HomeMy WebLinkAbout3735-32QUICK COUPLING VALVEO
LANDSCAPE ARCHMCTURE
60'7 Nloath Aflandm Boulevard
TORO SENTINEL MAP TO ASSEMBLY O FINISHED SURFACE
U1/ LOCKING COVER
R.P. BACKFLOW
SEE PLAN FOR NUMBER OF STATIONS. SLOPE TO DRAIN
10" ROUND VALVE BOX FINISH GRADE
ASSEMBLY
"Y" STRAINER
O 3/4" CONDUIT FOR GROUND O CONCRETE FOOTING
Lu
IuL,
FILTER SHUT-OFF
2' CONDUIT FOR UP TO OPTIONAL OMNI
O
-
ROUND PLASTIC BOX AND LOCKING COYER. COVER
C
9
co
24 FIELD WIRES DIRECTIONAL ANTENNA
O
SHALL BE BRANDED TO IDENTIFY GATE VALVE.
�" NIPPLE
�� PER SITE SURVEY
3/4 CONDUIT FOR INPUT POWER PER
DATE
O LOCAL 4 NATIONAL ELECTRIC CODES. RECOMMENDATIONS
1ST CITY SUBMITTAL
FINISH GRADE
HAND WHEEL (TURF AREA)
'" ELL
BRASS PLUG ENCLOSURE
$ 2" CONDUIT FOR 25-48 FIELD WIRES. 1-1/2" CONDUIT FOR
o o ANTENNA WIRE MIN.
01/20/05 3RD CITY SUBMITTAL
FINISH GRADE
wztx
�-►>� BRASS UNION
RADIUS ON SWEEP
SHALL
1/4'X 1/4"WIRE MESH
(SHRUB AREA)
1 BE 12"
®
2 PVC SCH. 80 OR
BRASS STREET ELBOW.
FINISH 0 npV�
GRADE � ��z CONC. SLAB
I/2" CONDUIT F
3 10 D OR
I 1 2)
BR CK ( OF <.
N �'''"��
SENSOR WIRES
PVC SCH e0 NIPPLE
PEA GRAVEL o o a a OR BRASS X2.
MAINLINE
BRASS NIPPLE
2
5
(MIN. 2 CU. FT.)
a" �" SCHEDULE 80
2 "
4
o o
.., ...• ....• •.•. . PVC COUPL ING
PVC 5CH.80 RISER
'•
a CONCRETE
'
Checked by.
PVC MALE 1/4" X 1/4" WIRE MESH
ADAPTOR
;' .
J
• ANCHOR :
44 •' � •:° e. .., A °'' " a• ADAPT TO MAIN LINE
9 1
PVC MAIN LINE
. ' ' r 0"- AS REQUIRED
PVC TEE
o BRICK (I OF 2)
Project Name:
. < . (o',MIN.
SEE "�
SIERRA BUSINESS CENTER
o v o o c
NOTE:
SPECS. e `
5CH.40 GALV. iso" STAKE UJ/ PVC SCH. 40 EL50W
GATE VALVE o PEA GRAVEL (MIN. 2 CU. FT.)
1, ALL PIPE AND FITTINGS SHALL BE BRASS UNLESS OTHERWISE SPECIFIED.
10
l2) TWO SPRINKLER TIES
)��
2. CONCRETE SHALL BE 420-C-2000.
9
3. THE BACKFLOW PREVENTER DEVICE AND INSTALLATION SHALL BE APPROVED BY
NOTES:
NOTES:
THE CITY OF WESTMINSTER. (114) 898-3311 EX. 8210 J. VILANDER
4, VALVE ASSEMBLIES MAY HAVE SCREWED FITTINGS OR FLANGED FITTINGS.
SEE
A. VALVE BOX LID SHALL BE BRANDED TO IDENTIFY GATE VALVE.
A. VALVE BOX LID SHALL BE BRANDED TO IDENTIFY GATE VALVE.
5. COAT ALL EXPOSED THREADS WITH AN APPROVED RUST INHIBITING SEALANT.
SPECS.
B. ATTACH DOMESTIC WATER IDENTIFICATION TAG, "WATER USED
B. ATTACH DOMESTIC WATER IDENTIFICATION TAG, "WATER USED
(o. APPROVED PLASTIC TAPE 1/2" WIDE SHALL BE USED ON ALL THREADED CONNECTIONS.
FOR IRRIGATION ONLY"
FOR IRRIGATION ONLY'
1. D1551MILAR METALS SHALL BE SEPARATED BY AN APPROVED DIELECTRIC COUPLING.
C. ACME THREADED PIPE TYPE DEVICE FOR DOMESTIC WATEE USE.
C. ACME THREADED PIPE TYPE DEVICE FOR DOMESTIC WATEE USE.
a• PLASTIC PIPE SHALL NOT BE USED ABOVE FINISH GRADE,
S. PAINT ASSEMBLE WITH FEDERALLY APPROVED SAFTY GREEN ENAMAL.
6" (0 6" 6
D. PIN LOCK TYPE DEVICE FOR DOMESTIC WATER USE,
D. PIN LOCK TYPE DEVICE FOR DOMESTIC WATER USE.
10. A BACKFLOW DEVICE CERTIFICATION IS REQUIRED BY THE CITY.
MIN. MIN. MIN. MIN.
OUIC< COIF
GATE VALVE
5AGN'FLOLU FfREVENTER
CONTIROLLER A55E�15L� (FELD. I I®UNT)
-24"�' EXACT LOCATION OF CONTROLLER SHALL
NOTE:
BE AGREED UPON BY EDISON, CITY
ALL POWER WIRES, GROUND WIRES ETC. SHALL BE
LANDSCAPE INSPECTOR PRIOR TO ANY
SEPARATELY SLEEVED AND SWEPT THROUGH
TRENCHING OR WIRE PLACEMENT.
ENCLOSED PAD WITH SCH 40 RIGID CONDUIT.
12
LEGEND:
3�" GENERAL NOTES:
ALL SLEEVING SHALL BE A MINIMUM OF 18" BELOW
PROVIDE 100A METER AND 50A/2P MAIN
FINISHED GRADE. ALL SLEEVING 15 A GRAPHIC
1. 10 DIAMETER CIRCULAR VALVE BOX
"
2. EDGE OF LAWN, WALK, FENCE, CURB, ETC_
24 COILED LOOPD
C:/5 WHERE INDICATED ON DRAWINGS.
�roo► REPRESENTATION OFA TTP. INSTALLATION.
3. 14" X 19' RECTANGULAR VALVE BOX
PROOF CONNECTION
WATERC1
PROVIDE PANEL BOARD WHERE INDICATED
SIZE OF EQUIPMENT = 4�o "lU x 18"D x 54" HIGH
4, 20" X 30' RECTANGULAR VALVE BOX
0OF 2)
ID TAG
FINISH ON DRAWINGS.
GRADE
SIZE OF CONCRETE SLAB = 52V 24"D x 8" THICK
VALVE BOX WITH COVER:
12" PROVIDE IRRIGATION CONTROLLER CABINET
W/ *4 REBAR AT 12' O,C. (TYP.)
IN
12 -INCH SIZE
WHERE INDICATED ON DRAWINGS.
4
NOTE.
A. CENTER VALVE BOX OVER VALVE TO
FINISH GRADE/TOP OF MULCH
� REMOTE CONTROL VALVE:
TERMINATE AT EXISTING HANDHOLE PER S.G.E.
COMPANY REQ., VERIFY EXACT LOCATION AN
r 8" DIA. X 12' DIA. BOTTOMLESS GROUND
,. ; WELL WITH PARKWAY COVER. FILL W1
� ��" •�"''"':r
3
FACILITATE SERVICING OF VALVE.
SUPERIOR 950 W1 LEMA 1525 ACTUATOR.
TERMINATION REQ, W1 S.C.E. CO.
90 SWEEP ELLSIF
'�• ��• PEA GRAVEL.
"
B. SET VALVE BOXES 2 MAX. ABOVE FINISH
3" MIN. y H S I (CLOSE)
N
PVC SC 0 NIPPLE
CONDUIT AND CONDUCTOR SIZES ARE BASED
5/s' DIA. X 10' DRIVEN GROUND ROD
GRADE IN MULCH COVER OR GROUNDCOVER.
