HomeMy WebLinkAbout4858-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE
STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE
PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO
THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK
IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA
MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL
TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE
CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND
OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE OTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER
PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING
DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC,
CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE OF CURB.
14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE
PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE
CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE
BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE
MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES.
20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR.
21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY
ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING
OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE,
THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO
THE CITY OF FONTANA STANDARD DETAILS.
26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL.
28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY
SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A
GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING.
33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON
COMPLETION OF PAVING.
34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES
TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE
SATISFACTION OF THE CITY ENGINEER.
36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE
CITY ENGINEER.
BASIS OF BEARING:
BASIS OF BEARINGS FOR THIS SURVEY IS THE CENTERLINE OF
ALDER AVENUE AS SHOWN ON TRACT MAP NO. 3740 BOOK 48
PAGE 94 THROUGH 95.
BEING: N00°01'36"E
LEGAL DESCRIPTION:
THE WEST 160 FEET OF THE NORTH 330 FEET OF THE WEST HALF
OF LOT 430 ACCORDING TO MAP SHOWING SUBDIVISION OF LANDS
BELONGING TO THE SEMI TROPIC LAND AND WATER COMPANY, IN
THE COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA, AS PER
PLAN RECORDED IN BOOK 11 OF MAP, PAGE 12 OF MAPS,
RECORDS OF SAID COUNTY.
BENCHMARK:
THE BENCHMARK FOR THIS SURVEY IS SAN BERNADINO COUNTY
BENCH MARK NO.7-9 LOCATED ON THE ECR OF THE NORTHEAST
CURB RETURN AT INT FOOTHILL AND LOCUST ELEV=1307.15
OWNER:
TMIC GROUP
DBA ROUTE 66 PIT CENTER
12223 HIGHLAND AVENUE
RANCHO CUCAMONGA, CA. 91739
T�ITf�R�L�F�R1T
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV.
REVISION DESCRIP11ON
STREET IMPROVEMENT PLAN
17725 FOOTHILL BLVD.
S/E CORNER OF ALDER, AVE AND FOOTHILL BLVD.
0
F[? LFG A
! lP,: � Tam '111CCr E �'TF
A) uvr E-00TIll ,f. Al[)Eil, PR -
(7740/677767
R -=10/(x,' 76I Dow (! 7 1
[oil
31
X (1313.5) (1313.5) (1313.5) (1313.4)
1-
(1312.5)
••1 i a t.
Trees
0
x(13123)
I
11
PAI VA ,� \
! °M t 1"t
cal
MU
w go
,qm
.WN: 6L
U V
ck
• ' 1_I�'It ��I�!i
.»'su�ra*lstx•.�...-�aarrsa��•,�er .ear�ne..Wa c
Ilr��r+��
i' ►tet -- - - -1;, . •. '' �_ X1;1
wi�l
l3of a& M0 0211 �41
1306.3) ..
U-4-&-01 1-33
.. .
1307.11. 1305.5)
�►
..
HOLD HARMLESS AND INDEMNIFICATION CLAUSE:
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT , INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY ; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER ,THE
CITY OF FONTANA AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY REAL OR ALLEGED , IN CONNECTION WITH THE
PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY
ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER, THE CITY OF
FONTANA OR THE DESIGN ENGINEER.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE
PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, AND TO THE BEST OF OUR KNOWLEDGE,
THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS
REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER
LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF
AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL BE MADE TO APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR
FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS THE CITY, ITS EMPLOYEES, AND AGENTS
FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK
ON THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD
CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND
SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED.
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
DATE j ENGR. I CITY j DATE STANDARDS IN EFFECT.
SEAL:
mlm.; 1-01 `3179 •
N0. C68689
Exp. 9130111
,,C IV ��-
X (1
(1312.4)
X (1311.6)
X(1310.5)
X(1308.3)
11
X(1306.4)
11
LEGEND:
X(1312 4) X(1312.3)
(1312.9)•
X Conc.
1313.:
X (1312.5)
X(1312.4)
X (1311.5) \
SdAL&cAolr-- 40'
40 80< 120
X(1307.3)
FS
FINISH SURFACE
TC
TOP OF CURB
ro "10 lilliam
FLOW LINE
BW
BACK OF WALK
I 1
TOP OF GRATE
TP
TOP OF PAVEMENT
10-f 00 00 AZD� i
TOP OF WALL
TS
TRAFFIC SIGNAL
AC
A is
11±990
oll�,.,
WATER VALVE
CO
CLEAN OUT
PP
POWER POLE
PB
PULL BOX
STLT
STREET LIGHT
CB
CATCH BASIN
DI
DROP INLET
W
WATER
S
SEWER
E
ELECTRIC
G
GAS
PROJECT
SITE
0
�
o
VIE; IM
v
MERRILL
AVENUE
SAN BERNA RZ
INO (10) FREEWAY
�S:!�
-^a3,:.._
nfil♦ � M_►Jni3i3RtJ
[oil
31
X (1313.5) (1313.5) (1313.5) (1313.4)
1-
(1312.5)
••1 i a t.
Trees
0
x(13123)
I
11
PAI VA ,� \
! °M t 1"t
cal
MU
w go
,qm
.WN: 6L
U V
ck
• ' 1_I�'It ��I�!i
.»'su�ra*lstx•.�...-�aarrsa��•,�er .ear�ne..Wa c
Ilr��r+��
i' ►tet -- - - -1;, . •. '' �_ X1;1
wi�l
l3of a& M0 0211 �41
1306.3) ..
U-4-&-01 1-33
.. .
1307.11. 1305.5)
�►
..
HOLD HARMLESS AND INDEMNIFICATION CLAUSE:
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION
OF THIS PROJECT , INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY ; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER ,THE
CITY OF FONTANA AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY REAL OR ALLEGED , IN CONNECTION WITH THE
PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY
ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER, THE CITY OF
FONTANA OR THE DESIGN ENGINEER.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE
PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, AND TO THE BEST OF OUR KNOWLEDGE,
THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS
REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER
LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF
AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL BE MADE TO APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR
FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS THE CITY, ITS EMPLOYEES, AND AGENTS
FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK
ON THIS PROJECT.
THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD
CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND
SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED.
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
DATE j ENGR. I CITY j DATE STANDARDS IN EFFECT.
SEAL:
mlm.; 1-01 `3179 •
N0. C68689
Exp. 9130111
,,C IV ��-
X (1
(1312.4)
X (1311.6)
X(1310.5)
X(1308.3)
11
X(1306.4)
11
LEGEND:
X(1312 4) X(1312.3)
(1312.9)•
X Conc.
1313.:
X (1312.5)
X(1312.4)
X (1311.5) \
SdAL&cAolr-- 40'
40 80< 120
X(1307.3)
FS
FINISH SURFACE
TC
TOP OF CURB
FL
FLOW LINE
BW
BACK OF WALK
TG
TOP OF GRATE
TP
TOP OF PAVEMENT
TW
TOP OF WALL
TS
TRAFFIC SIGNAL
AC
ASPHALT CONCRETE
WM
WATER METER
WV
WATER VALVE
CO
CLEAN OUT
PP
POWER POLE
PB
PULL BOX
STLT
STREET LIGHT
CB
CATCH BASIN
DI
DROP INLET
W
WATER
S
SEWER
E
ELECTRIC
G
GAS
160 1
R.Z. SERVICES
2111 E.BALL RD # 117
ANAHEIM, CA 92806
TEL: (909)576-0641 DRAWN BY:
A DESIGN -BUILD COMPANYKM
DESIGNED BY:
ARES 1,J_EjR THE SUPERVISION OF: KM
• �`� CHECKED BY:
RIZK
C.E. C68689 LIC. EXP. 09/30/2011 DATE ZR
VICINITY MAP
NO SCALE
SHEET INDEX
SHT. NO. DESCRIPTION
1 TITLE SHEET
2 SECTIONS AND DETAILS
3 OFF-SITE IMPROVEMENTS
UTILITIES NOTIFICATION LIST:
CITY OF ,FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-7610
THE GAS COMPANY -DISTRIBUTION FACILITIES
16231 VALLEY BLVD.
FONTANA, CA 92335
(909) 889-9711 OR (800) 422-4133
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909) 357-6231 (SO. OF MERRILL)
(909) 357-6223 (NO. OF MERRILL)
(800) 422-4133
GENERAL TELEPHONE COMPANY
245 N. MOUNTAIN VIEW AVENUE
POMONA, CA 91766
(213) 357-2257 OR (800) 422-4133
SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT
825 EAST THIRD STREET
SAN BERNARDINO, CA 92408
(909) 383-1665
PACIFIC TELEPHONE & TELEGRAPH COMPANY
3073 ADAMS STREET
RIVERSIDE, CA 92504
(714) 359-2585 OR (800) 422-4133
FONTANA WATER COMPANY
8440 NUEVO AVENUE
P.O. BOX 987
FONTANA, CA 92334
(909) 822-2201
UNDERGROUND SERVICE ALERT (USA)
(800) 227-2600 OR
(800) 422-4133 OR
811
CUP # 08-017
ASP # 08-022 WDID # 8 36C357193
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLAN
17725 FOOTHILL BOULEVARD SCALE:
S E COR. OF ALDER AVE & FOOTHILL BLVD. AS SHOWN
DATE:
TITLE 5HEET 12/12/09
APPRO ED BY: ( DRAWING NO.: 1
DATE:
CITY ENGINEER R.C.E. 51152 48583
FO0THILL (2 10) FREEWA Y
z
W BASE
LINE RD
W W
F001NILL
BL VD
Q Q
PROJECT
SITE
0
�
o
v
MERRILL
AVENUE
SAN BERNA RZ
INO (10) FREEWAY
VICINITY MAP
NO SCALE
SHEET INDEX
SHT. NO. DESCRIPTION
1 TITLE SHEET
2 SECTIONS AND DETAILS
3 OFF-SITE IMPROVEMENTS
UTILITIES NOTIFICATION LIST:
CITY OF ,FONTANA
8353 SIERRA AVENUE
FONTANA, CA 92335
(909) 350-7610
THE GAS COMPANY -DISTRIBUTION FACILITIES
16231 VALLEY BLVD.
FONTANA, CA 92335
(909) 889-9711 OR (800) 422-4133
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909) 357-6231 (SO. OF MERRILL)
(909) 357-6223 (NO. OF MERRILL)
(800) 422-4133
GENERAL TELEPHONE COMPANY
245 N. MOUNTAIN VIEW AVENUE
POMONA, CA 91766
(213) 357-2257 OR (800) 422-4133
SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT
825 EAST THIRD STREET
SAN BERNARDINO, CA 92408
(909) 383-1665
PACIFIC TELEPHONE & TELEGRAPH COMPANY
3073 ADAMS STREET
RIVERSIDE, CA 92504
(714) 359-2585 OR (800) 422-4133
FONTANA WATER COMPANY
8440 NUEVO AVENUE
P.O. BOX 987
FONTANA, CA 92334
(909) 822-2201
UNDERGROUND SERVICE ALERT (USA)
(800) 227-2600 OR
(800) 422-4133 OR
811
CUP # 08-017
ASP # 08-022 WDID # 8 36C357193
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLAN
17725 FOOTHILL BOULEVARD SCALE:
S E COR. OF ALDER AVE & FOOTHILL BLVD. AS SHOWN
DATE:
TITLE 5HEET 12/12/09
APPRO ED BY: ( DRAWING NO.: 1
DATE:
CITY ENGINEER R.C.E. 51152 48583
��:a
3
-_ -_ E 'gip