HomeMy WebLinkAbout4070-50
SAN BERNARDINO COUNTY
B.M. OF 627, NAVD 88
ELEVATION: 1011.70 FEET
IRRIGATION EQUIPMENT LEGEND
SYMBOL DESCRIPTION MANUFACTURER
MODEL NUMBER
NOTES
ENGR.
CITY
DATE
(METER) POINT OF CONNECTION
BY OTHERS
BY OTHERS
FLOW METER
DATA INDUSTRIES
FLOW SENSOR
LINE SIZE
MASTER VALVE
WATTS
815-4SA-BG-NC-MO
LINE SIZE
RDCD PRSSRE. BCKFLW. PRVNTR.
FEBCO
825Y- W/ LEMEUR ENCLOSURE
LOCATE IN SHRUB AREAS. Provide press. reg. set of 85psi.
AUTOMATIC VALVE
SUPERIOR
950DW BRASS
SIZE AS NOTED ON PLANS
QUICK COUPLER
RAINBIRD
33DLRC
GATE VALVE
NIBCO OR EQUAL
LINE SIZE
AUTOMATIC CONTROLLER
TORO - SENTINEL
ESBXX-U2MPEA161OK-081-VRA
W/STRONG BOX ENCLOSURE,
SEE DETAILS
EX. RAIN TIP BUCKET
PROVIDED BY OTHERS Refer to City of Fontana
remote location, provide wiring
MAINLINE
2" OR LARGER CL 315
1 1/2" OR SMALLER SCH 40
REFER TO PLAN
SCH. 40 PVC LATERAL LINE
SIZE PER PLANS
BOOSTER PUMP
BARRETT PUMPS
IBGA6-3-2-2
Contact: Green Product Soles (949) 584-•7311
SHC40 CONTROL WIRE CONDUIT
N/A
N/A
N/A
IRRIGATION HEAD LEGEND
SYMBOL DESCRIPTION
MANUFACTURER
MODEL NUMBER
G.P.M. P.S.I.
RADIUS
1
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, QUARTER HEAD
.24
30
B.
2
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, HALF HEAD
.50
30
8'
3
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, TQ HEAD
.76
30
B.
4
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, FULL HEAD
1.00
30
B.
5
SHRUB POP-UP SPRAY HEAD
TORO
5705-12P-PRX-COM, QUARTER HEAD
.40
30
10'
g
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, HALF HEAD
.71
30
10'
7
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, T.Q.
.97
30
10'
$
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX- COM, FULL HEAD
1.49
30
10'
9
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, QUARTER HEAD
.50
30
12'
0
SHRUB POP-UP SPRAY HEAD
TORO
5705-12P-PRX-COM HALF HEAD
1.09
30
12'
11
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, T.Q.
1.55
30
12'
2
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM,FULL HEAD
2.19
30
12'
3
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, QUARTER HEAD
.85
30
15'
14
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, HALF HEAD
1.65
30
15'
45)
SHRUB POP-UP SPRAY HEAD
TORO
570S-12P-PRX-COM, T.Q. HEAD
2.60
30
15'
6
SHRUB POP-UP SPRAY HEAD
TORO
571S-12P-PRX-COM, FULL HEAD
3.60
30
15'
7
SHRUB POP-UP ROTOR HEAD
HUNTER
PGP-ADJ-360-01
.5
30
28'
$
SHRUB POP-UP ROTOR HEAD
HUNTER
PGP-ADJ-360-04
1.2
30
32'
SHRUB POP-UP BUBBLER HEAD
TORO
570S-12P-PRX-COM-SB-4-180-PC2
.46
30
2.5'
LANDSCAPE CONTRACTOR AS A NORMAL SCOPE OF WORK TO ADJUST
SYSTEMS AND HEADS, USING:
(PRS) PRESSURE REGULATING RISER
COM) CHECK-O-MATIC SEAL
VAN) VARIABLE ARC NOZZLES
X -FLOW SHUT-OFF DEVICES
(MPR) MATCHED PRECIPITATION RATE NOZZLES
TO FACILITATE AN EFFICIENT WATER IRRIGATION SYSTEMS.
LANDSCAPE CONTRACTOR TO PLACE SPRINKLER HEADS ADJACENT TO
GLASS AREAS, AND WALLS, A MINIMUM OF 12" AWAY FROM SAID AREAS.
IRRIGATION PLANS ARE SCHEMATIC AND ARE DRAWN FOR EASE IN
READING, AND CLARIFICATION ONLY. ALL HEADS, VALVES, LATERAL
LINES, AND MAINLINES, AS WELL AS ANY OTHER IRRIGATION EQUIPMENT
SHALL BE INSTALLED IN PLANTED AREAS.
INDICATES STATION NUMBER & CONTROLLER
/A-1\12.00 INDICATES GALLONS PER MINUTE OR HOUR
INDICATES AUTOMATIC VALVE SIZE
-------------
;;•
TOLL FREE 1 -800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
f,
r�
ENGR.
CITY
DATE
10
PLANTING AND IRRIGATION REVISION
8/12/08
REV.
REVISION DESCRIP11ON
DATE
ENGR.
CITY
DATE
10
PLANTING AND IRRIGATION REVISION
8/12/08
B-5\16. 0
1"
f
i
f
i
f
i
t .
i
3/4,1 i
i
WOODS PLACE
{
6.6
................... v J.... ............................�...... _.........
1 - _ 1. .............. .........
„ �,
... . ....... . .......
= 3 7 5
1 � �
/A -l\11.7
0.
1
2"
_...�n. + ................I............
.
r � Vt
3/411
i t 3/4n
' 3/4" ! cc I
3/4"\
1
13/411/
t
PAD=89.9
4 f
`2�� / 3
8 L
A-2 27.7
3/,4
8 � i
ef
f PAD=92.3i
A - 3
32.7 t ,
1"
\ 3/4"
V
TCH LINE'C'SEE SHEET 04
KB HOME Greater Los Angeles
Inland Valley Division
36310 Inland Valley Drive
Wildomar CA 92595
40'
10'
1 "= 20' 1 20'
1 1
KEY MAP N.T.S.
,-,.v CITY OF FONTANA, CALIFORNIA
I"DxRIGATION PLAN
oM TRACT 17027SCALE:
1 31=
COMM uNir FACILITIES. -7 �r��r
�08.12.2008
APPROVED FOR CONSTRUCTION
--
DATE: - IL-tu i v 2C
PLOT DATE: 09.29.2008