HomeMy WebLinkAbout3857-915M O 300 trim 04 O 12 L/2 (TYP.)---•� 330-C-23 (560-C-3250) CONCRETE 25 'mm (10) {TYPA ---3-15M (04) CIRCULAR TIES.. SEE NOTE 9 150 mm 6•} MIN .. CUT NO. 2CUT N0. I LINE 90° NO.T 2 150 mm CUT N( 6'} iW1N DETAIL "A". (SEE NOTE 10) SONO -TUBE. OR EQUAL. INTERIOR FORM CUT N0. P SAW THE TUBE AT AN ANGLE OF A/2 WITH THE TRANS- VERSE. PLANE: REVERSE ONE SECTION -AND TAPE BOTH SECTIONS TOGETHER FORMING THE DEFLECTION ANGLE A. CUT NO. 2= SAW THE TUBE LONGITUDINALLY REMOVING A STRIP 3.14 (DO -D -) WIDE ON THE SIDE OPPOSITE THE OPEN JOINT. . BEND THE ENDS OF -THE CUT TOGETHEW AND INSERT THE . TUBE IN THE PIPE. �-- INTERIOR SURFACE OF PIPE DETAIL "B" TYPICAL' JOINT FOR REINFORCED CONCRETE PIPE AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE CONCRETE -COLLAR FOR RCP .sTANaARDPLAN METRIC PUBLIC WORKS STANDARDSS INC., GREENSOOKC I 300 mm 12" HROUGH 1800 mm 72" 380 - 2 3 825 mm (330) TO 1425. mm (576) REV. 19W. USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SHEET i OF 2 5 SHEET 1 Of 2 j S_ U. � n d o SOUTHWEST CORNER OF CHERRY AVE. AND SUMMIT AVE. 101 CD C0 M 3 0 E 6 co ' Z a) ON THE NORTHWEST CORNER OF A 10 FOOT WIDE r ai CATCHBASIN 0.8 FOOT SOUTH OF CURB FACE. A STANDARD D L. T a o L_N o _j o 0 / 525 21 130 5 680 24.• NO 5 I/4 300 MITI {I21 1450 300 mm (129 100 mm (41 N b W R - NEW&& EXIST. PIPE Ln N N I 1� J \ mm' (I8) 300 mm (12 8) 125 mm t5 } 1425 57 240 91/4 N 1500 60 250 9 1/2 f rn 's CD 600 mm (24.) 300 mm 021 150 mm (64 FLOW p 1950 78 300 It 3/4 2100 84 320 121/2 ' oR 0 0 730 mm {301} 450 * mm (1811) 175 mm (70) o c /oma XIST`�, N � I I 0 0) N 900 nwn {361 450.mm (18') 225 mm {91 �_ v� -0 BASIS OF BEARINGS: LEGAL DESCRIPTION: FCo� pF � 0- 1050 mm (42' 450 mm (f82) 225 mm (9') i o BEARINGS ARE BASED ON THE WESTERLY LINE OF BEING A SUBDIVISION OF A PORTION OF THE SOUTHEAST 1/4 OF SECTION 14, AND A PORTION OF THE o j THE NORTHEAST QUARTER OF SECTION 23, TOWNSHIP NORTHEAST 1/4 OF SECTION 23, BOTH OF TOWNSHIP 1 NORTH, RANGE 6 WEST, SAN BERNARDINO -0 • ;.:• ;: to �I 1200 mm (4801 450 mm (f80) 250 mm (109 �" =' "' ;•. 1425 mm (571) 450 (I8') 250 mm (100) • + : ir�. 1600 mm (60' 525 mm (211 275 rnm (II•) 15M O 300. mm 1650 mm (66' 525 mm (21•) 275 mm (II•) (•4 O 120) 1800 mm (728} 600 mm (24. 