Loading...
HomeMy WebLinkAbout4429-7BRK BRICK ic JANITOR'S. CLOSET SCHED SCHEDULE TYPICAL., OFFSET f BRZ BRONZE JT JOINT SCRN SCREEN ED) RIGID INSULATION DIMENSIONS TO FROM CENTER LINE SECT SECTION -COLUMN LINES OF STUD WALL., (L)ON) BS BOTH SOES JT FLR JOINT FILLER NON I ARE HASH MARKS _S�f�SCHEDULES 4 BTM BOTTOM L LINE OR STRUCTURAL SF SEAMLESS FLOORI,NG BLANKET INSULATION DESIGNATION C TO C CENTER TO CENTER ANGLE SGFT STRUCTURAL GLAZED FACING TILE CAB CAB I N ET LAB LABORATORY SHT SHEET F STEEL CARP CARPET, LAD LADDER Sim SIMILAR 7t< CEM CEMENT LAM LAMINKT'ED S L SLOPE ALUMINUM CEMC CEMENTITIOUS COATING LAV LAVATORY SL.NT SEALANT CF COMPRESSIBLE FILLER LG LAMINATED GLASS SPEC SPECIFICATION, SPECIFIED GROUT ACTUAL AS BUILT CONCRETE HARDENER 4, M,OJR.0� CH LKR LOCKER SST STAINLESS STEEL . .... . 2 CHAM CHAMFER LNTL. LINTEL STID STANDARD NOMINAL _jj) CAULK CHAN CHANNEL LP LIGHT POLE STL STEEL M.O. GIVEN CIP CAST IN PLACE L� P. OR (LP) LOW POINT STOR STORAGE 5'__4 5$-01v ON PLAW A-3/8" GLASS STRU STRUCTURE (S, URAL) ci CONTROL JOINT LT LIGHT �S mo CL or, CENTERLINE MAS MASON STWY STAIRWAY CLG CEILING MATL MATERIAL SUPT SUPERINTENDENT STRUCTURAL STEEL WINLQM OR LOUVER TYPIQAL,.jL0QR LO�!A ()N� CLKC CAULKING MAX MAXIMUM SUSP SUSPENDED DEE U _� _Tt ___ -NINQ IN PLAN FOR S1 D FRAMED WALLS T RE AD ��S) SHEET METAL, STEEL.-, CMU CONCRETE MASONRY UNiT MEMB MEMBRANE T COL COLUMN MFR MANUFACTURER TBM TR BEARING MEMBRANE GLASS, WATERPROOFING Comp COMPRESSIBLE MIN MINIMUM T&G TONGUE AND GROOVE CONC CONCRETE MISC MISCELLANEOUS TEL TELEPHONE CONT CONTINUOUS MO OR M.O. MASONRY OPENING TEMP TEMPERATORE CRC CHEMICAL RESISTANT COATING MR MOISTURE RESISTANT TEMP TEMPERED CR CLEANROOM MRAT MOISTURE RESISTANT ACOUSTICAL TILE ­r'E M P TEMPORARY CRS COURSE MTD MOUNTED TER TERRAZZO CT CERAMIC I E MTG MOUNTING TERB 'TERRAZZO BASE 11NE-TYPES ...LiNLEsss OPENINGS ARCHITECTURALSHEETINDEX DET DETAIL MTL METAL THK THICK(NESS) USUALLY LABELLED IN PLAN VIEW; HOWEVER, OFIENtNGS 'NOT SHOWN IN PLAN ARE LABELLED ON ELEVATIONS DF DRINKING FOUNTAIN N/A NOT APPLICABLE THR THRESHOLD A-1 SYMBOLS, NOTES, AND CODE SUMMARY DIA DIAMETER NC NON COMBUSTIBLE TKBD TACKBOARD CONTINUOUS -- NEW CONSTRUCTION A-2 CODE PLAN AND LEGEND DIAG DIAGONAL NIC NOT IN CONTRACT' TOIL TOILET' DIM