HomeMy WebLinkAbout3667-3i f _ CONTRACTOR TO CONFIRM
LOCATION OF CONTROLLER
GONTFZOLLEK 8
FRIG TION W51 1-055) VAWE-6 22 CPM
I" HATER METER
3.3
1-1/4"" BACKFLOW PREVENTER
12.50
ELEVATION CHANGES: -24'
-
LATERAL LINES
2.0
MAIN LINE (320 LF)
8.7
FITTING5 (20% OF MAIN LINE)
1.8
I" VALVE
.5
misc.
1.00
TOTAL F51 L055
29.8
HATER PRESSURE
80 P.S.I.
LESS TOTAL P51 L055
211.8
EOUALS
THE CONTRACTOR SHALL. FLU5H AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE
MINIMUM TO FARTHEST HEAD
50.2
SPRINKLER OPERATING PRE55URE
30.00
RESIDUAL HATER PRESSURE
20.2
P.
IRRIGATION SPECIFICATIONS
ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF FONTANA'S LANDSCAPE DEVELOPMENT
DESIGN INTENT 15 TO PROVIDE COMPLETE IRRIGATION COVERAGE TO ALL PLANTED AREAS, AS
STANDARD LAN05CAPE SPECIFICATION MANUAL FOR 5TREETSCAPES AND PARKS.
FIELD CHANGE MAY OCCUR, CONTRACTOR i3 REQUIRED TO PROVIDE 100% COVERAGE TO ALL
REVISION DESCR1PT10N
AREAS. IN NO INSTANCE SHALL HEAD 5PAGIN6 EXCEED 55% OF MANUFACTURER'5 RECOMMENDED
VERIFY ALL CONDITIONS AND DIMENS10N5 PRIOR TO COMMENDING ANY HORK, NOTIFY THE
SPACING FOR COVERAGE. CONTRACTOR SHALL NOT KNOWINGLY INSTALL A SPRINKLER SYSTEM
LAN05CAPE ARCHITECT IMMEDIATELY IF ANY DISCREPANCY 19 FOUND. CONTRACTOR SHALL
WITH IMPROPER COVERAGE, FAILURE TO NOTIFY THE LANDSCAPE ARCHITECT SHALL RESULT IN
THOROUGHLY FAMILIARIZE HIMSELF HITH ALL SITE CONDITIONS PRIOR TO BIDDING OR
THE CONTRACTOR REPAIRING/REPLACING SAID SYSTEM AT H15 OR MR EXPENSE.
COMMENGINC3 HORK.
ALL SPRINKLER HEADS INSTALLED ADJACENT TO CURS5 AND WALKS SHALL 13E POP-UP TYPE.
EXTREME CARE SHALL BE EXERCI5E0 WHEN WORKING ADJACENT TO ANY STRUCTURES OR
IN NO INSTANCE SHALL RISER TYPE SPRINKLERS BE INSTALLED ADJACENT TO PEDESTRIAN
UTILITIES. CONTRACTOR SHALL BE R-5PON515LE FOR LOCATING ALL EX15TIN6 UTILITIES AND
AREAS,
REPAIRING ANY DAMAGES CAUSED BY HIS HORK AT NO COST TO THE OWNER
THE CONTRACTOR SHALL. FLU5H AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE
IRRIGATION DESIGN IS BASED ON AN AVAILABLE HATER PRESSURE OF 75-80 P.S.I. WITH A
AND TO MINIMIZE OVERSPRAY ONTO WALKS, ROADWAY5 AND/OR BUILDINGS. THI5 SHALL
MAXIMUM SYSTEM DEMAND OF 34 G.P.M. CONTRACTOR SHALL VERIFY DATA AND, IF
INCLUDE 5ELEGTING THE BE5T DEGREE OF ARG TO FIT THE EXI5TING 51TE CONDITIONS AND
DIFFERENT, CONTACT LANDSCAPE ARCHITECT PRIOR TO COMMENCING WORK.
TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM PRESSURE FOR EACH
HATER AVAILABILITY INFORMATION HAS OBTAINED FROM FONTANA HATER COMPANY.
SYSTEM.
MAKE POINT OF CONNECTION AT THE HATER METER AS SHORN ON THE PLANS ANI7 RUN
ALL PIPING AND WIRING UNDER PAVING SHALL BE SLEEVED IN ASDH. 40 PVC PIPE, SIZE
A P.V.G. MAINLINE 18" DEEP TO AREAS WHERE VALVES ARE LOCATED. INSTALL A LINE
A5 REQUIRED AND WITH A MINIMUM COVER TO FINISHED PAVEMENT GRADE OF 24".
SIZED GATT: VALVE IN A ROUND PLASTIC BOX AT P.O.G. FOR EMERGENCY SHUT-OFF.
ALL EQUIPMENT SMALL. BE INSTALLED PER DETAILS, IN THE A135ENGE OF DETAILS,
THE LANDSCAPE ARCHITECT SHALL BE RESPONSIBLE FOR THE INTERPRETATION OF THE
INSTALLATION SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE TRADE.
ORAWIN65 SHOULD A QUESTION ARISE.
