HomeMy WebLinkAbout4858-1GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE OTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. CURVE DATA REFERS TO THE FACE OF CURB. 14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY OF FONTANA STANDARD DETAILS. 26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING. 32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF ROUGH GRADING. 33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. 36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. BASIS OF BEARING: BASIS OF BEARINGS FOR THIS SURVEY IS THE CENTERLINE OF ALDER AVENUE AS SHOWN ON TRACT MAP NO. 3740 BOOK 48 PAGE 94 THROUGH 95. BEING: N00°01'36"E LEGAL DESCRIPTION: THE WEST 160 FEET OF THE NORTH 330 FEET OF THE WEST HALF OF LOT 430 ACCORDING TO MAP SHOWING SUBDIVISION OF LANDS BELONGING TO THE SEMI TROPIC LAND AND WATER COMPANY, IN THE COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA, AS PER PLAN RECORDED IN BOOK 11 OF MAP, PAGE 12 OF MAPS, RECORDS OF SAID COUNTY. BENCHMARK: THE BENCHMARK FOR THIS SURVEY IS SAN BERNADINO COUNTY BENCH MARK NO.7-9 LOCATED ON THE ECR OF THE NORTHEAST CURB RETURN AT INT FOOTHILL AND LOCUST ELEV=1307.15 OWNER: TMIC GROUP DBA ROUTE 66 PIT CENTER 12223 HIGHLAND AVENUE RANCHO CUCAMONGA, CA. 91739 T�ITf�R�L�F�R1T TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIP11ON STREET IMPROVEMENT PLAN 17725 FOOTHILL BLVD. S/E CORNER OF ALDER, AVE AND FOOTHILL BLVD. 0 F[? LFG A ! lP,: � Tam '111CCr E �'TF A) uvr E-00TIll ,f. Al[)Eil, PR - (7740/677767 R -=10/(x,' 76I Dow (! 7 1 [oil 31 X (1313.5) (1313.5) (1313.5) (1313.4) 1- (1312.5) ••1 i a t. Trees 0 x(13123) I 11 PAI VA ,� \ ! °M t 1"t cal MU w go ,qm .WN: 6L U V ck • ' 1_I�'It ��I�!i .»'su�ra*lstx•.�...-�aarrsa��•,�er .ear�ne..Wa c Ilr��r+�� i' ►tet -- - - -1;, . •. '' �_ X1;1 wi�l l3of a& M0 0211 �41 1306.3) .. U-4-&-01 1-33 .. . 1307.11. 1305.5) �► .. HOLD HARMLESS AND INDEMNIFICATION CLAUSE: CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT , INCLUDING SAFETY OF ALL PERSONS AND PROPERTY ; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER ,THE CITY OF FONTANA AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY REAL OR ALLEGED , IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER, THE CITY OF FONTANA OR THE DESIGN ENGINEER. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, AND TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS THE CITY, ITS EMPLOYEES, AND AGENTS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH DATE j ENGR. I CITY j DATE STANDARDS IN EFFECT. SEAL: mlm.; 1-01 `3179 • N0. C68689 Exp. 9130111 ,,C IV ��- X (1 (1312.4) X (1311.6) X(1310.5) X(1308.3) 11 X(1306.4) 11 LEGEND: X(1312 4) X(1312.3) (1312.9)• X Conc. 1313.: X (1312.5) X(1312.4) X (1311.5) \ SdAL&cAolr-- 40' 40 80< 120 X(1307.3) FS FINISH SURFACE TC TOP OF CURB ro "10 lilliam FLOW LINE BW BACK OF WALK I 1 TOP OF GRATE TP TOP OF PAVEMENT 10-f 00 00 AZD� i TOP OF WALL TS TRAFFIC SIGNAL AC A is 11±990 oll�,., WATER VALVE CO CLEAN OUT PP POWER POLE PB PULL BOX STLT STREET LIGHT CB CATCH BASIN DI DROP INLET W WATER S SEWER E ELECTRIC G GAS PROJECT SITE 0 � o VIE; IM v MERRILL AVENUE SAN BERNA RZ INO (10) FREEWAY �S:!� -^a3,:.._ nfil♦ � M_►Jni3i3RtJ [oil 31 X (1313.5) (1313.5) (1313.5) (1313.4) 1- (1312.5) ••1 i a t. Trees 0 x(13123) I 11 PAI VA ,� \ ! °M t 1"t cal MU w go ,qm .WN: 6L U V ck • ' 1_I�'It ��I�!i .»'su�ra*lstx•.�...-�aarrsa��•,�er .ear�ne..Wa c Ilr��r+�� i' ►tet -- - - -1;, . •. '' �_ X1;1 wi�l l3of a& M0 0211 �41 1306.3) .. U-4-&-01 1-33 .. . 1307.11. 1305.5) �► .. HOLD HARMLESS AND INDEMNIFICATION CLAUSE: CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT , INCLUDING SAFETY OF ALL PERSONS AND PROPERTY ; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER ,THE CITY OF FONTANA AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY REAL OR ALLEGED , IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER, THE CITY OF FONTANA OR THE DESIGN ENGINEER. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, AND TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF AND ANY DAMAGE TO THESE LINES OR STRUCTURES. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY, AND HOLD HARMLESS THE CITY, ITS EMPLOYEES, AND AGENTS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES NOT SO REPORTED AND RESOLVED. SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH DATE j ENGR. I CITY j DATE STANDARDS IN EFFECT. SEAL: mlm.; 1-01 `3179 • N0. C68689 Exp. 9130111 ,,C IV ��- X (1 (1312.4) X (1311.6) X(1310.5) X(1308.3) 11 X(1306.4) 11 LEGEND: X(1312 4) X(1312.3) (1312.9)• X Conc. 1313.: X (1312.5) X(1312.4) X (1311.5) \ SdAL&cAolr-- 40' 40 80< 120 X(1307.3) FS FINISH SURFACE TC TOP OF CURB FL FLOW LINE BW BACK OF WALK TG TOP OF GRATE TP TOP OF PAVEMENT TW TOP OF WALL TS TRAFFIC SIGNAL AC ASPHALT CONCRETE WM WATER METER WV WATER VALVE CO CLEAN OUT PP POWER POLE PB PULL BOX STLT STREET LIGHT CB CATCH BASIN DI DROP INLET W WATER S SEWER E ELECTRIC G GAS 160 1 R.Z. SERVICES 2111 E.BALL RD # 117 ANAHEIM, CA 92806 TEL: (909)576-0641 DRAWN BY: A DESIGN -BUILD COMPANYKM DESIGNED BY: ARES 1,J_EjR THE SUPERVISION OF: KM • �`� CHECKED BY: RIZK C.E. C68689 LIC. EXP. 09/30/2011 DATE ZR VICINITY MAP NO SCALE SHEET INDEX SHT. NO. DESCRIPTION 1 TITLE SHEET 2 SECTIONS AND DETAILS 3 OFF-SITE IMPROVEMENTS UTILITIES NOTIFICATION LIST: CITY OF ,FONTANA 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-7610 THE GAS COMPANY -DISTRIBUTION FACILITIES 16231 VALLEY BLVD. FONTANA, CA 92335 (909) 889-9711 OR (800) 422-4133 SOUTHERN CALIFORNIA EDISON COMPANY 7951 REDWOOD AVENUE FONTANA, CA 92336 (909) 357-6231 (SO. OF MERRILL) (909) 357-6223 (NO. OF MERRILL) (800) 422-4133 GENERAL TELEPHONE COMPANY 245 N. MOUNTAIN VIEW AVENUE POMONA, CA 91766 (213) 357-2257 OR (800) 422-4133 SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT 825 EAST THIRD STREET SAN BERNARDINO, CA 92408 (909) 383-1665 PACIFIC TELEPHONE & TELEGRAPH COMPANY 3073 ADAMS STREET RIVERSIDE, CA 92504 (714) 359-2585 OR (800) 422-4133 FONTANA WATER COMPANY 8440 NUEVO AVENUE P.O. BOX 987 FONTANA, CA 92334 (909) 822-2201 UNDERGROUND SERVICE ALERT (USA) (800) 227-2600 OR (800) 422-4133 OR 811 CUP # 08-017 ASP # 08-022 WDID # 8 36C357193 CITY OF FONTANA, CALIFORNIA STREET IMPROVEMENT PLAN 17725 FOOTHILL BOULEVARD SCALE: S E COR. OF ALDER AVE & FOOTHILL BLVD. AS SHOWN DATE: TITLE 5HEET 12/12/09 APPRO ED BY: ( DRAWING NO.: 1 DATE: CITY ENGINEER R.C.E. 51152 48583 FO0THILL (2 10) FREEWA Y z W BASE LINE RD W W F001NILL BL VD Q Q PROJECT SITE 0 � o v MERRILL AVENUE SAN BERNA RZ INO (10) FREEWAY VICINITY MAP NO SCALE SHEET INDEX SHT. NO. DESCRIPTION 1 TITLE SHEET 2 SECTIONS AND DETAILS 3 OFF-SITE IMPROVEMENTS UTILITIES NOTIFICATION LIST: CITY OF ,FONTANA 8353 SIERRA AVENUE FONTANA, CA 92335 (909) 350-7610 THE GAS COMPANY -DISTRIBUTION FACILITIES 16231 VALLEY BLVD. FONTANA, CA 92335 (909) 889-9711 OR (800) 422-4133 SOUTHERN CALIFORNIA EDISON COMPANY 7951 REDWOOD AVENUE FONTANA, CA 92336 (909) 357-6231 (SO. OF MERRILL) (909) 357-6223 (NO. OF MERRILL) (800) 422-4133 GENERAL TELEPHONE COMPANY 245 N. MOUNTAIN VIEW AVENUE POMONA, CA 91766 (213) 357-2257 OR (800) 422-4133 SAN BERNARDINO COUNTY FLOOD CONTROL DISTRICT 825 EAST THIRD STREET SAN BERNARDINO, CA 92408 (909) 383-1665 PACIFIC TELEPHONE & TELEGRAPH COMPANY 3073 ADAMS STREET RIVERSIDE, CA 92504 (714) 359-2585 OR (800) 422-4133 FONTANA WATER COMPANY 8440 NUEVO AVENUE P.O. BOX 987 FONTANA, CA 92334 (909) 822-2201 UNDERGROUND SERVICE ALERT (USA) (800) 227-2600 OR (800) 422-4133 OR 811 CUP # 08-017 ASP # 08-022 WDID # 8 36C357193 CITY OF FONTANA, CALIFORNIA STREET IMPROVEMENT PLAN 17725 FOOTHILL BOULEVARD SCALE: S E COR. OF ALDER AVE & FOOTHILL BLVD. AS SHOWN DATE: TITLE 5HEET 12/12/09 APPRO ED BY: ( DRAWING NO.: 1 DATE: CITY ENGINEER R.C.E. 51152 48583 ��:a 3 -_ -_ E 'gip