HomeMy WebLinkAbout4077-50PLU M B-1 N G FIXTURE SCHE'DULE SYMEE30L SYMBOL LOCATION MIN.. PIPE SIZE I VOLTS 1 PHASE SYM. FIXTURE DESCRIPTION TOTAL FIXTURE UNITS OW MODEL 2475N5, 80 GALLON VERTICAL RECEIVER C-1 ROOM INGERSOLL-RAND CW H W v S RESIDUAL PRESSURE wc-1 WATER CLOSET FLOOR MOUNTED' 4 8 2 of 4! AMERICAN STANDARD" #2292.100, CADET ELONGATED WATER SAVER TOILET, 1.5. GAL. PER 'COVER 6 LAVATORY 4 .7 DRAIN, MAGNETIC STARTER, START UP KIT. 3 $EAT-.�.OLS0 FRONT SEAT..-WTH FLUSH..*MITE, VITREOUS NITE #95, OPEN 1 TANK TYPE, SHOWER STALL 3 2 6 -CHINA, 3 WATER CLOSET 6 EMERGENCY SHOWER 1 4 "AMERICAN STANDARD". 2168.100, CADET, ELONGATED WATER SAVER' TOILET, WC -2 FLOOR MOUNTED TANK TYPE 3/4 LOW NOX 2 4 .90 1.5 GAL.PER FLUSHs WHITE VITREOUS CHINA, ACCESSIBLEt ACTUATOR LOCATED AS PER 2.5 PROVIDE VALVES AT THE FOLLOWING LOCAT`IONS: 1 MINIMUM COVERAGE (ABOVE TOP OF PIPES) AS FOLLOWS: 2 0 ADA CLEARANCE REQUIREMENTS. OLSONITE #95 OPEN FRONT SEAT WITH COVER. 1 4 (ACCESSIBLE) 6 6 1 2 DISHWASHER 1 1.5 1.5 1.5 1 2 2 **AMERICAN STANDARD MODEL 0476-028, 16" X _10*1. VITREOUS CHINA, COUNTERTOP LAVATORY 1 LAVATORY 4 DOWN 2 ot 2 to SEAMED UNDER MOUNT9 FRONT OVERFLOW, LV`-lH (ACCESSIBLE) 3/4" 3/4" . 1 FAUCET: **CHICAGO" 2200-4 SINGLE -HANDLE WITH GRID STRAINER. PROVIDE P -TRAP INSULATION. 2 FLOOR SINK 1 CONT 4 CONTINUE PROVIDE."HANDY-SHIELD" P -TRAP COVER. 2 LAVATORY COND. RECEPTOR 1 U JURISDICTION. IN CASE OF CONFLICT, THE MORE STRICT REGULATIONS "'AMERICAN * STANDARD`* LUCERNE WALL HUNG LAVATORY MODEL 0355.01-2 20-1/2$$ X 18-1/49$ LV ­2H WALL MOUNTED 3/4" 3/4" 2 pt 2" VITREOUS CHINA9 FRONT OVERFLOW 2 (ACCESSIBLE) 1 4 4 HANDMEELS OR OPERATORS ON TOP OR ARE HORIZONTAL AND SO THAT FAUCET: '*CHICAGO" 2200-4 SINGLE -HANDLE WITH GRID STRAINER. PROVIDE P -TRAP INSULATION. 4 4 TOTAL VALVES ARE EASILY ACCESSIBLE FOR OPERATION, SERVICE, REMOVAL 63.5 'PROVIDE "HANDY -SHIELD" P -TRAP COVER. TRADES PRIOR TO START OF WORK. NECESSARY ADJUSTMENTS SHALL BE 52 AND REPLACEMENT. to BACKFILL TO A POINT 12 -INCHES ABOVE TOP OF PIPING WITH EARTH #$AMERICAN STANDARD`* STALLBROOK 6501.010, TOP SPUD, VITREOUS CHINA LOW.FLUSH. PROVIDE UR -1 WALL MTD 3/4 PRESSURE REGULATING VALVE 2 2" STAINLESS STEEL STRAINER MODEL MCGUIRE'#1233, FLUSH VALVE: ""ZURN" ZER-6003AV, 13) URINAL T RUBBISH, ROCKS, OR CLODS OVER 4 -INCHES IN THE GREATEST 5) FOR MINIMUM PIPE SIZE CONNECTIONS TO EACH PLUMBING FIXTURE SEE BATTERY POWERED INFRA -RED SENSOR, MOUNT AS PER MANUFACTURER REQUIREMENTS, AND FLOORS, ROOFS, AND WALLS. PACK OAKUM INTO THE SPACE AROUND THE (ACCESSIBLE) DIMENSION. BACKFILL ABOVE 12 -INCHES FROM TOP OF PIPING MAY BE PLUMBING FIXTURE SCHEDULE. THESE VAWES ARE MINIMUM; LARGER ADA REQUIREMENTS. (PROVIDE OWNER TO INSTALL) WITH EXCAVATED MATERIAL. APPLY BACKFILL BY HAND IN 6 -INCH DEEP CONNEC71ONS MAY