Loading...
HomeMy WebLinkAbout2576-251 iCTTAI/-% CI n -r 38-1/2" 33-3/8" 16-11/16 30" NOTES: 1. CAST IRON SHALL CONFORM TO ASTM )LE A-48 CLASS 35 B. IA 2. WEIGHT OF FRAME SHALL BE 304 lbs - 352 lbs WEIGHT OF COVER SHALL BE 290 lbs - 336 lbs. 3. THE LETTERS "S" SHALL BE CAST INTO THE TOP OF THE COVER WITH A LINE WIDTH OF 1/2", A HEIGHT OF 2 1/2", AND BE FLUSH WITH THE FINISH SURFACE OF THE COVER. 4. MANHOLE COVER SHALL BE ALHAMBRA FOUNDRY CO. PLATE NO A-1497 OR N APPROVED EQUAL. I 5. FRAME AND COVER SHALL BE COATED WITH BITUMINOUS PAINT. 6. THIS DETAIL APPLIES TO ALL MANHOLE FRAMES AND COVERS NOT OTHERWISE SPECIFIED. MANHOLE FRAME AND COVER DETAIL rA NOT TO SCALE - PIPE TO TO BE PLUGGED, SEE DTL B THIS SHEET — EXIST 15" VCP TO BE' ABANDONED INV EL=1134.24' NEW 15" VCP MANHOLE DETAIL KOOE •s4. . L• � •t . . . . . . . . . . .FLOW. . . •1 \ 'r" i INV EL=1134.24' DETAIL c zn vur )NM 1'-8" MIN z ow d- N #5 EPDXY COATED u LIFTING HOOK REBAR LIFTING HOOK BELL END STUB 1'-4" MIN FILLED WITH NON -SHRINK GROUT 7 I 6» 2 #5 HOOKS 1. FOR PLUGS TO FIT BELL END OF PIPE, FABRICATE FROM SPIGOT END OF PIPE. MINIMUM LENGTH OF PLUG SHALL BE V-4". 2. SHOP DRAWINGS ARE REQUIRED FOR PIPE PLUGS FOR ALL PIPE MATERIALS TO BE USED ON THIS PROJECT. 3. ALL PIPE NOT CONNECTED TO ANOTHER PIPE SHALL BE FITTED WITH A PIPE PLUG. PIPE PLUG DETAIL B NOT TO SCALE - 19' (±) 1 (TYP) 60" DIA , 1/2" WALL THICKNESS UGGED, SEE 22' STEEL CASING PIPE IS SHEET 36" DIA VCP a o • o• Q o o o. EXIST 21" (6) 2" SCH 80 PVC 1' EQ EQ 1' VCP TO BE NT PIPE (TYP) ABANDONED - `� SAW CUT CONCRETE WALLS 0 -EQa. E� ' a a• 4 ° a a• ° a° PROVIDE 6" SCH 80 PVC DRAIN (TYP) Camp Dresser &McKee Inc. 9220 gevelend Ave", 3iite 100 Rancho Cucamonga, CaiforNa 91730 Tek (809) 573500 Fax (909) 980-5185 EXIST MANHOLE INV EL=1134.25'± EXIST 15" VCP SEE NOTE 1 � PLUG ENDS OF CASING PIPE WITH NON -SHRINK C 271 GROUT (TYP) EAST PEDESTRIAN TUNNEL CROSSING DETAIL rF' 3/16" = 1'-0" C-5 SAW CUT CONCRETE TUNNEL (SEE NOTE 3) VARIES 1' (MIN) 6'_0" 1' I (MIN) I VARIES STAINLESS STEEL STEEL STRAPPING BANDS, 2-REQ'D PER ALL ANNULAR SPACES BETWEEN / SPACER SET CASING AND CARRIER PIPES TO BE BLOWN FULL ALL AROUND SPACERS, 3-REQ'D PER SPACER SET. WITH STABILIZED WELL GRADED 1 SPACER SET ON EACH CARRIER PIPE FINE GRANULAR MATERIAL JOINT (2 SETS PER PIPE) EAST PEDESTRIAN TUNNEL CROSSING SECTION 1 NOT TO SCALE - _DIG�LE_� T TOLL FREE -qmmmmw- 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT N SEWER '•�- .'° ° ° a CARRIER MAX PIPE JOINT OD 36" VCP r�� , mme�rraer,� \ Lu o o \ :v:.' \ a U) TEMPORARY SEWER a °¢ �� (' MINIMUM C, EARANCE JACK (TYP) ? v \ SHALL BE 4" (102mm) SEE NOTE 2 wo Q �': EXIST CO a .r a (TYP) w Q f 60" DIA AND 1/2" WALL • cwn L°' THIrKNESSj STEEL CASING PIPE 8" VCP BEND -a-. SEE N OTE 1 UNDISTURBED °• I I EARTH NOTES: STAINLESS STEEL STEEL STRAPPING BANDS, 2-REQ'D PER ALL ANNULAR SPACES BETWEEN / SPACER SET CASING AND CARRIER PIPES TO BE BLOWN FULL ALL AROUND SPACERS, 