HomeMy WebLinkAbout4877-10L4 (0
1 MAINLINE SLEEVE
I" I-4 SLOPE OF STREET 1 LATERAL LINE SLEEVE
— — — — x — — — — — — — — —SLEEVE — — —
x SEE NOTES FOR EXCEPTIONS
JXNX
FLUSH VALVE (TYP.) AIR RELIEF VALVE (TYP.) I 14
(SEE DETAIL) (SEE DETAIL) x TYPICAL DRIPLINE LAYOUT AS PER DETAIL
•
I•• LATERAL LINE
CONNECTION TO
f�
NEXT PARKWAY
,.._.._..... ♦..... _..4.a.. s.. ._.._ ..... ........._.....___....._.....w.. e...»_.._....._..... _««.w.. ...«_...ww.. _..... ...a.. _....i_.. .a.N.....a.._ w._«_•w«_...._.q....._-a-�__-..-_.......••e• w_...w M•-ti•.-�-H•.n...•
�..
24" TYP. 24" TYP.
SLEEVE AT ALL ROAD CROSSINGS (TYP) OF TREE
1 MAINLINE SLEEVE
1 LATERAL LINE SLEEVE
1 WIRE SLEEVE
SEE NOTES FOR EXCEPTIONS
1�
TYPICAALPARKWAY DRIP SYSTEM LAYOUT
c�EE NSTAKES,
IPS FLEXIBLE HOSE—
(USE 795 CEMENT)
PVC TEE (TYP)
GRpO 2"
PVC ELL TO
COMPRESSION
ADAPTER (TYP)
PVC HEADER
SUPPLY
MANIFOLD
METAL STAKES
(SEE NOTE 3)
AIR VACUUM RELIEF--/
VALVE & VALVE
BOX AT HIGHEST
POINTS /
BLANK DRIPLINE
PLIN
`— COMPRESSION
CROSS
NOTES:
1. SEE IRRIGATION NOTES,LEGEND/SPECIFICATIONS FOR ALL DIMENSIONS
AND LATERAL AND INLINE SPACING
2. ALL FITTINGS TO BE USED WILL BE PER MANUFACTURERS
SPECIFICATIONS. USE COMPRESSION FITTINGS ONLY OR APPROVED
EQUAL
3. BURY DRIPLINE 2" BELOW GRADE AND STAKE EACH DRIPLINE AT 4'
O.C. OR AS NECESSARY TO INSURE ' SECURITY
2. ALL TREES ARE TO BE PLANTED WITHIN CENTER OF DRIP LINE RUNS.
KEEP DRIP LINE A MINIMUM OF 2' AWAY FROM TREE TRUNK.
5. INSTALL CHECK VALVES AT 6' ELEVATION CHANGE INTERVALS (TYP)
2 XERIGATION CONTROL ZONE KIT
PVC SCH 40
PVC SCH 80 NIPPLE (TYPI
LENGTH AS REQUIRE
30—INCH LINEAR LEI
OF WIRE, COIL
WATER PROOF CONNED
RAIN BIRD SPLICE
(1 OF
VALVE BOX WITH CC
ID TAG: RAIN BIRD VMD SE
TOP OF M
FINISH G
CONTROL ZONE KIT: RAIN BIRD XCZ-100
(INCLUDES: FPT BALL VALVE,
RBY 100C LSS FILTER, 10OPESB VAI
PSI—M40X-100 PRESSURE REGULATC
PVC LA
PVC SCH 40 MALE ADA
PVC SCH 80 NIPPLE, CLOSE (1 OF
PVC SCH 80 UNION
SERVICING ASSEME
PVC MAI
3—INCH MINIMUM DEPTf
3/4—INCH WASHED GRAV
BRICK (1 1
PVC SCH 80 NIPPLE (2—
LENGTH, HIDDEN) A
PVC SCH 40 1
PVC SCH 40 TEE OR
Call Underground Service Alert
at least 2 days
before you dig
2
12" '/�\�j ��//� /r
RIPLIN
DATE 9/7/10
RAINBIRD 1806 -SAM -R13 -18Q QUARTER ROTOR HEAD 13-18' .4
30
ELBOW
RAIN BIRD 1806 -SAM -R13 -18H HALF ROTOR HEAD 13-18' .8
(CA) COMPRESSION ;:7
ADAPTER
IPX FLEX HOSE
RAIN BIRD 1806 -SAM -R13 -18F FULL ROTOR HEAD 13-18' 1.6
(USE 795 CEMENT)
PVC PIPING
PVC TEE (TYP)
30
(SXSXS)
RAIN BIRD . 1806 -SAM -R17 -24H HALF ROTOR HEAD 17-24' 1.5
ZONE FLUSH VALVE
PLUMBED TO PVC (TYP)
(SEE DETAIL)
BURY DRIPLINE 2" BELOW FINISH GRADE
(I.E. TOP OF SOIL) FOR TURF AREAS.
