HomeMy WebLinkAbout3681-2MANOR,
� NVII
j
WIFRIZ31,11,S',
Match Line"'Al See Thins Sheet
Match Line T See Sheet L-3
All Work to Meet or Exceed State & Local Codes and Industry Standards.
Written Dimensions to Precede Scaled Dimensions.
UNDERGROUND UTILITIES:
The Contractor shall be responsible for locating or verifying locations of all existing utilities, and for protection of same. Damages resulting from Contractor's work
or that of Contractor's sub -contractors shall be restored to original condition at their own expense. City shall have the final say if repairs are to be made by
Contractor or others.
Station number
Gallons per minute Valve size
Detail/ section number
Sheet number
Equipment Legend SEE IRRIGATION DETAILS, SHEET L-12
SYMBOL DESCRIPTION
X New 2" Water Metj-
Gate valve
Nibco T-113, line size
Mainline PVC. SCH. 40 up to 1-1/2",
Class 315 2" & up
Lateral Line PVC. Class 200 3/4" Thru 1-1/2"
Irrigation Sleeve PVC. SCH. 40 at 2-1/2"
X Dia. of Pipe
master Control Valve
Rain -Bird 200 -GB, 2"
Flow Sensor
Rain -Bird FS200P, 2"
SYMBOL
Remote control valve
MODEL
Superior 950 -DW, 1 -'2"
NOZZLE
Quick coupling valve
G.P.M.
Rain -Bird 33 -DRC, Line Size
PATTERN
Automatic irrigation controller
Rainbird
Toro in Strong Box enclosure
12" pop-up
SSAK48PS1 6NS1, 48 Station
8'
Reduce Pressure Backflow Preventer
30
Febco, 825 Y, 112" , Brass
Flow Sensor
Rain -Bird FS200P, 2"
SYMBOL
MANUFACTURER
MODEL
DESCRIPTION
NOZZLE
RADIUS
G.P.M.
P.S.I.
PATTERN
Rainbird
1800 -SAM
12" pop-up
8_Q
8'
0.26
30
90'
B.F.P.
Rainbird
1800 -SAM
12'' pop-up
B -T
81
0.35
30
1350
2500'
Rainbird
1800 -SAM
12" pop-up
8-H
81
0.52
30
180'
ELEVATION
Rainbird
1800 -SAM
12" pop-up
10-0
10,
0.39
30
90'
Rainbird
1800 -SAM
12" pop-up
10-T
10,
0.53
30
135'
LL�
Rainbird
1800 -SAM
121' pop-up
10-H
10,
0.79
30
180,
Irrigation Notes
1) Mainline, wires and lateral lines shall be sleeved under all driveways and walkways.
2) The irrigation equipment is shown in the street/ hardscape areas for clarification only. Actual equipment shall
be placed within landscape areas. Valve boxes and equipment installed above ground to be placed in shrub/
ground cover areas where possible.
3) Sprinkler heads shall be as indicated on the drawings. Six inch (6) pop-up type spray heads shall be
installed in all lawn areas. Twelve inch (12") pop-up type spray heads shall be installed in all ground cover/
shrub areas.
4) Irrigation system shall always be isolated from domestic system with use of an approved backflow device.
114,11111111 1111#011111111
T
EXISTING STATIC PRESSURE (psi) : 85
COMPONENT
SIZE
GPM
LENGTH
LOSS/1 00'NET
L
L 'SS
WATER METER
2"
40
—
130
COPPER SERVICE LINE
21
01
110
0.85
B.F.P.
Y2
12.0
MAINLINE
31
2500'
0.17
4.25
CONTROL VALVE
1-X°
—
2.70
ELEVATION
43-33
7.37
LATERALS
5.0
SUBTOTAL: 3147
25% PRESSURE ALLOWANCE FOR FITTINGS: 837
SPRINKLER OPERATING PRESSURE: 30.0
TOTAL PRESSURE LOSS (psi): 71.84 11
Irrigation Plan
Scale: V=20' North
Landscape Architecture
Urban Design & Planning
181 N.'E'Street, Son Bernardino, CA 92401
phone: (909) 888-5568
fox: (909) 384-9854
e-mail: rpe.1c'4verizon.net
Richard Pope, Landscape Architect CAff 2664
51qcp-t DC5r_ription:
Date: July 26, 2004
Sheet:
.0
CL
TIME
U.
co
r4ft
cc
Ci
law
E
51qcp-t DC5r_ription:
Date: July 26, 2004
Sheet: