Loading...
HomeMy WebLinkAbout3735-280 T) SEE SHEET U -z �z�D irole i IST 50+ � TSTA: 20+ ICL INET -E -R CTIC I I I I Lu - �� Zg I I Q I J � M SEE SHEET LI -1 It SL_ V, In 11" In T 0:4015M Mud, ST1�AAI LIMIT OF WORD 3n In 4 SCBE SHEET LSD -13 r (O" SL -V.) /u I .a, 22J 33 33 23J 13 29J 1 2 Lull V, 1-1/2" 1-1/2" 1" 2 /21n -�- 3nn 3n 3n In In I 1 n in in 3n44 3 n n jn n 4 PROBED R/W LIMIT OF WORK � Lu Mw I 22n 21 n 22n II " 2 SL- V I , 26 27 n R-4 NoLngn�y G=r Imp rff!7r II _Ji I I U Z r 2 2 n l ro 11 SLV. i i 1 14 2" ui SLV. III 1 I 1 12 " SL- V, 29 30 i i i� l — — N — --I-- — — --{— — — — SL -V -iii i 1 1 STA. 3 +()7.86 "A" I I I/ I I Z I STA: + 2.86 "B" 2 WIRE SL.V_ 211 5L V, 311 0 CL I S --CTION 2111 III 1 1 2 , , U� 30role L� 3" iln �" 111 In 1�J 33` 33 16J 1 1-1/2' 5L.V 1 z � a E X I5T ING CONDITION NOTES SEE SHEET LI -12 CONTRACTOR SHALL PROVIDE TEMPORARY INSTALLATION AS NECESSARY TO MAINTAIN EXISTING IRRIGATION SYSTEM FULLY OPERATIONAL DURING CONSTRUCTION. CONTRACTOR SHALL PROTECT -IN-PLACE ALL EXISTING IRRIGATION SYSTEMS. CONTRACTOR SHALL REPAIR OR REPLACE ALL IRRIGATION COMPONENTS AT HIS OWN EXPENSE AND SYSTEMS DAMAGEDDURING CONSTRUCTION, CONTRACTOR SHALL PROTECT -IN-PLACE ALL EXISTING PLANT MATERIAL. CONTRACTOR SHALL REPLACE ALL PLANT MATERIALS DAMAGED OR DESTROYED DURING CONSTRUCTION AT HIS OWN EXPENSE. CONTRACTOR SHALL PROTECT -IN-PLACE ALL EXISTING CONTROL WIRES TO THE EXISTING CONTROLLERS. CONTRACTOR SHALL PRESERVE ALL ABANDON CONTROL WIRES TO BE UTILIZED IF NECESSARY FOR NEW VALVES. CONTRACTOR SHALL PROVIDE NEW WIRES AND TRENCHING PER DETAIL TO ALL NEW CONTROL VALVES. WIRES ARE TO BE TRENCHED BACK TO THE EXISTING CONTROLLER AND INSTALLED PER DETAIL. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK AND SHALL NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO BEGINNING CONSTRUCTION. RECORD DRAWINGS ARE AVAILABLE FOR REVIEW IN THE BACK OF TH15 PACKAGE, DRAWINGS ARE FOR REFERENCE ONLY AND DOES NOT CONSTITUTE THE ACTUAL BUILT CONDITION. CONTRACTOR TO VERIFY ALL CONDITIONS IN THE FIELD. CONTRACTOR TO INSTALL THE MASTER CONTROL CABLE, DIRECT BURIAL AND RUN IN THE SAME TRENCH AND PARALLEL TO MAINLINE. WHERE CABLE IS NOT IN TRENCH WITH MAINLINE, ENCLOSE IN 2' PVC CONDUIT, TYPICAL - ALL PIPING SHOWN IN PAVED AREAS ARE FOR DIAGRAMMATIC PURPOSES ONLY AND ARE TO BE INSTALLED IN PLANTING AREAS WHEREVER POSSIBLE. CONTRACTOR SHALL ADJUST THE SPRAY PATTERNS BY INSTALLING THE APPROPRIATE PRESSURE COMPENSATING SCREENS, PRIOR TO USING THE ADJUSTING SCREW. CONTRACTOR SHALL GUARANTEE THE SURVIVAL OF ALL PLANT MATERIAL WHILE INSTALLING THE NEW IRRIGATION SYSTEM, THE CONTRACTOR SHALL ALSO GUARANTEE THE SURVIVAL OF ALL PLANT MATERIAL WHILE RETROFITTING THE EXISTING IRRIGATION SYSTEM. SEE SHEET LI -17 F0� IRRIGATION LEC�EN©AND GENERAL IRRIGATI0�1 NOTES.IMII KEYMAP: i , ? J L - SANTA ANA AVE. n -l•• T pis assolqWPOWNPUMkobcftA1,..,, LANDSCAPE ARCHITECTURE 607 North Anaheim Bo wevard Anaheim, CaufornhL 92805 =7-.(714) 520-5795 (714) 520-0106 Email: 11o1L.—I er@earthUnl-aet CA.1dC. NO. 1219 �PNDS AA PF 41, A u 12-31-05 RMVAL DATE F of C A�ZFp� o A C3 n� o o C. DATE 1ST CITY SUBMITTAL 11/09/04 2ND CITY SUBMITTAL 01 20 05 3RD CITY SUBMITTAL REVISIONS Drawn by. GF Checked by: Approved by: RK Scale: 1"=20'–O" Date: Project No.: LEN 401 Project Name: SIERRA BUSINESS CENTER Sheet Title: DRGQ3 GAMON PLAN TECHNOLOGY STREET Sheet No: C] SLOVER AVE z Q W Q > Q w a ui V p z rtrH a t SOTREET i , ? J L - SANTA ANA AVE. n -l•• T pis assolqWPOWNPUMkobcftA1,..,, LANDSCAPE ARCHITECTURE 607 North Anaheim Bo wevard Anaheim, CaufornhL 92805 =7-.(714) 520-5795 (714) 520-0106 Email: 11o1L.—I er@earthUnl-aet CA.1dC. NO. 1219 �PNDS AA PF 41, A u 12-31-05 RMVAL DATE F of C A�ZFp� o A C3 n� o o C. DATE 1ST CITY SUBMITTAL 11/09/04 2ND CITY SUBMITTAL 01 20 05 3RD CITY SUBMITTAL REVISIONS Drawn by. GF Checked by: Approved by: RK Scale: 1"=20'–O" Date: Project No.: LEN 401 Project Name: SIERRA BUSINESS CENTER Sheet Title: DRGQ3 GAMON PLAN TECHNOLOGY STREET Sheet No: C]