FOR SHRUB AREAS BURY 2" BELOW ,
FINISH GRADE THEN ADD 2"-3" OF BARK
MULCH ON TOP. (TYP.)// " \
METAL STAKE (TYP)
(SEE NOTE 3)
TRIANGULATE EMITTER SPACING (TYP)
(SEE NOTE BELOW FOR LATERAL AND
IN LINE SPACING)
DRIPLINE LATERAL
(OR EQUAL) SEE LEGEND/
SPECIFICATIONS FOR LATERAL
AND IN LINE SPACING
AREA PERIMETER
PERIMETER LATERALS — 12" FROM
PAVING OR EDGE OF TREATMENT
AIR RELIEF LATERAL — BLANK
DRIPLINE (OR EQUAL)
(CENTERED ON MOUND OR BERM)
AIR/VACUUM RELIEF VALVE
PLUMBED TO DRIPLINE
(OR EQUAL) AT EACH HIGH POINT
(SEE DETAIL)
CHECK VALVES AS NECESSARY (TYP)
(SEE NOTE 5)
PVC SUPPLY MANIFOLD
SUPPLY MANIFOLD
CONNECTION (PVC TO TEE)
(OR EQUAL)
DRIP REMOTE CONTROL VALVE
(SEE DETAIL)
TOP OF MULCH
7–INCH ROUND VALVE BOX:
/— AIR RELIEF VALVE KIT:
RAIN BIRD. X17000
AR VALVE KIT
"INISH GRADE
'E DRIPLINE TUBING:
END FOR TYPE)
PVC LATERAL PIPE
SEE LEGEND
NOTE:
PLACE ALL AIR RELIEF ASSEMBLY
AT HIGHEST SPOT IN THE FIELD FOR
EACH SYSTEM.
""°�a7�'n °re'°�c�, C 3) CONTROL ZONE KITS 4) AIR RELIEF VALVE
3–INCH MINIMUM DEPTH OF
3/4–INCH WASHED GRAVEL
1210
�/ DRIPLINE
\\(CT)S TE
IPLINE (CA) COMPRESSION'/'
ADAPTER
/
PVC PIPING
PVC TEE (TYP).
(SxSXS)
IPS FLEX HOSE
(USE 795 CEMENT)
ZONE FLUSH VALVE
PLUMBED TO PVC (TYP)
(SEE DETAIL)
METAL STAKE (TYP)
11 11 (SEE NOTE 3)
TRIANGULATE EMITTER SPACING (TYP)
X (SEE NOTE BELOW FOR LATERAL AND
X IN LINE SPACING)
CHECK VALVES AS NECESSARY (TYP)
(SEE NOTE 5)
PVC SUPPLY MANIFOLD
1 1-1-4 Fl- DRIP REMOTE CONTROL VALVE
CK 1 (SEE DETAIL)
11 SUPPLY MANIFOLD
CONNECTION (PVC TO TEE)
(OR EQUAL)
DRIPLINE LATERAL
(OR EQUAL) SEE LEGEND/
SPECIFICATIONS FOR LATERAL
AND IN LINE SPACING
AREA PERIMETER
AIR RELIEF LATERAL — BLANK
DRIPLINE (OR EQUAL)
(CENTERED ON MOUND OR BERM)
PERIMETER LATERALS — 12" FROM
PAVING OR EDGE OF TREATMENT
AIR/VACUUM RELIEF VALVE
PLUMBED TO DRIPLINE
(OR EQUAL) AT EACH HIGH POINT
DRIPLINE SPACING NOTE:
DRIPLINE LATERALS WITHIN TURF AREAS
ARE TO BE SPACED AT 12" O.C.