RESULT BASED ON THE DIFFERENT MANUFACTURER'S THROUGH THE ROOF. $'CHICAGO" MODEL 2502, 620 SHOWER HEAD, COMPLETE TRIM KIT SH -1 SHOWER 3/4 go 3/4" MOUNT AT 6'-0" A.F.F. (SEE ARCH. DWGS.) PROVIDE THERMOSTATIC 14) ALL VENT TERMINATIONS AT ROOF SHALL BE AT I FAST 10 FEET AWAY COMPAC71ON BEFORE PROCEEDING WITH THE NEXT LAYER OF BACKFILL. MIXING VALVE SET 1207 MANUFACTURER'S NAMES AND MODEL NUMBERS SHOWN FOR PLUMBING FROM OUTSIDE AIR INTAKES, OPERABLE WINDOWS, AND THE LIKE. 9'CHICAGO"' MODEL 2502, 620 SHOWER HEAD, COMPLETE TRIM KIT 15) SHOWER 3/4 so 3/4 PLUMBING SYSTEM MAY BE SUBSTITUTED UPON APPROVAL FROM THE "'CHICAGO"' MODEL 153 HAND HELD SHOWER WITH FLEXIBLE METAL HOSE, WALL SH -2 (ACCESSIBLE) PERMITTED BY THE ARCHITECT. DO NOT BACKFILL UNTIL INSTALLED ARCHITECT AND THE OWNER. CONNECTION AND FLANGE, 24*' SLIDE BAR FOR HAND SHOWER MOUNTING AND DIVERTER PIPING HAS BEEN SUCCESSFULLY TESTED. 16) LOCATE, SIZE, AND INSTALL WATER HAMMER ARRESTERS IN ACCORDANCE VALVE. PROVIDE THERMOSTATIC MIXING VALVE SET AT 1207 "BLACK" 7) SEWER AND VENT PIPES SHALL BE AS7M A74 SERVICE WEIGHT CAST WITH PLUMBING AND DRAINAGE INSTITUTE STANDARD NO. WH -201. 24) "JUST" DL -2233 -A -GR 2 -COMPARTMENT, 18 GAUGE TYPE 304, 18-.8 STAINLESS STEEL IRON. VENT PIPES ABOVE GROUND MAY BE STANDARD WEIGHT SHALL BE AS PER UPC. COUNTER MOUNTED. KS -1 KITCHEN 3/4" 3/4" 2 09 3 so FAUCET: J -1174 -KS FAUCET WITH RECTRACTABLE SPRAY SPOUT HOSE SINK 25) ALL GAS CONNECTIONS TO GAS APPLICANCES AND EQUIPMENT SHALL BE MADE 8) HOT AND COLD WATER PIPES, AND CONDENSATE DRAIN PIPES ABOVE GARBAGE DISPOSER "INSINK-ERATOR" MODEL 444. N4 HP9 120 VOLTS, 8.1AMPS SINGLE PHASE. OF FLOOR -MOUNTED FIXTURES TO DRAINAGE CONNECTIONS AND FLOOR IN USING METAL FLEXIBLE CONNECTOR, AND SHUT OFF VALVE VALVE OR COCK GROUND SHALL BE ASTM B88 TYPE "L" HARD DRAWN COPPER TUBING WITH VERIFY DIMENSIONS WITH CABINET PROVIDER PRIOR TO PURCHASE. FS -1 FLOOR WROUGHT COPPER FITTINGS. 2 So 2 to "ZURN" ZN-1900-2-P 1/2 GRATE (NICKEL BRONZE) 12xl2 TOP SINK NUTS, AND WASHERS WHERE EXPOSED. ALL CONNEC71ONS SHALL BE MADE 26) WITH TRAP PRIMER CONNECTION. FD -1 FLOOR GAS-TIGHT AND WATER -TIGHT. USE OF PUTTY AND PLASTICS FOR 2 to 3 to "ZURN" ZN-415-58-P, CAST IRON BODY WMICKEL BRONZE ADJUSTABLE HEAD 1 DRAIN GASKETS WILL NOT BE PERMITTED. TRAP PRIMER CONNECTION, AND SEDIMENT BUCKET. "ZURN" Z-1350-15. ENCASED ANTI -SIPHON AUTOMATIC DRAINING COMPLETE WITH HOSE NON -FREEZE TYPE INTEGRAL BACKFLOW PREVENTER, ALL BRONZE INTERIOR PARTS HB -1 BIBB 3/4 ps NON -TURNING OPERATING ROD W/FREE-FLOATING COMPRESSION CLOSURE VALVE. 91WATER" NICKEL BRONZE BOX W/OPERATING KEY AND CAST ON BOX HOSE BIBB 3/4 "ZURN" Z1341 -P,34 -PC WALL FAUCET POLISHED CHROME WITH INTEGRAL HB -2 (UNDER LAV) VACUUM BREAKER "ZURN" Z-1315.