HomeMy WebLinkAbout3791-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST 1N THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF 774E CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFlC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC
EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE (5) FEET SHALL ALSO SE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
SAFETY.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY 1MTHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE IN THE FIELD, THE
TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION
TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS N017CE PRIOR TO WORK
AROUND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES. CONTRACTOR
SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER
REQUIREMENTS.
13. STAT70NING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT 774E WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WALL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES.
A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CLOSURE AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXIS17NG CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL
CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM 774E DOWNSTREAM MANHOLE,
SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTOEO OF BELL AND SPIGOT OR BAND SEAL TYPE
WTRIFIE0 CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS
OF THE ASTM DESIGNATION C700 FOR V.C.P.
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF
THE CITY ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO
ALLOW FOR MINOR DEFLECT70NS IN ALIGNMENT
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXIS77NG FACIUTIES, AND VERIFY
ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING
FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW
THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY,
THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S' IN THE FACE OF THE CURB AT THE LOCATION OF
THE SEWER LATERAL.
32. 1FEXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS,
THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
S TREE TS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED
GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
3Z UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC
ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD,
WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
DlGdLtRT
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG YOU DIG
TOLL FREE 1-800-227-260:0
A PUBLIC SERVICE BY
UNDERGROUND SERVICE ALERT
NMEwlE'ploMP'IVIERM' A
B P R
PA L MAP N
ABBREVIATIONS
VC .......
VERTICAL CURVE
TP .......
TOP OF PAVEMENT
TC .......
TOP OF CURB
EL .......
ELEVA TION
FL .......
FLOWIJNE
FG .......
FINISH GRADE
FS .......
FINISH SURFACE
CF .......
CURB FACE
GB .......
GRADE BREAK
HP .......
HIGH POINT
INV .......
INVERT ELEVATION
TG .......
TOP OF GRA TE
CS .......
CATCH BASIN
RD .......
ROOF DRAIN
LO .......
LOCAL DEPRESSION
EP........
EDGE OF PAVEMENT
COTG ....
CLEANOUT TOP OF GRATE
SMH ......
SEWER MANHOLE
R .........
RIDGE LINE
P.I.P.....
PROTECT IN PLACE
CL .......
CENTERLINE
OWY......
DRIVEWAY
WS EL ...
WATER SURFACE ELEVATION
1000
PROPOSED CONTOUR
s3s
EXISTING CONTOUR
UTTUTY PROVIDERS
SEWER
CABLE - TV
CITY OF FONTANA
ADELPHIA COMUUN/CATIONS
8353 SIERRA AVENUE
5944 SYCAMORE COURT
FONTANA, CA 92335
CHINO, CA 91710
(909) 350-6731
(909) 591-9571
ELECTRIC
TELEPHONE
RON CARDENAZ
SBC PACIFIC
SBC PACIFIC BELL
EL
SOUTHERN CALIFORNIA EDISON
55
(909) 357-6240
ADJUST MANHOLE RIM TO GRADE AFTER FINAL PAVING IS INSTALLED
GAS
I
SOUTHERN CALIFORNIA GAS CO.
PER CITY OF FONTANA STD. 109............................................................................................
SAN DIMAS CA 91773
EA
(800)427-2000
PROVIDE MANHOLE SHAFT SAFETY LEDGE PER APWA STD. 330--1 (SEE DETAIL HERE ON) ......................
WATER
EA
VEST SAN BFRNARDINO COUNTY WATER DISTRICT
855 WEST BASELINE, P.O. BOX 920
RIALTO, CALIFORNIA 92377-0920
EA
(909) 875-1804
CONSTRUCT 5' 0 MANHOLE PER CITY OF FONTANA STD. 112 (MANHOLE DEPTH>15' OR
UNAUTHORIZED CHANGES AND USES
CONSTRUCTION NOTES
THE QUANT177ES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS
SHALL PREPARE THEIR OWN QUAN TI TIES AND 610 A COMPLETE JOB.
s3
INSTALL 8" "EXTRA STRENGTH" VCP SEWER LINE (BEDDING PER DETAIL ON SHEET 1) ..........................