DRIPLINE LATERALS WITHIN
SHRUB/GROUND COVER AREAS .ARE TO
BE SPACED AT 18" O.C.
(SEE DETAIL)
o°o°o°o°o°o°o°oo"O
n�n�n�n�n�n�n�n°
5 )FLUSH VALVE ASSEMBLY
NOTE:
RESIDENTIAL CONDITION WITH DRIVEWAYS IN PARKWAY
NOTES:
LOCATE SERVICE LATERAL IN EACH TURF/PLANTED AREA
AT ONE END OF THE AREA. LOCATE FLUSH VALVE AT
OTHER END OF TURF/PLANTED AREA AS PER DETAIL—(1)
FLUSH VALVE PER AREA. LOCATE AIR RELIEF VALVE AS
REQUIRED BY DETAILS
SLEEVING NOTES:
ALL DRIVEWAYS ARE TO BE SLEEVED WITH AN
APPROPRIATELY SIZED MAIN LINE, LATERAL LINE AND
WIRE SLEEVE. REFER TO LEGEND AND NOTES TO
DETERMINE SLEEVE SIZING.
OMIT:
MAIN LINE AND WIRE SLEEVES UNDER ANY
DRIVEWAY THAT IS BEYOND THE LAST VALVE
ALONG THAT BRANCH OF THE SYSTEM.
LATERAL LINE SLEEVE UNDER DRIVEWAY THAT IS
BETWEEN SEPARATE IRRIGATION SYSTEMS.
RESIDENTIAL CONDITION WITH NO DRIVEWAYS IN PARKWAY
NOTES:
LOCATE SERVICE LATERAL IN EACH TURF/PLANTED AREA
AT CENTER OF THE AREA. LOCATE (1) FLUSH VALVE
AT EACH END OF TURF/PLANTED AREA AS PER
DETAIL—(2) FLUSH VALVES PER AREA. LOCATE AIR
RELIEF VALVE AS REQUIRED BY DETAILS
IRRIGATION NOTES
DIAGRAMMATIC PLAN
THIS SYSTEM IS DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED
AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN
PLANTING AREAS AND JOINT TRENCHES WHEREVER POSSIBLE.
SPRINKLER ADJUSTMENT REQUIRED
THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS
FOR OPTIMUM PERFORMANCE AND PREVENT OVERSPRAY ONTO WALKS AND
ROADWAYS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST
DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS. CONTRACTOR TO USE
PRESSURE COMPENSATING SCREENS WHEN RADIUS IS REDUCED MORE THAN FIFTY
PERCENT (50%).
FIELD CONDITIONS
DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS INDICATED ON THE
DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN OBSTRUCTIONS OR
GRADE DIFFERENCES EXIST AND SHOULD BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER. IN THE EVENT THAT THIS NOTIFICATION IS
NOT PERFORMED, THE CONTRACTOR MUST ASSUME FULL RESPONSIBILITY FOR ANY
REVISIONS REQUIRED.
SWING JOINTS
INSTALL ALL HEADS WITH DOUBLE OR TRIPLE SWING JOINTS, USING STREET ELLS,
AS PER DETAIL.
MINIMUM PRESSURE AND MAXIMUM GALLONS REQUIRED
THE SPRINKLER SYSTEM DESIGN IS BASED ON A MINIMUM OPERATIONAL PRESSURE
AND A MAXIMUM DEMAND AT THE POINT OF CONNECTION, AS NOTED ON THE PLAN.
BEFORE INSTALLING THE SYSTEM, CHECK POINT OF CONNECTION AND IMMEDIATELY
NOTIFY CONTRACTING OFFICER IF PRESSURE IS NOT AS NOTED OR THE REQUIRED
GALLONS PER MINUTE IS NOT AVAILABLE.
