HomeMy WebLinkAbout4086-1STORM DRAIN IMPROVEMENT NOTES 1. ALL WORK SHALL_ DE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED, 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION, 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS, 5, CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK, INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350--7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SI -TALI_ BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL_ OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL_ CONTACT UNDERGROUND SERVICE ALERT AT 1--800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12, THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13, THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH FHE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS, 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15, ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. REMOVAL AND REPLACEMENT OF TI 17. EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR, SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. '18. THE CONTRACTOR SHALL_ MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES, A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19, THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22.A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL_ COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL_ THE SPECIFIED DENSITY IS OBTAINED. 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS, UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE, 25, NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OT HE CITY ENGINEER. lij w 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, ci AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF a ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. BASIS OF BEARINGS. --TLEQAL DESCRIPTION: F FONTANA y„ `IK Y hti i QUANTITY 0 CONSTRUCT (12'W X 8'H) CAST -IN --PLACE REINFORCED 3,.243 L. F. 15 CONSTRUCT 6' CUTOFF WALL PER CALTRANS STD. PLAN D84. CONCRETE SINGLE BOX PER STRUCTURAL,. DETAILS 24 15 (SEE SHEET- 10) ON SHEET 9. AVENUE 16 REPLACE EXISTING .STREET STRIPPING IN KIND. CONSTRUCT TRANSITION STRUCTURE PER APWA STD. 5 EA. 17 REMOVE AND REPLACE EXIST. AC PAVEMENT, c PLAN 341-1. (SEE SHEET 14) BEECH �3 SIERRA (n CONCRETE COLLAR PER APWA STD, AVENUE CONSTRUCT (14'W X 7'H) CAST -IN --PLACE REINFORCED 188 L. F. 18 CONSTRUCT CHAINLINK WALL. FENCE PER CALTRANS STANDARD 811-52. CONCRETE SINGLE BOX PER CALTRANS STD. D80 LS -- - ("SEE SHEET 15) 0 (SEE SHEET 10) CONSTRUCT (14'W X 1O'H) CAST ---IN-PLACE REINFORCED 150 L. F. 19 CONST T A 6" AC OVER 12" 95i C MPACTED NAT L.F, CONCRETE SINGLE BOX PER CALTRANS STD. 080 ��\r' (SEE SHEET 10) SHEET/VICINITY MAP/INDEX MAP 20 CONSTRUCT CONCRETE DROP INLET PER RCFC & WCO STD. DWG. C6110. �' CONSTRUCT (14'W X 12'H) CAST -IN-PLACE REINFORCED 200 L.F.21 CONSTRUCT 24" RCP WITH SLURRY BACKFILL_ PER PROFILE (LD-�' LOA6 PER LINE CONCRETE SINGLE BOX PER CALTRANS STD. D80 TO STA. 482+00.00 PROFILE). SF ��,�' (SEE SHEET 10) 1.1 SLOPE OR FLATTER OR ADEQUATE SHORING 22 CONSTRUCT 36" GCP PIPE INLET PER SSTD. PLAN CALTRANS 7 R D 5Ba 6 CONSTRUCT (16'W X 10-1) CAST -IN-PLACE REINFORCED 829 L. F. 4914-00.00 SEE SHEET 14 CONCRETE SINGLE BOX PER STRUCTURAL DETAILS ON SHEET 9. 23 CONSTRUCT JUNCTION STRUCTURE PER APWA STD. PLAN 333-1. 0 CONSTRUCT 1/2 TON CONCRETE RIP -RAP (T=4.5) 378 CY. (SEE SHEET 1.3) WITH 12" NO, 3 BACKING PER CALTRANS STD. SPEC. 24 SAWCUT EXISTING PAVEMENT. 