Loading...
HomeMy WebLinkAbout4877-110 N 0 C:) I 0 0 (A CD N C) DATE 9/7/10 JOB # OS -019 -D z ON MOUNTING BRACKETS INSIDE APPROVED VANDAL RESISTANT APPROVED PROTECTIVE ENCLOSURE CONTROLLER ENCLOSURE APPROVED VALVE BOX MASTER VALVE VALVE Z0 _ REDUCED PRESSURE APPROVED STRONGBOX X' oZ 0 i =r BACKFLOW PREVENTER ENCLOSURE o co � PVC SCH. 80 . NIPPLE & UNION. EXPANSION LOOP � o -D a MINIMUM ABOVE GRADE AND SLOPE CONCRETE AT 2% TO DRAIN 0 0 (2) TOTAL. (4" MIN. LENGTH) -_ TYP. 2 (TWO) PLACES " CD 1" TURF AREAS s m 1 IN TURF AREAS BLUE N I VERIFY W/ LOCAL FINISH GRADE 2" IN SHRUB AREAS 0 REMOTE CONTROL VALVE WIRES: 0 EPDXY FILLED WATERPROOF _ STRAINER W/ ) AWG OF #14 SECURE WIRES TO 01 vUj cn ON-OFF SWITCH CONTROL UNIT AT TERMINALS PROVIDED IN CONTROL UNT, I O RED BLACK PIG TAIL EXPANSION 0 MONEL SCREEN ) FINISH GRADE EXTEND ONE COMMON WIRE 7O 12 MAX. z 0 ALL R.C.V.'S AND ONE CONTROL X �RICATION CONTROLLERR 8" MIN. WIRE TO EACH R.C.V. (TYPICAL) COMMON WIRE SHALL BE TIED WATERPROOF ALL PLASTIC VALVE BOX (CARSON OR WIRE CONNECTIONS 18" MIN. 0 INSIDE PROTECTIVE ENCLOSURE EQUAL) WITH PLASTIC INTEGRATED X NOTE: INSTALL BACKFLOW PREVENTER AS REQ. BY LOCAL CODES MOUNT AUTOMATIC CONTROLLER DATE 9/7/10 JOB # OS -019 N AND HEALTH DEPT, VERIFY LOCAL REQS. PROR TO INSTALLATION, ON MOUNTING BRACKETS INSIDE APPROVED VANDAL RESISTANT APPROVED PROTECTIVE ENCLOSURE CONTROLLER ENCLOSURE APPROVED VALVE BOX MASTER VALVE VALVE Z0 APPROVED VALVE BOX RAINBIRD ID TAG: NUMBERED TO MATCH DRAWINGS REDUCED PRESSURE APPROVED STRONGBOX SIZE AS REQUIRED • APPROVED WATERPROOF 0 - REMOTE CONTROL VALVE APPROVED WATERPROOF CONNECTORS BACKFLOW PREVENTER ENCLOSURE Q BRASS OR COPPER CONNECTORS NIPPLE & UNION � PVC SCH. 80 . NIPPLE & UNION. EXPANSION LOOP � CONCRETE FOOTING: INSTALL 3" BALL VALVE BRASS NIPPLES MINIMUM ABOVE GRADE AND SLOPE CONCRETE AT 2% TO DRAIN PVC MALE ADAPTER EXPANSION LOOP PVC SC.40 ELBOW PVC MALE ADAPTER (2) TOTAL. (4" MIN. LENGTH) TYP. 2 (TWO) PLACES " WHITE 1" TURF AREAS ) m 1 IN TURF AREAS BLUE FINISH GRADE 2" SHRUB AREAS I VERIFY W/ LOCAL FINISH GRADE 2" IN SHRUB AREAS BRASS '�Y" ) CODES REMOTE CONTROL VALVE WIRES: EPDXY FILLED WATERPROOF STRAINER W/ ) AWG OF #14 SECURE WIRES TO CONNECTOR OR EQUAL vUj 60 MESH BRASS 90 ELL (TYP.) ON-OFF SWITCH CONTROL UNIT AT TERMINALS PROVIDED IN CONTROL