HomeMy WebLinkAbout4195-1VICINITY MAP
N.T.S.
RCE SIGNITURE DATE
CITY-
TH
0.
F _ON,.TA�
A
STREET
U E
6','_572
IMPR-OVEMENT
ALMERI.A
PROJE--CT
SO-�J
TH
H
I GH LAN
D AVEN
U E
6','_572
ALMERI.A
A'VENUE
PROJECT LOCATION
FOR
STREETIMPROWMENT PLANS
1. ALL WORK S14ALL BE IN ACCORDAikt WITH TREsE. PtxNs,'n,4E ciTy OF FONTANA STANDARD
PLANS, THE CONTRACT PROVISIONS AND TUE STANDARD SPECIFICATIONS. FOR PUBLIC WORKS
CONSTRUCTION (-GREEN BOOK"). ALI. REFERENCE SPECIFICATIONS -ANID STANDARDS -SHALL BE
THE LATE- ST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECI-INICAL CONFLICT IS FOUND TO 7XIST IN THE. CONTRACT DOCUMENTS THAT CAN
NOT BE RESOLVED BYREFERENC� TO PRECEDENCE PROVISIONS IN THE "ORF113N BOOK", THE
CONTRACTOR SFTALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR
3. ALL MATERIALS ANY) NIE"ITIODS ARESUBJECTTO THE -APPROVAL OFTHE, CITY FNGINEERI.
4. CONSTRUCTION PERIMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY
DEVELOPMENT DEPARTMENT. ENGINEERING DIVIS10N PRrOR TO THE START OF ANY WORK.
-QUESTED AT LEAST -17WQ WORKING DAYS PRIOR �m THT.-
INSUIECTION COORDINATION SHALL 13E R17 S
START OF ANY WORK IN PUBLIC RtGHT-OF-WAY WITHIN TME CITY LIMITS. CAI'l, (90.9) 350-7610,
5� THL CONTRACTOR SUALL CONFORM TO' ALL TRAFFIC CONTROL POLICIES. Mil"I'MODS AND
PROCEDURES DESCRIBED IN THE STATE Of-, CALIFORNIA MANUM, Or, TRAFFIC CONTROLS, LATEST
NON-M,ETRic FDFI ION UNLESS OTHE'RWISE DIRECTFI) BYTHECIl'YTRAFFIC EN I E -.R
6. 11' SHALL BE THE'RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DFVICES AT ALLTIMFS.
7. THF -CONTRACTOR SHALL OBTAIN A PE.,RMIT TO'PERFORNI EXCAVATION ORTRENCH WORK FOR
TRENCIIES 5 FEET OR GREATER IN DEPTH FROM Tlffl� CALIFORNIA STATE DIVISION OF
INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF All. EXCAVATIONS (APATER THAN, Fivr.. (5) E'r IN J)E PTH S HALL
BEo GUARDED BY SHORING .-SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO
T.1-16 REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA.
TRENCHES LESSTHAN FIVE (5) FEETSHALL ALSO BE GUARDED WHEN POTE.NTIAL rxlSTs ]-,olz
GROUND MOVEMENT,
9. NO MATERIAL OR EQUIPMENT SHALL BE STORRD� IN THE, PUBLIC RIGHT OF WAY WITHOUT
OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE,.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE, BEEN DETERMINED FROM AVAILABLE
INFORMA'rioN, HowuwF.m, iTSHALL Bl-'I*.Hl,'ItT-,SPOiN,�IBII,TrYOF'ri-IT�., CON'TRACTOR TO DETERMINF,
IN THE FIELD, THSTRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES.. AND TO
EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRjkCTOR SHALL
CONTACT UNDFRGROUND �E'RVICF' ALERT AT 1-800-227-2600 TWb WORKTNG; DAYS BEFORE'
E XCAVA'rioN.
1.1, THR' CONTRACTOR SHA 1A, COORDINATE, CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT L]Mrl'CD TO, QAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
LANDSCAPING ',- LANDSCAPE IRRIGATION. DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM
DRAIN, FLOOD CONTROL AND CALTRANS. ALI, UTJLn'Y COMPANIES SHALL BE OWEN TWO
WORKING DAYS NOTICE PRIOR TO WORK AROUND TTIEIR FACILITIES,
12. THE CONTRACTOR SHALL NOT' OPERATE ANY FIRE HYDRANT OR WATER MTAIN VALVES
WITHOUT APPROPRIATE AGENCY AUTHORIZATION. coNuRAGFOR SHALL COORDINATE WITHTHE
APPROPRIATE WATER COMPANY FOR VALVE OPBRATION AND WATER REQUIREMENTS.
13, CURVE DATA REFERSTO THE FACE OF CURB.
14. STATIONING REFERS TO'll-lE CENTERLINE OF STREE'rS EXCErr WlIEREartiERWISE 'NOTED.
15, ADEQUATE, CONSTRUcrioiq CONTROL STAKES STIALL BE SET BY THE ENGINEER TOENABLE
THE CQN'iRAc'rORT0 CONSTRUCTTHEWORKTOTHE PLAN GRADES, THE CONTRACTOR SHALL BE
RESPONSIBLE FORTHE PRESERVATION OF BENCHIMARKS AND CONSTRUCTION CONTROL sTAKFNIG
DURING CONSTRUCTION.
1'6. THE CONTRACTOR SHALLNOT DISTURB EXISTINO SURVEY MONUMENTS, MONUMENTTIES OR
BFINCH MARKS WITHOUTPRIOR NOTIFICATION TOTHE ary ENGINEEIA,
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY
MONUMEN'IS, MONUMENTTIES AND BENCH IMARKS, SHALL 3h.' DONE BY A RE.�QISTERED CIVIL,
E.NGINBER, OR LICENSED LAND SURVFYOR- SURVEY MONUMENTS THAT WILL BE, DESTROYED AS A
RESULT' OF THIS CONSTRUCTION SHALL BE: REPLACED. TRE CONTRACTOR SHALL NOTIFY THE
ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE
ESTABLISHED FORLATER REPLACEMENT OF TIlE MONUMUNT.
18, THE CON,rRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES ATALL
TIMES� ' A MINIMUM 12 FOOT IAN2 SHALL BE MAINTAINED ATALLTIMES IN THE CONSTRUCTION
AREA FOR RESIDENTS AND EMERGENCY �lf'EJIICLES,
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF Dus*j, coNTRoL.
INCLUDING ADEQUATE'WATERINCY, ATALLT[MES.
20, ALL GRADING OPERATIONS SHALL BE DISCONTINUED WHEN SUSTAINED -WIND VELOCITIES
ElXCEFID 25 MILFS PE �R HOUR.
2-1. THE CONTRACTOR SHALL NOTCAUSEANY EXCAVATED MATERIAL, MUD.. SILTOR DEBRISTO
Bg Tm,osiTED ON'TO PUBLIC OR PRIVATE PROPEWFY ADJACENTTO THE RIGH'TOF WAY DURING
CONSTROCTION WITHOUTPRIOR WRI17FN APPROVAL.
22. NO- TRENCH' BACKFILL SHALL TAKE PLACE WITHO'U'r PRIOR APPROVAL OF THE CITY
INSPE�CTOR�
23. A GEOTECHNICAL 2NCYINEER SHALL CFRTIFY ALL BACKFILL COMPACTION. FAILURE TO
OBTAIN'THF REQUIRED DENSITY SHALL RE'QUIRE RE-WORKINa OF THA:r POR�TION OFTHF WORK
TJNTIL THE , SPECIFIED DE NSITY IS OBTAINED.
24. CARE SHOULD BETAKENTO PREVENTGRADES, Drl'CFIES, AND SWALES FROM'UNDERMINING
sTizu.'T IMPROVEMENTS. UPON INSPFcrtON OFTHE -mF. CITY ENOINFER MAY RFQUIRh
TEMPORARYNON-FRODEABLE, SWALFS.ENTRAING ORA,FAVI�G, IMPROVEMENTS.
25, THE FINAL. LOCATIONANT) WIDTH OFDRIVEWAY APPROACH APRONS SHALL BPAPPROVED A-TTI-Icl TIME OF CONSTRUCTION
AND SHALLCONFORM TO THE CITY OF FONTANA STANDARD DETAILS.
26, ATA. E'XPOSED CON CRETE' S URFACES STIALL CONFORM IN GRADE', COLOR AND FINISH 1-0 MATCH EXISTIN(j- CONCRETE.
27. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE PACE OrTHE CURB ATTRE LOCATION OF THE SEWER LATERAL.
28. NO CONCRETE SlIALL BE PLACED UNTILTHE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVE -D.
29, ALL UNDERGROUND UTITATIE'S SHALL BEZINSTALLED. TESTED AND APPROVED PRIORTO PAVING OFSTRE'ETS,
30. APPROVED SOfL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACE IM ENT.
31. 11AVEMENTSTRUCTURAL SECTIONS SHOWN ARE MIN41MUM' AND SUBJECTTO REVISION AND APPROVAf. rlFTHE CrI'Y ENGINEFR
AS DE'FERMJNI--'D BY SOILS TESTS TAKEN AFTER COMPLETION OF ROUGH GRADING.
32, ACTUALTHICKNESS OF A.C. PAVEMENTANDIOR BASE couRsE mNrERIAL FOR STRUCTURAL STREET SECTIONS SHALL BE
RECOMMENDED BY A GEo'rECHNTCAL RETOR7 AND SUBMITIT'DToTHE CITY OF FONTANA FOR APPROVAL UPON COMPLETION OF
ROUGI-I GRADING.
33, ALL MANHOLFS, CLEANOUTFRAMFS, COVERS AND VALVE BOXT,"S SHALL BE, RAISEDTO FINISHED GRADE BYTHh PAVING
CONTRA(JOR UPON COMPLETION OFPAVING.
34, OPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL.RESTORE ALL SIGNING, sT�RIPING, BARRICADES, AND OT14r,,R
J'RAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITYTRAFFIC ENGINEER.
35, CONTRACTOR SHALL RELOCATE ANINOR REPIACE LANDSCAPING, SPRINKLERS AND SIDFWALKS AFFE'criu> BY'rHE
CONSTRUCTION TO THE SA�ISFACTION Or THE CITY ENGINEER.
30. AS-BUILTDRAWINGS SHALL BE'. PROVIDEO) BY'FHI"CONI'RAC�.rOR'1'0'rl4l,.I-',NCiiNr,,T-.'ItOl-, RECORD. WHO SHALL PROVIDE. RECORD
DRAWING$ TO THE CITY ENGINEER.
mm
m
p
REMOVE EXISTING AC SID
PROTECT EXISTING C&G
R/w
PROPOSED
PROPOSED CONIC
PARKWAY SIDEWALK
14'
SOUTH HIGHLAND AVENUE
TYPICAL SECTION
0.5'
2.1 ON4
SOUTH -HIGHLAND 2 STATION 10+00 TO STATION 11+03
Lij
Li
Q_
Li
0
0�_�
CL
:�i
F_
LLJ
L -1i