HomeMy WebLinkAbout3757-1400 0 y � i i EXISTING POINT OF CONNECTION: 'C' &'D' 2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR TO INSTALL A 2" FEBCO 825Y REDUCED PRESSURE TYPE BACKFLOW PREVENTER AND LOCATE IN A LEMEUR VANDAL - RESISTANT STEEL MESH ENCLOSURE. COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN WITH SHRUBS) STATIC PRESSURE: 88. PSI @ 1539' ELEV. DESIGN PRESSURE: 68.4 PSI MAXIMUM DEMAND: 65 GPM EXISTING CONTROLLER: 'C' &'D' CONTRACTOR TO INSTALL (2) TORO SSA -K -48+48 -PSI -6 -N -S-4 FIELD SATELLITE CONTROLLERS. CONTROLLERS TO BE MUST INCLUDE A RADIO CONTROL AND PHONE MODEM. COORDINATE LOCATION WITH CITY INSPECTOR. LOCATE CONTROLLER'C' IN A STRONG BOX (SB-24SS-120V) AND CONTROLLER'D' IN A STRONG BOX (SB-24SS) (VERIFY WITH FIELD INSPECTOR PRIOR TO PURCHASE OR INSTALLATION) ENCLOSURE. SEE SITE ELECTRICAL PLANS. P.O.C. � -21/2 L L L II 2II 211 211 211 M F M r\ „ 4C TRA T N . 16541 -I NO, N r I O• T INN_ � N F?AG __ .1117 C AII LL--AUGUSTA�(q+ DRIVE04 Afo ir SO � - I 16 0 O • H I T cT \ w / NOTE: °' 610 " / 22 P�GvS� H CONTRACTOR TO PULL (2) LABELD COMMON WIRES AND ALL REMAINING CONTROLL WIRE STATION D15 -D24 (LABLED) TO THIS LOCATION. LOCATE IN A LABELED VALVE BOX(S) WITH WITH A 36" LOOP FOR ALL WIRES P.O.C. 21/4 L �Y 2II 211 211 211 ti POINT OF CONNECTION: 'E' &'F' 2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR TO INSTALL A 2" FEBCO 825Y REDUCED PRESSURE TYPE BACKFLOW PREVENTER AND LOCATE IN A LEMEUR VANDAL - RESISTANT STEEL MESH ENCLOSURE. COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN WITH SHRUBS) STATIC PRESSURE: 72.9 PSI DESIGN PRESSURE: 59.76 PSI MAXIMUM DEMAND: 32 GPM CONTROLLER: 'E'& 71' (STREETSCAPE) CONTRACTOR TO INSTALL (2) TORO SSA -K -48+48 -PSI -6 -N -S-4 FIELD SATELLITE CONTROLLERS. CONTROLLERS TO BE MUST INCLUDE A RADIO CONTROL AND PHONE MODEM. COORDINATE LOCATION WITH CITY INSPECTOR. CONTRACTOR TO PROVIDE 110v CONTINUOUS POWER AND TELEPHONE SERVICE PER CITY DIRECTION PRESSURE LOSS CALCULATIONS VALVE # E70 GPM 31 WATER METER (2') 0.8 SERVICE LINE 0.02 GATE VAL VES 1.4 BACKFLOW PREVENTER 12.0 MASTER VAL VE 0.0 VALVE 1.0 MAINLINE (960' 021/2') 2.88 LATERAL LINE 4.2 ELEVATION CHANGE (UP GRADE+ 1 1 ) 4.76 TOTAL PRESSURE LOSS 27.06 10 9 RESIDUAL PRESSURE REQUIRED 2.7 MINIMUM OPERATING PRESSURE 30 DESIGN PRESSURE REQUIRED 59.76 AVAILABLE PRESSURE (P.O.C.) 72.9 PSI RESIDUAL PRESSURE REMAINING + 13. 14 IRRIGATION DESIGN CRITERIA Name of Water Supplier: Fontana Water District 06/21/04 Pressure Given By MIKE MC CAW (909) 822-2201 - (JOSE) Pressure Given By KIETH HOUSTON (626) 448-6183 Static Pressure 88 PSI ® CITRUS AVE / SIERRA LAKES PARKWAY ( 1540 ELEV. ) 72.9 PSI AUGUSTA DR 200' N.O. MEDINAH (74.8 ELEV.) Contractor shall verify the static water pressure with supplier prior to installation. If different from PSI noted above, Contractor to notify Owner for instructions. Failure to do so will result in contractor being responsible for changes that might occur. PRESSURE LOSS CALCULATIONS VALVE # F24 GPM 30 WATER METER (2') 0.8 SERVICE LINE 0.02 GATE VALVES 1.4 BACKFLOW PREVENTER 12.0 MASTER VAL VE 0.0 VALVE 1.0 MAINLINE (1320' 021/2') 3.96 LATERAL LINE 4.8 ELEVATION CHANGE (DOWN GRADE+31 ') + 13.42 TOTAL PRESSURE LOSS 10.56 10 9 RESIDUAL PRESSURE REQUIRED 2.4 MINIMUM OPERATING PRESSURE 30 DESIGN PRESSURE REQUIRED 42.96 AVAILABLE PRESSURE (P.O.C.) 72.9 PSI RESIDUAL PRESSURE REMAINING +29.9 NOTE: CONTRACTOR TO PULL (2) LABELD COMMON WIRES AND ALL REMAINING CONTROLL WIRE STATION D25 -1332 (LABLED) TO THIS LOCATION. LOCATE IN A LABELED VALVE BOX(S) WITH WITH A 36" LOOP FOR ALL WIRES SCALE 1"_60' J9 I T e s C A P e S Landscape Architecture and Planning 3195-B Airport Loop Drive Costa Mesa, CA 92626 Richard Palhamus, License CA -#2782 (949) 644-9370 (714) 210-3140 FAX E� \,ANDSCA; ��� AbptiPO(-4 27 2 OF CA\�\ DVM L� DATE 06/09/04 JOB 04-024 13 of 14 w 00 � � d1 � o �O � 0.'.' 00 CCi � R E� \,ANDSCA; ��� AbptiPO(-4 27 2 OF CA\�\ DVM CHK DATE 06/09/04 JOB 04-024 13 of 14 12/22/04