Loading...
HomeMy WebLinkAbout3961-1GENERAL SEWER NOTES: 1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVE- LOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DE)ACES AT ALL TIMES. 7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SKALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEASION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCT10N SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE S�ALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES& 18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN - AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21 A GEOTECHNiCAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P.. 26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT-OF-WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL. 32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT 36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING 37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. REV. I REVISION DESCRIPTION v ­vvvvvvvvvv AAAAAA PEMN 16652 (TR 17596 I Ij CD SOILS ENGINEER: GEO-ETKA, INC. 739 N. MAIN STREET ORANGE, CA 92868 (714) 771-6911 (714) 771-1278 DEVELOPER: LEBANOFF DEVELOPMENT GROUP 2595 WEST POST ROAD, SUITE A LAS VEGAS, NEVADA 87119 (702) 336-0636 (702) 914-0312 OWNER: FONTANA CROSSINGS L.L.0 45325 SAGE LANE, NO. 6 PALM DESERT, CA. 92260 (714) 742-5535 CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA PACIFIC BELL CO. ATTN: BRIAN WREN ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E.CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 THE GAS COMPANY COMCAST (CABLE TV) ATTN. GREG GASPAR ATTN: JACK HAYES 16231 VALLEY BLVD. 1205 DUPONT AVENUE FONTANA, CA. 92335 ONTARIO, CA. 91761 (909) 428-8411 (909) 390-4736 (800) 427-2000 0255-031 —15 SO. CALIFORNIA EDISON COMPANY GENERAL TELEPHONE COMPANY 7951 REDWOOD AVENUE ATTN: STEVE HOCK FONTANA, CA. 92335 1400 E. PHILLIPS BLVD. (909) 820-5598 UNDERGROUND ONTARIO, CA. 91766 (909) (909) 875-5100 — TRANSMISSIONS 800) 422-4133 (213) 637-1233 PIPELINES LF (909) 357-6233 DISTRIBUTION FONTANA WATER COMPANY (800) 422-4133 ATTN: MICHAEL J. McGRAW TO 90%. 8440 NUEVO AVENUE CRAWFORD CANYON MUTUAL WATER CO. FONTANA, CA 92335 ATTN: BILL VANDERKIEFT, JR. (909) 822-2201 (619) 868-6040 FAX: (909) 823-5045 UNDERGROUND SERVICE ALERT 9 (800) 227-2600 uj No. 65195 rl cy- — ;u DATE ENGR. CITY DATE vjn%."%R %R THE a4SIS OF BE4RINGS FOR THIS PROVECT IS THE CENTERLINE OF SLOVER AVENUE BEING N89'53'28"E PER A4.8. 1481109-110, RECORDS OF S4N BERNARDINO COUNTY. 8MCH MMK: # 2a377 AT THE INTERSECTION OF SLOVER AVENUE & SIERRA AVENUE BEING A FOUND 1" LP. STAA4PED L.S. 5749. TION: 1089.40 1 0255-031-18 1 1 0255-191-191 1 1 1 MH NO. 241, 0255-1-9-1--201 0255-191-211 0255-031 -17 MH NO.1 0255-191-181 TRACT 116651 1 0255-191-17 ALISO DR. INDEX MAP SCALE: 1 "= 120' PRIVATE ENGINEER'S NOTICE TO CONTRACTORS TABLE: 200-1.2 [A] SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1/2- 3/4- 100 112- 90-100 5/8' 20-60 NO. 4 0-15 NO. 9 0-5 ASTM C 131 8 TEST GRADING SLOVER AVE PROACT LOCATION uj uj —:z UJI uj uj :z LLj Cy— Z3 st 13— V) 6" MIN. VARIES 6 MIN. 10" MAX. I I 1 10" MAX. SANTA ANA AVE ASPHALTIC CONCRETE SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; JQRUPA AVE TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT Th), I-If BEGIN CURVE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE z DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABIUTY AND RESPON- PM 16652 3" MAX. SIZE T - PARCEL 2 VIC INITY MAP NATIVE SOIL BACK SIDEWALK SUBGRADE NOT TO SCALE COMPACTED 95%o. 0255-031 —15 THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; Ell MH NO. 3 1 " MAX. SIZE 0255-031-20 IN CONNECT10N WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING Pm 16' C 11 M Ej, SELECTED NATIVE INSTALL 8" EXTRA STRENGTH V.C.P. SEWER. 6" MAX. SIZE LF BEDDING COMPACTED END CURVE NATIVE SOIL TO 90%. SEAL COMPACTED 9070. mi 1 0255-031-18 1 1 0255-191-191 1 1 1 MH NO. 241, 0255-1-9-1--201 0255-191-211 0255-031 -17 MH NO.1 0255-191-181 TRACT 116651 1 0255-191-17 ALISO DR. INDEX MAP SCALE: 1 "= 120' PRIVATE ENGINEER'S NOTICE TO CONTRACTORS TABLE: 200-1.2 [A] SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1/2- 3/4- 100 112- 90-100 5/8' 20-60 NO. 4 0-15 NO. 9 0-5 ASTM C 131 8 TEST GRADING SLOVER AVE PROACT LOCATION uj uj —:z UJI uj uj :z LLj Cy— Z3 st 13— V) 6" MIN. VARIES 6 MIN. 10" MAX. I I 1 10" MAX. SANTA ANA AVE i TYPICAL BEDDING DETAIL FOR 8" VCP LESS THAN 10"DEEP TABLE: 200-1.2 [A] SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1,12- 3/4- 100 1112- 90-100 20-60 NO. 4 0-15 NO. 8 0-5 ASTM C 131 8 TEST GRADING THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES ASPHALTIC CONCRETE SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; JQRUPA AVE TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT Th), I-If BEGIN CURVE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE z DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABIUTY AND RESPON- 3" MAX. SIZE T - SHOWN ON THESE DRAWINGS. VIC INITY MAP NATIVE SOIL BACK SIDEWALK SUBGRADE NOT TO SCALE COMPACTED 95%o. THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; CATCH BASIN AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER 1 " MAX. SIZE IN CONNECT10N WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING CENTERLINE SELECTED NATIVE INSTALL 8" EXTRA STRENGTH V.C.P. SEWER. 6" MAX. SIZE LF BEDDING COMPACTED END CURVE NATIVE SOIL TO 90%. SEAL COMPACTED 9070. EDGE PAVEMENT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL E jes 4 EA SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, 9 8 V. C. P. uj No. 65195 rl cy- — ;u THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO to F.L. F.S. Z Ll Ld civl\- 10 EA/315 c E0, FINISH SURFACE Ull i TYPICAL BEDDING DETAIL FOR 8" VCP LESS THAN 10"DEEP TABLE: 200-1.2 [A] SIEVE SIZE PERCENTAGE PASSING SIEVES 1 1,12- 3/4- 100 1112- 90-100 20-60 NO. 4 0-15 NO. 8 0-5 ASTM C 131 8 TEST GRADING THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES ASPHALTIC CONCRETE SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE BEGIN CURVE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABIUTY AND RESPON- SIBIUTY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT BEG. VERTICAL CURVE SHOWN ON THESE DRAWINGS. QUANTITIES THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSI- BACK SIDEWALK BILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; CATCH BASIN AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECT10N WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING CENTERLINE FOR'LIABIUTY., ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE INSTALL 8" EXTRA STRENGTH V.C.P. SEWER. ENGINEER. LF CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT END CURVE ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. SEAL SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT EDGE PAVEMENT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL E jes 4 EA SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, 9 uj No. 65195 rl cy- — ;u THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO to F.L. F.S. 0 Expi 9-30-07 BRING THEM INTO CONFORMANCE WITH CONDITIONS AND civl\- 10 EA/315 c STANDARDS IN EFFECT. FINISH SURFACE N.T.S. 6" MIN. VARIES 6" MIN. �10 ..." . -20 3" MAX. SIZE— NATIVE SOIL COMPACTED 95%. 6 is MAX. SIZE — NATIVE SOIL COMPACTED 90%. 8 " V. C. P. 0�0- �jml IN 1 " MAX. SIZE SELECTED NATIVE BEDDING COMPACTED TO 90%. 1/2" CRUSHED STONE BEDDING PER STD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A]. TYPICAL BEDDING DETAIL FOR 8" VCP 10'OR DEEPER N.T.S. LEGEND I A.U. ASPHALTIC CONCRETE B.C. BEGIN CURVE B.V.C. BEG. VERTICAL CURVE CONSTRUCTION NOTES QUANTITIES B.W. BACK SIDEWALK C.B. CATCH BASIN C.L. CENTERLINE INSTALL 8" EXTRA STRENGTH V.C.P. SEWER. 1,236 LF E.C. END CURVE E.P. EDGE PAVEMENT CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF 4 EA E.G. E.V.C. EDGE GRADE END VERTICAL CURVE FONTANA STD. DWG. NO. 112 (10=48"). F.L. F.S. FLOW LINE 3 INSTALL 4" EXTRA STRENGTH V.C.P. SEWER LATERAL 10 EA/315 LF FINISH SURFACE G.B. GRADE BREAK PER CITY OF FONTANA STD. DWG. NO. 125. H.P. INV. HIGH POINT INVERT INSTALL 6" EXTRA STRENGTH V.C.P. SEWER LATERAL 3 EA/95 LF L.E. LANDSCAPE EASEMENT PER CITY OF FONTANA STD. DWG. NO. 125. O.C. P.C.C. ON CENTER PORTLAND CEMENT CONCRETE TRENCHING PER CITY OF FONTANA STD. DWG. NO. 1031. 1, 187 LF (R) R/W RIDGE LINE RIGHT OF WAY INSTALL 8" SEWER PLUG. 1 EA TAN. TANGENT T.C. TOP OFCURB DEVELOPMENT & ENGINEERING, INC. T APLANNING AND CIVIL ENGINEERING t 1181 CALIFORNIA AVENUE, SUITE 101B CORONA, CA 92881 (951) 371-0264 PHONE (951) 371-1365 FAX a 2 - goo - los:� MANUEL DE JESUS OONZALCS, RCE 65195 (EXP. 9-30-07) DATE CITY OF FONTANA, CALIFORNIA SEWER IMPROVEMENT PLANS DRAM BY: P.M. 16652 JR 17596) Scmk MJG AS SHOWN_ DEMM BY: MJG JLINIP�R E SEWER DATE - DEC 2005 QiECKED BY: B Y.- DRAWNG NO.: qSA MJG 72i .-a I— - 7 -,P6 3961 CITY ENGINKER R -X -T751152 -6—ATE 2 1 -­ A CN LO co co z 0 - �i W z w w U)