PVC SCH 40 ELL
CONDUIT FOR ON NONMETALLEC CONDUIT AND COPPER
CONTROLLER CONDUCTORS WITH TYPE 'THHN/THWN"
seza oo°o
PER ARTICLE 250-81 OF 1990 NEC.
AREAS. SET FLUSH WITH FINISH GRADE
3
IN TURF AREAS.
WIRES. INSULATION.
PVC SCH 80 NIPPLE
I
10(op
SO SWEEP ELLS10" 15°
120 / 240
C. SET VALVE BOX AND VALVE ASSEMBLY IN
(LENGTH AS REQUIRED)
0 3W
GROUNDCOVER/SHRUB AREA WHERE
o
�0 0 00o�o�O�Q BRICK (1 OF 4)
IRRIGATION ELECTRIC METER
M 12 CIRCUIT EXTRA
POSSIBLE -INSTALL IN TURF ONLY IF THERE
CONTROL BOARD
PANEL PUMP CONCRETE
2
IS NO ADJACENT GROUNDCOVER.
SCH 80 NIPPLE l2 -INCH LENGTH,
HIDDEN) AND SCH 40 ELL
TEMPLATE MOUNTING
D. SET VALVE BOXES PARALLEL TO ONE
SIGNAL SLAB
r -ANOTHER AND PERPENDICULAR TO EDGE.
ELECTRIC METER
POIUER
FINISH
E. AVOIUD HEAVY COMPACTION OF SOIL
PVC MAINLINE PIPE
GRADE
PROVIDE 20 AMP CONDUIT FOR Gi�'OUN
� 2,
AROUND VALVE BOXES TO PREVENT THEIR
DEFORMATION/COLLAPSE.
PVC SCH 40 TEE OR ELL
STRONG BOX
MODEL NO. SB-24S5/120V 12"
ROD INSTALLATION
2 POLE BREAKER
PVC SCH 40 MALE ADAPTER
FOR NEW PUMPS
WHERE APPLICABLE 2 EXTRA 1" CONDUIT
PVC LATERAL PIPE
-
GROUND
3.0 -INCH MINIMUM DEPTH OF
3/4 -INCH WASHED GRAVEL
90 SWEEP ELLS
90 SWEEP ELLS
3/411C 1/6
FOR
ELECTRICAL
/,�•
CONDUIT FOR CONTROLLER UJIRES
CAVORT VALVE 5OX INFALLTION
fRFICTE CONTfRCL VALVE
ELECTRIC �IETEIR ENCL05URE
E
ELECTRIC DETER ENCL05URE
APPROVED BACKFILL
BRANDING GUIDE
FINISH GRADE
APPROVED BACKFILL
MPR PLUS NOZZLE
5105 SHRUB SPRAY NOZZLE
DW RW C L O
6„ ol HARDSCAPE CURB, WALK, OR
(SIZE PER PLAN)
OA EA O E E
FINISH GRADE
MIN FOUNDATION
MT C T N T 5
EE LE TT f
MPR PLUS NOZZLE
` ' ''° '' '°
TORO 51OZ-PRX SERIES -5 SPRINKLER
SR AR R E G
HARDSCAPE CURB, WALK, OR
�
=1 I I 1=1 11=1 I I =1 11=1 11=1 11=1 I �' .•' .:
:III=1�-III-III-II III -III -III -III- '° •'�°,°'
11=1 I I 1=1 I I-1 III -1 I I-1 11=1 I I-1 I ''%
o PVC SCH. 80 RISER
T I OR N
I M L A
MIN. FOUNDATION
-1 -1I , ;,: ,; .-
. '..
o a
C E L T
1M1...
_ °.'
=1 ; ':;
•'
Nz ~^3 C ADV IN RISER (AS REQUIRED)
o
C,OR PVC SCH. 40 COUPLING
D E f
R O
11= 1=1 11=1 I I I I I=1 1=1 11=1 11= '' ; ;;''
1=1 11=1 I I-1 I I-1 I_ I I-1 11=1 11=1 11=1 I I.: • ,. , °. •
TORO 5102 PRX SERIES SPRAT
� ``�
N
....:
11-I i l -III -1 1-1 1 1 1-1 1-1 1 hI I I- '° ••
• ° A.
