HomeMy WebLinkAbout3801-1N M jo 0 CD 0 00 0 cr 3 0 0 0 I U) I 0 z v N Lo i GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (-GREEN BOOK"). ALL REFERENCE SPECI FI CA TIONS AND STANDARDS SHALL_ BE THE LATEST EDI TION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL I MMEDI A TEL Y REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELI NEA TORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DI VISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WI THOU T OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CAL TRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERA TION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE 0 THER VI SE NOTED. 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16. REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESI GNA TION C700 FOR V.C.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE U77L1 TY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF , THE SEWER LATERAL. 32. IF EXIS77NG UTIL171ES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35. APPROVED SOIL STERI LAN T IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 37. UPON COMPLET70N OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CITY OF FONTANA SEWER IMPROVEMENT PLANS COYOTE CANYON ROAD AND ROADRUNNER ROAD PRIVATE ENGNEER NOTE CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. UTILITY PURVEYORS WATER WEST VALLEY WATER DISTRICT ATTENTION: LON TSAI INDEX MAP/DETAILS 855 W. BASELINE TELEPHONE: (909) 875-1804 LOCATION OF STORM DRAIN, DELETED "NOT RIALTO, CA 92377 SHEET 4: ROADRUNNER ROAD STA. 26+00.00 TO STA. 34+82.38 SHEET 5: SEWER CITY OF FONTANA ATTENTION: BRIAN WREN 8353 SIERRA AVE. TELEPHONE: (909) 350-6632 SEWER AT 36+75.50 FONTANA, CA 92335 CROSS CREEK WAY STA. 11+91.04 TO STA. 12+76.04 ELECTRIC SOUTHERN CALIFORNIA EDISON COMPANY ATTENTION: JEFF BURT 800 W. CIENEGA AVENUE TELEPHONE: (909) 592-3737 SAN DIMAS, CA 91773 GAS THE GAS COMPANY ATTENTION: STEVE ROBLES 16231 VALLEY BOULEVARD TELEPHONE: (909) 428-8407 FONTANA, CA 92335 TELEPHONE VERIZON ATTENTION: FRANK ANGUSTAIN 16071 MOJAVE DRIVE, BLDG. B TELEPHONE: (760) 245-0330 VICTORVILLE, CA 92392 CABLE ADELPHIA COMMUNICATIONS ATTENTION: LEWIS MCDONALD 1500 S. AUTOCENTER DRIVE TELEPHONE: (909) 975-3343 ONTARIO, CA 91761 SHEET INDEX SHEET 1: 77TLE SHEET/VICINITY MAP/GENERAL N07ES TYPICAL SECC77ONS SHEET 2: INDEX MAP/DETAILS SHEET 3. ROADRUNNER ROAD STA. 20+25.70 TO STA. 26+00.00 v3 WILDWOOD LANE STA. 11+75.95 TO 12+21.66 LOCATION OF STORM DRAIN, DELETED "NOT CRIMSON STREET STA. 8+91.96 TO 9+39.65 SHEET 4: ROADRUNNER ROAD STA. 26+00.00 TO STA. 34+82.38 SHEET 5: MANHOLE SHAFT SAFETY LEDGE DETAIL REVISED ALIGNMENT REVISED & ADDED MANHOLE. BROOKSIDE AVENUE STA. 19+18.03 TO STA. 20+80.11 SHEET 6: COYOTE CANYON ROAD STA. 29+28.22 TO STA. 35+50.00 ROCKCREST WAY STA. 9+89.00 TO STA. 10+81.00 SHEET 7. COYOTE CANYON ROAD STA. 35+50.00 TO STA. 46+00.00 SEWER AT 36+75.50 CROSS CREEK WAY STA. 11+91.04 TO STA. 12+76.04 SHEET 8: COYOTE CANYON ROAD STA. 46+00.00 TO STA.Ea BASIS OF BEARINGS: LEGAL DESCRFTION : OWNER/DEVEi_OPER ARE BASED ON THE WESTERLY LSE OF THE NORTHEAST QUARTER OF SECTION 23, TOWNSHIP BEING A OF A PORTION OF THE SOUTHEAST 1/4 OF SECTION A TOWNSI-1P 1 NORTH, RANGE 6 WEST, SAN BERVARDINO MEF DIAK 1 NORTH, RANGE 6 WEST, SAN BE RNARDNO MERDIAN, COUNTY OF SAN