-5 EXPOSED, NON -FREEZE WALL HYDRANT, ALL BRONZE INTERIOR HB -3 HOSE BIBB 3/4 to PARTS, NON -TURNING OPERATING ROD WITH FREE-FLOATING COMPRESSION CLOSURE VALVE. PROVIDE ADAPTER VACUUM BREAKER. SS -1 SERVICE 3/4 3/4 9$ 2 to 3 to "AMERICAN STANDARD" FLORWELL #7745, 811 28" x 28"xl3" ENAMELED CAST SINK IRON SERVICE -SINK WTH RIM GUARD, AMERICAN STANDARD #8344.112 FAUCET. STAINLESS SS SINGLE -COMPARTMENT SINK 24" SQUARE W/A BOWL DEPTH OF 187. AND 80" SS SS -2 STEEL 3/4 3/4 to 2 to 3#1 INTEGRAL DRAINBOARD. SINK AND DRAIN90ARD SHALL BE SVPPORTED.WTH SS LEGS SINK AND BASE ASSEMBLY. FAUCET: CHICAGO MODEL 200-A317 WITH HOSE AND SPRAY ASSEMBLY. CONDENSATE "ZURN" Z-127 CAST IRON CONDENSATE RECEPTOR W/ SOLID WA R CR -1 RECEPTOR 3 $0 DAM & DOME' BOTTOM STRAINER & P -TRAP. SECURE W/ STAINLESS STEEL SCREWS. SHOWER 2 2 to "'ZURN"' ZN-415-5B HINGED GRATE. STAINLESS STEEL SHD-1 DRAIN ADUSTABLE STRAINER, AND FLASHING COLLAR AUTOMA11C "PPP INC." MODEL P-2, BRASS CONSTRUCTION, PISTON OPERATED TP -1 TRAP 3/4 so PROVIDE STAINLESS STEEL ACCESS DOOR. PRIMER *"GUARDIAN"' G1643 HORIZONTALLY MOUNTED EMERGENCY SHOWER WITH STAY -OPEN ESHR-1 EMERGENCY 1 VALVE AND PULL ROD. PROVIDE AP280-220 INDOOR COMBINATION BLINKING LIGHT, SHOWER ALARM HORN AND ASSEMBLY. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. EXTRACTOR WASHER EXTRACTOR 3/4 to 3/4 to **ALLIANCE LAUNDRY SYSTEM" WASHER EXTRACTOR MODEL UW35 FLOOR MOUNTED. CLARIFIER - 3" 3" JENSEN PRECAST #JP750ECEE-CL; 750 GAH ON; 24" CAST IRON FRAME AND COVER CL -1 - WITH GASKET (GAS TIGHT). PROVIDE 24" SAMPLING BOX AIR COMPRESSOR SYMEE30L SYMBOL LOCATION MANUFACTURER I VOLTS 1 PHASE DESCRIPTION -NO* OF FIXTURES COMPRESSOR TOTAL FIXTURE UNITS OW MODEL 2475N5, 80 GALLON VERTICAL RECEIVER C-1 ROOM INGERSOLL-RAND 208 3 5 HPt 2 STAGE COMPRESSOR, 17.1 CFM, AT 125 PSIGY 3 6 RESIDUAL PRESSURE SERVICE SINK 175 PSIG MAX. PRESSURE, LOW LEVEL SWTCH, AIR 4 8 6 2 COOLED AFTER COOLER, AND ELECTRIC TANK 6 LAVATORY 4 1 DRAIN, MAGNETIC STARTER, START UP KIT. FIXTURE DATA & WATER CALCULATIONS DESCRIPTION HOT AND -COLD WATER SEWER .,NO. OF, .-FIXTURES F.U. PER FIXTURE -TOTAL FIXTURE UNITS -NO* OF FIXTURES F.U... PER FIXTURE TOTAL FIXTURE UNITS OW HW ;H WATER CLOSET (TANK) PRESSURE INSIDE BLDG. 2.5 7.5 7 PSI 3 6 RESIDUAL PRESSURE SERVICE SINK 2 4 8 6 2 3 6 LAVATORY 4 1 4 3 4 1 4 SHOWER STALL 3 2 6 4.5 3 2 6 EMERGENCY SHOWER 1 4 4 3 THE RECOMMENDATIONS OF MSS SP -69. LOW NOX HOSE BIBB 1 2.5 2.5 PROVIDE VALVES AT THE FOLLOWING LOCAT`IONS: 1 MINIMUM COVERAGE (ABOVE TOP OF PIPES) AS FOLLOWS: 2 HOSE BIBB CLOTHES WASHER 6 2 1 4 6 6 6 1 2 DISHWASHER 1 1.5 1.5 1.5 1 2 2 ICEMAKER 1 4 4 DOWN 1 2 2 KITCHEN SINK 1 4 4 3 1 2 2 FLOOR SINK 1 CONT 4 CONTINUE 1 2 2 COND. RECEPTOR 1 U JURISDICTION. IN CASE OF CONFLICT, THE MORE STRICT REGULATIONS 2 2 URINAL 1 4 1>3 2 2 EXTRACTOR 1 4 4 HANDMEELS OR OPERATORS ON TOP OR ARE