300 mm (120} ---3-15M (04) CIRCULAR TIES.. SEE NOTE 9 150 mm 6•} MIN .. CUT NO. 2CUT N0. I LINE 90° NO.T 2 150 mm CUT N( 6'} iW1N DETAIL "A". (SEE NOTE 10) SONO -TUBE. OR EQUAL. INTERIOR FORM CUT N0. P SAW THE TUBE AT AN ANGLE OF A/2 WITH THE TRANS- VERSE. PLANE: REVERSE ONE SECTION -AND TAPE BOTH SECTIONS TOGETHER FORMING THE DEFLECTION ANGLE A. CUT NO. 2= SAW THE TUBE LONGITUDINALLY REMOVING A STRIP 3.14 (DO -D -) WIDE ON THE SIDE OPPOSITE THE OPEN JOINT. . BEND THE ENDS OF -THE CUT TOGETHEW AND INSERT THE . TUBE IN THE PIPE. �-- INTERIOR SURFACE OF PIPE DETAIL "B" TYPICAL' JOINT FOR REINFORCED CONCRETE PIPE AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE CONCRETE -COLLAR FOR RCP .sTANaARDPLAN METRIC PUBLIC WORKS STANDARDSS INC., GREENSOOKC I 300 mm 12" HROUGH 1800 mm 72" 380 - 2 3 825 mm (330) TO 1425. mm (576) REV. 19W. USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SHEET i OF 2 NOTES 1. A CONCRETE -.COLLAR .IS REQUIRED WHERE. THE CHANGE I -N .GRADE EXCEEDS 10 PERCENT. 2. FOR CURVE JOINTS (SEE DETAIL B. SHEET 1) IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE THAT IS GREATER THAN 25 mm COL. -BUT. IS LESS THAN 75 mm((34) A CONCRETE COVER IS REQUIRED IN ACCORDANCE WITH SUBSECTION 306-1.2.4 OF THE SSPWC. IF THE EXTREME ENDS OF THE PIPE LEAVE A CLEAR SPACE THAT IS EQUAL TO OR GREATER THAN 75 mm (31, BUT LESS THAN 150* mm (61). A CONCRETE COLLAR IS REQUIRED. IF THE CLEAR SPACE IS ' 150 mm (61 OR GREATER. A TRANSITION STRUCTURE IS REQUIRED. 3.. CONCRETE COLLAR SHALL NOT BE USED FOR A SIZE CHANGE ON THE MAIN- LINE. 4'. CONNECTOR PIPES A. - WHERE PIPES OF DIFFERENT DIAMETERS ARE JOINED WITH A CONCRETE COLLAR. L AND T SHALL BE THOSE OF THE LARGER PIPE.,`D=..DI OR D2, WHICHEVER IS GREATER. B: WHEN DI - I S EQUAL TO OR LESS THAN Cz . JOIN INVERTS AND WHEN DI AS GREATER THAN D2, JOIN SOFFITS. .5. FOR PIPE -'LARGER THAN 1800 mm (721) SPECIAL COLLAR DETAILS ARE REQUIRED. 6. FOR PIPE SIZE NOT LISTED USE NEXT SIZE LARGER. 7. REINFORCEMENT SHALL CONFORM TO ASTM A 615 M (A 615) GRADE 300(40). 8. WHERE REINFORCING IS REQUIRED THE DIAMETER OF THE CIRCULAR TIES SHALL BE D+(2X WALL THICKNESS) + T. 9. '-REINFORCING SHALL BE USED WHERE THE PIPE DIAMETER IS GREATER THAN 525 mm (211 AND ON ALL PIPES WHERE THE SPACES BETWEEN THE EXTREME OUTER ENDS IS 75 mien (3') OR LARGER. CIRCULAR TIES PIPE Dl AMETER N0. OF CIRCULAR TIES 525 mm* (21') OR LESS 3 600 mm (24') .TO 750: mm (300) 3 825 mm (330) TO 1425. mm (576) 4 1500 mm (60') TO 1800 mm (720) 5 WHERE THE SPACE BETWEEN PIPE ENDS EXCEEDS 75. mm (38). THE NUMBER OF CIRCULAR TIES SHALL BE INCREASED TO MAINTAIN AN APPROXIMATE SPACING OF 150 mm (61 O.C.. 10. WHERE THE PIPE IS 525 mm (210) OR LESS IN DIAMETER AN INTERIOR FORM OF UNSEALED SONO -TUBE OR EQUAL SHALL BE USED TO PROVIDE A SMOOTH INTERIOR JOINT. THE' PAPER FORM MAY BE LEFT IN PLACE (SEE DETAIL A). WHEN THE PIPE IS 600 mm (241 OR LARGER A- REMOVABLE INTERIOR 'FORM .SHALL BE USED OR THE' INTERIOR JOINT SHALL BE COMPLETELY FILLED WITH MORTAR AND NEATLY 'POINTED. It. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES.' IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT - REINFORCING BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN METRIC0- 380-2 SHEET 201=2 CONCRETE COLLAR FOR RCP .30 mm(12")THRO H ? "• 0UG 1800 mm 2 a N O O N .- I o FILED IN BOOK 250 OF MAPS, AT PAGES 48 THROUGH 66, INCLUSIVE, IN THE OFFICE OF THE COUNTY RECORDER OF SAN BERNARDINO COUNTY, BEING NORTH 00030'24" WEST. STANDARDMEMIC LAN a E m 'M ° U N DESCRIBED BY METROPOLITAN WATER DISTRICT SO. I CALIFORNIA 1992 RANCHO CUCAMONGA, NEAR THE SHEET 1 Of 2 j S_ U. � n d o SOUTHWEST CORNER OF CHERRY AVE. AND SUMMIT AVE. 101 CD C0 M 3 0 E 6 co � Z a) ON THE NORTHWEST CORNER OF A 10 FOOT WIDE o ai CATCHBASIN 0.8 FOOT SOUTH OF CURB FACE. A STANDARD 300 12 110. 4 cfl CIO co o L_N o _j o 0 I 0 525 21 130 5 680 24.• NO 5 I/4 N \ (n I 825 33 160 6 1/4 ~900 36 170 6 1/2 Ln N N I v 0 - a 0 -- E E 'n \ O 1275 51' 220 81/2 13,5c) 1330 54 230 9, 1425 57 240 91/4 N 1500 60 250 9 1/2 1573 63 260 t0 rn 's CD 1729 69 280 10 3/4 1806. 72 280 1 It / ecv 1950 78 300 It 3/4 2100 84 320 121/2 _ 0 0 0 2400 96 360 14 Cn I a o c I c '-0 N � I I 0 0) N 0 �_ v� -0 BASIS OF BEARINGS: LEGAL DESCRIPTION: L � 0- i o BEARINGS ARE BASED ON THE WESTERLY LINE OF BEING A SUBDIVISION OF A PORTION OF THE SOUTHEAST 1/4 OF SECTION 14, AND A PORTION OF THE o j THE NORTHEAST QUARTER OF SECTION 23, TOWNSHIP NORTHEAST 1/4 OF SECTION 23, BOTH OF TOWNSHIP 1 NORTH, RANGE 6 WEST, SAN BERNARDINO -0 1 NORTH, RANGE 6 WEST, SAN BERNARDINO MERIDIAN, �I Q"' AS SHOWN ON AMENDING MAP OF TRACT NO 13750 MERIDIAN, COUNTY OF SAN BERNARDINO. L_ ° °1` N O O N .- I o FILED IN BOOK 250 OF MAPS, AT PAGES 48 THROUGH 66, INCLUSIVE, IN THE OFFICE OF THE COUNTY RECORDER OF SAN BERNARDINO COUNTY, BEING NORTH 00030'24" WEST. STANDARDMEMIC LAN BENCH MARK: m 'M 0 N DESCRIBED BY METROPOLITAN WATER DISTRICT SO. N N CALIFORNIA 1992 RANCHO CUCAMONGA, NEAR THE SHEET 1 Of 2 j INTERSECTION OF SUMMIT AVE. AND CHERRY AVE. AT THE U. � N d o SOUTHWEST CORNER OF CHERRY AVE. AND SUMMIT AVE. 101 CD 45 FEET WEST OF THE CENTERLINE OF CHERRY AVE. AND 37 0 E 6 FEET SOUTH OF THE CENTERLINE OF SUMMIT AVE. SET FLUSH �I Z a) ON THE NORTHWEST CORNER OF A 10 FOOT WIDE 0 � '0 CATCHBASIN 0.8 FOOT SOUTH OF CURB FACE. A STANDARD 300 12 110. 4 0 MWDSC 3 INCH BRASS DISK STAMPED "33A 1992". co o L_N o _j NAVD 88 - 1508.56 (FEET) --- AAAAAAAAAA AI, TOLL FREE '"NEM"' 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. I REVISION DESCRIPTION X EC0RO DRP► W //\./G OWNER/DEVELOPER Centex Homes 1265 Corona Pointe Court Corona, CA 92879 Ph: (951) 279-3000 Fax: (951) 279-2100 DATE I ENGR. I CITY I DATE 01105111 SOIL ENGINEER ALBUS-KEEFE and ASSOC., INC 1011 N. ARMANDO STREET ANAHEIM, CA 92806 Ph: (714) 630-1626 Fax: (714) 630-1916 C LATERAL / CONNECTOR PIPE 10MO4.50 mm (93 OR @4018•) OC ROUND EDGES TO RADIUS v OF APPROXIMATE ID OF LATERAL. MAXIMUM 900 mm (36')- 0p A 8 B BARS---�. ,rd, I. MAIN LINE -� N O TABLE FOR DIMENSIONS AND BAR SIZES 02 F m N STANDARDMEMIC LAN STATION -J m 'M 0 STATION PT.- OR OR REV. i". SHEET 1 Of 2 USE NTH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 0 U. � B T 0 CC a 0 (mm) (INCHES) (mm) tINCHESI a 0 �- - ca 300 12 110. 4 L> 0 0 0 v a n - Y E 370 13 110 4 1!4 450 Is 120 4 1/2 i+► E n 525 21 130 5 680 24.• NO 5 I/4 675 27 140 S 1/2 750 30 160 6 825 33 160 6 1/4 ~900 36 170 6 1/2 975 39 [80 7 1050 42 190 71/2 v 0 - a 0 -- E E 'n 1125 45 200 7 3 /4 - 1200 413 210 e 1275 51' 220 81/2 13,5c) 1330 54 230 9, 1425 57 240 91/4 m E E 1500 60 250 9 1/2 1573 63 260 t0 1650 66 260 101/4 1729 69 280 10 3/4 1806. 72 280 1 It / ecv 1950 78 300 It 3/4 2100 84 320 121/2 2250 90 340 13 1/4 0 p 0 0 2400 96 360 14 2350 102 400 151/2 D BARS PLAN D BARS No OUND EDGES 0 75 mm (30) R MM, • `-STATION !OM (03 OR 04), SEE NOTE 4 IOM 03 OR •4) ELEV. ELEV. (� STA. STA. I 15Mo450 mm (•4a8•) OC. BOTH WAYS, TO BE USED WHEN 02 IS 1500 mm (60') OR MORE LONGITUDINAL SECTION D BARS A BARS F BARS--^ ! j fMO450 mm OR s4 8 BARS 18•) OC I V. R ELEV. S � 2700 lde Oro 16 �.� 7111 - T 2$50 114 420 16 1/2 "EE 10 15M0450 mm (040189) OC, ly 3004 120 440 17 E E E BOTH WAYS. IS1500mm (600) 3 5 126 440 17 M h o OR MORE aL 3300 132 Oso 17 1/2 i is 0 IL MAIN LINE 3450 138 450 171/2 in 2 3600 144 460 18 " N SECTION N' -N" --N`" PROJECTED ON M -M -N' IOM (03 OR •4) AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROF'tiKSST0�'TN6 TRANSITION STRUCTURE STANDARDMEMIC LAN rsut� �waxs srAr�aRns IN', aRErhoo19 2C ,YreE PIPE TO PIPE 340-1 REV. i". SHEET 1 Of 2 USE NTH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION Q�pFESS10y V. A71 W o. 16 _ �wlftpl oil I&D M %. ;_, /tt OF CAS\F� SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. NOTES I. THE HORIZONTAL ANGLE OF CONVERGENCE OR DIVERGENCE. 6. SHALL NOT EXCEED 5°45. 2. VALUES FOR A. B, C. DI AND D2 ARE SkOWN ON THE PROJECT DRAWINGS. ELEVATION R AND ELEVATIONS ARE SHOWN WHEN REQUIRED BY NOTE 10. 3. FLOOR OF STRUCTURE SHALL BE STEEL TROWELED TO SPRING LINE. 4. REINFORCEMENT STEEL SHALL CONFORM TO ASTM A 615 M (A 615)• GRADE 300(40). AND SHALL TERMINATE 40 mm (1 1/21 CLEAR OF CONCRETE SURFACES UNLESS OTHERWISE SHOWN. LONGITUDINAL BARS SHALL BE IOM 0 450 mm (03 OR 04 O 18') OC OR LESS. 5. ELEVATION S APPLIES AT INSIDE WALL OF STRUCTURE. 6. TRANSITION STRUCTURE SHALL BE POURED IN ONE CONTINUOUS OPERATION, EXCEPT THAT THE CONTRACTOR SHALL HAVE THE OPTION OF PLACING AT THE SPRING LINE A CONSTRUCTION JOINT LONGITUDINAL KEYWAY. 7. THE LENGTH OF THE STRUCTURE MAY BE INCREASED AT THE OPTION OF THE CONTRACTOR TO MEET RCP ENDS. USING D BARS. LONGITUDINAL AND BOTTOM REINFORCEMENT IN EXTENDED PORTION OF SAME .DIAMETER AND SPACING AS SPECIFIED IN THE TABLE, BUT ANY CHANGE IN THE LOCATION OF SPUR MUST BE APPROVED BY THE ENGINEER. • 11 8. EMBEDMENT P SHALL BE AS SPECIFIED IN THE TABLE. UNLESS OTHERWISE SHOWN ON THE PROJECT DRAWINGS. 9. WHEN THERE IS NO SPUR REQUIRED, A & B BARS SHALL BE OMITTED. 10. WHEN ELEVATION R AND ELEVATION S ARE NOT SHOWN ON PROJECT DRAWINGS. INLET PIPE SHALL ENTER MAIN LINE RADIALLY. WHEN INLET PIPE ENTERS MAIN LINE OTHER THAN RADIALLY, ELEVATION S SHALL BE SHOWN ON PROJECT DRAWINGS. AND INLET PIPE SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO CATCH BASIN OR GRADE BREAK IN INLET LINE. ELEVATION R SHALL BE SHOWN ON PROJECT DRAWINGS ONLY WHEN STUB IS TO BE PROVIDED IN MAIN LINE FOR FUTURE CONSTRUCTION OF INLET PIPE. 11. THE MAXIMUM COVER ABOVE THIS STRUCTURE SHALL BE 7.5 m (251. IF THE COVER EXCEEDS 7.5-m (259 A SPECIAL STRUCTURE SHALL BE DESIGNED FOR THE COVER AND DETAILED ON THE PROJECT DRAWINGS. 12. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES EXCEPT REINFORCING BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 340 - 1 SHEET2 OF 2 TRANSITION STRUCTUREMETRIC PIPE TO PIPE SEAL -ENGINEER CITY OF FO N TANA, CALIFORNIA Q�OFESSIONq!AEAS �c STORM DRAIN IMPROVEMENT PLANS ARIC M. TORREYSO E i �+ � I I\I E E P I r% l DRAWN BY: SCALE: No. 66068 937 SOUTH VIA LATA, SUITE 500 COLTON, CA 92324 O.S. AS SHOWN 06-30-0s '� PH. (909) 783-0101 FAX (909) 783-0108 DESIGNED BY- STAND LAN DETAILS DATE: Exp. D.J.D. �O: JANUARY, 2006 CIVIL PREPARED Y: ARIC M. TO ON R.C.E. N0. 66068 CHECKED BY. AP 0 -_D BY- DRAWING NO.: OF CA�-� EXP. D : 06- -06 710 DATE:14 Ir A.M.T. CM - Z CITY ENGINEER R.C.E. 51152 DATE: 3857 R