UNT, RED BLACK PIG TAIL EXPANSION 12" MAX. MONEL SCREEN ) FINISH GRADE EXTEND ONE COMMON WIRE 7O 12 MAX. LOOP (MIN.24" LONG) 8� BRASS PLUG o • BRASS UNION (TYP.) ALL R.C.V.'S AND ONE CONTROL �RICATION CONTROLLERR 8" MIN. WIRE TO EACH R.C.V. (TYPICAL) COMMON WIRE SHALL BE TIED WATERPROOF ALL PLASTIC VALVE BOX (CARSON OR WIRE CONNECTIONS 18" MIN. I INSIDE PROTECTIVE ENCLOSURE EQUAL) WITH PLASTIC INTEGRATED X 4 THICK WHEN REQUIRED. LOCKING LID. PLACE AT GRADE IN TURF AREAS AND 3" ABOVE IN °b CONCRETE PAD z_ PLANT BED. o°Daoo�O ° e ° PVC LATERAL LINE ° oa op a o Q 0,11 P�Na ° O o P ° °C ° d° ° ° ° ° PIG TAIL EXPANSION ,� ANGLE TO SPECIFIED DEPTH o oa� WITH 45 -DEGREE ELBOWS PEA GRAVEL NV ) G v �d a ° ° ° pa 6" MINI. ° ° ° ° °DOo ° o O o�o�°D°o� a° ° 000°4 °o° a° ° °ODo D°° LOOP (MIN.24" LONGI ''` '` (CWHITE �c SIZE PER DRAWINGS (MIN. 3 CU. FT.) T ) FG °o ao o °Oo° ad'o popD°pOOo 000 0° a° � ) Jill - I OF 14 BLUE WIRES BRICK, ONE AT EACH PVC SCH. 80 NIPPLE, CORNER OF VALVE BOX � BRICK, ONE AT EACH PEA GRAVEL LENGTH AS REQUIRED Id a a 1 �2" BY 5 -FOOT MI CORNER OF VALVE BOX (MIN. 3 CU. Fr.) RED MASTER CONTROL TYP. TWO PLACES. CONTROL AND COMMON d e e COPPER GROUND ROD. PRESSURE MAIN LINE BLACK VALVE WIRES. TAPE WIRES TO PRESSURE MAIN LINE MAIN LINE °•'. Q I CONDUIT AND IRRIGATION ANGLE TO SPECIFIED CONTROL AND COMMON W a• a INTERCONNECT WHEN REQUIRED ELECTRICAL CONDUIT TO SOURCE DEPTH WITH 45 -DEGREE WIRES. TAPE WIRES TO ELBOWS, SIZE PER FLOW METER DIAMETER SAME PVC SCH: 40 TEE OR ' � III III III IIIIIIII • CONTROL UNIT REQUIREMENTS PVC SWEEP ELBOW DRAWINGS. MAIN LINE SIZE AS FLOW ELBOW . . 120 V., 60 Hz, 2 AMP. MAX. SIZE AS REQUIRED METER SIZE o :a 4 r NOTES: AS FLOW ME ER SIZE NOTES: . IIIIIIII, 1. COMMON WIRE. TO BE WHITE AND CONTROL WIRES TO BE COLOR NOTES: 1. INSTALL CONTROL AND VALVES MINIMUM 2 APART, 2 FROM STRUCTURES 'OR HARDSCAPE IN SHRUB AREAS. 12"X12"X12" CONCRETE THRUST BLOCK PVC MAINLINE CODED. 2. NO SPLICES SHALL BE MADE BETWEEN CONTROLLER AND R.C.V.. 1. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. 2. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. MINIMUM DISTANCE DOWNSTREAM OF 2. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX. 3. PLACE BOXES AT RIGHT ANGLES TO HARDSCAPE OR STRUCTURES. FROM P.O.C. 3. ALL WIRING , CONDUIT OR PLUMBING TO GO THROUGH BOTTOM 3. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO UNINTERRUPTED PIPE (5X DIAMETER OF FLOW METER SIZE) 4. PIPE UPSTREAM OF VALVE ASSEMBLY IS EQUAL IN DIAMETER TO OF CONCRETE FOOTING. DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD DOWNSTREAM PIPING OF VALVE ASSEMBLY. IF NECESSARY, ADD USE TEFLON TAPE OR TEFLON PIPE DOPE ON ALL PVC TO PVC 4. AFTER ESTABLISHMENT OF -ALL PLANT MATERIAL CONTROLLER REDUCE -BUSHING TO BRING PIPING DIAMETER TO VALVE SIZE MINIMUM DISTANCE UPSTREAM OF REDUCE -BUSHING TO BRING PIPING DIAMETER TO REMOTE CONTROL OR METAL TO PVC MALE PIPE THREADS SHALL BE PROGRAMMED TO IRRIGATE SOLELY DURING NIGHTTIME 4. MASTER VALVES 4" AND LARGER TO BE PROVIDED WITH UNINTERRUPTED PIPE (10X DIAMETER VALVE SIZE. REFER TO IRRIGATION CONSTRUCTION DOCUMENTS FOR (TYPICAL) FLANGED CONNECTIONS IN LIEU OF UNIONS. OF FLOW METER SIZE) PIPING SIZE. 1 REDUCED PRESSURE B.F. 2 AUTOMATIC CONTROLLER 3 MASTER VALVE 4 FLOAT METER 5 REMOTE CONTROL VALVE QUICK COUPLING VALVE. APPROVED VALVE BOX TOP OF VALVE SHALL BE APPROVED VALVE BOX GATE VALVE VALVE BOX LABELING NOTE: 24 FINISH GRADE HIGH POP-UP HEAD 40 If 24" POP-UP HEAD FINISH GRADE HEAT BRAND ALL VALVE BOX COVERS IN 2 HIGH LETTERS PER EQUIPMENT LOCATED WITHIN VALVE BOXES. "GV" "FM" 2 BELOW VALVE BOX COVER LABEL FOR ALL GATE VALVES LABEL FOR ALL FLOW MASTER VALVES 1/2" STAINLESS STEEL 1' IN LAWN AR FINISH GRADE 2 PLANTER S LABEL "QCV" FOR ALL QUICK COUPLING VALVES LABEL "FV" FOR ALL FLUSH VALVES » » HOSE CLAMP. 3 REQUIRED 1" IN TURF AREAS „ „ LABEL MV FOR ALL MASTER VALVES LABEL AR FOR ALL AIR RELIEF VALVES "VALVE LABEL STATION" FOR ALL CONTROLL VALVES 2" IN SHRUB AREAS c FINISH GRADE �- 12" 12" MAX. n LEGEND - USE CARSON VALVE BOXES. 71 a• 1. 10" DIAMETER CIRCULAR VALVE BOX. v BRASS OR COPPER NIPPLE LENGTH AS 4 2. EDGE OF LAWN, WALK, FENCE, CURB, ETC. STREET OR REQUIRED NON -PERMEABLE STREET OR Flu 12" 3. 14" x 19" RECTANGULAR VALVE BOX. PAVING ADJACENT 12" MIN. NON -PERMEABLE TO STREET PAVING A JACENT PVC SCH. 80 NIPPLE, SIZE 12 MIN. „ 4. 20 x 30 RECTANGULAR VALVE BOX. TO STREET AND LENGTH AS REQUIRED TYPICAL TWO PLACES 3 LATERAL LINE, SIZE PER LATERAL LINE, SIZE PER °o 00 0 0° ° ° ° o�° °°a° °fl oo ° coo o o°O ���o o°o °O°o�o�00� °� ° ° °poo�J°o° o °o°oo °�°�° o o°° p oop°oo °oog�°o ° °°o ao° BRICK SUPPORTS 12" NOTES A. CENTER VALVE BOX OVER VALVE TO FACILITATE DRAWINGS PVC SCH. 80 NIPPLE, SIZE AND LENGTH AS REQUIRED TYPICAL TWO PLACES DRAWINGS �O REQUIRED2 SERVICING OF VALVE. PEA GRAVEL. o oa °p o° a °°°o °o°\�RICK SUPPORTSTHREE 3 CUBIC FEET MIN. REE REQUIRED) . -PVC MALE ADAPTOR B. SET VALVE BOXES 2" MAXIMUM ABOVE GRADE IN BRASS 90 DEGREE ELL BRASS OR COPPER TYP. TWO PLACES NIPPLE & UNION MULCH COVER OR GROUNDCOVER/SHRUB AREAS - 12" SET FLUSH WITH FINISH GRADE IN TURF AREAS. PRESSURE MAIN LINE PEA GRAVEL C. SET VALVE BOX AND VALVE ASSEMBLY IN GROUND- 3 PVC TEE (SXSXT) PVC SC. 40 PVC SC. 40 PVC TEE (SXSXT) ANGLE TO SPECIFIED (MIN. 2 Cu.FT) COVER/SHRUB AREA WHERE POSSIBLE - INSTALL oR ELBOW STREET ELBOW PRESSURE SUPPLY LINE DEPTH WITH 45 -DEGREE IN TURF ONLY IF THERE IS NO ADJACENT GROUND- STREET ELBOW PVC SCH. 40 ELBOW OR ELBOW ELBOWS, SIZE PERPVC COVER. SC. 40 BRASS 90 DEGREE PRESSURE LINE FITTING DRAWINGS. 1211 STREET ELBOW PVC SC. 40 STREET ELL BRASS 90 DEGREE NOTES: 1. GATE VALVES 2 1/2" AND LARGER SHALL BE AWWA APPROVED AND D. SET VALVE BOXES PARALLEL TO ONE ANOTHER 1 AND PERPENDICULAR TO EDGE. PVC SCH. 40 ELBOW STREET ELBOW NOTES: STREET ELL HAVE A 2" SQUARE OPERATING NUT IN LIEU OF BRASS HANDWHEEL NOTES: 1. LOCATE HEADS 6" FROM SIDE WALK, CURB ETC. BRASS OR COPPER AND FLANGE CONNECTIONS IN LIEU OF UNIONS. 2. GATE VALVES 8" AND LARGER SHALL HAVE TRANSIT ADAPTERS. E. AVOID HEAVY COMPACTION OF SOIL AROUND VALVE 1. LOCATE HEADS 6" FROM SIDE WALK, CURB ETC. 2. INSTALL HEADS FLUSH WITH TOP OF HARDSCAPE AT INTERSECTIONS NIPPLE LENGTH AS 3. PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX PLAN VIEW 2 BOXES TO PREVENT THEIR DEFORMATION/COLLAPSE. 2. INSTALL HEADS FLUSH WITH TOP OF HARDSCAPE AT INTERSECTIONS AND CORNERS. „ #4 REBAR STAKE 36 LONG REQUIRED 4. GATE VALVE SHALL BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE APPROVED AND CORNERS. 3. USE TEFLON TAPE ON ALL MALE THREADED FITTINGS EXCEPT HEAD. NOTE: NOTE: CONTRACTOR TO USE PURPLE LIDS WHEN NON -POTABLE WATER 3. USE TEFLON TAPE ON ALL MALE THREADED FITTINGS EXCEPT HEAD. 4. WHERE NOTED CHECK VALVE SHALL BE INSTALLED UNDER HEAD 4. WHERE NOTED CHECK VALVE SHALL BE INSTALLED UNDER HEAD PLACE PEA GRAVEL PRIOR TO INSTALLATION OF VALVE BOX WATER SOURCE IS USED (SEE PLAN) USING SCHEDULE 80 NIPPLE. USING SCHEDULE 80 NIPPLE. 