BERNARDNO. Centex Homes AS SHOWN ON AMENDM MAP OF TRACT W.13750, 1265 Corona Pointe Corm FLED N BOOK 250 OF MAPS, AT PAGES 48 THROUGH Corona, CA 92879 66, NCLUSNE, N THE OFRCE OF THE COUNTY PI} (951) 479-9300 RECORDER OF SAN BERNARDNO COUNTY, BRIG Fax (951) 372-28'19 NORTH OOr30'24' WEST. BENCH MARK: REV. REVISION DESCRIPTION DEQ BY METROPOLITAN WATER DISTRICT SO. A O CALEORNA 1992 RANCHO CUCAMONQA, NEAR THED'(j NTEfRSECTION OF SUl&ff AVE AND COY AVE AT THE 0 eoo��qFESS/0� SOL ENCS .0 5 p. CV S c� U Onm and ASSOC., INC. � N 1983 m 1011 NL ARMANDO STREET E . 03A311I Z. ANAHEIM, CA 92806 Pty (714) 630-1626 LIP CIVIL Fax (714) 630 -IM F OF r AL\ i � DATE I ENGR. I CITY I DATE SOUTHWEST CORNER OF CI•;RIRY AVE AND %-A%A I I AVE 101 FEET WEST OF THE OF COY AVE APD 37 FEET SOUTH OF THE CENTERIJNE OF SUMW AVE SET FLUSH ON THE NORTHWEST CORDER OF A 10 FOOT WIDE - CATCHBASIV 0.8 FOOT SOUTH OF CURB FACE A STANDARD MWDSC 3 INCH BRASS DISK STAMPED '33A 19®2'. NAVD 88 - 1508.56 09EE I DIAL TWO WORKING BEFORE YOU DIG DAYS AYOU D I G RE TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 3 2 Ecorzr� �J2 wiiUG 0� 05 %// 2� D I�Tfp 5 4VEIZ F[IDN! SfiA• 5 tl 9s-ro sfiA.58t24.G2 v3 AREWSED LOCATION OF STORM DRAIN, DELETED "NOT 1 8 CI ENGINE R.C.E. 51152 DATE: FOR CONSTRUCTION" ADDED STUBS AND PROFILE, REVISED ALIGNMENT REVISED & ADDED MANHOLE. ENGINEERS NOTICE TO COAffFMCTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND OR OVERHEAD UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE APPROXIMATE. THE ENGINEER ASSUMES NO LIABILITY AS TO THE EXACT LOCATION OF SAID LINES NOR FOR UTILITIES OR IRRIGATION LINES WHOSE LOCATION ARE NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL UTILITY AND IRRIGATION COMPANIES PRIOR TO WORK TO ACCURATELY IDENTIFY THESE LOCATIONS, WHETHER OR NOT SHOWN HEREON, AND IS RESPONSIBLE FOR ANY DAMAGE OR PROTECTION OF THESE LINES. PHASED UTILITY RELOCATIONS MAY BE NECESSARY AND SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CLOSELY COORDINATE HIS ACTIVITIES WITH THOSE OF ALL UTILITY COMPANIES. THE CONTRACTOR SHALL CALL IN A LOCATION REQUEST TO UNDERGROUND SERVICE ALERT (U.S.A.) PHONE 1-800-227-2600. TWO (2) WORKING DAYS PRIOR TO DIGGING. NO CONSTRUCTION PERMIT ISSUED BY PUBLIC WORKS DEPARTMENT SHALL BE VALID INVOLVING UNDERGROUND FACILITIES UNLESS THE APPLICANT HAS AN INQUIRY IDENTIFICATION NUMBER ISSUED BY U. S.A. THE ESTIMATED QUANTITY FOR EACH SPECIFIC ITEM OF THE WORK DESIGNATED ON THE PLANS SHALL BE CONSIDERED AS APPROXIMATE ONLY AND NO GUARANTEE IS MADE THAT THE QUANTITIES WHICH CAN BE DETERMINED BY COMPUTATIONS, BASED ON THE DETAILS AND DIMENSIONS SHOWN ON THE PLANS, WILL EQUAL THE ESTIMATED QUANTITIES. THE ESTIMATE OF QUANTITIES IS PROVIDED BY THE ENGINEER ONLY FOR THE CONVENIENCE OF THE OWNER, THE CONTRACTOR SHALL MAKE HIS OWN DETERMINATION AND BE RESPONSIBLE FOR HIS OWN CONSTRUCTION QUANTITIES BEFORE SUBMITTING A BID. ANY ITEM OF WORK, OR PORTION THEREOF, REQUIRED BY THESE PLANS WHICH IS NOT SP4CIFICALLY LISTED IN THE ESTIMATE OF QUANTITIES SHALL BE CONSIDERED AS I NCL UDEQ IN THE OTHER ITEMS OF WORK. UPON FINAL DESIGN OF THE INTERIOR PLUMBING SYSTEM FOR EACH LOT, CONTRACTOR IS TO DETERMINE WHICH LOTS WILL REQUIRE BACKWATER VALVES IN ACCORDANCE WITH SECTION 710.1 OF THE UNIFORM PLUMBING CODE. BACKWATER VALVES AS NOTED ON