WATER LINE UNDER PAVING
ALL MAINLINE UNDER PAVING SHALL BE INSTALLED 24" DEEP. ALL LATERAL LINES
UNDER PAVING SHALL BE SCH 40 PVC AND INSTALLED 24" DEEP.
ALL LINES TO BE INSTALLED IN SLEEVE 2X DIA. OF LATERAL LINE.
SYSTEM COVERAGE
THE IRRIGATION CONTRACTOR IS TO ADJUST HEAD LOCATIONS IN THE FIELD IN
ORDER TO GUARANTEE 100% COVERAGE. CONTRACTOR TO CONTACT THE
CONTRACTING OFFICER PRIOR TO ANY MAJOR CHANGE(S) RESULTING IN
ADDITIONAL COST TO THE OWNER.
HEAD INSTALLATION ADJACENT TO HARDSCAPE (FONTANA)
ALL ABOVE GROUND IRRIGATION HEADS ADJACENT TO STREETS OR STREET ADJACENT IMPERVIC
SURFACES ARE TO BE INSTALLED 24" AWAY FROM THE EDGE OF THE SURFACE. SEE SPRAY
HEAD DETAILS FOR ADDITIONAL INFORMATION.
EACH PLANT IS SERVICED BY A CERTAIN NUMBER OF EMITTERS:
1 EMITTER/ 1 GALLON PLANT MATERIAL
2 EMITTER/ 5 GALLON PLANT MATERIAL
3 EMITTERS/ 15 GALLON PLANT MATERIAL
5 EMITTERS/ 24" BOX PLANT MATERIAL
EACH CENTRAL EMISSION DEVICE HAS (8) DRIP EMITTER OUTLETS.
LOCATE CENTRAL EMISSION DEVICES, AS REQUIRED, TO SERVICE
PLANT MATERIAL BASED UPON THE CONTAINER SIZE CRITERIA. THE
MAXIMUM DISTRIBUTION TL
O1 7" IRRIGATION BOX
OFINISH GRADE OR
MULCH MINIMIZE
PORTIOI`
O3
1/2- DRIP LATERAL
LINE
OFLUSH VALVE
RAINBIRD MDCF CAP/
MDCF COUP
2"-3'
O PEA GRAVEL
is : UbINVU 5 AK:
SECT CAP INSTALLED
V TUBING OUTLET
ANT, SEE PLANTING
AN FOR SIZE AND TYPE
NISHED GRADE
4TIVE OR
AMENDED SOIL
ROOT BALL
DISTRIBUTION TUBING
NOTE: FROM DRIP EMITTER
DISTRIBUTION TUBING SHALL BE INSTALLED A MINIMUM OF 3" BELOW FINISHED GRADE.
THE NUMBER AND VOLUME OF EMITTERS SHALL BE AS INDICATED ON THE
IRRIGATION DRAWINGS. FOR PLANTS WITH MULTIPLE EMITTERS, SPACE OUTLETS
EVENLY AROUND THE ROOT BALL.
THE DRIP TUBING OUTLET SHALL BE POSITIONED OVER THE PLANT ROOT BALL.
6) DRIP EMITTER TUBING OUTLET
IRRIGATION LEGEND
SYMBOL MFG. MODEL NO. DESCRIPTON RAD. GPM
PSI
DATE 9/7/10
RAINBIRD 1806 -SAM -R13 -18Q QUARTER ROTOR HEAD 13-18' .4
30
T
RAIN BIRD 1806 -SAM -R13 -18H HALF ROTOR HEAD 13-18' .8
30
RAIN BIRD 1806 -SAM -R13 -18F FULL ROTOR HEAD 13-18' 1.6
30
+
RAIN BIRD 1806 -SAM -R17 -24Q QUARTER ROTOR HEAD 17-24 .75
30
V
RAIN BIRD . 1806 -SAM -R17 -24H HALF ROTOR HEAD 17-24' 1.5
30
Q
RAIN BIRD 1806 -SAM -R17 -24F FULL ROTOR HEAD 17-24' 3.0
30
CONTRACTOR MUST USE RAINBIRD 1806 -SAM ADJUSTABLE ARC NOZZLES OR RAINBIRD VAN
NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE.
