HomeMy WebLinkAbout4077-58(I)SAME SIZE (g) FLEXIBLE DUCT TO CEILING TO CEILING q)CLAMP (NO DUCT TAPE) SPAQE SPACE '.(g)MANUAL BALANCING DAMPER 2Ox2O LINED SA UP TO BELOW. TRUSSES (g)45* LATERAL BRANCH LOCATION OF FLEX CONNECTION 22x18 LINED RA UP cn \:E7 ANCHORS. SEE TO BELOW TRUSSES @MAIN DUCT OUTLINE OF�"�.- EQUIPMENT DETAIL BELOW. (TYP. INLET AND OUTLET) 4�- MAIN AIR COOLING COIL DUCT / �cc SoAo C4) L EQUIPMENT PLAN ';��7 1 1 FILTER RACK SECTION FURNACE BASE F 29x2"'xl/,V' GALV. ANGLE PROVIDE COLLAR FOR NOTE-. DUCTCONNECTON L=1 /4 W (40# MINIMUM.) CONC. PAD 18 GA x 3*' ANCHORED PLATE SECURE FAN COIL TO FRAMING TRANSITION IN 456 LENGTH AS REQUIRED WTH 3/8"0 BOLTS, WASHERS, VERTICAL (BEYOND) AND NUTS PER CORNER -Z2Z= SECURE CONC. \0 PAD WITH PHILLIPS REDHEADS. W (8) 5/8"0 x 3" LONG PROVIDE 1/4"x3" SQUARE PLATES AT BOTTOM OF FRAMING V FELDED TO STRUCTJRE. SECURE R, AIMING TO RA PLENUM AND FAN COIL SUPPORT WITH FLOOR WITH 3/8"0 ANCHOR BOLTS, MINIMUM 1 -1/2"x1 -1/2"x1/4" FRAMING AND CROSS BALANCE DAMPER IN EMBEDMENT = 2-1/2" (TYP EACH CORNER)i BRACING, WELDED CONSTRUCTION SUPPLY AIR TAKE—OFFS AND WHERE INDICATED PROVIDE LINED 24 GA SHEET ON DRAWINGS. AIR BRANCH METAL ALL AROUND FRAMING SUPPORT. SEAL AIRTIGHT DUCT (TYPICAL) DUCT TAKE -OFF DETAIL SCAL SCALE SCALE E NONE 2 FURNACE INSTALLAT10i\4 D ETAI L IIIONE73 CONDENSING UNIT MOUNTING I ± NONE] VENT CONCENTRIC VENT COMBUSTION AIR 00 45' MAX. STORM COLLAR 12" MIN. FLASHING, SEE ARCH. SECURE W/1/2" GALV. BOLTS. (TYP. OF 4) DRAWING COUNTER FLASHING FLEXIBLE DUCT ROOF CAP CLAMP ROOF STRUCTURE WATER PROOF SEALANT CONTINUOUS. FOR FLASHING REQUIREMENTS SEE ARCH. PLANS. SQUARE TO ROUND ADAPTOR ROOFING AS PER ARCH. D'WGS 2 r— OPPOSED BLADE DAMPERS 2 5 ADJUST FOR SLOPE. ri DIFFUSER OR GRILLE DRESDEN METAL ROOF STRUCTURE DRYWALL/HARD—LID CEILING SEE STRUCTURAL PLANS FOR CONSTRUCTION. V SEE ARCHITECTURAL RCP EXHAUST DUCT THROUGH ROOF rr 6 6 5 INTAKE/COMBLISTION AIR EXHAUST/VENT SCALE SCALE SCALE ROOF CAP DETAIL L NONE d6 CEILING DIFFUSE__R____ REGISTER DETAIL NONE 5 CONCENTRIC FURNACE VENT DETAIL NONE 4 120/10/60 HZ 120/10/60 HZ NO. UNER INTERIOR CONDENSING UNIT PINS WIDTH LAPPED & BUTTED 0 §0"o DN. ORNER DISCONNECT DISCONNECT 2 9-16 3 17",2r SWITCH SWITCH 4 2 "-40" 5 47"-52" 208V/30/60HZ 6 53"-64" ACOUSTIC DUCT LINER 7 65"-76" NON—FIBERGLASS 1-1/2- THICK BY DIVISION 15 8 77"-88 EXHAUST EXHAUST SUPPLY ,-PROGRAMMABLE 9 89 0 —100" FAN FAN a BY DIVISION 16 AIR THERMOSTAT 8 EF -3 EF -1 