FINISH GRADE
DW RW COMM COMMUNICATION SPLICES
Diu Rau GR GROUNDING RODS
TORO 5102 PRX SERIES SPRAY
1=111=111-111=III=III III=III-III=III=III=.1- APPROVED BACKFILL
11=1I 1=1I 11=1I 11=1 11=1 I I-1 I-
DlU R1,U (STATION) REMOTE CONTROL VALVES
=1 11=1 I—I 1=1 11=1 I
I—III—III—III-III=III — — — — PVC SCH. aO RISER
Dw RW MV MASTER VALVES
DW RI,U A FLOW SENSORS
Nz PVC SCH. 80 RISER
PVC SCH. aO RISER
2 PVC SCH 40 ELLS.
DW RW GV GATE VALVES
^� 2 PVC SCH 40 ELLS,
2 PVC SCH 40 ELLS.
'z ( T 4 T) AND PVC SCH. 80
� THREADED NIPPLE
DW RW F1 FERTILIZER INJECTORS
( T 4 T) AND PVC SCH. 80
---- ( T 4 T) AND PVC 5CH. 80
PVC SCH. aO NIPPLE
DW RW BS BASKET STRAINERS
- THREADED NIPPLE
THREADED NIPPLE
DW RW MS MOISTURE SENSORS
PVC SCH, 80 NIPPLE
PVC SCH, 80 NIPPLE
LATERAL TEE
PVC SCH. 40 STREET ELL.
DW RJ SB SPLICE BOX
DJ RW QC QUICK COUPLERS
LATERAL TEE
LATERAL TEE
DW RW FVA FLUSH VALVE ASSEMBLY
PVC SCH. 40 STREET ELL.
PVC SCH. 40 STREET ELL.
LATERAL PIPE
NOTE:
f3FNANDING GUIDE
A. INSTALL HEADS 12' ABOVE GRADE IN THE INTERIOR OF PLANTING BEDS.
LATERAL PIPE
NOTE:
LATERAL PIPE
NOTE:
B. ALL SHRUB SPRAYS ON RISERS ARE FOR INSTALLATION ALONG WALL$
AND FENCES, AND INTERIOR PLANTINGS AREAS ONLY.
I T Y OF F
INSTALL SPRINKLER AT FINISH GRADE.
INSTALL SPRINKLER AT FINISH GRADE.
C. INSTALL SPRINKLER A50VE FINISH GRADE,
vf-C
DRAWN BY:
SCALE:
GF
IRRIGATION -PLAN
: TENTATIVE PARCEL NrO. 16264
1"=20'
DESIGNED B
DATE:
04
� �LTURF
I I
5PFAY FOF-UP
54RUE3 5 C�l�
'�1"'I l� 5FRA"*� OI � fZ5ER
PLAN�Ci�CK N 04�-y(�0 9
CHECKED BYRK
DWG. N
APPROVE
4��
3735
,3
CITY ENgNEER R.C.E.
50
kobcft
0s '
LANDSCAPE ARCHMCTURE
60'7 Nloath Aflandm Boulevard
Abaheim, CaNfornia. 92805
PpiONE: (714) 520-5795
FAX (714) 520-0106
Erynail: lro et
CA. LTC. NO. 1219
�PNDSCAPF
2��.0 ��,ti KpBATq q,O q�,A�y✓,
-31-05
RENEVAL DATE
CA
Lu
IuL,
C
9
co
D D ILL.
a
H
y
DATE
1ST CITY SUBMITTAL
11/09/04 2ND CITY SUBMITTAL
01/20/05 3RD CITY SUBMITTAL
REVISIONS
Drawn by. CF
Checked by.
Approved by. RK
Date:
Project No.: LEN 401
Project Name:
SIERRA BUSINESS CENTER
Sheet Title:
RR11GATION
D TALL
Sheet No:
0