1738
LF
s4
INSTALL 10" "EXTRA STRENGTH" VCP SEWER LINE (BEDDING PER DETAIL ON SHEET 1) .........................
1288
LF
G
INSTALL 12" "EXTRA STRENGTH" VCP SEWER LINE (BEDDING PER DETAIL ON SHEET 1) .........................4615
vrr: ,ear
LF
O
INSTALL 15" "EXTRA STRENGTH" VCP SEWER LINE (BEDDING PER DETAIL ON SHEET 1) ........................
1638
LF
s1t
ADJUST MANHOLE RIM TO GRADE AFTER FINAL PAVING IS INSTALLED
MH131 I llqt
:r
I
17 I I
PER CITY OF FONTANA STD. 109............................................................................................
34
EA
9
PROVIDE MANHOLE SHAFT SAFETY LEDGE PER APWA STD. 330--1 (SEE DETAIL HERE ON) ......................
17
EA
s15
CONSTRUCT 4' 0 MANHOLE PER CITY OF FONTANA STD. 112 .........................................................
10
EA
sJs
CONSTRUCT 5' 0 MANHOLE PER CITY OF FONTANA STD. 112 (MANHOLE DEPTH>15' OR
2
0 BELL
SEWER PIPE DIAMETER>15-)........................................................................... . ......................
24
EA
S22
SAWCUT, REMOVE AND REPLACE EX. PAVING IN KIND PER CITY OF
4-1574 (SIS, 01AGONAL3 j P ACE DIAGONAL
(4,11) r
DETAIL "L "A' L= 1.3 nk (4,�P B BOTTOM
ROTATED 93• SECTION Q-9
FONTANA STD. 131........................................................•-----.-.-.---.................................------..
250
SF
s3s
INSTALL 8" x 6' VCP WYE.....................................................................................................
6
EA
sa4
INSTALL 6" VCP 45 DEGREE ELL ........................................... . . ...............................................
22
EA
sssINSTALL
6" VCP PLUG...................................................................................... . . . . . ...............
22
EA
ss4
MODIFY EXISTING SEWER MANHOLE FOR PROPOSED CONNECTION......................................................
i
EA
S65
CONNECT TO EXISTING MANHOLE ............ .................................................................................
1
EA
9
INSTALL 15"X6" VCP WYE.......................................................................................................
8
EA
sT1REMOVE
EXISTING SEWER UNE.................................................•-•-----...........---...............------......
ST3
PROTECT EXISTING UTILITY IN PLACE (TYPE AS SPECIFIEO).............................................................
I
MH#4
S81
CONSTRUCT SEWER ENCASEMENT PER DETAIL ON SHEET 1.............................................................
S86
MODIFY EXISTING SEWER LINE FOR PROPOSED CONNECTION.............................................................
2
EA
O
INSTALL 6" SEWER LATERAL...................................................................................................1075
LF
S89INSTALL
12"X6" VCP WYE ...........................................................................................•-----.....
5
EA
s9O
INSTALL 10" x 6" VCP WYE...................................................................................................
3
EA
CAUTION: 774E ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR.
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF 774ESE PLANS
NOTES.
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE 774E DEVELOPER FROM RESPONSIBILITY FOR THE
CORRECTION OF V?RORS AND OMISSIONS DISCOVERED DURING CONST RUCWX UPON REQUEST OF
714E CITY INSPECTOVR, 774E REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO 774E
CITY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES 714AT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING 714E COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY• THAT THIS REQUIREMENT
SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WI714
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM 774E SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND U77UTY PIPES OR STRUC7URES SHOWN ON
774ESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTIU77ES EXCEPT AS SHOWN ON THESE PLANS THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT 774E UTILITIES
SHOWN AND ANY OTHER ONES OR STRUCTURES NOT SHOWN ON 714ESE PLANS
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO
MESE PLANS SHALL CONDUCT TUR OPERATIONS SO 774AT ALL EMPLOYEES ARE PROVIDED A SAFE
PLACE TO WORK AND 714E PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS
SHALL COMPLY M714 THE 'OCCUPATIONAL SAFETY AND HEAL 714 REGULATIONS" OF THE U.S.
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
RELATIONS' 'CONSTRUCTION SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR 774E CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS"
OF THE U.S. DEPARTMENT OF LABOR OR IM774 THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS'.
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; 174AT 774IS REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY AND HOLD THE OWER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION W! 714 THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF 774E OWNER OR
ENGINEER.
BASIS OF BEARING
THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA STATE PLANE
COORDINATE SYSTEM ZONE 5. BASED LOCALLY ON THE COUNTY OF SAN
BERNARDINO GPS STATION 20377 FILED IN BOOK 004015 PAGE 001548 ON
FILE IN THE OFFICE OF THE COUNTY SURVEYOR OF SAID COUNTY AND GPS
STATION 20384 FILED IN BOOK 004015 PAGE 001555 ON FILE IN THE OFFICE
OF SAID COUNTY SURVEYOR.
BENCHMARK ELEV. 1077.40
LOCATION:
CHISELED BOX IN EASTERLY TOP OF CURB
TAMARIND AVE., 60' SOUTH OF TAMARIND CT.,
500' SOUTH OF SLOVER AVENUE.
NO.
REVISION DESCRIPTION
[Ill i.f[1`LL�1
SECTION A -A
(-- PRECAST
FLOOR SLAB
0
^'-50 mu or i54
62`16'1
VERTICAL
SECTION
- ....
MANHOL5 SHAFT SAFETY LEDGE
�,OP
s�naac>Y eo�ee rrra
6
3 ,I
SLAB
I
40 rem U 1/2'1 GRpc1T 51HOLES
vrr: ,ear
_00NALl
FOR FLOOR SLAa LSnm(24`1
Ubt"M STANDARD SREGIFKAIVOt4 MR PUBLIC WORKS COASTRUGTI{?li
NO. 4
0-15
NO. 5
MH
k4-
MH131 I llqt
:r
I
17 I I
AOUT
13
'
2-14 BARS TVP
!
I
2
0 BELL
MH
ma 13'-4• LON
MH#7
H#30 - I I f - R - U)
I I
I
4-1574 (SIS, 01AGONAL3 j P ACE DIAGONAL
(4,11) r
DETAIL "L "A' L= 1.3 nk (4,�P B BOTTOM
ROTATED 93• SECTION Q-9
REIrIF'ORCEW01 DETAILS
FOR FLOOR "o ROOF suss
AMERICAN PUBLIC WORK3 ASSOCIATION - SOUTHERN CALIFORMA CHAPTER
- -
FN4k,kGAr-W 9R I
nA, ,Rn=�
- ....
MANHOL5 SHAFT SAFETY LEDGE
$TANWDAAW
T
s�naac>Y eo�ee rrra
I
3 ,I
tp
I
112m
vrr: ,ear
SrteET t OF R
Ubt"M STANDARD SREGIFKAIVOt4 MR PUBLIC WORKS COASTRUGTI{?li
DATE ENGR. I CITY I DATE
SHOULD CONSTRUCTION OF THE
REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED
FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE
WITH STANDARDS IN EFFECT.
I -
I
�I 1 2 3
4 I
I` 5
LINE
SEET11
NOTES
I. MANHOLE SHAFT SAFETY LEDGE WILL BE NOTED 09 THE, PROJECT
DRAWINGS WHEN REOUIR€O. IT 13 TO OE CON3TRUCT1_D WHEN DEPTH
OF MANHOLE TO INVERT 13 GREATER THAN 6 rrd20"1 AND MA14HOLE
SHAFT 13 GREATER THAN:3
2. A SAFETY LEDGE SHALL NOT BE USED IF A PRESSURE MANHOLE IS
REOVIRED.
