HomeMy WebLinkAbout3684LT-1V6
0
1
0
I
AC
C.L.
EX.
FF
FG
FS
FH
FL
G
GB
HP
INV
LID
LF
MAX
MH
MIN
PL
PA
R/W
S=
SD
SWR
ss
TC
TF
TG
Tw
TYP
W
wm
wV
LEGEND AND ABBREVIATIONS:
ASPHALT CONCRETE
CENTERLINE
EXISTING
LIST
EXISTING
-STORM DRAIN
PACIFIC BELL CO.
FINISHED FLOOR
AT THE NEC FOOTHILL BLVD. AND
EXISTING
WATER PIPELINE
COMMUNITIES, INC.
FINISHED GRADE
FEET EAST OF
UNDERGROUND SERVICE ALERT
1981 W, LUGONIA AVENUE
EAST AVE., SET DRIVE PIN W/C,S,
FINISHED SURFACE
2 ADA,
EXISTING
SEWER LINE
IRVINE,
FIRE HYDRANT
#54-379 OVER ETIWANDA FLOOD
EXISTING
GAS LINE
790-5400
FLOW LINE
EXISTING
ELECTRICAL CONDUIT
ELEVATION. 1194,630
GAS
909 875-5100 - TRANSMISSION
EXISTING
TELEPHONE CONDUIT
(800) 227-2600
GRADE BREAK
EXISTING
MANHOLE (MH, SDMH or EMH)
HIGH POINT
INVERT ELEVATION
EXISTING
FIRE HYDRANT
(909) 9872591
LOCAL DEPRESSION
EXISTING
VALVE
LINEAL. FEET
MAXIMUM
EXISTING
STREET LIGHT
MANHOLE
EXISTING
CONTOUR
MINIMUM
PROPERTY LINE
PROPOSED CONTOUR
PLANTED AREA
TRACT BOUNDARY
LEGEND FOR STREET LIGHTS.
1e ORNAMENTAL. STREET LIGHT POLE SHALL BE MARSELITE OR APPROVED EQUAL.
2, THE LUMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FT< OR
8 FT. MAST ARM, 15 FT, MAST ARM REQUIRED FOR STREET LIGHTS ON TRAFFIC
SIGNAL POLE INSTALLATIONS,
3, ANY CHANGE IN LOCATION OR STREET LIGHTS FROM THE APPROVED PLANS IS
SUBJEc"r TO APPROVAL BY THE CITY ENGINEER,
4, SIDEWALK WIDTHS 'TO BE PER APPROVED STREET IMPROVEMENT PLANS, A MINIMUM
OF 4 FEET UNOBSTRUCTED SIDEWALK CLEARANCE REQUIRED BEHIND STREET LIGHT POLE,
5, ALL LIGHTS SHALL BE INSTALLED PER CITY OF FONTANA STD DWG, NO. 1016
1. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS1611-IT-( FOR
JOB SITE CONDITIONS DURING THE COURSE OF' CONSTRUCTION, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY, THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS, THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND
HOLD THE OWNER AND ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR
ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER,
2. ALL UNDERGROUND UTILITIES OR STRUCTURES, REPORTED OR FOUND ON PUBLIC RECORDS,
ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY
ACCEPTING THESE PLANS OR PROCEEDING WITH THE IMPROVEMENTS HEREON, AGREES TO
ASSUME LIABILITY AND TO HOLD THE ENGINEER HARMLESS FOR ANY DAMAGES RESULTING
FROM THE EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED OR
INDICATED ON PUBLIC RECORDS, OR THOSE CONSTRUCTED AT VARIANCE WITH REPORTED
OR RECORDED LOCATIONS, THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHERS FOUND AT
THE SITE, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF
ALL UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK,
3, THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR
UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL, CHANGES TO THE PLANS MUST
BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS,
4. THE ENGINEER DOES NOT RECOMMEND OR ENDORSE THE USE OF ASBESTOS --CEMENT WATER
PIPE OR ANY PRODUCTS CONTAINING ASBESTOS DUE TO THE HEALTH HAZARD CONNECTED
WITH SUCH PRODUCTS, SPECIFICATION HEREON OF ANY SUCH PRODUCT IS AT THE DIRECTION
OF THE JURISDICTIONAL AGENCY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL
CONSTRUCTION, CONNECTION AND REMOVAL OF ASBESTOS PRODUCTS AND SHALL FOLLOW ALL
AND E.P.A. GUIDELINES TO MINIMIZE HEALTH HAZARDS,
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS AND
CONDITIONS SHOWN HEREON AT THE JOB SITE PRIOR TO ANY CONSTRUCTION, FUSCOE
ENGINEERING, INC. SHALL BE NOTIFIED OF ANY DISCREPANCIES, REVISIONS TO THE PLAN
SHALL BE APPROVED BY THE ENGINEER IN WRITING PRIOR TO IMPLEMENTATION.