H
THE CONTRACTOR IS REQUIRED TO USE RAINBIRD 1806 -SAM (SEAL-O-MATIC)
�
�
POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH TOR GREATER THAN
ELEVATION CHANGE- OR AS NEEDED IN FIELD.
�z
THE 8' SPRAY HEADS MAY BE SUBSTITUTED WITH 10' NOZZLES AS REQUIRED IN
THE FIELD. ANY HEADS THE NEED A REDUCTION OF MORE THAN 50% OF THE
LISTED SPRAY PATTERN WILL REQUIRE RAINBIRD SCREENS.
■
HUNTER MPR40-12-CV-MPss530 STRIP SPRAY ROTOR 5'x30' .44
35
•
HUNTER MPR40-12-CV-MP1000-90-210 ADJ. SPRAY ROTOR 8'-15' .37
35
0
HUNTER M PR40-12-CV-M P2000-90-21 0 ADJ. SPRAY ROTOR 13'-21' .74
35
Q
HUNTER MPR40-12-CV-MP2000-360 ADJ. SPRAY ROTOR 13'-21' 1.47
35
O
HUNTER MPR40-12-CV-MP3000-90-210 ADJ. SPRAY ROTOR 22'-30' .86
35
O
HUNTER MPR40-12-CV-MP3000-360 ADJ. SPRAY ROTOR 22'-30' 1.82
35
B
HUNTER RZWS-SLEEVE-36-25-CV TREE ROOT ZONE BUBBLER .5
30
MP ROTATOR NOTES:
- WHEN SPRAY RADIUS IS BELOW 90 DEGREES, CONTRACTOR TO SUBSTITUTE ADJUSTABLE
'MPCorner' NOZZLE
RAINBIRD XFD-06-12-250 DRIP LINE SYSTEM (TURF) 7
30
y'
Per 100s.f.
RAINBIRD XFD-06-12-250 DRIP LINE SYSTEM (PKWY)7
30
Per 100s.f.
pv
RAINBIRD FLUSH VALVE ASSEMBLY - SEE DETAIL 5, THIS SHEET
RAINBIRDAIR RELIEF VALVE - SEE DETAIL 4, THIS SHEET
THE CONTRACTOR WILL NEED TO FIELD LOCATE THE AIR RELIEF VALVES AT
THE HIGHEST LOCATIONS ON EACH DRIP LINE SYSTEM.
FLUSH VALVES ARE TO BE INSTALLED AT THE END POINT OF ALL DRIP LINE SYSTEMS.
®
RAINBIRD PEB-PRS-D SERIES REMOTE CONTROL VALVE W/ PRESSURE
REGULATOR- SIZES INDICATED
Q
RAIN BIRD 33 DLRC LOCKING W/ RUBBER CAP, QUICK COUPLER.
H
NIBCO BRASS BALL VALVE (LINE SIZE) T-585-70 (3/4"-2") / T-580-70-66 (2-3/4"-311)
4" AND LARGER TO BE FEBCO NRS SERIES GATE VALVE - LINE SIZE.
D
WATER METERS - REFER TO CIVIL PLAN
FEBCO 825Y REDUCED PRESSURE BACKFLOW PREVENTER W/ 2" WYE -STRAINER
- SEE DETAILS
O
AUTOMATIC CONTROLLER LOCATION -SEE NOTE.
0
'DATA INDUSTRIAL'- HFSM-150 FLOW SENSOR
O
2 1/2" GRISWORLD 2230 ( NORMALLY CLOSED) MASTER VALVE. INSTALL
DOWNSTREAM FROM FLOW SENSOR.
- FOR VALVES USING 0.2-4 GPM, USE RAINBIRD XCZ-LF-100-PRF CONTROL ZONE KIT -
®
REMOTE CONTROL VALVE FOR DRIP SYSTEMS.
- FOR VALVES USING 4-20 GPM, USE RAINBIRD XCZ-100-PRB-COM CONTROL ZONE KIT
-
REMOTE CONTROL VALVE FOR DRIP SYSTEMS.
PVC SCH 40 LATERAL LINE- 12" COVER IN PLANTING AREAS, 24" COVER UNDER PAVING.
- SIZES INDICATED.
MAINLINE - SEE DETAIL FOR INSTALLATION DEPTHS. - SIZES INDICATED.
Mainlines (pressurized) 11/2 inch and smaller shall be Schedule 40 solvent -weld P.V.C.
Mainlines (pressurized) 2 inch through 3 inch shall be Class 315 solvent -weld P.V.C.
CONTRACTOR TO USE INSTALL THRUST BLOCKS TO 2" MAINLINE,
PVC SCH 40 WIRE SLEEVE.
PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIA. OF PIPE ENCASED. - PROVIDE
SLEEVES UNDER HARDSCAPE-(CONCRETE / ASPHALT IN EXCESS OF 4' WIDE).
NOTE:
* ALL CONTROL WIRE, LATERAL AND MAINLINE PIPE RUNS
TO BE INSTALLED IN SEPERATE SLEEVES.
* ALL SLEEVING TO BE SCH. 40 PVC.
* SIZING :
- WIRE SLEEVES, MUST BE OVERSIZED LEAVING AMPLE ROOM
FOR FUTURE WIRE ADDITIONS OR REPAIRS.
- PIPE SLEEVING TO BE 2 x DIAMETER OF PIPE ENCASED.
1-11
INDICATES WATER REQUIREMENT
x INDICATES STATION NUMBER
x x•
INDICATES CONTROLLER
X x
o INDICATES GPM
x
INDICATES VALVE SIZE
INDICATES HYDROZONE AREA
PIPE SIZING / SLEEVING
THIS LEGEND TO BE USED FOR LATERAL LINE PIPE
INSTALLATION. ALL MAINLINE TO BE SIZED AS
TT TTIT!"A TT'.T 11T7 TIT ATT
11VL11�ti1�L V1V rLt11V
PIPE SIZE GPM's APPROX. # HEADS
3/4" 1-8 1-10
1" 9-12 11-14
1 1 /4" 13-22 15-20
11/211 23-38 21-30
2" 39-50 31-35+
NOTE: LATERAL SIZE IS SHOWN AT EACH VALVE EXIT.
NOTE: CONTRACTOR IS REQUIRED TO PROVIDE
SLEEVING FOR ALL LATERAL LINE AND MAINLINE
UNDER ALL PAVING SURFACES THAT EXCEED 4' WIDE.
CITY OF FONTANA
LANDSCAPE PLANS
DRAVN BY' KNOX AVENUE - SOUTH SIDE AS SHOWN
VIENNA LANE TO CITRUS AVE
DESIGNED BYi Wit,
IRRIGATION DET S, TES & LEGEND
CHECKED BYt APPROVEDA Y- - /� , Zd DWG, NILS 7,6
DATE' 4877
CITY ENGD�ER R,C.E. 51152 EXP. DATE
S 1 T E S C A P E S
Landscape Architecture
and Planning
3190 B2 Airport Loop Drive
Costa Mesa, CA 92626
Richard Polhamus, License CA—#2782
(949) 644-9370 (714) 210-3140 FAX
N0. REVISION
ITY & MWD AI
10-14-10 - PLAN CHECK
\,01DSC4jo
C_ ` p ti P 0(
y4 G� i
2782 ys,
of
0 fO
�;00^ DAA
9�F Be%
�F CALF
DVM
CHK
DATE 9/7/10
JOB #
OS -019
L 9
Q
N
�z
a
[
W
Uj
Z
Q
W
O
c�
X23
H
W
�
�
O
�z
\,01DSC4jo
C_ ` p ti P 0(
y4 G� i
2782 ys,
of
0 fO
�;00^ DAA
9�F Be%
�F CALF
DVM
CHK
DATE 9/7/10
JOB #
OS -019
L 9
OF Zv