HORIZONTAL AND SO THAT 1 4 4 TOTAL VALVES ARE EASILY ACCESSIBLE FOR OPERATION, SERVICE, REMOVAL 63.5 30 TRADES PRIOR TO START OF WORK. NECESSARY ADJUSTMENTS SHALL BE 52 WM SUPPLY-2ZINg-, TOTAL F. U. 63.5 STREET PRESSURE 114 PSI PER MARIA TORRES WTH WEST SAN BERNARDINO .3 WATER DISTRICT TEL NO. (909) 875-1804 ON APRIL OPER. WEIGHT 26 2005 12 LENGTH OF DOMESTIC WA7ER SYSTEM 458 FT PRV REQUIRED : -- YES PRESSURE INSIDE BLDG. 60 PSI WATER METER -------- 7 PSI STATIC HEIGHT (25 FEET): 10.75 PSI RESIDUAL PRESSURE 20 PSI TOTAL LOSSES :--- 38 PSI PIPE DIA. GPM r.U. 1/2#s .3 REMARKS OPER. WEIGHT 7 12 lot 20 30 1 1/4!9 34 47 1 1/2 to 32 92 2 9$ 55 135 GPM : 39 TOTAL: 39 AVAILABLE PIPING PRESS. LOSSES: ALLOWABLE FRICTION LOSS PER 100': 22 X 100 458 5 PSI VELOCITY NOT TO EXCEED 8 FT/SEC WATER HEATER SCHEDULE 22 1 .. I TAG MANUFACTURER LOCATION STORAGE CAPACITY LPG INPUT REMARKS OPER. WEIGHT S & MODEL NO. SEWER ABOVE GRADE (GAQ (BTUH) 9) les). W-1 NORITZ #N -069M SEE PLANS 0.3 194,000 DRAWN COPPER TUBING FACTORY INSULATED WITH WROUGHT COPPER TYPICAL PROVIDE ADDITIONAL COMPONENTS AS PER MANUFACTURER'S LOW NOX THE PLUMBING LAYOUT SHALL BE DONE AT NO EXTRA COST. CA FITTINGS. COMPRESSED AIR RECOMMENDATIONS FOR PROPER OPERATION OF THE FIXTURES. WH -2 NORITZ #N -084M -DV SEE PLANS 0.3 236,000 PROVIDE EACH PLUMBING FIXTUIRE(INCLUDING HOSE BIBS) WITH AN CD BUT NOT LIMITED TO THE GAS COMPANY, ELECTRIC COMPANY, LOW NOX CONDENSATE DRAIN TANK INDIVIDUAL STOP OR COMPRESSION VALVE OF POLISHED CHROME -PLATED TELEPHONE COMPANY, AND THE WATER DEPARTMENT, ABOUT THE EXTENT WH -3 NORITZ #N -084M -DV SEE PLANS 0.3 236oO00 OF PLUMBING WORK. ALL EXCAVATION WORK SHALL BE APPROVED BY ALL THE RECOMMENDATIONS OF MSS SP -69. LOW NOX I coo I 12) PROVIDE VALVES AT THE FOLLOWING LOCAT`IONS: ul APPROVED FOR USE IN CAU IA LOW NOX TYPE. PROVIDE EXPANSION TANK "FLEXCON" PH -5 2.1 GALLONS CAPACITY. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. Q FULLY AUTOMATIC CONTROLS WTH SAFETY SHUTOFF. POWER DIRECT VENT WATER HEATER. 4" PVC PIPE FOR VENTING AND AIR INTAKE. VERIFY SIZE WITH MANUFACTURER PRIOR TO START OF WORK. 0 FOR DETAILS SEE 1/P3.1 I PLUMBING MANDATORY MEASURES NOTES_ 1. ALL PLUMBING SYSTEM COMPONETS SHALL MEET OR EXCEED THE REQUIREMENTS OF C.B.C. (CALIFORNIA EDITION) , CMC, CPC, NEC, NFPA, ASTM, ANSI, AND ALL LOCAL AND STATE CODE REQUIREMENTS. 12. ALL PLUMBING EQUIPMENT LISTED IN (CCR) SECTION 2-111 MUST BE CERTIFIED BY THE MANUFACTURER TO MEET OR EXCEED SPECIFICATIONS OR EFFICIENCIES ADOPTED BY THE CEC. 3. ALL HEATERS FOR DOMESTIC HOT WATER MUST BE CERTIFIED BY THE MANUFACTURER TO MEET THE SPECIFICATIONS OR EFFICIENCIES AS ADOPTED BY THE CEC. IN ACCORDANCE WITH SECTION 10-113 OF THE CCR AND ENERGY EFFICIENCY STANDARDS RESIDENTIAL NON-RESIDENTIAL 4. ALL PIPING SHALL BE INSULATED IN ACCORDANCE TO SEC11ON 2-5312 OF CBC (CALIFORNIA EDITION) AND TABLE 10D OF CMC. 5. ALL INSULATION INSTALLED SHALL MEET THE FLAME SPREAD AND SMOKE DENSITY REQUIREMENTS OF SECTION 2-5314(B) OF CBC (CALIFORNIA EDITION). 