6
z
0
M
,I DIG ALERT
U
o DIAL TOLL FREE
7-
u 1-800-227-2600
AT LEAST TWO DAYS
"I
6� BEFORE YOU DIG
■
�p
le,
PREPARED FOR:
LIST
BENCH MARK:
CITY OF FONTANA
PACIFIC BELL CO.
8353 SIERRA AVENUE
AT THE NEC FOOTHILL BLVD. AND
EAST AVE., 4-3 FEET
FIELDSTONE
COMMUNITIES, INC.
NORTH OF CL. FOOTHILL BLVD, 60
FEET EAST OF
UNDERGROUND SERVICE ALERT
1981 W, LUGONIA AVENUE
EAST AVE., SET DRIVE PIN W/C,S,
TAG IN APPROX.
2 ADA,
SUITE 200
CENTER 'TOP OF EAST WINGWALL FOR BRIDGE
IRVINE,
CA 92618
#54-379 OVER ETIWANDA FLOOD
CHANNEL,
(949)
790-5400
300 N. PEPPER AVENUE
RIALTO, CA 92376
GENERAL TELEPHONE COMPANY
ELEVATION. 1194,630
1400 E. PHILLIPS BLVD.
PREPARED BY:
COMMUNITIES
14-4-63 26
STREET I-!G—lqT
LL
HIGHLAND AVENUE
uj w
114
z
! Ut
CITY OF
FONTANA
S, PACIFIC RAILROAD
BEUNE VENUE BASE LINE AVENUE
CITY OF
RANCHO
CUCAMONGA W,
Ml LER AVENU 40"
/LER
LVENU
OTHILL BOULEVARD
COUNTY OF SAN BERNARDINO
kRR C W H G*iW, W
VICINITY MAP
NTs
( IN FEET )
I inch ,= 40 ft
CONSTRUCTION NOTES
NO, DESCRIPTION QUANTITY UNIT
CONSTRUCT 5800 LUMEN HPV 70 WATT #7 STREET LIGHT PER CITY OF 9 EA
FONTANA STD. DWG, NO, 1016
NOTE:
QUANTITIES SHOWN HEREON ARE FOR PERMIT AND/OR BONDING PURPOSES ONLY AND SHALL NOT BE
USED FOR BIDDING, CONTRACTOR SHALL DETERMINE 'THEIR OWN QUANTITIES AND BID A COMPLETE JOB,
-CITY OF FONTANA MILITY
LIST
-
CITY OF FONTANA
PACIFIC BELL CO.
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5467
SO. CAL. GAS COMPANY
UNDERGROUND SERVICE ALERT
1981 W, LUGONIA AVENUE
(800) 227-2600
REDLANDS, CA 92374
(909) 335--7547
COMCAST (CABLE TV)
EMERGENCIES: (800) 427-2200
1205 DUPONT AVE,
ONTARIO, CA 91761
SO, CAL. EDIISON COMPANY
(909) 390--4738
300 N. PEPPER AVENUE
RIALTO, CA 92376
GENERAL TELEPHONE COMPANY
9091 820-5598 - UNDERGROUND
1400 E. PHILLIPS BLVD.
909 875-5100 - TRANSMISSION
ONTARIO, CA 91766
909 637-1233 - PIPELINES
1
(800) 227-2600
909 357-6223 - DI5TIBUTION
CUCAMONGA VALLEY WATER DISTRICT
10440 ASHFORD STREET
RANCHO CUCAMONGA, CA 91729
(909) 9872591