Loading...
HomeMy WebLinkAbout4343-41�INIISIJ GRADE VAI:bYl:13i�X (LAWN) V Y'A I:.R. I,FR.Y, JC i LINE (if F3j p icablL: ) 2X4 REDWOOD BLOCK CON' I:NUO1j1 ARO ND GATE VALVE WATERPROOF ALL WIRE CONNEIr, i IONS AS PER STD. RED BLACK I—.. I=INISII GLADE PVC SCH 80 FIPPLE (TYPICF (GROI, D COQ_ R) LENGTH AS REQUIRED) LINE SIZE BRASS GATE VALVE EVC MA -LE ADAPTOR I'V C IRRIGATION MAIN PVC SCH 80 UNION FOR CUBIC x00*F P13A GRAVEL FILL WHITE (COMMOM SUE o. FLOW SENSOR DIAMETER SAME SIZE AS F OW METER SIZE III- 4 W RES N.T.S. 110 MASTER CONTROL VALVE MINIMUM DISTANCE DOWNSTREAM - 5X DIAMETER OF FLOW METER SIZE PVC SCH 40 ELI CONTROL ZONE KIT 30 -INCH LINEAR LENGTH OF WIRE, COILED WATER PROOF CONNECTION: RAID BIRD SPLICE -1 (1 OF 2) VALVE BOX WITH COVER: RAIN BIRD VB->.IMB ID TAG: RAIN BIRD VID SERIES TOP OF MULCH FINISH GRADE CONTROL ZONE KIT: RAID BIRD XCZ-PRB-100-COM (INCLUDES BALL VALVE, 100 PESB VALVE, AND QKCHKI BB PRESSURE REGULATED BASKET FILTER) PVC LATERAL PVC SCH 40 MALE ADAPTER PVC SCH 80 UNION FOR SERVICING ASSEMBLY PVC SCH 80 NIPPLE, CLOSE PVC MAINLINE 3 -INCH MINIMUM DEPTH OF 3/4 -INCH WASHED GRAVEL BRICK (1 OF 4) PVC SCH 40 TEE OR ELL N.T.S. 17 1/4—INCH TUBING: POLYETHYLENE DISTRIBUTION TUBING RAID BIRD XQ OGLE—OUTLET EMITTER: IN BIRD XERI—BUG EMITTER XB-10PC 1/4—ITCH BARB TRANSFER TEE: RAIN BIRD XBF3TEE "LL SATURATE AND COMPACT TO 90 ESCAPING 2D4 MI NATIVE BACKFILL" MINUS NON PRESSURE LATERAL LINE W/SLEEVE PRESSURE SUPPLY LINE W/SLEEVE CONTROL WIRE SLEEVE SAND BACK FILL INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE, SIZE PER SPEC. ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE LINE TO BE SLEEVED. INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY INSPECTOR IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL. SLEEVING PRESSURE REGULATOR IF REQUIRED. SET AS SHOWN ON SITE DRAWING STRAINER #40 - MESH MODEL BRASS ELBOW BRASS BALL VALVE BRASS PIPE 1pn LOOSE KEY I HOSE BIB\ _ 18" SUPPLYRLINE (TRUST SBLOC )ERS FRONT (INTAKE) 'z /e=� f to A%jr-t PORT i7 PRESSURE— SUPPLY LINE (DISCHARGE) N.T.S. REDUCE PRESSURE BACKFLOW PREVENTER BRASS NIPPLE (4 PLACES) BRASS ELBOW • BRASS UNION -BRASS PIPE -BRASS BALL VALVE LOCK BOX #4 REBAR t `FOOTING/FOUNDATION BACKFLOW ENCLOSURE (SEE NOTE BELOW) BRASS ELBOW BRASS UNION BRASS BALL VALVE #4 REBAR NOTE: BACKFLOW ENCLOSURE, "GUARDSHACK" SIZE TO FIT E N D R TO GRADE/TOP OF MULCH --COUPLING VALVE: V BIRD MODEL 33DRC BOX WITH COVER: 'SH SIZE WITH 2" LETTERS OV :K BOLT NIPPLE 4GTH AS REQUIRED) H MINIMUM DEPTH OF :D PEA GRAVEL STREET ELL (1 OF 2) NIPPLE 4GTH AS