3. STEPS SHALL COWORM TO STANOARO PLAN 633 OR $36 ANO SHALL
BE ANCHORED 104 mm f4.1 IN THE WALE. OF THE STRUCTURE. STEPS
SHALL BE PLACED TO MATCH THE SPACING OF THE MANHOLE SHAFT,
4. REINFORCEMENT SHALL BE PER ASTM A 666 GRADE 300 (ASTM A 615,
GRADE 40) AND SHALL TERMINATE 50 mm (21) CLEAR OF CONCRETE
SURFACE UNLESS OTHERWISE SHOWN.
S. GROUT HOLES, PIPE AND FITTINGS SMALL BE PROVIOCO IN THE FLUOR
SLAB. PRESSURE GROUTING SHALL BE USED TO FILL VOIDS AND TO
SECURE UNIFORM BEARING. T14E GROUT SHALL BE NEAT CEMENT
GROUT AND muTma; PRESSURES SHALL BE AS DETERMINED IN T'He
FIELD BY THE ENGINEER.
6. PIPE RAIL SHALL BE FABRICATED OF 32 mm V 1/4•) STANDARD GALVANIZED
PIPE COMPOSED OF TWO SECTIONS 2.25 m (P-44 8 450 mm (19.1 IN
LENGTH JOINED BY A GALVANIZED COUPLING. THE COUPLING SHALT. BE
THREADED A MINIMUM OF 50 mm (21 ON EACH PIPE LENGTH,
7. ROOF AND FLOOR SLABS SHALE. BE PRECAST AND KEYED FOR
REINFORCED CONCRETE PIPE SECTIONS AS SHO>r K ALL JOINTS SHALL
BE FILLED WITH CLASS C MORTAR AND NEATLY POINTED OR WIPED ON
THE INSIDE.
S. 1800 mm (72') RCP SHALL BE PROVIDED WITH TWO CIRCULAR CAGES OF
REINFORCEMENT,
9: QIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE
NOT EXACT C EQUAL VALUES. If METRIC VALUES ARE USED, ALL VALUES
USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING
BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES.
IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALE.
BE ENGLISH UNITS.
THE FOLLOWING STANDARD PLAN IS INCORPORATED HEREIN=
324 MANHOLE SHAFT - WITH ECCENTRIC REDUCER
326 MANHOLE SHAFT 400mra 136•11 WITHOUT R€DUrER
635 STEEL. STEP
636 POLYPROPYLE14C PLASTIC STEP
7
0
10 »
SHE T 8
2
6
W
u
SLOVER AVENUE SHEET 5
SHEET NO.
-
1
TITLE SHEET
I
SEWER IMPROVEMENT PLANS & PROFILE
MH 10
I
112m
90-100
318"
20-60
NO. 4
0-15
NO. 5
MH
ASTM C 131
TEST GRADING
MH131 I llqt
:r
I
17 I I
13
'
2-14 BARS TVP
581
I
2
0 BELL
MH
DETAILBEDDING ON 5#ET 1
MH#7
H#30 - I I f - R - U)
I I
I
fI
i
MH#29 �- PROP.-
14
_
I I
I I LINE A
I
MH#6
MH 28 I I
I
- - - I
W
°° I
MH#5
MH27
LINE D 15 (j)
I
I
MH#4
Q�
-N
MH#26 771<41\
; .i
MH#318
MH#25
16 W
LLI
SHEET 7IEET 6
MH 2 19
MH#1
SANTAANA AVENUE -
_ _ _
2
(n 1 U-)
SHEET INDEX MAP
NOT TO SCALE
SHEET INDEX
SHEET NO.
