Loading...
HomeMy WebLinkAbout4882-1CITY OF FONTANA GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK," THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. CURVE DATA REFERS TO THE FACE OF CURB. 14. STATIONING REFERS TO THE CENTERLINE OF STREETS EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE CITY TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM OF TWO 12 -FOOT LANES SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 21. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 22. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS - BENCH MARK: BM #118 FOUND "X" ON EAST END OF SOUTHEAST CURB RETURN AT SEVILLE AVENUE AND SIERRA AVENUE. ELEV. = 1286.36' BASIS OF BEARINGS: BEARINGS ARE BASED ON THE CENTERLINE OF SEVILLE AVE. AS N89'44'00"E BETWEEN WHEELER ST. AND EMERALD AVE. PER CITY DWG. NO 1404 CITY OF FONTANA GENERAL NOTES CONT'D STREET IMPROVEMENT SEVILLE AVEIN-UE LEGEND 0 25. THE FINAL LOCATION AND WIDTH OF DRIVEWAY APPROACH APRONS SHALL BE ------� APPROVED AT THE TIME OF CONSTRUCTION AND SHALL CONFORM TO THE CITY VALLEY OF FONTANA STANDARD DETAILS. FONTANA, 26. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND ATTN: FINISH TO MATCH EXISTING CONCRETE. (909) 27. THE CONTRACTOR SHALL STA Iva -,__N "S" IN THE FACE OF THE CURB AT END CURVE THE LOCATION OF THE SEWER LATERAL. \�, tltttllttltltltttltltllltltttltltll SOUTHERN CALIFORNIA EDISON COMPANY 28. NO CONCRETE S`I'-IALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL BW HAVE BEEN PLACED, INSPECTED AND APPROVED. CA 92335 ATTN: CB 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED ChLkFc PRIOR TO PAVING OF STREETS.. DI 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT EP PRIOR TO PLACEMENT. EPP 31. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO FL REVISION AND APPROVAL OF THE CITY ENGINEER AS DETERMINED BY SOILS FS TESTS TAKEN AFTER COMPLETION OF THE ROUGH GRADING. FG 32. ACTUAL THICKNESS OF A.C. PAVEMENT AND/OR BASE COURSE MATERIAL, FOR ICV STRUCTURAL STREET SECTIONS SHALL BE RECOMMENDED BY A GEOTECHNICAL ,, PL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF THE ROUGH GRADING. SMH TG 33. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RW RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. TC 34. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 35. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER. 36. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CITY OF FONTANA UTILITY NOTIFICATION LIST FONTANA WATER COMPANY 8440 NUEVO AVE FONTANA, CA 92335 (909) 822-2201 (909) 823-5046 FAX ATTN: AL KROHN PACIFIC BELL COMPANY 3939 E CORONADO ST ANAHEIM, CA 92807 (714) 666-5500 ATTN: LARRY SIGNAIGO COMCAST (CABLE TV) 1205 DUPONT AVE ONTARIO, CA 91761 (909) 390-4777 x3055 ATTN: JACK HAYES CITY OF FONTANA SEWER 8353 SIERRA AVE FONTANA, CA 92335 (909) 350-6632 SOUTHERN CALIFORNIA GAS COMPANY 16231 VALLEY BLVD FONTANA, CA 92335 ATTN: RICK REYER (909) 335-7508 END CURVE EMERGENCIES: (800) 427-2200 SOUTHERN CALIFORNIA EDISON COMPANY 7951 REDWOOD AVE FONTANA, CA 92335 ATTN: JAIME-AMESZCULA (909) 357-6581 (909) 820-5598 UNDERGROUND (909) 820-5137 TRANSMISSIONS (213) 637-1233 PIPELINES (909) 357-6589 DISTRIBUTION (800) 422-4133 UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." Underground Service Alert Call: 811 WWW.DIGALERT.COM TWO WORKING DAYS BEFORE YOU DIG REV REVISION. DESCRIPTION DATE' I ENGR. I CITY I DATE POWER POLE STREET LIGHT FIRE HYDRANT TREE BUSHES WALL - BLOCK OR CONCRETE BACK OF WALK CATCH BASIN CHAIN LINK FENCE DROP INLET EDGE OF PAVEMENT EXISTING POWER POLE FLOW LINE FINISHED SURFACE FINISHED GRADE IRRIGATION CONTROL VALVE PROPERTY LINE SEWER MANHOLE TOP OF GRATE RIGHT-OF-WAY TOP OF CURB PCC PAVING AC PAVING IX, PAVING COLDPLAN (1" THICK) EXIST. PAVING REMOVAL TR TOP OF RAIL WSBF WATER SERVICE BACKFLOW WV WATER VALVE WVLT WATER VAULT BC BEGIN CURVE EC END CURVE VC VERTICAL CURVE EG EXISTING GROUND SW SIDEWALK PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE AGENCY AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILTY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE AGENCY OR THE ENGINEER. SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. CONSTRUCTION NOTES: QUANTITY ESTIMATE FEE ESTIMATE USE ONLY 1O CONSTRUCT CURB AND GUTTER (8" CURB) PER CITY OF FONTANA STD. PLAN. 1000.--------------- 79 L.F. O CONSTRUCT CONCRETE SIDEWALK PER CITY OF FONTANA STD. PLAN NO. 1006. - - - - - - - - - - - - - - - 350 S.F. (D3CONSTRUCT 8" THICK PCC (560-C-3250) WITH 6" CRUSHED AGGREGATE BASE OVER 12" MIN. 95% - - - - - - - 466 S.F. COMPACTED NATIVE SUBGRADE. CONCRETE TO BE REINFORCED WITH 6X6, #6 WWM. O4 REMOVE EXISTING CONCRETE SIDEWALK (SEE PLAN FOR LIMITS OF REMOVAL). -________ --- 350 S.F. O5 REMOVE EXISTING CURB AND GUTTER (8" C.F.). (SEE PLAN FOR LIMITS OF REMOVAL). ____ - - - - 75 L.F. O6 REMOVE EXISTING A.C. PAVING. (SEE PLAN FOR LIMITS OF REMOVAL). ---- - - - - - - - - - - - - 113 S.F. O7 COLDPLANE EXISTING A.C. TO A THICKNESS OF 0.10 (WIDTH=24") FOR SMOOTH TRANSITION. - ----- 158 S.F. O8 ADJUST EXISTING (ITEM SHOWN ON PLAN) TO FINISH GRADE. 9O CONSTRUCT FULL DEPTH A.C. PAVING (WIDTH=18") OVER COMPACTED NATIVE SUBGRADE.------------ 113 S.F./4 TON 10 CONSTRUCT CONCRETE CURB AND GUTTER PER CITY OF FONTANA STD. DWG. NO. 1000. ------------ 75 L.F. MODIFY CONCRETE CURB AND GUTTER FOR A 3/8" LIP. o Q?,pF ESS/p v�C cD TERESITO N. TABIOLO LU m RCE No. 38826 Exp. 3-31-11 li C/VIS O��\ OF C P,0 C3 VICINITY MAP NOT TO SCALE THE THOMAS GUIDE, 2008 SAN BERNARDINO COUNTY STREET GUIDE PAGE 604, J-2 KCT CONSULTANTS, INC. Civil Engineers - Surveyors - Planners 4i P.O. Box 5705 Riverside, CA 92517-5705 4344 Latham St., Suite 200, Riverside' CA 92501 Phone: 951-341-8940 Fax: 951-341-8945 e-mail: kctinc@kctconsultants.com Prepared Under The Supervision Of : Date TERESITO N. TABIOLO R.C.E. 38826 EXP. 03-31-11 W.O.: 1380 -OE CITY OF FONTANA. CALIFORNIA STREET IMPROVEMENT PLANS DRAWN BY: IT SEVILLE AVENUE TITLE/,SHET KALL: AS SHOWN DESIGNED BY: DATE: TT AUGUST 2010 CHECKED BY: APPROVED .11 DWG. NO.: '� TT Ire e 4882 2 CITY ENGINEER R.C.E. 51152 DATE