REQUIRED) ELL WITH BRASS THREADED NIPPLE CH 40 TEE OR ELL IAINLINE PIPE ELL far "'BAR 2434 LONG W/ STAINLESS STEEL GEAR CLAMPS OR EQUIVALENT NOTE: SUPPORT SYSTEM 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLING VALVE INLET SIZE. 4 I QUICK -COUPLING VALVE EMISSIOI SAME A,' AT GRAD INSIDE VIEW OF X -ERI"" BIRO (7) REMOVABLE PORT PLUGS XBD—BO B—INCH VALVE BC3X RAIN BIRD VB—GRND MULTI—OUTLET EMISSION DEVICE RAIN BIRD XERI-BIRD XBD-80 N.T.S. 11 rOP OF MULCH FINISH GRADE 1/4—INCH TUBING: 30LYETHYLENE DISTRIBUTION TUBING RAIN BIRD XQ = MINIMUM DISTANCE UPSTREAM 1/4—INCH TUBING STAKE: HINGED AT ONE END SECU E 6"x8" FOOTING w/4" J BOLTS (EQUIPMENT TO BE CENTERED p o0 0 IDX DIAMETER OF FLOW FAIN BIRD TS -025 INSIDE HOUSING) Qo PVC SCH BO CLOSE NIPPLE METER LR SIZE C0i C� PVC LATERAL PIPE i.. •rr y GENERAL NOTES 1L _ U) 0 PVC SCH 40 TEE OR ELL 1/4—INCH TUBING RUN FROM XERI—BIRD 1. CONTRACTOR SHALL FORM ENCLOSURE AND REQUEST INSPECTION! N POLYETHYLENE DISTRIBUTION TUBING PRIOR TO POURING FOOTING/FOUNDATION NOTE: 3—INCH MIN. DEPTH OF I RAIN BIRD XO = — COIL ADDITIONAL 9—INCHES OF TUBING IN 3/4—INCH WASHED GRAVEL DO LoCL 2. USE 520—C-•2500 CONCRETE VALVE BOX TO FACILITATE MAINTENANCE. r O = XERI-BIRD IN VALVE BOX MASTER VALVE FLOW SENSOR N■T■S. 11 EMITTER AROUND PLANT ON 1/4" TUBING N.T.S. 8 BACKFLOW PREVENTER I.T.S. 5 XERI-BIRD MULTI -OUTLET EMISSION DEVICE N.T.S. 2 FINISHED GRANDE 1 FIELD SAT ELLITE CONTROLLER: 6" MIN FROM HARDSCAPES ELEVATION ESB12-U2--MPEA1 61 O - OB1 -VRA 6'9 . _ , 4 _4 CONCRETE PAD: —INCH -1 11=1 11=1 11=1 I=1 11=1 11=1 I E MINIMUM THICKNESS z -1 I -I I -I I I l ElE-I 11-I VALVE BOX 1,1111 IIII IE IIIII II1- .; NON PRESSURE LATERAL LINE 9 FINISH GRADE FINISH GRADE =I I I=1 PLAN VIEW TYP. CONCRETE 1 (CROI ND COVER) — — ¢- 1 � I—I I I —,- T = I ;III= PRESSURE SUPPLY LINE zzz_1 ES TO R T _ =1 � THRUST BLOCKS I= ---- Z_ �'' I`�"I, "' I� REMOTE � SON IDOL. _ � _ � = CC�NTRaLL WIRES ; IIIII � � ���-��� I I=1 I I � =111 1 III 1 II CLEAN BACKFILL 2Y9 MINUS4 ;Z1 ,INCH QVC SCH IO CONDUIT,=M1611 FITTINGS AND SWELL ELL � 1—I � I-11 I I � 1—III ITI=1 � E --Ili 1 1 1=1 1 1 ;,111,;,111,;,111 ;,111 , 11,; 1111...11, ,1�1,ii ILI:;, SAND TYP. CONCRETE TO REST Aw,1AGAINST UNDISTURBED —INCH IVC SCH 40 CONDUITS F117INGS AND SWEEP ELL. TO SOIL f POWER SUPPLY 6"MIN °�+ '• $� AJ ilJ .• FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES, NO REBAR DETAIL PVC IRRICi;1"I'IUNMAIN / LARGER THAN 1/2" INCH IN SIZE. THIS WILL BE PERMITTED IN THE INITIAL BACKFILL MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER NOTE: THRUST BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH WIPE OF TRENCH CAN BE FILL WITH ROCK SCREENED 242 MINUS. MANUFACTURER'S RECOMMENDATION FOR SIZE OF PIPING REQUIRED. 