4 SECTION 72 (METHOD A). (SEE SHEET 2) STA. 491+00.00 TO STA. 499+00.00 IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL 8 CONSTRUCT CONCRETE BOX MANHOLE PER APWA STD. PLAN 323---1, 7 EA. 25 CONSTRUCT OUTLET PROTECTION BARRIER PER S.B.C.F.C.D. S.P.101. 5 (SEE SHEET 10) STA. 499+00.00 TO STA, (SEE SHEET 13) CONSTRUCT PRESSURE MANITOLS PER APWA STD. PLAN 328 -1. 2 EA. � CONSTRUCT RETAINING WALL GUTTER PER CALTRANS STD. PLAN B3-9. 6 (SEE SHEET 1 1) P"B," B STA. 507+00.00 TO STA, (SEE SHEET 14) 10 REMOVE AND REPLACEEXIST. CHAINLINK FENCE IN KIND 1 LS 27 RLRLOCATE T 6" TE INF PE PL CS. 2 EA, 1 LS 1 LS 100 L.F. EXIST. FUTURE NORT-1 WEST R W 61 vi�' EXIST EXIST. -_- R/W 33' VARIES H 34' __ ___ _ p I I B 4, o f 20' ISAWCUTIREMOVE EXIST. PAVEMENT I ` PROP. AC " 4 ® , PAVEMENT 4 FT 2.0% FUT. CONC.-J Sin EtAIALK FUTURE- CONC. CURB & GUTTER COVER VARIES FROM 4' TO 7' OVER RCB 115 L. F. 1 EA 100 LF 1 LS 4/1-\ PROP.12'X8"�.RCB j D.. \ ` 28' TO FACILITATE STORM DRAIN IMPROVEMENTS, 11 REMOVE AND REPLACE IN KIND EXIST. SIGN TO 1 • , d , ERS A D AL E BOX LS 28 CONSTRUCT 18" RCP (D -LOAD PER PROFILE) 24 15 AVENUE S(.JMMIT < AVENUE,, BEECH c AVENUE BEECH �3 SIERRA (n CONCRETE COLLAR PER APWA STD, AVENUE LAKE PKIWY EA _ LS -- - w_SHEE EXIST. FUTURE NORT-1 WEST R W 61 vi�' EXIST EXIST. -_- R/W 33' VARIES H 34' __ ___ _ p I I B 4, o f 20' ISAWCUTIREMOVE EXIST. PAVEMENT I ` PROP. AC " 4 ® , PAVEMENT 4 FT 2.0% FUT. CONC.-J Sin EtAIALK FUTURE- CONC. CURB & GUTTER COVER VARIES FROM 4' TO 7' OVER RCB 115 L. F. 1 EA 100 LF 1 LS 4/1-\ PROP.12'X8"�.RCB j D.. \ ` 28' TO FACILITATE STORM DRAIN IMPROVEMENTS, 11 REMOVE AND REPLACE IN KIND EXIST. SIGN TO 1 • , d , ERS A D AL E BOX LS 28 CONSTRUCT 18" RCP (D -LOAD PER PROFILE) 24 LF FACILITATE CONSTRUCTION OF DRAINAGE IMPROVEMENTS, 29 CONSTRUCT CONCRETE COLLAR PER APWA STD, PLAN 380-2 EA 12 REMOVE EXISTING DRAINAGE STRUCTURE, 1 LS -- - w_SHEE INDEX 13 CONSTRUCT RETAINING WALL TYPE 1 PER CALTRANS STD, PLAN 83--1. 100 L.F, �\' r ��\r' 1 SHEET/VICINITY MAP/INDEX MAP TITLE (SEE SHEET 14) �' ,i' 2 LINE "B" STA. 475+06.45 TO STA. 482+00.00 ( CONSTRUCT 8" CLASS "A" CONCRETE INVERT SLAB WITH NO.4 1,000 DREBAR @ 18'" O.C. B,W. SF ��,�' \� 1.1 SLOPE OR FLATTER OR ADEQUATE SHORING ��\/ 3 LINE "B" STA. 482.4-00.00 TO STA. 4914-00.00 "B" 27, IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED %°i,/ 4 LINE STA. 491+00.00 TO STA. 499+00.00 IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL �\ 90% COMPACTED NATIVE 3" MAX. SIZE,> 5 LINE STA. 499+00.00 TO STA, 507+00.00 AFFECTED AGENCIES IMMEDIATELY. °'���.' ', BACKFl11 3" MAX SIZE\\. NATIVE SOIL COMPACTED 95.E 6 LINE P"B," B STA. 507+00.00 TO STA, 514+00.00 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE _6" MIN. , "B" BEEN PLACED, INSPECTED AND APPROVED. ✓, 8" MAX. fit 7 LINE STA. 514+00.00 TO STA, 523+00.00 29, ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR� \\� 8 PROFILES SHEET TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT GRANULAR BEDDING FROM 9-16 DETAIL SHEETS PRIOR TO PLACEMENT, SELECTED TRENCH SIDE LEGEND 31 ALL MA MANHOLES C'LEANOl1T FRAMES COV N V V I I f - B- MATERIAL (I" MAX SIZE). ES SHALL BE RAISED TO _ f FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. STRIPING,CMPLIOD D1HERTFTRLDSORTALL TSC BARRICAS,AN0RAIICCONTTOEVIC RESTORE E SATISFACTION OF THE CITY TRAFFIC ENGINEER. LLI = 33. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. _m-- 34. MINIMUM D -LOAD FOR STORM DRAIN PIPE IS 1350. STORM DRAIN PIPE--- 0.6'D' =.i 35. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONRETE PIPES AND STORM DRAIN STRUCTURES MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE REINFORCING WHEN GRANULAR BEDDING FROM SELECTED THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STRENGHT IN THESE TRENCH SIDE MATERIAL FOR PIPE REACHES SHALL BE FC = 5,000 PSI FOR VELOCITIES EXCEEDING 20 FEET PER SECOND AND FC = 10' OR GREATER IN DEPTH USE 6,000 PSI FOR VELOCITIES EXCEEDING 30 FEET PER SECOND. 1/2 CRUSHED STONE BEDDING. NOTES 112 IL ENGINEER 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE. COMPACTION SHALL BE 90,`a IN ALL LR GEOTECHNICAL GROUP INC. 2. TRENCH DEPTHS OF GREATER THAN 5' ZONES UNLESS OTHERWISE SPECIFIED, 6121 QUAIL VALLEY COURT I SHALL HAVE ADEQUATE SHORINt,. TRENCH STABILITY SHALL CONFORM BEINGA SUBDIVISION OF A PORTION OF THE NORTHEAST 1/4 OF RIVERSIDEa 92507 3. CLASS Ll AGGREGATE BASE ALL TO CAL -OSHA REQUIREMENTS. SECTION 23, TOWNSHIP t NORTH, RANGE 6 WEST, SAN BERNARDINO, Ph. ( 1)653-T760 TRENCHES LESS THAN 100 IN LENGTH. COUNTY OF SAN BERNARDINO. F a f4%ar,43TRENCH DETAIL -1741 NOT TO SCALE a X.REV. REVISION DESCRfPTRON DA E ENGR. CITY DATE - HOULD CONSTRUCTION OFTHE REQUIRED IMPROVEMENTS NOT yRECORD DR4WINGI 11° AUT Dr" COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON ANS CARRIED FORTH IN A ILIGENT MANNIPP, THP CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDSIN EFFECT. TOLL FREE '1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT SEAL -ENGINEER I mmulap al qLm CIL OR C. L. OR CB FL INV MH R/W RCP SD SEW S TA TC VCP WA T - -FO- - CEN TERLI NE CA TCH BASIN FLOW LINE (GUTTER) INVERT ELEVATION MANHOLE RI GTH-- OF--- WA Y REINFORCED CONCRETE PIPE STORM DRAIN SEWER STA TION TOP OF CURB VITRIFIED CLAY PIPE WA TER CENTERLINE RIGHT-OF-WAY WA TER SEWER ELECTRIC GAS TELEPHONE EA SEMEN T FIBER OPTIC 0' 12' 13 TSTAGING AREA 2.0% FUTURE AC PAVEMENT FUTURE MED. CURB 28' FUTURE SOUTI-VLA T R/W 1 10' p p FUTURE LANDSCAPE EASEMENT jam/ �SFUT. CONC. SIDEWALK FUTURE CONC,. CURB & GUTTER `CONTRACTOR SHALL PROTECT AND SUPPORT ALL EXISTING UTILITIES AND Rl TRENCH DETAIL PROVIDE SHOP DRAWINGS APPROVED BY A CIVIL ENGINEER FOR SUPPORT OF FUTURE SUMMIT AVENUE EXISTING PIPE CROSSING SUSPENDED TYPICAL SECTION SATISFACTION PROPOSED RCB TO THE SATISFACTION OF THE AFFECTED AGENCY" N. T S. ^ 1xMt 111� i �:, 'v � 8 i, 19 1 s , i P �,. 4' THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS, THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL., L_IABIL7Y AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE CONTRACTOR SHALL DEPEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY AL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK, C17Y OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA ATTN: BRIAN WREN 8353 SIERRA AVENUE FONTANA, CA 9.2335 (909) 350-66,32 TIME WARNER ATTN: ROD MESA 1500 S. AUTO CENTER DRIVE ONTARIO, CA 91761 (909) 975-3405 CHARTER COMMUNICATIONS .ATTN: XOCHITL ORTEGA 73.37 CENTRAL AVENUE RIVERSIDE, CA 92504 (951) 343-5161 CUCAMONGA VALLEY WATER DISTRICT ATTN: RUSSEL SILVA 10440 ASHFORD STREET RANCHO CUCAMONGA, CA 91729 (909) 987-2591 FONTANA WATER COMPANY SAN GABRIEL WATER ATTN: LUIS MONTENEGRO 11142 GARVEY AVENUE EL MONTE, CA 91733 (626) 448----6183 MCI A TTN: DAN GARDEN 2400 NORTH GLENVILLE RICHARDSON, TX 75082 (909) 421-3.316 SOUTHERN CALIFORNIA EDISON COMPANY ATTN: CHRIS LORIMER 7951 REDWOOD AVENUE FONTANA, CA. 92336 (714) 7.96--9932 SCT, CALIFORNIA GAS COMPANY ATTN: BRUCE YONKERS 1981 LUGONIA AVENUE REDLANDS, CA 9.2371 (909) .335-- 7871 VERT ZON ATTN: FRANK ANGUSTAIN 16071 MOJAVE' DRIVE, BLDG. A VICTORBILLE, CA 9239.2 (760) 245---0330 CRA WFORD CANYON WATER CO. ATTN: DENNIS ALL_ARD 825.3 SIERRA AVENUE FONTANA, CA 92335 (909) 356--1815