DIMENSION NOM NOMINAL TOPG TOPPING DASHED ON CONSTRUCTION PLANS/SHEETS D 2 22 DISP DISPENSER NTS NOT TO SCALE TOS TOP OF STEEL HIDDEN ELEMENTS ABOVE, BELOW, OR BEYOND A- 3 DEMOLITION PLANS, SECTION AND NOTES DN DOWN oc ON CENTER OR OVERHEAD COILING TS STRUCTURAL TUBING (STEEL UNLESS NOTED) DOOR DESIGNATION I -SEQUENTIAL. LETTER DESIGNATION A---4- FLOOR AND ROOF PLANS DO OR D.0, DOOR OPENING OD OVER FLOW ROOF DRAIN TS L TOP OF SLAB ASSIGNED TO EACH ADDITIONAL DOOR DP DAMPROOFING OPNG OPENING TWF THROUGH WALL FLASHING A-5 ELEVATIONS AND SECTIONS DR DRAIN OPP OPPOSITE Typ TYPICAL, L A- 6 WALL SECT]ONS AND DETAILS DWG DRAWING OPP HD OPPOSITE HAND uc UNDERCUT NUMBER EA EACH ORD OVERFLOW ROOF DRAIN UON UNLESS OTHERWISE NOTED A- 7 SCHEDULES AND DETAILS El- ELEVK'nON OSB ORIENTED STRAND BOARD UL UNbERWRITERS LABORATORIES iNCORPORATED ELEC ELECTRICAL OVHD OVERHEAD VB VAPOR BARRIER ELEV ELEVATOR PERIM PERIMETER VCT VINYL COMPOSITION TILE EQ EQUAL _(LY') PL PLATE VERT VER FI CAL EQPT EQUIPMENT PLAS PLASTER VTR VENT THRU ROOF" SYMBOLS EWC ELECTRIC WATER COOLER PLK P LAN K w WIDE EXP EXPANSION PLYWD PLYWOOD W/ WITH EXP EXPOSED Pm PRESSED METAL W/A WHERE APPLICABLE _o� EL 1058�75' EJ EXPANSION JOINT PR PAIR W/o WITHOUT SUFRX A,B,C ETC. W/A C-1) EXIST or (E) EXISTING PR PRETREATED WATER SYSTEM Wc WATER CLOSET PREFIX BUILDING DESIGNATION SEE NOTE ON PARTITION - ELEVATION NO ELEVATION TAG (IF APPLICABLE) FOR INFORMATION OR C) FAC -FACTORY FINISH PRD PROMENADE ROOF DRAIN WD WIDTH -.-FIRE RESISTANCE RATING) 6- A'� FID FLOOR DRAIN PRCST PRECAST WD WOOD 1 2 [T:fS)2 ROOM NUMBER FE FIRE EXTINGUISHER PREFAB PRE-FABRiCATED WDW WINDOW 7! A-4 \8� INTERIOR ELEVATION 7- FGL. FIBERGLASS PT PRESSURE TREATED WF WIDE FLANGE _J 7 - A PARTITION TYPE Ld FIN RNISH(ED) PRMLD PREMOLDED WPG WATERPROOFING 9 DWG NO > FLG FLASHING' PSF POUNDS PER SQUARE FOOT WT STEEL TEE ---SHAPE DESIGNATION FE R_ FLOOR(iNG) PTD PA�NTED WWF' WELDED WIRE FABRIC NOTE-., SEE WALL SECTIONS FOR BUILDING SECTION WALL SECTION DETAIL FLR FILLER QT QUARRY T1 LE ADDITIONAL REQUIREMENTS INDICATOR iNDICATOR INDICATOR FIR FRAME QTB QUARRY TILE BASE FO FRAME OPENING R RISER�S,) COLUMN TAG F -IRE EX'flNGUISHER FV FIELD VERIFY RAF R/ ACCESS FLOORING & CENTER LINE FXD FIXED RB RUBBER BASE 'ef. 0 z -A < GENERAL NOTES -CALIFORNIABUILDING CODE SUMMARY,. I U - 1, HEIGHT OF. INTERIOR PARTITIONS ARE FROM FLOOR 1-0 THE UNDERSIDE OF DECK KEY DETERMINATIONS: TYPE. REQ, _UIREMENT: CODE REFERENCE: APPLICABLE -ORDINANPES, CODES �AND STANDARDS- (.)NLESS OTHERWISE NOTED, PROVIDE DEFLECTION HEADS AT TOP OF WAL[_S (TYPICAL). USE GROUP: GROUP F (FACTORY� AND INDUSTRIAL.), SECTION 306.1 FtRE �RESJSTIVE RATING: A. PLANN�NG &'ZONING: SAN BERNARDINO COUNTY 2� NOT ALL EQUIPMENT IS SHOWN FOR CLARITY. REFER TO THE APPROPRIATE DESCRIPTION DIVISION 2, LOW ­HAZARD TABLE 3-13 BEARING WALLS (EXTERIOR) 0--i-iOURS REQUIRED TABLE 6-A ZONiNG ORDINANCE CURRENT E.-DITION Et", (L.) DISCIPLINE SHEETS FOR SPECIFIC EQUIPMENT AND UTILITY LAYOUTS. BEARING WALLS (INTERIOR) O -HOURS REQUIRED TABLE 6--A B. BUILDING CODE: CAUFORNIA CODE OF REGULATIONS (CCR), -nTLE 24, PART 2 3, SEE CIVIL SHEETS FOR SITE ELEVATIONS, SIDEWALKS, PAV�NG, FENCE AND LANDSCAPING. CONSTRUCTION TYPE II -N NONCOM BUS"TIBI-E MATERIALS SEC"TION 603.1 NONBEARING WALLS (EXTERIOR) O -HOURS REQUIRED CALIFORNIA BUILDING CODE, 2001 EDITION TABLE 6-A C. MECHANICAL CODE. CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 24, PART 4 Ll I 4� SEE STRUCTURAL SHEETS FOR SIZE AND LOCATION OF CONCRETE PADS, TRENCHES, STRUCTURAL FRAME 0 -HOURS REQUIRED TABLE 6---A CAL[FORNIA MECHANICAL, CODE, 2001 EDrn0N VAULTS, SUMPS, ETC, R E L�a_Q:L. E--EE a.: _JL j PARTITIONS (PERMANENT) 0 -HOURS REQUIRED I -ABLE 6--A D. PLUMBING CODE: CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 24, PART 5 2_ 0 5. SEE STRUCTURAL SHEETS FOR CONCRETE AND MASONRY REINFORCEMENT. OCCUPANT LOAID�, SHAFT ENCLOSURES I -HOURS REQUIRED SECTION 71f If CALIFORNIA PLUMBING CODE, 2001 EDiTION 6. PATCH AND REPAIR ANY MATERIALS C)R SURFACES DAMAGED DURING THE CONSTRUCTION OVERALL BUILDING 6 OCCUPANTS (100 SO.FT'./PERSON) SECTION 1003.2.2 f`_L,00R/FL00R­C0LINGS O -HOURS REQU�RED I -ABLE 6-A E. ELECTRICAL. CODE: CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 24, PART 3 0`1 L__ OR DEMOLITION PROCESS 'TO MATCH THE ADJACENT SURFACES (TYPICAL), BASED ON 590 SQ.FT. BUILDING AREA TABLE 1 O -A CALIFORNIA ELECTRICAL CODE, 2001 EDITION ROOF/ROOF--CEILINGS O -HOURS REQUIRED T'ABLE 6-A F FIRF MnF� (NAt M7)PNIIA r,,c)ni7- nr, Pri­,l It ATtnt\[Q T i T1 F.- D A DA OT 0