HomeMy WebLinkAbout4282-1PRIVATE ENGINEER'S NOTE:
THE EXISTENCE AND APPROXIMATE LOCATION OF ANY UNDERGROUND
UTILITIES OR SUBSTRUCTURES SHOWN ON THESE PLANS ARE OBTAINED
BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE,
THERE ARE NO EXISTING UTILITIES OR STRUCTURES EXCEPT AS SHOWN
ON THESE PLANS. THE ENGINEER ASSUMES NO LIABILITY AS TO THE
EXACT LOCATION OF SAID LINES NOR FOR UTILITIES OR IRRIGATION LINES
WHOSE LOCATIONS ARE NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR NOTIFYING ALL UTILITY AND IRRIGATION COMPANIES PRIOR TO WORK
ON EXCAVATION TO DETERMINE EXACT LOCATION OF ALL LINES AFFECTING
THIS WORK, WHETHER OR NOT SHOWN HERON, AND FOR ANY DAMAGE
OR PROTECTION OF THESE LINES.
NOTICE TO CONTRACTORS:
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY
ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED
TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING
THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD
DESIGN PROFESSIONAL HARMLESS FROM= ANY AND ALL LIABILITY, REAL OR ALLEGED,
IN CONNECTION WITH THE PERFORMANCE OF THE WORK OF THIS PROJECT,
EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL.
SURVEY MONUMENT NOTE:
SURVEY MONUMENTS THAT EXIST AS SHOWN ON RECORDED MAPS, HIGHWAY MAPS
OR POINTS THAT PROVIDE SURVEY CONTROL WITHIN THE CONSTRUCTION AREA, SHALL
BE LOCATED AND REFERENCED OUT BY A LICENSED LAND SURVEYOR OR REGISTERED
CIVIL ENGINEER (AUTHORIZED TO PRACTICE LAND SURVEYING), AND CORNER RECORDS
SHALL BE FILED WITH THE COUNTY SURVEYOR PRIOR TO THE START OF CONSTRUCTION.
THESE CORNER RECORDS SHALL DESCRIBE THE MONUMENTS FOUND WITH TIE DISTANCES
TO REFERENCE POINTS FOR RESETTING OF THE SURVEY MONUMENTS. WHEN
CONSTRUCTION IS COMPLETED, MONUMENTS SHALL BE SET AND CORNER RECORDS
SHALL BE FILED WITH THE COUNTY SURVEYOR SHOWING THE NEW MONUMENTS.
CONTRACTOR'S RESPONSIBILITY FOR SAFETY:
IN SUBMITTING A BID FOR THIS WORK THE CONTRACTOR AGREES THAT- HE SHALL
ASSUME SOLE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS
REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING
HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE
OWNERS AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR
ALLEGED IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FROM SOLE NEGLIGENCE OF THE OWNER OR ENGINEER.
CITY OF FONTANA. UTILITY NOTIFICATION LIST:
CITY OF FONTANA
SO. CALIF. EDISON
8353 SIERRA AVENUE
ATTN: CHRIS LORIMER
FONTANA, CA 92335
7951 REDWOOD AVENUE
(909) 350-6632
FONTANA, CA 92336
3.
(909) 357-6221
UNDERGROUND SERVICE ALERT
11+48± TO STA. 15+71.97
(800) 227-2600
SPRINT
STA.
ATTN: LYNN DURRETT
SO. CALIF. GAS COMPANY
2592 DUPONT DR
1981 W. LUGONIA AVENUE
IRVINE, CA 92612
REDLANDS, CA 92374
(800) 659-9698
(909) 335-7871
55+00.00 TO STA. 65+00.00
EMERGENCIES: (800) 427-2200
ADELPHIA
STA.
1205 DUPONT STREET
FONTANA WATER COMPANY
ONTARIO, CA 91761
ATTN: LUIS MONTENEGRO
(909) 390-4738
11142 GARVEY AVE.
PROPOSED MANHOLE
EL MONTE, CA 91733
VERIZON
(626) 448-6183
ATTN: TANYA SAINS
EA
1400 E. PHILLIPS BLVD.
CUCAMONGA VALLEY WATER DIST.
ONTARIO, CA 91766
ATTN: MARTY ZUIRBUUS
(909) 469-6369
10440 ASHFORD ST.
E -ELECTRIC; TV -CABLE TELEVISION; IR-IRRIGA11ON
RANCHO CUCAMONGA, CA 91729
SBC/PAC BELL
(909) 987-2591
ATTN: SUSAN MORGAN
EA
1265 N. VAN BUREN ST. #180
INLAND EMPIRE UTILITY AGENCY
ANAHEIM, CA 92807
ATTN: MIR FATTAHI
(714) 666-7401
P.O. BOX 9020
1
CHINO HILLS, CA 91709
(909) 993-1502
BASIS OF BEARING:
CENTERLINE OF FOOTHILL BOULEVARD BETWEEN CHERRY AVENUE AND
HEMLOCK AVENUE BEING N89'48'09"W PER RECORD OF SURVEY, RECORDED
IN BOOK 59, PAGES 52 THROUGH 62, RECORDS OF SAN BERNARDINO
COUNTY.
BENCH MARK NO. 368
LOCATION:
CHISELED "X" NORTHEAST CORNER OF
ABUTMENT AT FOOTHILL BOULEVARD AND
EAST AVENUE.
ELEV. 1195.52'
Underaround Service Alert
SECTION, 4216/4217 OF THE GOVERNMENT
Y CODE REQUIRES A DIG ALERT IDENTIFICATION
NUMBER BE ISSUED BEFORE A PERMIT TO
EXCAVATE WILL BE VAUD
FOR YOUR DIG ALERT I.D. NUMBER CALL
UNDERGROUND SERVICE ALERT
TOLL FREE 1-800-227-2600
TWO WORKING DAYS BEFORE YOU DIG REV. REVISION DESCRIPTION
TKE JOB #: 101-18
EAST AVE SHEET NO. 3
ILEX ST.
DATE I ENGR. I CITY I DATE
ESSI
No.69984
Exp -9-30-08
9� CIV1v
CAL��
CITY OF FONTANA
FOOTHILL BOULEVARD
SEWER IMPROVEMENT PLANS
PHASE I
SHEET NO. 4
COTTONWOOD AVE.
SHEET NO. 5 SHEET NO. 6
MULBERRY AVE.
FOOTHILL
INDEX MAPS
SCALE: 1"=400'
INDEX SHEETS:
1.
TITLE SHEET
QUANTITIES: --
01
2.
GENERAL NOTES
LF
3.
PLAN/PROFILE
STA.
11+48± TO STA. 15+71.97
4.
PLAN/PROFILE
STA.
25+18.39 TO STA. 31+12±
5.
PLAN/PROFILE
STA.
45+27f TO STA. 55+00.00
6.
.*
PLAN/PROFILE
STA.
55+00.00 TO STA. 65+00.00
7.
PLAN/PROFILE
STA.
65+00.00 TO STA. 71+81.47
8.
PLAN/PROFILE
STA.
75+02f TO STA. 80+61.93
TKE ENGINEERING, INC.
4446 CENTRAL AVENUE
RIVERSIDE, CA 92506
(951) 680-0440
10(=MERING FAX (9 1) 680-0490
RY�M. RENNER R.C.E. No. 69984
EXPIRES: 9-30-08
BOULEVARD
PLAN/PROFILE
SEWER IMPROVEMENTS
FOOTHILL BOULEVARD
EAST AVENUE TO CHERRY AVENUE
AVE.
SHEET NO. 7 SHEET NO. 8
ALMOND AVE.
PROJECT
LOCATION
. J
LEGEND
CONSTRUCTION NOTES:
QUANTITIES: --
01
CONSTRUCT 8" EXTRA STRENGTH V.C.P. SEWER INCLUDING PCC PAVEMENT.
.4303
LF
REMOVAL. CONSTRUCT TRENCH REPAIR PER CITY OF FONTANA STD. DETAIL
EXISTING POWER POLE
MB 0
EXISTING MAILBOX
NO. 1008.
EXISTING WATER METER
-�-
O2
CONSTRUCT 4' MANHOLE PER CITY OF FONTANA STANDARD PLAN NO. 2001..
21
EA
O3
CONSTRUCT 6" EXTRA STRENGTH SEWER LATERAL WITH PLUG INCLUDING PCC.
35
EA
PAVEMENT REMOVAL, PER CITY OF FONTANA STANDARD PLAN NO.9S 2005,
EXISTING MANHOLE
®
EXISTING SURVEY CONTROL
20069 AND 2007. CONSTRUCT TRENCH REPAIR PER CITY OF FONTANA STD.
EXISTING RIGHT-OF-WAY
PROPOSED SEWER
DETAIL NO. 1008.
PROPOSED MANHOLE
O4
CONSTRUCT 6' MANHOLE PER CITY OF FONTANA STANDARD PLAN NO. 2001.
1
EA
O5
REMOVE PORTIONS OF EXISTING SEWER PIPE AND CASING AS REQUIRED TO.
2
EA
_
CONSTRUCT MANHOLE AND CONNECT TO EXISTING SEWER.
E -ELECTRIC; TV -CABLE TELEVISION; IR-IRRIGA11ON
60
CONNECT PROPOSED MANHOLE TO EXISTING SEWER PIPE. REMOVE SEWER
1
EA
PLUG AS REQUIRED TO MAKE CONNECTION.
70
CONSTRUCT 8" MECHANICAL JOINT SEWER PLUG..
1
EA
SHEET NO. 7 SHEET NO. 8
ALMOND AVE.
PROJECT
LOCATION
. J
LEGEND
/SYMBOLS:
EXISTING FIRE HYDRANT
®
EXISTING WATER VALVE
PPP
EXISTING POWER POLE
MB 0
EXISTING MAILBOX
WM 0
EXISTING WATER METER
-�-
EXISTING EDGE OF PAVEMENT
EXISTING TREE
O
EXISTING SHRUB
°---4
EXISTING STR ET LIGHT
H
OM
EXISTING MANHOLE
®
EXISTING SURVEY CONTROL
R/W
EXISTING RIGHT-OF-WAY
PROPOSED SEWER
0
PROPOSED MANHOLE
PROPOSED LATERAL
OU
UTILITY INTERFERENCE FLAG (APPROXIMATE
LOCATION OF INTERFERENCE WITH TYPE OF
UTILITY INDICATED BY: W -WATER; G -GAS;
T -TELEPHONE; SD -STORM DRAIN; S -SEWER;
E -ELECTRIC; TV -CABLE TELEVISION; IR-IRRIGA11ON
U -UNKNOWN UTILITY).
QIL BASELINEI BLVD. Q
FOOTHILL BLVD.
Q }
z ir c
3 = w Ir
W U U
ARROW RTE. C
SAN BERNARDINO l AVE. IE
VALLEY 11 BLVD. IE
F1Q-F7iYVY . _;
� E -*C DFtAWNG� VICINITY MAP!
N:T.S.'
sHouLo coNsrnucnoN of THE CITY OF FONTANA, CALIFORNIA
coMMEr4icE vDTi-MwRiwoMYaT,Rs"oF THE SEWER IMPROVEMENT PLANS
DAIS OF APPROVAL SHOWN HEREON FAVM FOOTHILL BOULEVARD �'AND CARRIED FORTH IN A DILIGENTSl►L AS SHO11N
MANNER, THE CIN ENGINEER MAY er: TITLE SHEETpA�REQUIRE REVISIONS TO THE PLANS TOTUB PHASE I JUNE 2007
BRING THEM INTO CONFORMANCE WITH q{EG(m BY: APPROVED BY: ATE*.ow►WNc No.:
CONDITIONS AND STANDARDS IN EFFECT. � S/07- I
0 1
IIY ENGINEER R.C.E No. 44+M4282 8
&88l9