HomeMy WebLinkAbout3856-124. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V. C.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE Cl TY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 201, MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 0 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, 00 BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC N ENGINEER. 0 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 3 v BASIS OF BEARINGS. N BEARINGS ARE BASED ON THE WESTERLY UNE OF BEINGS LA SUBDIVISION OF A PORTION OF THE SOUTHEAST 1/4' OF SECTION 14, AND A POI THE NORTHEAST QUARTER OF SECTION 23, TOWNSHIP OF THE NORTHEAST 1/4 OF SECTION 23, BOTH OF TOWNSHIP 1 NORTH, RANG 6 WEST, ol 1 NORTH, RANGE 6 WEST, SAN BERNARDINO MERIDIAN, SAN BERNARDINO MERIDIAN, COUNTY OF SAN BERNARDINO. AS SHOWN ON AMENDING MAP OF TRACT NO. 13750, FILED IN BOOK 250 OF MAPS, AT PAGES 48 THROUGH v 66, INCLUSIVE, IN THE OFFICE OF THE COUNTY 6" MAX SIZE ' NATIVE SOIL COMPACTED 90% 8" VCP/DI 6" MIN 10" MAX 1 " MAX SIZE SELECTED NATIVE BEDDING COMPACTED TO 9 0% CITY OF FONTANA TRACT MAP NO. 16290-2 SEWER IMPROVEMENT PLANS SOUTH & WEST R/W ,12' X1.0"/0.5' S 6.56 68'/64'/60' ' 144'140'130' 22'/20'/18' 1 22'/20'/18' NORTH & EAST R/W 12' � 6.5 5' *6 0.5'/'1.0" ' Z. �� I 2.0% 2.070 I �_ ' 5' 6' PROP. 8 WTRCURB & SEE STREET IMPROVEMENT PROP. , 7 GUTTER PLANS FOR LOCATION 8 " SWR. PROP. STORM DRAIN TABLE. 200-1.2 [A] SIEVE SIZE GENERAL NOTES 1 112- 4: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, 3/4" 100 112" THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 3/8" 20-60 NO. 4 ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION NO. 8 0-5 ASTM C 131 UNLESS OTHERWISE NOTED. TEST GRADING 8353 SIERRA AVE. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE FEET WEST OF THE CENTERLINE OF CHERRY AVE. AND 37 O4 REMOVE TEMP. END PLUG AND JOIN PROP. SEWER. RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR EA O5 N SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. DIAL TWO WORKING I co 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. TELEPHONE. (909) 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT YOU DIG YOU D I G O7 REMOVE EXIST. CLEANOUT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION EA O MWDSC 3 INCH BRASS DISK STAMPED '33A 1992'. SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN SF O to N PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. A PURL I C SERVICE BY UNDERGROUND SERVICE ALERT 428-8407 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES 1 o INSTALL LOCKING TYPE MANHOLE FRAME AND COVER DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC P/L ATTENTION: PER A. P. W.A. STD. 210-2 PER DETAIL ON SHE 11. EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. VARIES 16071 MOJAVE DR. BLDG. B 6. /T SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS SEWER EASEMENT VI CTORVI LLE, CA 92392 OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. VARIES 30'-40' 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCA VA TION OR TRENCH WORK FOR �? LEWIS MCDONALD TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL 1500 S. AUTO CENTER DRIVE TELEPHONE: (909) SAFETY. ONTARIO, CA 91761 8. THE WALLS AND FACES OF ALL EXCA VA TIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE �f GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, PROP. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, 8" SWR. THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND TYPICAL SECTION -OFFSITE SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING,' N.T.S. BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 3' MAX SIZE NATIVE 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT SOIL COMPACTED 95% APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 6" MIN 6" MIN 14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE 10" MAX 10 MAX CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE - - - - - RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING �v DURING CONSTRUCTION. 15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH 1 " MAX SIZE MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 6" MAX SIZE SELECTED NATIVE 16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, NATIVE SOIL BEDDING COMPACTED TO 90% MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR COMPACTED 90% LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK z PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER `\ _ REPLACEMENT OF THE MONUMENT. 17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. U o A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR' cl o RESIDENTS AND EMERGENCY VEHICLES. 8" VCP/DIP 18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, lt� INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITEDT PUBLICRR�PPROVALADJACENT TO THE RIGHT OF WAY DURING TYPICAL BEDDING FOR 8" VCP/DIP CONSTRUCTION WITHOUT PRIORWRITTEN. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. LESS THAN 10' DEEP �21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE N.T.S. SPECIFIED DENSITY IS OBTAINED. 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH 3' MAX SIZE NATIVE EXISTING CONCRETE SOIL COMPACTED 95% 24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V. C.P. 26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE Cl TY ENGINEER. 27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 201, MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 0 37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, 00 BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC N ENGINEER. 0 38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 3 v BASIS OF BEARINGS. N BEARINGS ARE BASED ON THE WESTERLY UNE OF BEINGS LA SUBDIVISION OF A PORTION OF THE SOUTHEAST 1/4' OF SECTION 14, AND A POI THE NORTHEAST QUARTER OF SECTION 23, TOWNSHIP OF THE NORTHEAST 1/4 OF SECTION 23, BOTH OF TOWNSHIP 1 NORTH, RANG 6 WEST, ol 1 NORTH, RANGE 6 WEST, SAN BERNARDINO MERIDIAN, SAN BERNARDINO MERIDIAN, COUNTY OF SAN BERNARDINO. AS SHOWN ON AMENDING MAP OF TRACT NO. 13750, FILED IN BOOK 250 OF MAPS, AT PAGES 48 THROUGH v 66, INCLUSIVE, IN THE OFFICE OF THE COUNTY 6" MAX SIZE ' NATIVE SOIL COMPACTED 90% 8" VCP/DI 6" MIN 10" MAX 1 " MAX SIZE SELECTED NATIVE BEDDING COMPACTED TO 9 0% CITY OF FONTANA TRACT MAP NO. 16290-2 SEWER IMPROVEMENT PLANS SOUTH & WEST R/W ,12' X1.0"/0.5' S 6.56 68'/64'/60' ' 144'140'130' 22'/20'/18' 1 22'/20'/18' NORTH & EAST R/W 12' � 6.5 5' *6 0.5'/'1.0" ' Z. �� I 2.0% 2.070 I �_ ' 5' 6' PROP. 8 WTRCURB & SEE STREET IMPROVEMENT PROP. , 7 GUTTER PLANS FOR LOCATION 8 " SWR. PROP. STORM DRAIN TABLE. 200-1.2 [A] SIEVE SIZE PERCENTAGE PASSING SIEVES 1 112- 4: 1" - 3/4" 100 112" 90-100 3/8" 20-60 NO. 4 0-15 NO. 8 0-5 ASTM C 131 B TEST GRADING 8353 SIERRA AVE. vl 1 /2" CRUSHED STONE BEDDING PER STD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A] SHOWN TYPICAL BEDDING FOR 8 " VCP/DIP 10' OR DEEPER N.T.S. /A C(�ij,�,�t�`� h� �1 m o. 1983- m 'XP RECORDER OF SAN BERNARDINO COUNTY, CIVI\- J BEING NORTH 0930'24' WEST. �c , 3 BENCH MARK: REV. REVISION DESCRIPTI Im DESCRIBED BY METROPOLITAN WATER DISTRICT SO. A O LON TSAI 4: BEDDING PER DETAIL HEREON. CALIFORNIA 1992 RANCHO CUCAMONGA, NEAR THE LF 2O CONSTRUCT 48" DIA. ECCENTRIC MANHOLE PER RIALTO, CA 92377 MAVENWOOD PLACE STA. 7+74.97 TO STA. 14+07.90 SHEET INTERSECTION OF SUMMIT AVE. AND CHERRY AVE. AT THE 27 i SOUTHWEST CORNER OF CHERRY .AVE. AND SUMMIT AVE. 101 0 WREN 9: 8353 SIERRA AVE. CITY OF FONTANA STD. NO.125 AND NO.125B, IN LANDSCAPE AREAS. (127 EA) N FEET WEST OF THE CENTERLINE OF CHERRY AVE. AND 37 O4 REMOVE TEMP. END PLUG AND JOIN PROP. SEWER. 2 EA O5 N FEET SOUTH OF THE CENTERLINE OF SUMMIT AVE. SET FLUSH DIAL TWO WORKING I co ON THE NORTHWEST CORNER OF A 10 FOOT WIDE BEFORE DAYS BEFORE I TELEPHONE. (909) BEDDING PER DETAIL HEREON. CATCHBASIN 0.8 FOOT SOUTH OF CURB FACE. A STANDARD YOU DIG YOU D I G O7 REMOVE EXIST. CLEANOUT 1 EA O MWDSC 3 INCH BRASS DISK STAMPED '33A 1992'. TOLL FREE 1-800-227-2600 SF O to N NAVD 88 -1508.56 (FEET A PURL I C SERVICE BY UNDERGROUND SERVICE ALERT 428-8407 CITY OF FONTANA STD. NO. 112. FONTANA, CA 92335 1 o INSTALL LOCKING TYPE MANHOLE FRAME AND COVER 5 O ATTENTION: PER A. P. W.A. STD. 210-2 PER DETAIL ON SHE 11. ANGUSTAIN W/n/ G OWNER/DEVELOPER I SOIL ENGINEER Centex Homes ALBUS-KEEFE and ASSOC., INC. 1265 Corona Pointe Court 1011 N. ARMANDO STREET Corona, CA 92879 ANAHEIM, CA 92806 Ph. (951) 279-3000 Ph: (714) 630-1626 Fax (951) 279-2100 Fax. (714) 630 1916 DATE I ENGR. I CITY I DATE 0//0s// TYPICAL STREET SECTION N.T.S. SEWER ES77MATE OF OUAAMES QUAN'RIIES Oi CONSTRUCT 8" EXTRA STRENGTH VCP SEWER LINE, ATTENTION: LON TSAI 4: BEDDING PER DETAIL HEREON. 5,471 LF 2O CONSTRUCT 48" DIA. ECCENTRIC MANHOLE PER RIALTO, CA 92377 MAVENWOOD PLACE STA. 7+74.97 TO STA. 14+07.90 SHEET CITY OF FONTANA STD. NO. 112. 27 EA O3 CONSTRUCT 4" SEWER LATERAL AND HOUSE CLEANOUT PER WREN 9: 8353 SIERRA AVE. CITY OF FONTANA STD. NO.125 AND NO.125B, IN LANDSCAPE AREAS. (127 EA) 4,315 LF O4 REMOVE TEMP. END PLUG AND JOIN PROP. SEWER. 2 EA O5 INSTALL BACKWATER DEVICE. 70 EA Os CONSTRUCT 8" DUCTILE IRON PIPE SEWER LINE, 800 W. CIENEGA AVE. TELEPHONE. (909) BEDDING PER DETAIL HEREON. 1,160 LF O7 REMOVE EXIST. CLEANOUT 1 EA O SAWCUT/REMOVE AND REPLACE EXIST. DRIVEWAY (46 LF) 183 SF O CONSTRUCT 6.0" DIA. ECCENTRIC MANHOLE PER 4 EA 428-8407 CITY OF FONTANA STD. NO. 112. FONTANA, CA 92335 1 o INSTALL LOCKING TYPE MANHOLE FRAME AND COVER 5 EA ATTENTION: PER A. P. W.A. STD. 210-2 PER DETAIL ON SHE 11. ANGUSTAIN 16071 MOJAVE DR. BLDG. B SEWER LEGEND (760) 245-0330 SEWER MAIN LINE -¢- SEWER MANHOLE SEWER LINE WITH LATERALS BW BACKWATER DEVICE UTiLIIY PURVEYORS WATER WEST VALLEY WATER DISTRICT ATTENTION: LON TSAI 4: 855 W. BASELINE TELEPHONE. (909) 875-1804 SHEET RIALTO, CA 92377 MAVENWOOD PLACE STA. 7+74.97 TO STA. 14+07.90 SHEET 7: SEWER CITY OF FONTANA ATTENTION: BRIAN WREN 9: 8353 SIERRA AVE. TELEPHONE: (909) 350-6632 SHEET FONTANA, CA 92335 OFFSITE SEWER STA. 9+89.31 TO STA. 11+53.55 SHEET 12: ELECTRIC SOUTHERN CALIFORNIA EDISON COMPANY ATTENTION: JEFF BURT 800 W. CIENEGA AVE. TELEPHONE. (909) 592-3737 SAN DIMAS, CA 91773 GAS SOUTHERN CALIFORNIA GAS COMPANY ATTENTION: STEVE ROBLES 16231 VALLEY BLVD. TELEPHONE: (909) 428-8407 FONTANA, CA 92335 TELEPHONE VERIZON ATTENTION: FRANK ANGUSTAIN 16071 MOJAVE DR. BLDG. B TELEPHONE. (760) 245-0330 VI CTORVI LLE, CA 92392 CABLE ADELPHIA COMMUNICATIONS ATTENTION: LEWIS MCDONALD 1500 S. AUTO CENTER DRIVE TELEPHONE: (909) 975-3343 ONTARIO, CA 91761 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. SEAL -ENGINEER o QROF ESS/0 - C� rn W o% NO. C041983 EXP. 3/31/06 s� CN IL �P ATF OF CAS\F�� EXP. SITE LOCATION COYOTE CANYON ROAD DUNGAN CANYON ROAD � ROADRUNNER ROAD CHERRY AVENUE / C?�P RYTLE CREEK SUMMIT DUNCAN CANYON AVENUE ROAD � / wciin MAa N.T.S EnrcrNEEa s NO"nCE To CON7RACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND OR OVERHEAD UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE APPROXIMATE. THE ENGINEER ASSUMES NO LIABILITY AS TO THE EXACT LOCATION OF SAID LINES NOR FOR UTILITIES OR IRRIGATION LINES WHOSE LOCATION ARE NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL UTILITY AND IRRIGATION COMPANIES PRIOR TO WORK TO ACCURATELY IDENTIFY THESE LOCATIONS, WHETHER OR NOT SHOWN HEREON, AND IS RESPONSIBLE FOR ANY DAMAGE OR PROTECTION OF THESE LINES. PHASED UTILITY RELOCATIONS MAY BE NECESSARY AND SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CLOSELY COORDINATE HIS ACTIVITIES WITH THOSE OF ALL UTILITY COMPANIES. THE CONTRACTOR SHALL CALL IN A LOCATION REQUEST TO UNDERGROUND SERVICE ALERT (U.S.A.) PHONE 1-800-227-2600 TWO (2) WORKING DAYS PRIOR TO DIGGING. NO CONSTRUCTION PERMIT ISSUED BY PUBLIC WORKS DEPARTMENT SHALL BE VALID INVOLVING UNDERGROUND FACILITIES UNLESS THE APPLICANT HAS AN INQUIRY IDENTIFICATION NUMBER ISSUED BY U.S.A. THE ESTIMATED QUANTITY FOR EACH SPECIFIC ITEM OF THE WORK DESIGNATED ON THE PLANS SHALL BE CONSIDERED AS APPROXIMATE ONLY AND NO GUARANTEE IS MADE THAT THE QUANTITIES WHICH CAN BE DETERMINED BY COMPUTATIONS, BASED ON THE DETAILS AND DIMENSIONS SHOWN ON THE PLANS, WILL EQUAL THE ESTIMATED QUANTITIES. THE ESTIMATE OF QUANTITIES IS PROVIDED BY THE ENGINEER ONLY FOR THE CONVENIENCE OF THE OWNER, THE CONTRACTOR SHALL MAKE HIS OWN DETERMINATION AND BE RESPONSIBLE FOR HIS OWN CONSTRUCTION QUANTITIES BEFORE SUBMITTING A BID. ANY ITEM OF WORK, OR PORTION THEREOF, REQUIRED BY THESE PLANS WHICH IS NOT SPECIFICALLY LISTED IN THE ESTIMATE OF QUANTITIES SHALL BE CONSIDERED AS INCLUDED IN THE OTHER ITEMS OF WORK. UPON FINAL DESIGN OF THE INTERIOR PLUMBING SYSTEM FOR EACH LOT, CONTRACTOR IS TO DETERMINE WHICH LOTS WILL REQUIRE BACKWATER VALVES IN ACCORDANCE WITH SECTION 710.1 OF THE UNIFORM PLUMBING CODE. BACKWATER VALVES AS NOTED ON THESE PLANS. WERE LOCATED IN RESPECT TO PAD ELEVATION, IN LIEU OF FLOOD RIM ELEVATION OF LOWEST FIXTURE, VERSUS NEXT UPSTREAM TOP OF RIM ELEVATION OF MANHOLE. TOP AND BOTTOM ELEVATION CALLOUT FOR ALL PROPOSED OR EXISTING UTILITIES AND FACILITIES SHOWN ON THESE PLANS ARE APPROXIMATE. WALL THICKNESSES FOR ALL UTILITIES AND FACILITIES PROPOSED OR EXISTING BY INSTALLING CONTRACTOR MAY VARY DUE TO MANUFACTURER'S TYPE, USE AND SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL EXISTING AND PROPOSED UTILITY AND FACILITY CROSSING LOCATIONS SHOWN ON THESE PLAN PRIOR TO INSTALLATION TO INSURE THE TYPE OF MATERIAL HE HAS CHOSEN MEETS THE MINIMUM SEPARATION REQUIREMENTS OF CITY OF FONTANA. ERNATE ENGINEER NOTE CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. srEEr INDEX SHEET 1: TITLE SHEET/VICINITY MAP/GENERAL NOTES SHEET 2: INDEX MAP SHEET 3: BOBCAT WAY STA. 9+95.00 TO STA. 13+19.00 AEI-ICASC 937 SOUTH VIA LATA DRAWN BY: SUITE 500 OS COLTON, CA 92324 DESIGNED BY: PH. (909) 783-0101 FAX 909 783-0108 OS RE Y. CHRIS D. NS R. C. E. NO. 41983 TE: /06 CHECKED BY: DATE: L1D' 1) (0 gQ SBC/JGS , f . jA0 CITY OF FONTANA, CALIFORNIA COYOTE CANYON TRACT 16290-2 SEWER IIVIPROVEME PLANS SCALE: AS SHOWN ABOVE DATE: ,4E ET OCTOBER, 2005 APP OVED BDRAWING NO.: TY ENGINEER R.C.E. 51152 DATE: 3856 12 LA SARRE DRIVE STA. 14+33.55 TO STA. 17+39.30 SHEET 4: THORNBUSH WAY STA. 12+34.72 TO STA. 18+35.98 SHEET 5: BROOKSIDE AVENUE STA. 20+80.11 TO STA. 28+53.83 SHEET 6: MAVENWOOD PLACE STA. 7+74.97 TO STA. 14+07.90 SHEET 7: WESTFORK LANE STA. 9+92.55 TO STA. 15+76.35 SHEET 8: SAGEGROVE LANE STA. 10+07.47 TO STA. 14+84.00 SHEET 9: THORNBERRY WAY STA. 9+95.00 TO STA. 19+82.27 SHEET 10: BROOKSIDE AVENUE STA. 9+27.11 TO STA. 19+18.03 SHEET 11: OFFSITE SEWER STA. 9+89.31 TO STA. 11+53.55 SHEET 12: OFFSITE SEWER STA. 11+53.55 TO STA. 21+72.39 AEI-ICASC 937 SOUTH VIA LATA DRAWN BY: SUITE 500 OS COLTON, CA 92324 DESIGNED BY: PH. (909) 783-0101 FAX 909 783-0108 OS RE Y. CHRIS D. NS R. C. E. NO. 41983 TE: /06 CHECKED BY: DATE: L1D' 1) (0 gQ SBC/JGS , f . jA0 CITY OF FONTANA, CALIFORNIA COYOTE CANYON TRACT 16290-2 SEWER IIVIPROVEME PLANS SCALE: AS SHOWN ABOVE DATE: ,4E ET OCTOBER, 2005 APP OVED BDRAWING NO.: TY ENGINEER R.C.E. 51152 DATE: 3856 12