6. FAUCETS SHALL BE 2.2 GPM MAXIMUM. 7. PROVIDE ULTRA LOW FLUSH TOILETS. 8. URINALS SHALL BE 1.0 GPF MAXIMUM. 9. SHOWER HEADS SHALL 2.5 G.P.M. MAXIMUM 10. ALL GAS APPLIANCES MUST HAVE PILOTLESS IGN111ON SYSTEM IN ACCORDANCE WTH SECTION 2-5314(C) OF CBC (CALIFORNIA EDITION). 11. ALL FIXTURES FOR THE HANDICAPPED SHALL BE INSTALLED AS PER THE LATEST REQUIREMENTS OF TITLE 24 AND ADA (AMERICANS WITH DISABILITIES ACT). 12. WATER HEATER SHALL COMPLY WITH SECTION 608.3 OF CPC, FOR THERM AL EXPANSION REQUIREMENTS. 13. CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL POTABLE WATER SUPPLIED APPLIANCES AND EQUIPMENT (OTHER THAN THOSE LISTED IN INFORMATION BULLETIN 103). 14. ALL FERROUS PIPING EXPOSED TO WEATHER SHALL BE GALVANIZED. 15. PLASTIC CONDENSATE PIPING MUST BE DVW RATED, OR 90 DEGREE TURNS ACCOMPLISHED WITH TWO 45 DEGREE FITTINGS. s SYMBOL OL F PL-UM.BING LEGEND PLUMBING GENERAL NOTESO APBREV. DESCRIPTION REMARKS S FLEXIBLE CONNECTOR, PIPING SEWER ABOVE GRADE 1) CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING 9) COLD WATER PIPES BELOW GROUND SHALL BE ASTM B88 TYPE -K" HARD 18) PROVIDE ALL FIXTURE COMPONENTS AS INDICATED ON DRAWINGS. GC UTILITY PIPES PRIOR TO START OF WORK. NECESSARY ADJUSTMENTS TO PROVIDE WITH APPROVED ACCESS PANEL DRAWN COPPER TUBING FACTORY INSULATED WITH WROUGHT COPPER TYPICAL PROVIDE ADDITIONAL COMPONENTS AS PER MANUFACTURER'S LPG THE PLUMBING LAYOUT SHALL BE DONE AT NO EXTRA COST. CA FITTINGS. COMPRESSED AIR RECOMMENDATIONS FOR PROPER OPERATION OF THE FIXTURES. 2) CONTRACTOR SHALL NOTIFY ALL LOCAL UTILITY COMPANIES INCLUDING 10) -PROVIDE DIELECTRIC FITTINGS FOR DISSIMILAR METALS IN CONTACT. 19) PROVIDE EACH PLUMBING FIXTUIRE(INCLUDING HOSE BIBS) WITH AN CD BUT NOT LIMITED TO THE GAS COMPANY, ELECTRIC COMPANY, 4.5 GALLON, SVED BASED ON CONDENSATE DRAIN TANK INDIVIDUAL STOP OR COMPRESSION VALVE OF POLISHED CHROME -PLATED TELEPHONE COMPANY, AND THE WATER DEPARTMENT, ABOUT THE EXTENT 11) PROVIDE HANGERS AND SUPPORTS FOR PIPING IN ACCORDANCE WITH Wco LOOSE KEY TYPE. W&L CLEAN-OUT OF PLUMBING WORK. ALL EXCAVATION WORK SHALL BE APPROVED BY ALL THE RECOMMENDATIONS OF MSS SP -69. 20) WHERE DEPTHS OR INVERTS ELEVATIONS ARE NOT INDICATED, PROVIDE coo UTILITY COMPANIES TO ASSURE PREVENTION OF INTERRUP11ON OF 12) PROVIDE VALVES AT THE FOLLOWING LOCAT`IONS: SOV MINIMUM COVERAGE (ABOVE TOP OF PIPES) AS FOLLOWS: SHUT-OFF VALVE EXISTING SERVICES PRIOR TO START OF WORK. Gv CLW GATE VALVE APPARTUS BAY POC Z-1464 POINT OF OONNECTION A� WATER MAIN SHUT-OFF VALVE IN VALVE BOX. A8V A) ANY PIPING UNDER SLAB (TOP OF PIPE TO UNDERSIDE OF SLAB): 3) ALL PLUMBING WORK SHALL MEET OR EXCEED THE REQUIREMENTS OF THE BEL 8 VALVE WITH HOSE CONNECTION ON DOWNSTREAM SIDE OF THE MAIN BELOW 18 INCHES. DN UNIFORM PLUMBING CODE, UNIFORM BUILDING CODE, UNIFORM DOWN SHUT-OFF VALVE. CLG B) CAST IRON AND COPPER PIPES IN OTHER LOCATIONS: 18 INCHES. CEILING MECHANICAL CODE, C.A.C. TITLE 24, AMERICANS WITH DISABILITIES FLR C) SHUT-OFF VALVE ON EACH SUPPLY TO EACH FIXTURE AND 21) EXCAVATE TO UNDISTURBED EARTH: CUT LEVEL AND FORM TRUE. REMOVE VTR ACT (A.D.A.), NATIONAL FIRE PROTECTION ASSOCIATION (N.F.P.A.), VENT THRU ROOF EQUIPMENT ITEM NOT PROVIDED VATH CONTROL STOP OR OTHER CONT DEBRIS, RUBBISH AND SOFT MATERIAL (SUCH AS MUD). WHERE ROCK IS CONTINUE THE LOCAL CITY AND COUNTY CODES, AND ALL OTHER CODES HAVING AP AUXILIARY SHUT-OFF VALVE. ACCESS PANEL ENCOUNTERED, UNDERCUT TRENCHES 6 -INCHES AND FILL WITH WELL U JURISDICTION. IN CASE OF CONFLICT, THE MORE STRICT REGULATIONS UNION HC TAMPED NEUTRAL SAND AND PEA GRAVEL TO PROPER PIPE ELEVATION. HANDICAPPED SHALL GOVERN. INSTALL SHUT-OFF VALVES SO THAT STEMS EITHER ARE VER11CAL WITH DURING EXCAVATION FREE OF STANDING WATER. UNDERCUT TRENCH 6- G HANDMEELS OR OPERATORS ON TOP OR ARE HORIZONTAL AND SO THAT INCHES AND INSTALL PIPING IN A 6 -INCH NEUTRAL SAND ENVELOPE. 4) ALL PLUMBING WORK SHALL BE COORDINATED WITH THE WORKS OF OTHER VALVES ARE EASILY ACCESSIBLE FOR OPERATION, SERVICE, REMOVAL RISER TRADES PRIOR TO START OF WORK. NECESSARY ADJUSTMENTS SHALL BE VENT THRU ROOF AND REPLACEMENT. 22) BACKFILL TO A POINT 12 -INCHES ABOVE TOP OF PIPING WITH EARTH CUBIC FEET PER HOUR MADE AT NO EXTRA COST. PRV PRESSURE REGULATING VALVE (EXCAVATED MATERIAL MAY BE USED) FREE OF CLAY, DEBRIS, GPM 13) PROVIDE SLEEVES FOR ALL PIPE AND TUBING PASSING THROUGH T RUBBISH, ROCKS, OR CLODS OVER 4 -INCHES IN THE GREATEST 5) FOR MINIMUM PIPE SIZE CONNECTIONS TO EACH PLUMBING FIXTURE SEE AS FLOORS, ROOFS, AND WALLS. PACK OAKUM INTO THE SPACE AROUND THE AQUASTAT DIMENSION. BACKFILL ABOVE 12 -INCHES FROM TOP OF PIPING MAY BE PLUMBING FIXTURE SCHEDULE. THESE VAWES ARE MINIMUM; LARGER PIPE OR TUBING. PROVIDE FLASHING FOR ALL PIPES EXTENDING WITH EXCAVATED MATERIAL. APPLY BACKFILL BY HAND IN 6 -INCH DEEP CONNEC71ONS MAY RESULT BASED ON THE DIFFERENT MANUFACTURER'S THROUGH THE ROOF. LAYERS THE FULL WIDTH OF THE TRENCH. MOISTEN EACH LAYER (DO RECOMMENDATIONS. NOT FLOOD OR PUDDLE), AND HAND TAMP TO A MINIMUM 90 PERCENT 14) ALL VENT TERMINATIONS AT ROOF SHALL BE AT I FAST 10 FEET AWAY COMPAC71ON BEFORE PROCEEDING WITH THE NEXT LAYER OF BACKFILL. 6) MANUFACTURER'S NAMES AND MODEL NUMBERS SHOWN FOR PLUMBING FROM OUTSIDE AIR INTAKES, OPERABLE WINDOWS, AND THE LIKE. FIXTURES AND EQUIPMENT ARE FOR REFERENCE ONLY. OTHER MANUFACTURERS WHICH CAN MEET THE DESIGN REQUIREMENTS OF THE 15) FILL CRACKS BETWEEN FIXTURES AND WALL/FLOORS WITH SILICONE 23) DO NOT EXCAVATE UNDER FOUNDATIONS OR FOOTINGS EXCEPT IN MANNER PLUMBING SYSTEM MAY BE SUBSTITUTED UPON APPROVAL FROM THE RUBBER SEALANT. PERMITTED BY THE ARCHITECT. DO NOT BACKFILL UNTIL INSTALLED ARCHITECT AND THE OWNER. PIPING HAS BEEN SUCCESSFULLY TESTED. 16) LOCATE, SIZE, AND INSTALL WATER HAMMER ARRESTERS IN ACCORDANCE "BLACK" 7) SEWER AND VENT PIPES SHALL BE AS7M A74 SERVICE WEIGHT CAST WITH PLUMBING AND DRAINAGE INSTITUTE STANDARD NO. WH -201. 24) ALL GAS PIPING ABOVE GROUND SHALL BE STEEL. ALL FIT`TINGS IRON. VENT PIPES ABOVE GROUND MAY BE STANDARD WEIGHT SHALL BE AS PER UPC. GALVANIZED STEEL. 17) INSTALL FIXTURES IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND ALL APPUCABLE CODES. SECURE FLOOR OUTLET 25) ALL GAS CONNECTIONS TO GAS APPLICANCES AND EQUIPMENT SHALL BE MADE 8) HOT AND COLD WATER PIPES, AND CONDENSATE DRAIN PIPES ABOVE OF FLOOR -MOUNTED FIXTURES TO DRAINAGE CONNECTIONS AND FLOOR IN USING METAL FLEXIBLE CONNECTOR, AND SHUT OFF VALVE VALVE OR COCK GROUND SHALL BE ASTM B88 TYPE "L" HARD DRAWN COPPER TUBING WITH A RIGID MANNER. RIGIDLY SUPPORT WALL -HUNG FIXTURES BY MEANS OF APPROVED FOR USE NTH GAS. WROUGHT COPPER FITTINGS. METAL SUPPORTING MEMBERS. USE CHROMIUM -PLATED BRASS BOLTS, NUTS, AND WASHERS WHERE EXPOSED. ALL CONNEC71ONS SHALL BE MADE 26) ALL GAS PIPING BELOW GROUND SHALL BE APPROVED "PE" TYPE. ALL GAS-TIGHT AND WATER -TIGHT. USE OF PUTTY AND PLASTICS FOR FITTINGS SHALL BE AS PER UPC. GASKETS WILL NOT BE PERMITTED. Q FULLY AUTOMATIC CONTROLS WTH SAFETY SHUTOFF. POWER DIRECT VENT WATER HEATER. 4" PVC PIPE FOR VENTING AND AIR INTAKE. VERIFY SIZE WITH MANUFACTURER PRIOR TO START OF WORK. 0 FOR DETAILS SEE 1/P3.1 I PLUMBING MANDATORY MEASURES NOTES_ 1. ALL PLUMBING SYSTEM COMPONETS SHALL MEET OR EXCEED THE REQUIREMENTS OF C.B.C. (CALIFORNIA EDITION) , CMC, CPC, NEC, NFPA, ASTM, ANSI, AND ALL LOCAL AND STATE CODE REQUIREMENTS. 12. ALL PLUMBING EQUIPMENT LISTED IN (CCR) SECTION 2-111 MUST BE CERTIFIED BY THE MANUFACTURER TO MEET OR EXCEED SPECIFICATIONS OR EFFICIENCIES ADOPTED BY THE CEC. 3. ALL HEATERS FOR DOMESTIC HOT WATER MUST BE CERTIFIED BY THE MANUFACTURER TO MEET THE SPECIFICATIONS OR EFFICIENCIES AS ADOPTED BY THE CEC. IN ACCORDANCE WITH SECTION 10-113 OF THE CCR AND ENERGY EFFICIENCY STANDARDS RESIDENTIAL NON-RESIDENTIAL 4. ALL PIPING SHALL BE INSULATED IN ACCORDANCE TO SEC11ON 2-5312 OF CBC (CALIFORNIA EDITION) AND TABLE 10D OF CMC. 5. ALL INSULATION INSTALLED SHALL MEET THE FLAME SPREAD AND SMOKE DENSITY REQUIREMENTS OF SECTION 2-5314(B) OF CBC (CALIFORNIA EDITION). 6. FAUCETS SHALL BE 2.2 GPM MAXIMUM. 7. PROVIDE ULTRA LOW FLUSH TOILETS. 8. URINALS SHALL BE 1.0 GPF MAXIMUM. 