6 UICK COUPLING VALVE 7 BALL/GATE VALVE .8 VALVE BOX INSTALLATION' 9 HIGH POP-UP HEAD 10 POP-UP SPRINKLER HEAD 24 HARDSCAPING(SEE NOTE 4) POP-UP TURF ROTOR BODY SET TO 11 1 2 3 4 v�� �� p� v� v� v� �� V � v � e v, � v 1/4" ABOVE FINISH GRADE FINISH GRADE �`'��� '� '� '' '' FINISH GRADE AS REQUIRED 13 =I I III I I III III- ` -III I III III- ' 6 MIN. " 2 1 24"MIN. =111 II il� STEP 1 ' 36" MAX 10 1. SLIP BASE SOCKET OVER ENDS OF WIRES. ' ' ' a =III - CLEAN BACKFILL - SEE 12" MIN./',',�/',' �/' ',//',',/ �/ 2. STRIP WIRES APPROX. 3/8" FROM ENDS - 3 5 SPECS. FOR MATERIAL _TTTTT ,' /' ' / ,' , /' ,' ,� /' ,' , 18" MIN. / / 11 6 _ 90% COMPACTION REQUIRED I I Ell STREET OR / ',%�,',�� �. 4 3. PUT CRIMP SLEEVE OVER WIRE ENDS - PROVIDE 6 MIN. OF SAND I I I I " NON -PERMEABLE ,',� /',',� �,', ' / �,',/ 3 STEP 2 CRIMP AND CUT OFF EXCESS WIRE. 7 BEDDING AND SHADDING CT" PAVING ADJACENT /� �, , �/ �/ �,',/ // �,', / �,'� O1 4 -INCH GRATE (INCLUDED) =III - SCH 80 PVC NIPPLE TO STREET (MINIMUM 4" LONG) NON PRESSURE �/ �','�'� �' /' '/ / / LATERAL LINE ��', �� �; �/ �,- 4. APPLY SEALER TO OUTSIDE OF SEALING PLUG - FILL CAVITY WITH SEALER. 2 BUBBLER: SEE IRRIGATION LEGEND (INCLUDED) -- 8 o ►� I I "CONTROL 6 NP` SIZE PER PILAN INSTALL =III .:.:.:.:.• .:.:..:.:.:.:.....•.•.....,...... I-�� /,� �,' / _ - ADJACENT TO PRESSURE ...�.•.. I I I- I SCH 80 PVC NIPPLE SCH 40 PVC ' CLEAN BACKFILL •': ':•. '.::• •.:..: 5. PULL BASE SOCKET OVER CRIMPED CON- 5 NECTION AS FAR AS POSSIBLE. 3 ROOT WATERING SYSTEM: �.•.•.�.�.•... �.�.�.�.�. =III . ' ' = SUPPLY LINE III I I III TYPICAL (2) PLACES TXT 90 ELL MARLEX 90' STREET ELL :; : ;: ' I' •:+.•',e��• • �::��:: '�' .,• 6 STEP 30 FINISH GRADE PR SU SUPPLY UNE _ _ ES RE ICE - ZPRES 6. PUSH SEALING PLUG INTO BASE SOCKET. O5 RWS SAND SOCK (RWS-SOCK) (SEE LEGEND) DIAMETER OFSLEEVE URE _ I I I I I SUPPLY LINE 7. PUSH WIRES TO END OF BASE SOCKET TO ASSURE COMPLETE SEALING OF 6 _ O 1 /2 INCH PVC SCH 80 NIPPLE (INCLUDED) 12 11 10 9_11 I I -III f I 1 III I I III_ NON -PRESSURE LATERAL ANTI -DRAIN VALVE AS REQUIRED - CONTROL WIRES " PRESSURE SUPPLY LINE MIN. 2 OF CLEAN EARTH CONNECTION. O7 1/2 -INCH 90 -DEGREE ELBOW (INCLUDED) � LINE SLEEVE -SIZE TWICE (� DIAMETER OF NON -PRESSURE 7 LATERAL UNE MARLEX 90° STREET ELL STEP 4 8. RAIN BIRD "SNAP-11TE" WIRE CONNECTOR O 12 -INCH SWING ASSEMBLY (INCLUDED) NOTES: NON -PRESSURE LATERAL FITTING NOTES: " 1. BELOW PAVED AREAS A MINIMUM OF 6 LAYER OF CLEAN FILL SAND 8 OR APPROVED EQUAL. 9 1/2 -INCH MALE NPT INLET INCLUDED / ( ) 1. ALL SLEEVES TO BE SCH 40 PVC. SHALL BE INSTALLED ABOVE AND BELOW PIPING. 2. EXTEND ALL SLEEVES 12" BEYOND EDGE OF HARDSCAPING AT BOTH ENDS. NON -PRESSURE LATERAL LINE 2. PROVIDE. MINIMUM COVER OF 24" ON PRESSURE SUPPLY LINES 3" 10 PVC SCH 40 TEE OR EL 3. ROUTE SLEEVING AROUND HANDICAP RAMPS. AND LARGER. 3. WHEN USING RECLAIMED WATER ,MAINTAIN MINIMUM 10' HORIZONTAL 1 1 LATERAL PIPE 4. PIPING UNDER PAVEMENT SUSCEPTIBLE TO TRAFFIC LOADS REFER TO CIN STANDARDS. (24" MIN. TO 36" MAX DEPTH TO TOP OF PIPE BELOW NOTE: SEPARATION BETWEEN POTABLE AND RECLAIMED PRESSURE LINES. HARDSCAPE SURFACE. HARDSCAPING, MOW STRIPS, WHERE LINES CROSS, PROVIDE PVC SLEEVE FOR POTABLE LINE 'MINIMUM 5' EACH SIDE OF RECLAIMED WATER LINE 12 4 -INCH BASKET WEAVE CANISTER (INCLUDED) 1. LOCATE HEAD 2" TO 6" FROM WALKS, CURBS, AND EDGES OF LAWN. 13 TREE 2. USE TEFLON TAPE ON ALL MALE THREADS. I I POP-UP ROTOR 12 TYPICAL TRENCHING 13 WIRE CONNECTOR 14 ROOT WATERING SYSTEM 15 TYPICAL SLEEVING CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (OFD'S) Toro Sentinal controller installed in approved stainless steel Edison meter box enclosure. Contact Aqua Flo with the following numbers for the City of Fontana meter/controller. Fontana part # for a 36 station controller ESB3 6-U2-MPEA 1610K -OBI -VRA Contact: AQUA FLO Tom Raden Phone (805) 895-8909 Fax (661) 718-0192 CITY OF FONTANA LANDSCAPE PLANS Call Underground Service Alert DRAWN BY' KNOX AVENUE - SOUTH SIDE 'SHOWN @ at least 2 days VIENNA LANE TO CITRUS AVE c DESIGt�D BY• DATE I T - TAILS before you dig Know what's below. CHECKED BYe APPRI] Yl DWG, Na 11 before you dig. D DATE� JPCall 4877 26 CITY EN RAM4 RZE 5052 UP. BATE N0. REVISION A 10-14-10 - PLAN CHECK \YRDSCApf P o t y4 . 2782 *MTURV ON roftr/tvDATE Bud a F of DVM CHK DATE 9/7/10 JOB # OS -019 N OF 25 W w Z0 Q fS 0 0 Z Q OC � � O mow+ � U vUj 1z CL 1,-4 U o � CA \YRDSCApf P o t y4 . 2782 *MTURV ON roftr/tvDATE Bud a F of DVM CHK DATE 9/7/10 JOB # OS -019 N OF 25 W w Z0 Q fS 0 0 Z Q OC \YRDSCApf P o t y4 . 2782 *MTURV ON roftr/tvDATE Bud a F of DVM CHK DATE 9/7/10 JOB # OS -019 L1 0 OF 25 M.