3-REQ'D PER SPACER SET. WITH STABILIZED WELL GRADED 1 SPACER SET ON EACH CARRIER PIPE FINE GRANULAR MATERIAL JOINT (2 SETS PER PIPE) EAST PEDESTRIAN TUNNEL CROSSING SECTION 1 NOT TO SCALE - _DIG�LE_� T TOLL FREE -qmmmmw- 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT N 8" VCP TEE vt • •fir• _ �� %�' w r�� , mme�rraer,� z a Lu o o \ :v:.' \ 8„ VCP U) x z SEWER w a F- crw ? v \ >_j wo CL v CONCRETE w ENCASEMENT • cwn 8" VCP TEE DROP MANHOLE DETAIL rc NOT TO SCALE - NOTES: 1. FILL WITH CLASS 490 -C -2000P CONCRETE. CONCRETE SHALL BE POURED IN A MIN OF 3 LIFTS. LIFTS SHALL NOT BE POURED UNTIL PREVIOUS HAS ACHIEVED 30% OF ULTIMATE DESIGN STRENGTH. 2. INSTALL TEMPORARY JACKS PRIOR TO SAW CUTTING EXIST ROOF STRUCTURE. REMOVE JACKS AFTER FILL CONCRETE HAS ATTAINED ULTIMATE DESIGN STRENGTH. 3. CONTRACTOR SHALL FIELD LOCATE EXIST REBAR (BOTTOM MAT) IN TOP SLAB USING A PICOMETER PRIOR TO CUTTING ANY CONCRETE AND REPORT RESULTS TO ENGINEER. 4. CUTTING OF EXISTING REBAR WILL BE ALLOWED UPON APPROVAL OF THE ENGINEER. FLUSH WITH CHANNEL WALL B MANHOLE WALL SHELF PLASTIC SHEET HELF BOND BREAKER (20 MIL MIN SHAPED INVERT .,CHANNE B LEAN CONCRETE 0 SECTION B -B NON -SHRINK GROUT TEMPORARY CHANNEL PLUG DETAIL G NOT TO SCALE - 6" SEWER LATERAL 36" TRUNK SEWER SEWER LATERAL CONNECTION TO TRUNK SEWER DETAIL J NOT TO SCALE C-4 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. EL y KNURLED SURFACE 11� FACE OF .o. CONC WALL 1, s A POLYPROPYLENE o: COATED ASTM A615 7„ D GRADE 60 STEEL '6'-- #4 REBAR 4' - MANHOLE STEP DETAIL rD NOT TO SCALE - NEW 10" VCP INV EL=1113.11' ,o FOOTING STOP GATE AND �' ; INV EL=1111.45' GUIDE, SEE DTL A SHEET C-28 INV EL=1111.52' INV EL=1111.42' NEW 30" IINV EL=1111.42' NEW 10" N NOTES: VCP 1. 36" DIAMETER MANHOLE FRAME AND COVER SIMILAR TO DTL A SHEET C-27 MANHOLE N0. 51 POPLAR AVE DIVERSION DETAIL H PLASTIC INJECTION EXPANSION RING INDEXING DIMPLES INDEXING DIMPLES PROVIDE GUIDE FOR PROPER ALIGNMENT AND SYNTHETIC RUBBER FITTING INSTALLATION WITH FLANGE STOPPER TO PREVENT LATERAL AND (TAP -N -TEE OR APPROVED EQUAL) �'� EXPANSION RING PROTUSION INTO CAIN LINE YP. 'RESSION BAND ERA TO IE \—TRUNK SEWER (SIZE REDUCED FOR CLARITY) 1. TEE FITTING SHALL MEET OR EXCEED ASTM C-923, ASTM C-1173, ASTM C-425, AND ASTM A-167. 2. THE CORED HOLE SHALL BE MADE WITH EQUIPMENT SPECIFICALLY DESIGNED TO CUT A SMOOTH HOLE WITHOUT SPALLING TO PREVENT DAMAGE TO THE PIPE OR STRUCTURE. 3. THE CORING OF THE HOLE AND THE PLACING OF THE STUB SHALL BE DONE IN THE PRESENCE OF THE CITY INSPECTOR. 4. NO CONNECTION SHALL BE MADE TO THE STUB UNTIL THE CITY INSPECTOR HAS APPROVED THE STUB. Prepared Under The Supervision Of : CITY OF FONTANAI CALIFORNIA SAN BERNARDINO AVENUE TRUNK SEWER DRAWN BY: SCALE: WF/CEB MISCE USDETAILS II DA>E NOTED DESIGNED BY NL NOV 2006 Date :///L�O� CHECKED BY: APPRO BY: DRAWING NO.: 25 Itl70 a 04c 0527 2 DKT/LRL CITY ENGINEER R.C.E. 51152 DATE: 7 a� U U v a� v m E a N 0 0 d- 0 z rn r` N U LiI z 0 J 1-11 U N w V) I 0 w W y z D Ofm ui N �r- v C: v c 0 LL_ I Ui i U) U a� 0 1` 1_ -v v U I i U vt • •fir• _ �� %�' w J O 2 LL o w z a Lu o o \ :v:.' \ 8„ VCP U) x z SEWER w a F- crw ? v \ >_j wo CL v CONCRETE w ENCASEMENT • cwn 8" VCP BEND UNDISTURBED EARTH NOTES: 1. FOR ADDITIONAL CONSTRUCTION REQUIREMENTS SEE PLAN AND PROFILE SHEETS. DROP MANHOLE DETAIL rc NOT TO SCALE - NOTES: 1. FILL WITH CLASS 490 -C -2000P CONCRETE. CONCRETE SHALL BE POURED IN A MIN OF 3 LIFTS. LIFTS SHALL NOT BE POURED UNTIL PREVIOUS HAS ACHIEVED 30% OF ULTIMATE DESIGN STRENGTH. 2. INSTALL TEMPORARY JACKS PRIOR TO SAW CUTTING EXIST ROOF STRUCTURE. REMOVE JACKS AFTER FILL CONCRETE HAS ATTAINED ULTIMATE DESIGN STRENGTH. 3. CONTRACTOR SHALL FIELD LOCATE EXIST REBAR (BOTTOM MAT) IN TOP SLAB USING A PICOMETER PRIOR TO CUTTING ANY CONCRETE AND REPORT RESULTS TO ENGINEER. 4. CUTTING OF EXISTING REBAR WILL BE ALLOWED UPON APPROVAL OF THE ENGINEER. FLUSH WITH CHANNEL WALL B MANHOLE WALL SHELF PLASTIC SHEET HELF BOND BREAKER (20 MIL MIN SHAPED INVERT .,CHANNE B LEAN CONCRETE 0 SECTION B -B NON -SHRINK GROUT TEMPORARY CHANNEL PLUG DETAIL G NOT TO SCALE - 6" SEWER LATERAL 36" TRUNK SEWER SEWER LATERAL CONNECTION TO TRUNK SEWER DETAIL J NOT TO SCALE C-4 SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. EL y KNURLED SURFACE 11� FACE OF .o. CONC WALL 1, s A POLYPROPYLENE o: COATED ASTM A615 7„ D GRADE 60 STEEL '6'-- #4 REBAR 4' - MANHOLE STEP DETAIL rD NOT TO SCALE - NEW 10" VCP INV EL=1113.11' ,o FOOTING STOP GATE AND �' ; INV EL=1111.45' GUIDE, SEE DTL A SHEET C-28 INV EL=1111.52' INV EL=1111.42' NEW 30" IINV EL=1111.42' NEW 10" N NOTES: VCP 1. 36" DIAMETER MANHOLE FRAME AND COVER SIMILAR TO DTL A SHEET C-27 MANHOLE N0. 51 POPLAR AVE DIVERSION DETAIL H PLASTIC INJECTION EXPANSION RING INDEXING DIMPLES INDEXING DIMPLES PROVIDE GUIDE FOR PROPER ALIGNMENT AND SYNTHETIC RUBBER FITTING INSTALLATION WITH FLANGE STOPPER TO PREVENT LATERAL AND (TAP -N -TEE OR APPROVED EQUAL) �'� EXPANSION RING PROTUSION INTO CAIN LINE YP. 'RESSION BAND ERA TO IE \—TRUNK SEWER (SIZE REDUCED FOR CLARITY) 1. TEE FITTING SHALL MEET OR EXCEED ASTM C-923, ASTM C-1173, ASTM C-425, AND ASTM A-167. 2. THE CORED HOLE SHALL BE MADE WITH EQUIPMENT SPECIFICALLY DESIGNED TO CUT A SMOOTH HOLE WITHOUT SPALLING TO PREVENT DAMAGE TO THE PIPE OR STRUCTURE. 3. THE CORING OF THE HOLE AND THE PLACING OF THE STUB SHALL BE DONE IN THE PRESENCE OF THE CITY INSPECTOR. 4. NO CONNECTION SHALL BE MADE TO THE STUB UNTIL THE CITY INSPECTOR HAS APPROVED THE STUB. Prepared Under The Supervision Of : CITY OF FONTANAI CALIFORNIA SAN BERNARDINO AVENUE TRUNK SEWER DRAWN BY: SCALE: WF/CEB MISCE USDETAILS II DA>E NOTED DESIGNED BY NL NOV 2006 Date :///L�O� CHECKED BY: APPRO BY: DRAWING NO.: 25 Itl70 a 04c 0527 2 DKT/LRL CITY ENGINEER R.C.E. 51152 DATE: 7 a� U U v a� v m E a N 0 0 d- 0 z rn r` N U LiI z 0 J 1-11 U N w V) I 0 w W y z D Ofm ui N �r- v C: v c 0 LL_ I Ui i U) U a� 0 1` 1_ -v v U I i U