HomeMy WebLinkAbout3584-1GENENOTES:
1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THESE PLANS` THE SPECIAL
PROVISIONS, THE CITY OF F()NTANA STANDARD PLANS AND SPECIFICATIONS, AND
THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 88 AND STANDARD
PLANS (DATED JULY 2002\.
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND 0G FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS
BEFORE DIGGING.
3. REUSE PULLBOXES AND CONDUIT UNLESS OTHERWISE SHOWN.
ALL VEHICLE HEADS SHALL BE PER SPECIAL PROVISIONS.
4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING
VNTM THE SOUTHERN CALIFORNIA E0SON COMPANY WELL IN ADVANCE OF NEED.
5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT
6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
R]NTANA ENGINEERING 0NS|0N PRIOR TO COMMENCEMENT OF WORK.
7. ALL VEHICLE HEADS SHALL BE 12" WITH BACKPLATES, SEE SPECIAL PROVISIONS.
EX. 1" [. YNTM 1 DLC
A CONDUCTOR TABLE
L
CIRCUIT OR
RUNS
LUMINAIRE
PED PUSH 13T.
SIGNAL MOUNTING
S. N. S.
PLACEMENT
REMARKS
AWG.
TYPE
M
POLE
LUM.
H.P.S,V.
TYPE
PHASE
QUAD
MAST ARM
VEHICLE
PIED,
MESSAGE
A
B
207'
POLE
POLE
1/1
1/1
1 CONDUIT SIZE
3)v
3)$
& ALL CONDUIT IS EXISTING. REMOVE ALL EXISTING
CONDUCTORS AND INSTALL NEW.
R/W
11 POLE SCHEDULE
L
STANDARD
MASTARMS
LUMINAIRE
PED PUSH 13T.
SIGNAL MOUNTING
S. N. S.
PLACEMENT
REMARKS
cl
TYPE
HT.
SIG.
LUM.
H.P.S,V.
TYPE
PHASE
QUAD
MAST ARM
VEHICLE
PIED,
MESSAGE
A
B
207'
TO
57' 36' SC LOOPS
R35 _R3
CL
02
08 co Q0 0111
R34 05; N
�/ r~r R34153 TO |_
T—WALK �q-
``
vv
m r ,
~ �
C/G 04 to
�
ED III
PHASE
DIAGRAM
NOT
USED
EX 1" C WITH
1 DLC
NOT
USED
NOT
USED
G-)
14'
15'
04P R4
SC LOOPS
CONSTRUCTION NOTES:
EXISTING TYPE 90 CONTROLLER IN TYPE P CABINET. INSTALL AUXILLARY EQUIPMENT AS
NECESSARY TO PROVIDE FOR THE OPERATIONS SHOWN.
F21 INSTALL CITY FURNISHED UNIDIRECTIONAL OPTICAL DETECTOR PER DETAILS SHOWN ON THIS
SHEET AND AS DIRECTED BY THE ENGINEER.
,
`
EX. 1° C, WITH 1 DLC
LEGEND:
UNI —DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR
Curb/Berm flow lir
or edge of shouldr,
,
AUTOCAD FILENAME: Slaver at Mulberry T5dwg
S:\traffic\Reggie\Plcns\0pticom Upgrades\Slover at Mulberry\Slover at Mulberry TS.dwgi
-
�
AVENUE
EX 1" C WITH
1 DLC
207'
TO
04P R4
SC LOOPS
CONSTRUCTION NOTES:
EXISTING TYPE 90 CONTROLLER IN TYPE P CABINET. INSTALL AUXILLARY EQUIPMENT AS
NECESSARY TO PROVIDE FOR THE OPERATIONS SHOWN.
F21 INSTALL CITY FURNISHED UNIDIRECTIONAL OPTICAL DETECTOR PER DETAILS SHOWN ON THIS
SHEET AND AS DIRECTED BY THE ENGINEER.
,
`
EX. 1° C, WITH 1 DLC
LEGEND:
UNI —DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR
Curb/Berm flow lir
or edge of shouldr,
,
AUTOCAD FILENAME: Slaver at Mulberry T5dwg
S:\traffic\Reggie\Plcns\0pticom Upgrades\Slover at Mulberry\Slover at Mulberry TS.dwgi
-