SEQ THE VELOCITY RATED ALTERNATE WALL STAT WALL SWTCH UENCE OF OPERATION T SIDE OF LINER MUST FOLDED CORNER EF -1 A COOLING FACE THE AIR FLOW 100 4b EF -2 F/CU COIL PIN r -f- A Lr _J+ SEE gErTA)IL-8 SEE MECH. EF -5 w FURNACE/CONDENSING UNIT ASSEMBLY SHALL BE DISCONNECT SCHEDULE SWITCH N,,.ALL TRANSVERSE EDGES CONTROLLED BY ROOM MOUNTED PROGRAMMABLE DUCT SECTION TO BE COATED WITH THERMOSTAT TO MAINTAIN ROOM SET POINT BY DIVISION 16 (TYPICALLY 4 OR ADHESIVE (ADJUSTABLE). (TYP.) FURNACE 5 FEET) LINER ADHERED TOTHE TO PLYMOVENT MAXIMUM SPACING FOR FASTENERS. DUCT WITH 90% MIN. AREA CONTROL PANEL ACTUAL INTERVALS ARE APPROXIMATE. COVERAGE OF ADHESIVE 114 r, A 17 WAS E i I I I DISCONNECT SWTCH r- V/ I 1 \—CONTROL BOX VELOCITY DIMENSIONS LINER AIR FLOW A 8 C E 0-2500 FPM 3" 12" _4" 18" 12501-6000 FPM Y_ 6w- --47- BY DIVISION 16 1 BY DIVISION 15 RETUR * UNLESS LOWER LEVEL IS SET BY I AIR MANUFACTURER OR LISTING AGENCY W&DED -PIN EXHAUST FAN DUCT LINER AIR SIDE & EDGES SHALL PRESS -ON HEAD PETAIL-A EF -6 PRESSURE BE COMPLETELY FACTORY COATED UNER FaTENERS SENSOR WITH ACRYLIC MATERIAL. DETAIL -B OUTSIDE AIR 1/111-4 EXHAUST FAN CONTROL DIAGRAM SCALE 9 FURNACE /'CONDENSING UNIT CONTROL DIAGRAM SCALE DUCT LINER DETAIL SCALE 7 NONE NONE NONE CONDENSING UNIT -.105 24" MAX No TO COI L REFRIGERANT LINES OUT OF GRADE AND *---COMPRESSOR ACCESS STUB INTO WALL WITH REFRIGERANT GAUGE PIPE SLEEVE CONDENSING UNIT TOP OF CONNEC11ON SHEET METAL CENTERLINE OF THERMOSTAT SWITCH WEATHER COVER THERMOSTAT SWITCH CONTROL OUTLET. OUTLET CONTROL ACK-SEATED REFRIGERANT VALVE SEE NOTE1 x SIGHT GLASS 46" MAX WTH MOISTURE INDICATOR CONCRETE 34" MAX CONCRETE PAD FOOTING REFRIGERANT SUCTION LINE WTH INSULATION REFRIGERANT LIQUID LINE NOTE 1 FINISHED FLOOR FINISHED FLOOR CONDUIT REFRIGERANT PIPES TO CONDENSING UNIT. SUPPORT ON WOOD BLOCKS. PROVIDE STAINLESS STEEL MOUNTING HEIGHT OVER OBSTRUCTION JACKET AND INSULATION. CONDENSING UNIT DETAIL SCALE 12 REFRIGERANT PIPE TO UNIT DETAIL SCALE SCALE NONE NQNE THERMOSTAT MOUNTING DETAIL NONE Jill tkft SE, 4effe i ft 25COM4 a3c JW GM� CONSULTANT: td— T-SQUARED PRO"MIONAL ENGIWERS. INC. 1340 SPECIALTY DRIVE SUITE E VISTA, CA 92081 TEL: (760) 560-0100 F -AX: (766) 560-0101 E -Mail admin@tsqeng.com www.tsqeng.com #04091 06-07-06 ISSUE INFORMATION: DATE: I INFORMATION: MAY 2006 �E`VISION PLAN CRECK A4MAY 18v2006 REMSION SHEET INFORMATION: PROJECT NO.: SCALE: AS NOTED— DATE: DECEMBER 2, 2005 PLOT DATE: DRAWING NAME: SEAL: