- 10. THE EXACT LOCATION OF ALL TRAFFIC CONTROL DEVICES IS SUBJECT TO APPROVAL OF THE CITY TRAFFIC ENGINEER, ADDITIONAL WARNING, CONSTRUCTION SIGNS OR TRAFFIC SAFETY EQUIPMENT MAY BE REQUIRED BY THE CITY TRAFFIC ENGINEER. W II. ALL WORK AREAS SHALL BE CLEARLY IDENTIFIED AND DELINEATED WITH CONES. PORTABLE Z DELINEATORS AND/OR BARRICADES. ALL CONES SHALL BE A MINIMUM OF 28 INCHES IN HEIGHT. ALL DELINEATORS SHALL BE A MINIMUM OF 36 INCHES IN HEIGHT. 12. ALL SIGNS SHALL BE REFLECTORIZED OR ILLUMINATED. 13. TRAFFIC SIGNS DIMENSIONS, COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS U SIGN SPECIFICATION SHEET. SIGN CODES SHOWN HEREON ARE TO CONFORM TO I-- CAL TRANS SPECIFICATION SHEET CODES. TRAFFIC SIGN SIZE SHALL BE STANDARD UNLESS OTHERWISE SHOWN ON THE PLANS. CQ G 14. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANSo PER CITY STANDARD DETAIL 139. 15. ALL FLASHING YELLOW WARNING LIGHTS SHALL BE TYPE 'A' PORTABLE, LENS DIRECTED, ENCLOSED AND MOUNTED AT A MINIMUM HEIGHT OF THREE FEET, MEASURED FROM THE BOTTOM OF THE LENS TO THE UNDERLYING SURFACE. 16. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 17. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL REMOVE TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER, ANS INSTALL SIGNING AND STRIPING PER THE SIGNING AND STRIPING PLAN. 18. CONTRACTOR TO CONTACT TIM RASTEDT AT (909) 350-6649 TWO WORKING DAYS PRIOR TO ANY SIGN INSTALLATION TO ALLOW CITY STAFF TO LOCATE EXISTING UNDERGROUND FACILITIES. f 0b.G m 16&. b m 350' 350' 2 C30 L_J t� i SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. C20 (LT) C18 \■ =1 W 7 L w —I 0 z 0 U U L.L Q W z 0 N rK 0 W z L -i Q Cf) U z K -RAIL 0 TEMPORARY CRASH CUSHION PER CALTRANS — STD PLAN (2002) TIA-ARRAY TUTA N M (\j N O NN a' LEGEND M FLASHING ARROW BOARD • DELINEATOR i+ TYPE II BARRICADE i1F TYPE III BARRICADE —� FLAG TREE LANE CLOSURE V) WORK AREA m-0- DIRECTION OF TRAFFIC FLOW \■ =1 W 7 L w —I 0 z 0 U U L.L Q W z 0 N rK 0 W z L -i Q Cf) U z K -RAIL 0 TEMPORARY CRASH CUSHION PER CALTRANS — STD PLAN (2002) TIA-ARRAY TUTA N M (\j N O NN a' W t7 a V) PERMIT NO, 08 -03=N -MC -0483 J z PLANS PREPARED BY: CITY OF F O N T A N A 0 pFESS� GLUE� W WILLDAN S/ �2� WORK ZONE TRAFFIC CONTROL PLAN L.L 13191 Crossroads Parkway North, Suite 405 Q Industry, CA 91746-3497 DRAWN BY: STAGE 4 scal.E: = No. 45729 (562) 908-6200 LT CITRUS AVENUE I' =40' 00 Exp. 12-31-06 * UNDER THE S ER SION OF: DESIGNED BY: JMD STA 88+50 TO STA 190+00 DATE 4. 14.03 `n rn qTF �F A F\P Q0 4% *.� 113.C.E. _ z N. CHECKED BY: APPROVED BY: — �� DRAWING NO.: 2 '� HERBERT L. GLUESING JR. 45729 H L GN. 2 99 8 4 0 CITY TRAFFIC FISIGINIFF0 R.T.E. 1931 DATE: