Loading...
HomeMy WebLinkAbout3684LT-1V6 0 1 0 I AC C.L. EX. FF FG FS FH FL G GB HP INV LID LF MAX MH MIN PL PA R/W S= SD SWR ss TC TF TG Tw TYP W wm wV LEGEND AND ABBREVIATIONS: ASPHALT CONCRETE CENTERLINE EXISTING LIST EXISTING -STORM DRAIN PACIFIC BELL CO. FINISHED FLOOR AT THE NEC FOOTHILL BLVD. AND EXISTING WATER PIPELINE COMMUNITIES, INC. FINISHED GRADE FEET EAST OF UNDERGROUND SERVICE ALERT 1981 W, LUGONIA AVENUE EAST AVE., SET DRIVE PIN W/C,S, FINISHED SURFACE 2 ADA, EXISTING SEWER LINE IRVINE, FIRE HYDRANT #54-379 OVER ETIWANDA FLOOD EXISTING GAS LINE 790-5400 FLOW LINE EXISTING ELECTRICAL CONDUIT ELEVATION. 1194,630 GAS 909 875-5100 - TRANSMISSION EXISTING TELEPHONE CONDUIT (800) 227-2600 GRADE BREAK EXISTING MANHOLE (MH, SDMH or EMH) HIGH POINT INVERT ELEVATION EXISTING FIRE HYDRANT (909) 9872591 LOCAL DEPRESSION EXISTING VALVE LINEAL. FEET MAXIMUM EXISTING STREET LIGHT MANHOLE EXISTING CONTOUR MINIMUM PROPERTY LINE PROPOSED CONTOUR PLANTED AREA TRACT BOUNDARY LEGEND FOR STREET LIGHTS. 1e ORNAMENTAL. STREET LIGHT POLE SHALL BE MARSELITE OR APPROVED EQUAL. 2, THE LUMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FT< OR 8 FT. MAST ARM, 15 FT, MAST ARM REQUIRED FOR STREET LIGHTS ON TRAFFIC SIGNAL POLE INSTALLATIONS, 3, ANY CHANGE IN LOCATION OR STREET LIGHTS FROM THE APPROVED PLANS IS SUBJEc"r TO APPROVAL BY THE CITY ENGINEER, 4, SIDEWALK WIDTHS 'TO BE PER APPROVED STREET IMPROVEMENT PLANS, A MINIMUM OF 4 FEET UNOBSTRUCTED SIDEWALK CLEARANCE REQUIRED BEHIND STREET LIGHT POLE, 5, ALL LIGHTS SHALL BE INSTALLED PER CITY OF FONTANA STD DWG, NO. 1016 1. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONS1611-IT-( FOR JOB SITE CONDITIONS DURING THE COURSE OF' CONSTRUCTION, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ENGINEER, 2. ALL UNDERGROUND UTILITIES OR STRUCTURES, REPORTED OR FOUND ON PUBLIC RECORDS, ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY ACCEPTING THESE PLANS OR PROCEEDING WITH THE IMPROVEMENTS HEREON, AGREES TO ASSUME LIABILITY AND TO HOLD THE ENGINEER HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED OR INDICATED ON PUBLIC RECORDS, OR THOSE CONSTRUCTED AT VARIANCE WITH REPORTED OR RECORDED LOCATIONS, THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHERS FOUND AT THE SITE, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF ALL UTILITIES OR STRUCTURES CONCERNED BEFORE STARTING WORK, 3, THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL, CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS, 4. THE ENGINEER DOES NOT RECOMMEND OR ENDORSE THE USE OF ASBESTOS --CEMENT WATER PIPE OR ANY PRODUCTS CONTAINING ASBESTOS DUE TO THE HEALTH HAZARD CONNECTED WITH SUCH PRODUCTS, SPECIFICATION HEREON OF ANY SUCH PRODUCT IS AT THE DIRECTION OF THE JURISDICTIONAL AGENCY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL CONSTRUCTION, CONNECTION AND REMOVAL OF ASBESTOS PRODUCTS AND SHALL FOLLOW ALL AND E.P.A. GUIDELINES TO MINIMIZE HEALTH HAZARDS, 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN HEREON AT THE JOB SITE PRIOR TO ANY CONSTRUCTION, FUSCOE ENGINEERING, INC. SHALL BE NOTIFIED OF ANY DISCREPANCIES, REVISIONS TO THE PLAN SHALL BE APPROVED BY THE ENGINEER IN WRITING PRIOR TO IMPLEMENTATION. 6 z 0 M ,I DIG ALERT U o DIAL TOLL FREE 7- u 1-800-227-2600 AT LEAST TWO DAYS "I 6� BEFORE YOU DIG ■ �p le, PREPARED FOR: LIST BENCH MARK: CITY OF FONTANA PACIFIC BELL CO. 8353 SIERRA AVENUE AT THE NEC FOOTHILL BLVD. AND EAST AVE., 4-3 FEET FIELDSTONE COMMUNITIES, INC. NORTH OF CL. FOOTHILL BLVD, 60 FEET EAST OF UNDERGROUND SERVICE ALERT 1981 W, LUGONIA AVENUE EAST AVE., SET DRIVE PIN W/C,S, TAG IN APPROX. 2 ADA, SUITE 200 CENTER 'TOP OF EAST WINGWALL FOR BRIDGE IRVINE, CA 92618 #54-379 OVER ETIWANDA FLOOD CHANNEL, (949) 790-5400 300 N. PEPPER AVENUE RIALTO, CA 92376 GENERAL TELEPHONE COMPANY ELEVATION. 1194,630 1400 E. PHILLIPS BLVD. PREPARED BY: COMMUNITIES 14-4-63 26 STREET I-!G—lqT LL HIGHLAND AVENUE uj w 114 z ! Ut CITY OF FONTANA S, PACIFIC RAILROAD BEUNE VENUE BASE LINE AVENUE CITY OF RANCHO CUCAMONGA W, Ml LER AVENU 40" /LER LVENU OTHILL BOULEVARD COUNTY OF SAN BERNARDINO kRR C W H G*iW, W VICINITY MAP NTs ( IN FEET ) I inch ,= 40 ft CONSTRUCTION NOTES NO, DESCRIPTION QUANTITY UNIT CONSTRUCT 5800 LUMEN HPV 70 WATT #7 STREET LIGHT PER CITY OF 9 EA FONTANA STD. DWG, NO, 1016 NOTE: QUANTITIES SHOWN HEREON ARE FOR PERMIT AND/OR BONDING PURPOSES ONLY AND SHALL NOT BE USED FOR BIDDING, CONTRACTOR SHALL DETERMINE 'THEIR OWN QUANTITIES AND BID A COMPLETE JOB, -CITY OF FONTANA MILITY LIST - CITY OF FONTANA PACIFIC BELL CO. 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 SO. CAL. GAS COMPANY UNDERGROUND SERVICE ALERT 1981 W, LUGONIA AVENUE (800) 227-2600 REDLANDS, CA 92374 (909) 335--7547 COMCAST (CABLE TV) EMERGENCIES: (800) 427-2200 1205 DUPONT AVE, ONTARIO, CA 91761 SO, CAL. EDIISON COMPANY (909) 390--4738 300 N. PEPPER AVENUE RIALTO, CA 92376 GENERAL TELEPHONE COMPANY 9091 820-5598 - UNDERGROUND 1400 E. PHILLIPS BLVD. 909 875-5100 - TRANSMISSION ONTARIO, CA 91766 909 637-1233 - PIPELINES 1 (800) 227-2600 909 357-6223 - DI5TIBUTION CUCAMONGA VALLEY WATER DISTRICT 10440 ASHFORD STREET RANCHO CUCAMONGA, CA 91729 (909) 9872591