DESCRIPTION
1
TITLE SHEET
2-11
SEWER IMPROVEMENT PLANS & PROFILE
AMERICAN PUBLIC WORKS ASSOCIATION -SOUTHERN CALIFORNIA CHAPTER
simaAmpi m
330 - 1
MANHOLE SHAFT SAFETY LEDGE_
1 112-
Db+3'
i iOvESS
F.A% ��EFyI�
W. N0. 33366 >'a���„
a: EXPIRATION ;
;'. 6-30-2006 .'i
CIYI%.
X9l • . •��!\E•OF *CA�
TABLE0200-1.2 [A)
SIEVE SIZE
PERCENTAGE
PASSING SIEVE
1 112-
Db+3'
1.
-
3 4'
100
112m
90-100
318"
20-60
NO. 4
0-15
NO. 5
0-5
ASTM C 131
TEST GRADING
B
3- MAX SIZE NATIVE
SOIL COMPACTED 95%
6" MIN 6" MIN
10" MAX IO" MAX
as
6' MAX. SIZE
NATIVE SOIL -
COMPACTED 90%
i" MAX SIZE
SELECTED NATIVE
BEDDING COMPACTED
TO 90%
Q
SEWER VCP
1/2" CRASHED STONE BEDDING `t
PER STD SPECS FOR PUBUC I '
WORKS CONSMW 17 N TABLE
200 1.1 (AJ SHOW
TYPICAL BEDDING FOR SEWER VCP
10' OR DEEPER
NOT TO SCALE
Ob DIAMETER OF BELL
D - DIAMETER OF PIPE
SEWER ENCASEMENT
Nor T'0 SCALE
CITY OF FONTANA, CALIFORNIA
Q)HUSEWER'ONPR oOMENENT PLIA&I 8
Huitt-Zollars, Inc. Ontario DRAWN BY: SCALE:
PARCEL MAF' NO. `16264
HORIZ.:i 1101 S. MILLIKEN AVENUE, SUITE G ONTARIO, CALIFORNIA 91761 * (909) 390-8400 H -Z STAFF VRT.: 1'=
VSERRA Busmas PARK
DESIGNED BY:
TITLE SHEET DATE:
APPROVED BY MAURICE H. MURAD R.C.E. EXPIRES DATE M.H.M. 02-28-2005
11 CHECKED BY: AP -P OVED DWG. NO.:.57
f - j
33366 6-30-06 3_15.o5 M.H.M. c - �:F'S 3791
C ENGINEER R.C.E. 51152 DATE: 11
o�
3
N
a
N
2
/
0
0
Db+3'
MIN
,
4
N
a
N 3000 P.
CONCRETE
'
2-14 BARS TVP
581
0 BELL
�/
DETAILBEDDING ON 5#ET 1
SEWER VCP
1/2" CRASHED STONE BEDDING `t
PER STD SPECS FOR PUBUC I '
WORKS CONSMW 17 N TABLE
200 1.1 (AJ SHOW
TYPICAL BEDDING FOR SEWER VCP
10' OR DEEPER
NOT TO SCALE
Ob DIAMETER OF BELL
D - DIAMETER OF PIPE
SEWER ENCASEMENT
Nor T'0 SCALE
CITY OF FONTANA, CALIFORNIA
Q)HUSEWER'ONPR oOMENENT PLIA&I 8
Huitt-Zollars, Inc. Ontario DRAWN BY: SCALE:
PARCEL MAF' NO. `16264
HORIZ.:i 1101 S. MILLIKEN AVENUE, SUITE G ONTARIO, CALIFORNIA 91761 * (909) 390-8400 H -Z STAFF VRT.: 1'=
VSERRA Busmas PARK
DESIGNED BY:
TITLE SHEET DATE:
APPROVED BY MAURICE H. MURAD R.C.E. EXPIRES DATE M.H.M. 02-28-2005
11 CHECKED BY: AP -P OVED DWG. NO.:.57
f - j
33366 6-30-06 3_15.o5 M.H.M. c - �:F'S 3791
C ENGINEER R.C.E. 51152 DATE: 11
o�
3
N
a
N
2
/
0
0