HomeMy WebLinkAbout4063-2KwAkwooMm"
IRRIGATION LEGEND
EQUIPMENT LEGEND
SYMBOL.
MANUFACTURER/MODEL #
SIZE
DETAIL
N OTES
F
IRRIGATION WATER METER - BY OTHERS
1 1/2vv
PER CITY
(VALVEA-15@20GPM)
NIBCO T585 BALL VALVE 2" & SMALLER
LINE SIZE
tC74
(2,3,5)
LOSS THRU 1 1/2 WATER METER
TORO SENTINA,L CONTROLLER INSTALLED IN STAINLESS STEEL EDISON METER BOX
16 STA.
'C,D,EF/3
(2,3,4)
LOSS THRU 2 B/F DEVICE
ENCLOSURE� MODEL # ESB36-U2-MPEA16'l0K-0Bl-'VRA CONTACT TOM RADEN AT AQUA
LOSS THRU 550'OF 2" MAIN
FL'i: 5)895 -8909FAX- 661 718-0192�
"LLBTU
left
" J�l
LOSS THRU GATE VALVES (2 QTY)
"VALVE
SUPERIOR 950 -DW ELECTRIC CONTROL VALVE
PER PLAN
'Cf/A3
(2,:3)
x
FEBCO 825Y REDUCED PRESSURE BACKFLOW
1 1/21#
W/3
(1,2,3)
RAINBIRD QUI CKCOUPLER33DLRC' HOUSED IN A 10" ROUND LOCKABLE
ff
�Bt/4
(2,3)
PLASTIC VALVE BOX
LOSS THRU LATERAL LINES
Z1 PSI
(a,
SPARE PILOT WIRES, COLOR TO DIFFER FROM SITE WIRING INSTALL IN A 12xl8 VALVE BOX
#14 PILOT
'G73
(2,3)
EO-
RAINMASTER EVFM-P200 FLOW SENSOR
LINE SIZE
'B73
(2,3)
1 �o PSI
2" CLASS 315 PVC MAINLINE - 18" MINIMUM COVER
2"
DA74
(2,3)
TOTAL SYSTEM LOSSES
CL 200 PVC NOWPRESSURE LATERAL LINE - 12" MIN. COVER
PLAN SIZE
W/4
(2,3)
SCH 80 PVC IRRIGATION PIPE / SCH 40 WIRE SLEEVE - 24" MIN. COVER
SEE CHART
'G'/3
NOT SHOWN
UF RATED CONTROL. WIRE, 112 GA COMMON, 14, GA PILOT - 18" MIN. COVER, INSTALL IN A
12/14 GA
44
12" X 18" VALVE BOX
67 PSI
(1) INSTALL BACKFLOW PREVENTER IN GROUND COVER OR SHRUB AREA ONLY AND PARAI-LEL TO STREET.
2,1
L
SEO. #
S
'�W
_'VALVE
(2) PIPES AND VALVES ARE SHOWN IN HARDSCAPE FOR CLARITY ONLY,
J
FLOW
(3) ALL MAINLINE TEES AND 90'S ARE TO BE SCH 40 PVC�
_pM
(4) COORDINATE ELEC, POINT'OF CONNECTION WIT[i ELECTRICAL CONTRACTOR.
VAFV�'
(5) VALVES TO TO BE HOUSED IN A 10" ROUND LOCKABLE PLASTIC BOX.
1/2" PIPE
SlZiE
(6) CONTRACTOR SHALL ADJUST HEADS WHEN VERTICAL OBJECTS (TREES,FIRE HYDRANTS, STREET LIGHTS, ETC) W-rERRUPT
3/4" PIPE
'THE SPRAY PATTERN OF THE SPRINKLER. THE CONTRACTOR SHALL INSTALL A QUARTER OR HALF CIRCLE SPRINKLER
HEAD
TO ACHIEVE HEAD TO HEAD COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITION COSTTO
THE OWNER.
NOTE- ALL VALVE BOX COVERS TO BE CARSON/BROOKS GREEN VALVE BOXES OR EQUAL.
PRESSURE LOSS CALCULATIONS
(VALVEA-15@20GPM)
LOSS THRU 1 1/2 WATER METER
2.8 PSI
LOSS THRU 2 B/F DEVICE
10.0 PSI
LOSS THRU 550'OF 2" MAIN
23 PSI
left
" J�l
LOSS THRU GATE VALVES (2 QTY)
"VALVE
2.0 PSI
LOSS THRU 1
3�1 PSI
Ool,
3
LOSS THRU LATERAL LINES
Z1 PSI
ELEVATION LOSS
-0.9 PSI
MISC. LOSS THRU FITTINGS
1 �o PSI
TOTAL SYSTEM LOSSES
22.4 PSI
PRESSURE REQUIRED AT HEAD
30 PSI
44
REGULATED STATIC PRESSURE
67 PSI
2,1
J
SCH 40 PVC SLEEVING
CHART
"1 114 "SLEEVE 1-4 WIRES
1/2" PIPE
12" SLEEVE 5-10 WIRES
3/4" PIPE