THESE PLANS. WERE LOCATED IN RESPECT TO PAD ELEVATION, IN LIEU OF FLOOD RIM ELEVATION OF LOWEST FIXTURE, VERSUS NEXT UPSTREAM TOP OF RIM ELEVATION OF MANHOLE. TOP AND BOTTOM ELEVATION CALLOUT FOR ALL PROPOSED OR EXISTING UTILITIES AND FACILITIES SHOWN ON THESE PLANS ARE APPROXIMATE. WALL THICKNESSES FOR ALL UTILITIES AND FACILITIES PROPOSED OR EXISTING BY INSTALLING CONTRACTOR MAY VARY DUE TO MANUFACTURER'S TYPE, USE AND SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL EXISTING AND PROPOSED UTILITY AND FACILITY CROSSING LOCATIONS SHOWN ON THESE PLAN PRIOR TO INSTALLATION TO INSURE THE TYPE OF MATERIAL HE HAS CHOSEN MEETS THE MINIMUM SEPARATION REQUIREMENTS OF CITY OF FONTANA. SHOULD CONSTRUCTION1 OF M -E REQUIRED 1u41OVEMUM NOT �• ►, �( CO &HENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN FUE<M AND CAFIED FORTH N A DLKIEENT MANNER, THE CITY EW*EBR Y(v' 7 MAY REOUIRE REVISIONS TO TI -E PLANS TO BRNQ TFBN INTO a. IL • n WITH CONDITIONS APD STANDARDS N SECT. NORTH R/W r� 22' 3' 8' 11 ' rMIN. 29' I 27o I I Mac 2.1 2' BENCH CURB & 12' SIDEWALK/DG TRAIL GUTTER PROP. 12" VTR. PROP. 36" STORM DRAIN - 22 1 RAIN R�W LETTERED LOT FOR TRAIL & LANDSCAPE 8' 2' 6' 6' 12' DG T MIL -9-I- PX 2�� M SEAL -ENGINEER o FESS Crn rn NO. C041983 EXP. 3/31/08 s� CNII. 97F OF CA - 2' BENCH 12' 0 CURB & GUTTER COYOTE CANYON ROAD 1 ROADRUNNER ROAD CHERRY AVENUE SUMMIT J � AVENU� -ITE LOCATION DUNCAN CANYON ROAD 5�P LYTLE CREEK ROAD DUNCAN CANYON ROAD N. T.& SEWER ESTIMATE OF OUANTMES QUAN7111ES O1 CONSTRUCT 12" EXTRA STRENGTH VCP SEWER UNE, BEDDING PER DETAIL ON SHEET 2. 2O CONSTRUCT 72" DIA. ECCENTRIC MANHOLE PER CITY OF FONTANA STD. NO. 112 WITH SAFETY LEDGE PER APWA STD. NO. 330-1 PER DETAIL ON SHEET 5. 30 CONSTRUCT 72" DIA. ECCENTRIC MANHOLE PER CITY OF FONTANA STD. NO. 112. 4O REMOVE EXISTING STUB -OUT AND JOIN EXISTING MANHOLE. O CONSTRUCT 8" EXTRA STRENGTH VCP SEWER LINE, BEDDING PER DETAIL ON SHEET 2. 60 CONSTRUCT 8" DUCTILE IRON PIPE CLASS 350 SEWER LINE, BEDDING PER DETAIL ON SHEET 2. O INSTALL TEMP. 8" END PLUG. 8O CONSTRUCT 48n DIA. ECCENTRIC MANHOLE PER C17Y OF FONTANA STD. NO. 112. O9 CONSTRUCT 60" DIA. ECCENTRIC MANHOLE PER CITY OF FONTANA STD. NO. 112. 10 INSTALL 24" DIAMETER -3/8" THICK STEEL CASING PER DETAIL "A" ON SHEET 5. 11 INSTALL 18" DIAMETER -3/8" THICK STEEL CASING PER DETAIL "B" ON SHEET 5. 12 CONSTRUCT 12" DUCTILE IRON PIPE CLASS 350 SEWER LINE, BEDDING PER DETAIL ON SHEET 2. 29' I I27, 14 15L' I � PROP. 8" SWR. COYOTE CANYON ROAD N.T.S. 22' PROP. 12" SWR. 22' 1,167 LF 4 EA 4 EA i271 LF 1 LF LF 10 EA 1 10 EA 2 2 EA 110 LF 100 LF 160 LF SOUTH R/W so 16' /ARIES 6' 3' 0' MAX MIN. 2% CURB & GUTTER PROP. 12" WTR. VARIES 0.5'MIN. 5.5'MAX. 0 Not�f_ 2' BENCH MEANDERING SIDEWALK EAST R/W J.1 1 0.5' .. . MEANDERING)•GUTTER SIDEWALK PROP STORM D-. 21 2' BENCH ROADRUNNER ROAD N.T.S. SM SHEET 2 FOR LDDC 81$'I' AND TYPICAL TRENCH DETAIL CITY OF FONTANA, CALIFORNIA AEI�CASC ENGINEERING SEWER IMPROVEMENT PLANS 937 SOUTH VIA LATA SUITE 500 COLTON, CA 92324 PH. 909 X83-0101 FAX 909 783-0108 DRAWN BY. OS COYOTE CANYON ROAD � AND ROADRUNNER ROAD ' SCALE: AS SHOWN ABOVE DESIGNED BY: OSJULY, DATE: 2005 PREPARED BY: 'C'HRIS D. CUMMINS R.C.E. NO. 41983 EXP. DATE: 3/31108 DATE: �`� 6(o CHECKED BY: SBC J. M APPRO _ ��3801 DRAWING NO.: 1 8 CI ENGINE R.C.E. 51152 DATE: -W