9. SHOWER HEADS SHALL 2.5 G.P.M. MAXIMUM 10. ALL GAS APPLIANCES MUST HAVE PILOTLESS IGN111ON SYSTEM IN ACCORDANCE WTH SECTION 2-5314(C) OF CBC (CALIFORNIA EDITION). 11. ALL FIXTURES FOR THE HANDICAPPED SHALL BE INSTALLED AS PER THE LATEST REQUIREMENTS OF TITLE 24 AND ADA (AMERICANS WITH DISABILITIES ACT). 12. WATER HEATER SHALL COMPLY WITH SECTION 608.3 OF CPC, FOR THERM AL EXPANSION REQUIREMENTS. 13. CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL POTABLE WATER SUPPLIED APPLIANCES AND EQUIPMENT (OTHER THAN THOSE LISTED IN INFORMATION BULLETIN 103). 14. ALL FERROUS PIPING EXPOSED TO WEATHER SHALL BE GALVANIZED. 15. PLASTIC CONDENSATE PIPING MUST BE DVW RATED, OR 90 DEGREE TURNS ACCOMPLISHED WITH TWO 45 DEGREE FITTINGS. EQUIPMENT SCHEDULE s SYMBOL OL F PL-UM.BING LEGEND SYMBOL APBREV. DESCRIPTION REMARKS S FLEXIBLE CONNECTOR, PIPING SEWER ABOVE GRADE Cv CHECK VALVE I .''..:.SEWER BELOW GRADE BALL VALVE V GC SANITARY VENT PROVIDE WITH APPROVED ACCESS PANEL CW TYPICAL COLD WATER LINE LPG Hw CA HOT WATER LINE COMPRESSED AIR HWR IE HOT WATER RETURN LINE G G EXPANSION GAS LINE CD CD 4.5 GALLON, SVED BASED ON CONDENSATE DRAIN TANK FC0 FLOOR CLEAN-OUT MANUFACTURERS REQUIRMENTS. PRV Wco W&L CLEAN-OUT REGULATOR 1-1191 coo 223-2" GRADE CLEAN-OUT SOV SHUT-OFF VALVE >Q Gv CLW GATE VALVE APPARTUS BAY POC Z-1464 POINT OF OONNECTION A8V ABOVE BEL BELOW DN DOWN CLG CEILING FLR FLOOR VTR VENT THRU ROOF CONT CONTINUE AP ACCESS PANEL U UNION HC HANDICAPPED REDUCER IN PIPE G GAS (NATURAL) P T PRESSURE & TEMPERATURE RELIEF VALVE RISER VENT THRU ROOF CFH CUBIC FEET PER HOUR PRV PRESSURE REGULATING VALVE GPM GALLONS PER MINUTE T THERMOMETER AS AQUASTAT EQUIPMENT SCHEDULE s SYMBOL OL F PIPE DOM LOCATION MANUF. PIPE UP REMARKS FC FLEXIBLE CONNECTOR, PIPING Cv CHECK VALVE I BV BALL VALVE VARIOUS GC GAS COCK PROVIDE WITH APPROVED ACCESS PANEL TYP. TYPICAL LPG LPG LIQUIFIED PETROLEUM GAS CA CA COMPRESSED AIR WATER IE INVERT ELEVATION EQUIPMENT SCHEDULE s SYMBOL OL F EQUIPMENT LOCATION MANUF. MODEL REMARKS WATER WH A HAMMER VARIOUS MIFAB HAMMERGUARD PROVIDE WITH APPROVED ACCESS PANEL ARRESTOR (ABV CLG) IF LOCATED IN HARDLID CEILING AREA ET THERMAL WATER EXPANSION HEATER FLEXCON YM -18 4.5 GALLON, SVED BASED ON TANK ROOM MANUFACTURERS REQUIRMENTS. PRV PRESSURE REGULATOR YARDBOX WILKINS 223-2" LOCATED IN YARDBOX WITH BLDG VALVE SHUT-OFF VALVE CLW WATER SUPPLY APPARTUS BAY ZURN Z-1464 WALL MOUNTED NEAR CLOTHES WASHER CONTROL BOX CONSULTANT: T�SQUARED PROFFMIONAL ENGINEM. fNC. 1340 SPECIALTY DRIVE SUITE E VISTA, CA 92081 TEL: (760) 560-0100 FAX: (760) 560-0101 E -Mail odmin@tsqeng.com www.tsqeng.com #04091 06-07-06 ISSUE INFORMATION: DATE: INFORMA-nON: &-Y-%9 11 %.Ps I Z!� MAY 2006 kEVISION 6.wl 1% VLIN "ElUK F AMAY 18,20M 1 R \A, -;I )q SHEET INFORMATION: PROJECT NO.: #_ SCALE: AS NOTED - DATE: DECELSER Z 2005 PLOT DATE: DRA\MNG NAME: SEAL: