Loading...
HomeMy WebLinkAbout4085-1VICINITY MAP north CONTRACTORS RESPONSIBILITY FOR SAFETY: IN SUBMITTING A BID FOR THIS WORK, THE CONTRACTOR AGREES HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER, THE ENGINEER AND THE GOVERNMENTAL AGENCY HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER, THE ENGINEER, OR GOVERNING AGENCY. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT EMPLOYEES ARE PROVIDED A SAFE PLACE TO WORK AND THE PUBLIC IS PROTECTED. THE CONTRACTORS AND SUBCONTRACTORS SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S. DEPARTMENT OF LABOR WITH "CONSTRUCTION SAFETY ORDERS". THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS OR SUBCONTRACTORS COMPLIANCE WITH SAID REGULATIONS AND ORDERS, in M���Nkl ullllv��W 0 1 THE EXISTENCE AND APPROXIMATE LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES OR STRUCTURES EXCEPT AS SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO LIABILITY AS TO THE EXACT LOCATION NEITHER OF SAID LINES NOR FOR UTILITIES OR IRRIGATION LINES WHOSE LOCATIONS ARE NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL UTILITY AND IRRIGATION COMPANIES PRIOR TO WORK ON EXCAVATION TO DETERMINE EXACT LOCATION OF ALL LINES AFFECTING THIS WORK, WHETHER OR NOT SHOWN HEREON, AND FOR ANY DAMAGE OR PROTECTION OF THESE LINES. THE CONTRACTOR SHALL CALL IN A LOCATION REQUEST TO UNDERGROUND SERVICE ALERT (USA) PHONE 800-22-7-2600 TWO WORKING DAYS PRIOR TO DIGGING, NO CONSTRUCTION PERMIT ISSUED BY PUBLIC WORKS DEPARTMENT SHALL BE VALID INVOLVING UNDERGROUND FACILITIES UNLESS THE APPLICANT HAS AN INQUIRY IDENTIFICATION NUMBER ISSUED BY U.S.A. BASIS OF BEARINGS. - BEARINGS ARE BASED ON THE CENTERLINE OF SIERRA AVENUE BEING NORTH 00"32'56" WEST PER PARCEL MAP NO. 12195 P.M.B. 158/28-40 SPSN BM # 0063 ELEV = 1087.4030 NGVD 29 BRASS DISK IN WINGWALL AT CITRUS AVE. AND S.P.R.R. TRACKS, 76 FEET EAST' OF CITRUS, 52 FEET SOUTH OF SOUTH RAIL, IN EAST END OF SOUTHEAST WINGWALL OF CITRUS OVERPASS, 1 MILE WEST ALONG S.P.R.R. FROM SIERRA AVE. OVERPASS. U.S. POSTAL SERVICE 395 OYSTER POINT BLVD. SUITE 225 SOUTH SAN FRANCISCO, CA 94080-0300 ............ UTI LITI ESio-, WATER: FONTANA WATER COMPANY TRACT 9862 S A N T A APN 255-010-25 U.S.P.S. POST OFFICE Lij m C) A V E N U E SHEET INDEX SHEET NO. TITLE SHEET 1 . . . .. .......... . . STREET SIGNAGE AND STRIPING PLAN 2 - - — - --------------- SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WI`TH STANDARDS IN EFFECT. PROPERTY UNE north KEY MAR N.TS. SIGNING AND STRIPING GENERAL NOTES 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 2. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, DIMENSIONS, AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST EDITION. 3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAYS PRIOR TO REMOVAL OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL. 4. ALL WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE 2003 MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND THE 2003 MUTCD CALIFORNIA SUPPLEMENT. 5. 2 WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY TRAFFIC ENGINEER (909) 350-7610 FOR APPROVAL OF CONTROL POINTS OR "CAT --TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING. 6. TRAFFIC SIGN SIZE SHALL. BE FOR CONVENTIONAL ROADWAYS, UNLESS OTHERWISE SHOWN ON PLANS. 7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 4008. 8. STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS. 9. ALL STRIPING AND PAVEMENT MARKINGS SHALL. BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. 10. CROSSWALKS SHALL. HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 1006. 11. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTODESK CAD FILES, TO THE CITY TRAFFIC ENGINEER. 12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING. 13. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD PLAN. TELEPHONE # (909) 822 - 2201 SEWER: CITY OF FONTANA 3 U4 APPLY THERMOPLASTIC, DETAIL 27B, EDGESTRIPE. TELEPHONE # (909) 350 - 6632 ELECTRIC: SOUTHERN CALIFORNIA EDISON COMPANY 271.00 TELEPHONE # (800) 655 - 4555 GAS: SOUTHERN CALIFORNIA GAS COMPANY INSTALL TYPE F DELINEATORS AT 25' SPACING. TELEPHONE # (800) 427 - 2200 TELEPHONE COMPANY: PACIFIC BELL CO. 228.49 TELEPHONE # (800) 750 -- 2355 TRACT 9862 S A N T A APN 255-010-25 U.S.P.S. POST OFFICE Lij m C) A V E N U E SHEET INDEX SHEET NO. TITLE SHEET 1 . . . .. .......... . . STREET SIGNAGE AND STRIPING PLAN 2 - - — - --------------- SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WI`TH STANDARDS IN EFFECT. PROPERTY UNE north KEY MAR N.TS. SIGNING AND STRIPING GENERAL NOTES 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 2. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, DIMENSIONS, AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST EDITION. 3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAYS PRIOR TO REMOVAL OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL. 4. ALL WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE 2003 MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND THE 2003 MUTCD CALIFORNIA SUPPLEMENT. 5. 2 WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY TRAFFIC ENGINEER (909) 350-7610 FOR APPROVAL OF CONTROL POINTS OR "CAT --TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING. 6. TRAFFIC SIGN SIZE SHALL. BE FOR CONVENTIONAL ROADWAYS, UNLESS OTHERWISE SHOWN ON PLANS. 7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 4008. 8. STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS. 9. ALL STRIPING AND PAVEMENT MARKINGS SHALL. BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. 10. CROSSWALKS SHALL. HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 1006. 11. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTODESK CAD FILES, TO THE CITY TRAFFIC ENGINEER. 12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING. 13. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD PLAN. STRIPING CONSTRUCI -ION NOTES APPLY THERMOPLASTIC, DETAIL 22, CENTERLINE STRIPE. APPLY THERMOPLASTIC, DETAIL 6, CENTERLINE STRIPE. 601TS L. F. L. F. QUANTITY 250.00 205.4-5 U3 APPLY THERMOPLASTIC PAVEMENT MARKING, AS SHOWN. EACH 3 U4 APPLY THERMOPLASTIC, DETAIL 27B, EDGESTRIPE. L. F. 110.00 APPLY THERMOPLASTIC CROSSWALK. L. F. 74.35 APPLY THERMOPLASTIC, DETAIL 2, CENTERLINE STRIPE, L. F. 271.00 U7 . ......... INSTALL Rl-1 SIGN PER CITY OF FONTANA STD. NO, 4008. EACH 1 U8 REAPPLY THERMOPLASTIC LIMIT LINE. L. F. 49.00 U9 INSTALL TYPE F DELINEATORS AT 25' SPACING. EACH 3 INSTALL Wl -6(L) SIGN AS SHOWN. — - ------------ EACH 1 PAINT TEMPORARY EDGESTRIPE DETAIL. 27B. L. F. 228.49 PAINT TEMPORARY CHEVRON STRIPE AT 25' SPACING. L. F. 128.14