2..X4 RI=.DWOOD BLOC:. _/ CONTINUOUS AR01U',N.I:I I CUBIC FOOT PEA GR. VEL FILL ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90% " INSTALL ALL PVC PIPE WITH LABEL UP. UTILIZED IN ALL (2 1 /2 AND LARGER MAINLINE PIPE} 2 #3 REBAR TO BE PLACED AROUND PIPE INTO THRUST BLOCK TYP. SNAKE ALL PIPE IN TRENCH. BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE � SUPPLY' LINE AND PROVIDE A SERVICE LOOP AT ALL 90 DEGREE CITY OF FCALIFORNIA INSTALI__ REDUCED PRESSURE REGULATOR PER MANUFACTURERS CHANGES IN DIRECTION. a INSTRUCTIONS AND LOCAL CODES. ����������� d a �j���� PRESSURE MAIN 2" AND LARGER SHALL BE P.V.C. CLASS 315 REGULATOR SHOULD BE SET AT 85 FSI. SMALLER THAN 2?8 SHALL BE P.V.C. SCHEDULE 40. Drawn By: Scale: LKD JRO C.F.D. LANDSCAPE IMPROVEMENT PLANS 1 "— 30' CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN — 4 MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. Designed B . 7 for Date: 64 H F DOVER OVER PIPE R.J.P. ' T T NO . 16658 3/23/2012 CONTRACTOR SHALL PROVIDE 24 INCHES O 6 SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE APPROVED- / • ZI 5P V. �z . ........Dwg. No. 4 32' AND LARGER, CITY ENGINEER: RICARDO SANDOVAL LIC.#51192 4343 i REDUCED PRESSURE REGULATOR N■T■S■ 12 AUTOMATIC CONTROLLER N.T.S. 9 TRENCHING N.T.S. 6 THRUST BLOCK ASSEMBLY R I C H A R D popf Landscape Architecture 1585 S.'D' Street, Suite 103 San Bernardino, CA 92408 phone: (909) 888-5568 fax: (909) 384-9854 e-mail: rpa.la@ve6zon.net www.dchardpopeandassociates.com Richard Pope, Landscape Architect CA# 2664 \,ptA DSCA P, Ic ppPE LIC -- 0FF, A, %_W Owner/Applicant: JD Fontlee, LLC 3185 Airway Avenue, #F2 Costa Mesa, CA 92626 (714) 210-8850 Sheet Description: Irrigation Details Date: September 18, 2006 RP*A Job No.: 12-06 Drawn by: LKD GRP Revl51on5: Add cobblestone (07-24_1111107) Revise cobblestone (08-33 11110108) Revise per New CA Irrigation Standards AB 1881 (11-132115112) Revision to cobblestone (12-06_3123112) Sheet: L-4 Of: 7 v ■ Li■ C0i C� Ri i.. •rr y 1L _ U) 0 O C13 N y.r v ■� p :01 i O. I M U6 = — DO LoCL r O = v U C3 N cc ■la ch -p O v o u cc Wj Sheet Description: Irrigation Details Date: September 18, 2006 RP*A Job No.: 12-06 Drawn by: LKD GRP Revl51on5: Add cobblestone (07-24_1111107) Revise cobblestone (08-33 11110108) Revise per New CA Irrigation Standards AB 1881 (11-132115112) Revision to cobblestone (12-06_3123112) Sheet: L-4 Of: 7