•
PIPINO SHOWN ON THE PLANS 15 E56ENTIALLY DIAGRAMMATIC, ROUTE PIPING AND LOCATE
CONTRACTOR SHALL GUARANTEE ALL MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR
VALVES TO AVOID CONFLICT WITH STATIONARY ELEMENTS. H -EN VERTICAL Q55TRUGTION5
FROM DATE OF FINAL ACCEPTANCE 15Y THE OWNER '
(FIRE HYDRANTS, LIGHTS, TREES ETC) INTERFERE WITH THE SPRAY PATTERN OF THE HEADS,
PROVIDE A COLOR CODED LAMINATED CONTROLLER CHART IN THE CONTROLLER 5POHIN65 THE
THE IRRIGATION CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM AT NO ADDITIONAL
VALVES AND AREAS SERVED BY EACH VALVE.
COST TO THE OWNER, BY INSTALLING A QUARTER OR HALF HEAD SPRINKLER ON EACH SIDE OF
THE OBSTRUCTION 50 AS TO PROVIDE PROPER COVERAGE. LOCATE ALL VALVES AND BACKFLOH
CHECKED BY:
STB
DEVICE IN SHRUB 13EM INHERE POSSIBLE.
BEFORE BEGINNING CONSTRUCTION, THE CONTRACTOR MUST OBTAIN ALL NECESSARY PERMITS
WIRING FROM THE CONTROLLER TO THE VALVES SHALL BE DIRECT BURIAL A.F.W., MINIMUM
FROM THE CITY.
14 6AU6E. PROVIDE CONTINUOUS SPARE WIRES TO VALVE(S) FURTHEST FROM THE
CONTROLLER. LOOP HIRE INTO EACH VALVE BOX ALONG THE MAINLINE WTH A MIN. 30"
THE 1RM6ATION SYSTEM HILL BE TESTED BY THE OHNERS REPRESENTATIVE 1N THE FIELD
EXPANSION COIL. SPARE HIRE 15 TO BE A DIFFERENT COLOR FROM OTHER CONTROL HIRES.
SORE FINAL APPROVAL.
LABEL HIRE SPARE IN CONTROLLER.
INSTALL ALL COMPONENTS PER CURRENT U.P.C. AND LOCAL CODE5.
PROVIDE CHECK VALVES AS NEEDED TO ELIMINATE ALL LOW HEAD DRAINAGE.
CONTRACTOR SHALL MAINTAIN A CLEAN AND SAFE WORKING ENVIRONMENT. DAY AND NIGHT
ALL EQUIPMENT SHALL BE AS LISTED IN THE LEGEND. SUBSTITUTIONS HILL NOT BE
BARRICADES MUST BE PROVIDED FOR ALL OPEN TRENCHES.
PERMITTED WTIHOUT PRIOR APPROVAL OF THE LANDSCAPE ARCHITECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE UNDERGROUND SERVICE ALERT
CONTRACTOR SHALL PROVIDE COMPLETE AND ACCURATE RECORD DRAHIN65 TO THE CITY UPON
AT I-800-422-4133 AT LEAST 48 HOURS PRIOR TO TRENCHING FOR EXACT UNDERGROUND
COMPLETION OF THE PROJECT. DRAWINGS SHALL INDICATE ANY CHANGES FROM THE ORIGINAL
UTILITY LOCATIONS. THE CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR THE REPAIR OR
PLANS AND DIMENSIONS OF VALVES, QUICK COUPLERS, CONTROLLERS AND ALL OTHER
REPLACEMENT OF UNDERGROUND UTILITIES OR STRUCTURES WHICH ARE DAMAGED DURING THE
EQUIPMENT FROM STATIONARY POINTS OF REFERENCE.
COURSE OF COMPL.ETINO THIS WORK.
REFER TO SHEET 2 FOR IRRIGATION LEGEND
REFER TO SHEET 6 FOR CONSTRUCTION DETAILS
- '
ASHOULD
R 01
DIAL TWO WORKING
BEFORE DAYS BEFORE
YOU DIG You DIG
TOLL FREE 1-8�0-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV:
REVISION DESCR1PT10N
DAIS
ENGR.
CITY
DATE
CONSTRUCTION OF THE REQUIRED IMPROVEMENTS
NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF
APPROVAL SHOWN HEREON AND CARRIED FORTH IN A
DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE
REVISIONS TO THE PLANS TO BRING THEM INTO
CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT.
�T.£ ��,
qn ti
�r'� (o 'y %'
,.
* *
s ° d°
T9 Or CALk� �\
STB
p c LANDSCAPE ARCHITECTS
?•�rr� IANDSCAPE
WMGATION CONsviTaM
15 South 5th Street
-. Redlands, California 92373
9CA�L e. No42725axM(909ie 3,07-8235
stblondarcli.com
CITY OF FONTANA, CALIFORNIA
TRACT NO. 16572 LMD AREAS
DRAWN BY:
CAD
IRRIGATION
N
SCALE:
1"=20'
DESIGNED BY:
CR
DATE:
9/2/04
CHECKED BY:
STB
0 a�
RARING NO.:3
3667
I ENGINEER R.C-F- 51152 DATE