Loading...
HomeMy WebLinkAbout3681-2MANOR, � NVII j WIFRIZ31,11,S', Match Line"'Al See Thins Sheet Match Line T See Sheet L-3 All Work to Meet or Exceed State & Local Codes and Industry Standards. Written Dimensions to Precede Scaled Dimensions. UNDERGROUND UTILITIES: The Contractor shall be responsible for locating or verifying locations of all existing utilities, and for protection of same. Damages resulting from Contractor's work or that of Contractor's sub -contractors shall be restored to original condition at their own expense. City shall have the final say if repairs are to be made by Contractor or others. Station number Gallons per minute Valve size Detail/ section number Sheet number Equipment Legend SEE IRRIGATION DETAILS, SHEET L-12 SYMBOL DESCRIPTION X New 2" Water Metj- Gate valve Nibco T-113, line size Mainline PVC. SCH. 40 up to 1-1/2", Class 315 2" & up Lateral Line PVC. Class 200 3/4" Thru 1-1/2" Irrigation Sleeve PVC. SCH. 40 at 2-1/2" X Dia. of Pipe master Control Valve Rain -Bird 200 -GB, 2" Flow Sensor Rain -Bird FS200P, 2" SYMBOL Remote control valve MODEL Superior 950 -DW, 1 -'2" NOZZLE Quick coupling valve G.P.M. Rain -Bird 33 -DRC, Line Size PATTERN Automatic irrigation controller Rainbird Toro in Strong Box enclosure 12" pop-up SSAK48PS1 6NS1, 48 Station 8' Reduce Pressure Backflow Preventer 30 Febco, 825 Y, 112" , Brass Flow Sensor Rain -Bird FS200P, 2" SYMBOL MANUFACTURER MODEL DESCRIPTION NOZZLE RADIUS G.P.M. P.S.I. PATTERN Rainbird 1800 -SAM 12" pop-up 8_Q 8' 0.26 30 90' B.F.P. Rainbird 1800 -SAM 12'' pop-up B -T 81 0.35 30 1350 2500' Rainbird 1800 -SAM 12" pop-up 8-H 81 0.52 30 180' ELEVATION Rainbird 1800 -SAM 12" pop-up 10-0 10, 0.39 30 90' Rainbird 1800 -SAM 12" pop-up 10-T 10, 0.53 30 135' LL� Rainbird 1800 -SAM 121' pop-up 10-H 10, 0.79 30 180, Irrigation Notes 1) Mainline, wires and lateral lines shall be sleeved under all driveways and walkways. 2) The irrigation equipment is shown in the street/ hardscape areas for clarification only. Actual equipment shall be placed within landscape areas. Valve boxes and equipment installed above ground to be placed in shrub/ ground cover areas where possible. 3) Sprinkler heads shall be as indicated on the drawings. Six inch (6) pop-up type spray heads shall be installed in all lawn areas. Twelve inch (12") pop-up type spray heads shall be installed in all ground cover/ shrub areas. 4) Irrigation system shall always be isolated from domestic system with use of an approved backflow device. 114,11111111 1111#011111111 T EXISTING STATIC PRESSURE (psi) : 85 COMPONENT SIZE GPM LENGTH LOSS/1 00'NET L L 'SS WATER METER 2" 40 — 130 COPPER SERVICE LINE 21 01 110 0.85 B.F.P. Y2 12.0 MAINLINE 31 2500' 0.17 4.25 CONTROL VALVE 1-X° — 2.70 ELEVATION 43-33 7.37 LATERALS 5.0 SUBTOTAL: 3147 25% PRESSURE ALLOWANCE FOR FITTINGS: 837 SPRINKLER OPERATING PRESSURE: 30.0 TOTAL PRESSURE LOSS (psi): 71.84 11 Irrigation Plan Scale: V=20' North Landscape Architecture Urban Design & Planning 181 N.'E'Street, Son Bernardino, CA 92401 phone: (909) 888-5568 fox: (909) 384-9854 e-mail: rpe.1c'4verizon.net Richard Pope, Landscape Architect CAff 2664 51qcp-t DC5r_ription: Date: July 26, 2004 Sheet: .0 CL TIME U. co r4ft cc Ci law E 51qcp-t DC5r_ription: Date: July 26, 2004 Sheet: