HomeMy WebLinkAbout2231-2SCALE: 1"=20' 1 • 1 1 !illillillillillilk t • t CONDUCTOR E;CHEDUL_E 32' RUN NO. 1 2 3 Z4 A 6 7 8 3 CONDUCTOR SIGNAL CABLE 1 1 1 4 4 3 2 1 5 CONDUCTOR SIGNAL CABLE - - - 1 1 1 1 - 9 CONDUCTOR SIGNAL CABLE - - - - - - - - 12 CONDUCTOR SIGNAL CABLE 1 1 1 2 2 1 1 1 28 CONDUCTOR SIGNAL CABLE - 1 1 - - - - 10 J10 A WG. LUMINAIRE 2 2 - - 2 2 2 2 J12 AWG. CAMERA POWER 1 2 2 1 1 1 1 1 BELDON 18281 CAMERA CABLE 1 2 2 1 1 1 1 1 OPTICOM CABLE 1 2 2 1 1 1 1 1 TV -1-T SP -1 -CS 8 7' 3' 5 26A-4-80 35' 45' 15' 250 W - - - MAS,MAS, SV -2-T - - CONDUIT SIZE 3" 3" 3" 3" 3" 3" 3" 3" EXISTING 1,5' C,INSTALL NEW INTERCONNECT CABLE FROM IU SIGNAL CABINET AT VALLEY AND HEALTHCARE TO NEW CB SIGNAL CABINET ON N/E CORNER PALMETTO AND VALLEY R / W - - - ----------- ------------ ---- ----- ---------------------- - I� II ►I ------ _ -- ---- = - — _ - ,---- -- i r ---'-------- ----------0 --------------------------R 1 ---------- 1. --- II 1,5'C, 1 IC in In --—————————————————————————————————————————————————————— — —r-�— — — — — — — I I I 1 R/W GENERAL NOTES: 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992) 2. ALL WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THESE PLANS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTUCTION, 1997 EDITION. 3. LOCATION OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT 800/422-4133,48 HOURS BEFORE DIGGING. 4. ALL PULLBOXES SHALL BE No. 5 AND CONDUIT SHALL BE 2" RIGID METAL EXCEPT AS SHOWN. ALL VEHICLE HEADS SHALL BE METAL WITH 12" GLASS LENSES AND METALLIC ONE-PIECE LOUVERED BACKPLATES. 5. COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 6. EXISTING STREET LIGHTING TO BE REMOVED SHALL REMAIN IN OPERATION UNTIL NEW LIGHTING IS OPERATIONAL. 7. OBTAIN APPROVAL FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 8. RELOCATE OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 9. CONTROLLER SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. 1-800-422-4133 IT'S THE LAW ! CALL AT LEAST TWO DIAL BEFORE WORKING DAYS PRIOR YOU DIG! _ TO EXCAVATING O /A c Ly� UNDERGROUND SERVICE ALERT OF SOUTHERN CA11FORNIA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILIIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-500-422-4133 DRAWING OF RECORD - 5/00 NO CHANGES CONSTRUCTION NOTES: 3 • ' 32' NOT USED 32' 3 I I I ; I I I PHASE 1 POLE SCHEDULE PHASE 3 ' I ; 20' I i I � 22' 1 L STANDARD ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING PED. S.N.S. LOCATION C TYPE HT. SIG. LU M. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. PHASE MESSAGE A B 1 19A -3 -BO 35' 30' 15' 250 W B 6 E MAS, SV -1-T SP -1 -CS 8 Patmetto Ave, 3' 3' 2 1-A 10 B 8 S TP -1-T 6 T 4' 3 22 35' 15' 250 W B 8 S 9' 4,5' 1-A 10' - - - TV -1-T SP -1 -CS 8 7' 3' 5 26A-4-80 35' 45' 15' 250 W - - - MAS,MAS, SV -2-T - - Patmetto Ave, )K47' T 6 17A-3-80 35' 20' 15')Kx 250 W B 6 W MAS, SV -1-T SP -1 -CS 6 Valley Blvd, )K27' 5,5' INSTALL CONTROLLER ASSEMBLY PER CITY OF FONTANA STD. DETAIL 134 INCLUDING TYPE "P" CABINET, TYPE 90 CONTROLLER AND APPURTENANT EQUIPMENT. SEE SPECIAL PROVISIONS FOR COMPLETE EQUIPMENT LIST. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL EQUIPMENT REQUIRED TO OBTAIN DESIRED OPERATION, INCLUDING OPTICOM AND AUTOSCOPE POWER CABLES. CONTROLLER AND AUTOSCOPE ASSEMBLY MAY BE OBTAINED FROM THE CITY AT CONTRACTORS EXPENSE PER THE SPECIAL PROVISIONS. INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA SPECIFICATIONS AND SOUTHERN CALIFORNIA EDISON REQUIEMENTS. CONSTRUCT SIDEWALK AND CURB ACCESS RAMP PER DETAIL - B THIS SHEET. REMOVE AND REPLACE EXISTING WHEELCHAIR RAMP. INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR (OPTICOM MODEL M711). ROTATE ADDITIONAL LUMINAIRE MOUNT 90 COUNTERCLOCKWISE AS SHOWN. INSTALL CITY FURNISHED AUTOSCOPE DETECTOR CAMERA AS NOTED ABOVE PER CITY STD. DETAIL#133 OR AS DIRECTED BY THE ENGINEER. INSTALL 3" PVC CONDUIT AND PULLROPE PER SOUTHERN CALIFORNIA EDISON REQUIREMENTS. INSTALL R96/R96A SIGNS ON SIGNAL STANDARD AS SHOWN (QUANTITY-2EA.). INSTALL #5 PULLBOX FOR SIGNAL INTERCONNECT. SPECIAL NOTE: THE CONTRACTOR IS NOTIFIED OF EXISTING CONCRETE PAVEMENT APPROX. 4in. TO 6in. THICK AND 40 ft. WIDE UNDER EXISTING PAVEMENT ON VALLEY BLVD. NOTE: 1. For "A"&"B" dimensions refer to Pole Schedule, or as directed by the Engineer. Negative A" dimensions refer to a distance departing intersection away from BC or EC. SIGNAL STANDARD PLACEMENT DIMENSIONS & EQUIPMENT LOCATIONS PHASE DIAGRAM NOT USED NOT USED NOT USED PHASE 1 PHASE 2 PHASE 3 PHASE 4 NOT USED l� 1 PHASE 5 PHASE 6 PHASE 7 PHASE 8 PROPOSED SIGNAL STANDARD E: SI VARIABLE SLOPE 10% MAX. 0,0' CURB FACE CURB ACCESS RAMP "DETAIL - B" 4' MIN ACAD FILENAME: VaRmto—RevPlan.