1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA
STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE
SPECIFICATIONS AND STANDARDS SHALL BE THE LA TEST EDITION
UNLESS OTHERWISE NOTED,
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT
CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN
BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY
ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVE—
LOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION
COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF
ANY WORK IN PUBLIC RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST
NON—METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY 7RAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES,
DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK
FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION
OF INDUSTRIAL SAFETY.
8 7HE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED BY SHORING„ SLOPING OF THE GROUND OR OTHER APPROVED MEANS
PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE
OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN
THE POTEN77AL EXISTS FOR GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT—OF—WAY WITHOUT
OBTAINING A SEPARA TE PERMIT FOR THA T PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING
UTILITIES, AND TO EXERCISE PROPER PRECAU77ON TO AVOID DAMAGE THERETO,
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600
TWO WORKING DAYS BEFORE EXCA VA TION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES
INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION,
LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER,
STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE
GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED,
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE
THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL
BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL
STAKING DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT
TIES OR BENCH MARKS W1 THOUT PRIOR NO77FICA TION TO THE CITY ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY
MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED
CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE
DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR
SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL
TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION
AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFEC77VE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL 77MES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS
TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT—OF—WAY
DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL,
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
27 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE
TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE—WORKING OF THAT PORTION
OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED,
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING
STREET IMPROVEMENTS. UPON INSPECT70N OF 77 -IE SITE, THE CITY ENGINEER MAY REQUIRE
TEMPORARY NON—ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE COLOR AND FINISH
TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCT70N IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE
A TERMINAL CLEANOUT AT THE PHASE BOUNDARY; NOT MORE THAN 150 FEET FROM THE
DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE
VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS
OF THE ASTM DESIGNA77ON 0700 FOR V.G.P..
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL
OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE
WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT.
28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND
VERIFY ELEVA77ON AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS
TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS
SHOWN ON THE PLANS.
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
3O TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12"
BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE
STREET RIGHT—OF—WAY THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS
MEASURED FROM THE UTILITY EASEMENT
31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE
LOCATION OF THE SEWER LATERAL,
32 IF EXISTING UTILITIES OR ANY OTHER FACIL177ES CONFLICT WITH THE PROPOSED
IMPROVEMENTS, THE CONTRACTOR SHALL N077FY THE ENGINEER AND ALL AFFECTED
AGENCIES IMMEDIA TEL Y.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN
PLACED, INSPECTED AND APPROVED.
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR
TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED
TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING
37 UPON COMPLE77ON OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING,
STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SA77SFAC77ON
OF THE CITY TRAFFIC ENGINEER.
38 AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
'.W40111111,
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8J5J SIERRA AVENUE
3939 E.CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350--6632
(714) 666-5467
SO. CALIFORNIA GAS COMPANY
COMCAST (GABLE TV)
ATTN. GREG GASPAR
ATTN: JACK HAYES
162(1 VALLEY BLVD.
1205 DUPONT AVENUE
FONTANA, CA. 92335
ONTARIO, CA, 91761
11
(909) 390 4736
EMERGENCIES: (800) 427-2200
FAX: (909) 82J--5045
GENERAL TELEPHONE COMPANY
SO. CALIFORNIA ED/SON COMPANY
ATTN: STEVE HOCK
7951 REDWOOD AVENUE
1400 E. PHILLIPS BLVD.
FONTANA, CA. 92JJ5
ONTARIO, CA. 91766
(909) 820-5598 UNDERGROUND
(800) 422-4133
(909) 875-5100 - TRANSMISSIONS
STORM DRAIN
(213) 637-1233 PIPELINES
FONTANA WATER COMPANY
(909) 357-6233 DISTRIBUTION
ATTV: MICHAEL J, McGRAW
(800) 422-4133
8440 NUEVO AVENUE
GRADINGASTM C 131
TEST
FONTANA, CA 92JJ5
CRAWFORD CANYON MUTUAL WATER CO.
(909) 822-2201
ATTN: BILL VANDERKIEFI JR.
FAX: (909) 82J--5045
(619) 868-6040
--k;
UNDERGROUND SERVICE ALERT
{ -�--
(800) 227-2600
--C--
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR
STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF
AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO
EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO
PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR
FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY
PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE
DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY: THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS. AND THAT THE CONTRACTOR SHALL DEFEND,
INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY
AND ALL LIABILITY REAL OR ALLEGED IN CONNECTION WITH THE
PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY
ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL
REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE
COMMENCEMENT OF WORK
6" MIN.
10" MAX,
5" MAX. SIZE---
NA TI VE SOIL
COMPA C TED 05,
6" MAX. SIZE —
NA TI VE SOIL
COMPACTED 90..
VC,P./D.L
i � ° v
!�u��I\II
i
VARIES 6" MIN.
I I 1 10" MAX.
I" MAX. SIVE
SEL EC TED NA Tl VE
BEDDING COMPA C TED
TO 9071:
10' OR DEEPER USE 112 " -----
CRUSHED STONE BEDDING
PER S TD. SPECS. FOR
PUBLIC WORKS CONSTRUCTION
TABLE 200 1.2 [A]
TYPICAL BEDDINGDETAIL
NOT TO SCALE
2
22�.
23
1 24
.CONSTRUCTION NOTES:
0- INSTALL 8" EXTRA STRENGTH V C. P. SEWER.
20- CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF_
FONTANA STD. DWG. NO. 112 (0=48").
0-- INSTALL 4" EXTRA STRENGTH V. G. P. SEWER LATERAL PER
CITY OF FONTANA STD. DWG. NO. 125.
REV. REVISION DESCRIPTION DATE ENGR. CITY DATE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL SHOWN HEREON AND
�--
CARRIED FORTH IN A DILIGENT MANNER, THE CITY
ENGINEER MAY REQUIRE REVISIONS TO THE PLANS T
RING THEM INTO CONFORMANCE WITH CONDITIONS
AND STANDARDS IN EFFECT®
lT
1,112 L.F.
5 EA.
220 L.F.% 11 EA.
ortvun warm; No. 615
RAILROAD SPIKE AT INTERSECTION
OF CITRUS AVE. AND LOS CEDROS
AVE., IN POWER POLE NO, 9011 E
ON THE EAST SIDE OF CITRUS AVE.
ELEVATION. 1467.59
Je su,, "'Lt�\
SEWER LA TERAL
- - - -
SEWER
c No. 65195 o
WA TER
- - --S-D - -
STORM DRAIN
- - --T---- - -
TELEPHONE
- -- -
'
IINIIIIIIII/���
r
GRADINGASTM C 131
TEST
WATER MAIN
6" MIN.
10" MAX,
5" MAX. SIZE---
NA TI VE SOIL
COMPA C TED 05,
6" MAX. SIZE —
NA TI VE SOIL
COMPACTED 90..
VC,P./D.L
i � ° v
!�u��I\II
i
VARIES 6" MIN.
I I 1 10" MAX.
I" MAX. SIVE
SEL EC TED NA Tl VE
BEDDING COMPA C TED
TO 9071:
10' OR DEEPER USE 112 " -----
CRUSHED STONE BEDDING
PER S TD. SPECS. FOR
PUBLIC WORKS CONSTRUCTION
TABLE 200 1.2 [A]
TYPICAL BEDDINGDETAIL
NOT TO SCALE
2
22�.
23
1 24
.CONSTRUCTION NOTES:
0- INSTALL 8" EXTRA STRENGTH V C. P. SEWER.
20- CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF_
FONTANA STD. DWG. NO. 112 (0=48").
0-- INSTALL 4" EXTRA STRENGTH V. G. P. SEWER LATERAL PER
CITY OF FONTANA STD. DWG. NO. 125.
REV. REVISION DESCRIPTION DATE ENGR. CITY DATE
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS
OF THE DATE OF APPROVAL SHOWN HEREON AND
�--
CARRIED FORTH IN A DILIGENT MANNER, THE CITY
ENGINEER MAY REQUIRE REVISIONS TO THE PLANS T
RING THEM INTO CONFORMANCE WITH CONDITIONS
AND STANDARDS IN EFFECT®
lT
1,112 L.F.
5 EA.
220 L.F.% 11 EA.
ortvun warm; No. 615
RAILROAD SPIKE AT INTERSECTION
OF CITRUS AVE. AND LOS CEDROS
AVE., IN POWER POLE NO, 9011 E
ON THE EAST SIDE OF CITRUS AVE.
ELEVATION. 1467.59
CIV t�
CAU\
CINITY MAP
NOT TO SCALE
Je su,, "'Lt�\
SEWER LA TERAL
- - - -
SEWER
c No. 65195 o
WA TER
- - --S-D - -
CIV t�
CAU\
CINITY MAP
NOT TO SCALE
THE BEARING OF NOO` 12'36'E ALONG
THE CENTERLINE OF CATAWBA AVENUE
4S SHOWN ON RECORD OF SURVEY,
FILED IN BOOK 10.3, PAGES 1 AND 2,
OF RECORDS OF .SURVEY ; WAS USED
4S THE BASIS OF BEARINGS FOR THIS
Prepared Under The Supervision Of :
PREPARED IN THE OFFICE O
MADOLE AND ASSOCIATES,
10601 CHURCH
RANCHO CUCAMONGA, CA 91730
PHONE * 948-1311
RCE 65195
m
J:\826-1739\sewer\sewCatawba0l .dwg, 03/25/2004 04:03:07 Pm, cc
SERVER MAIN
SEWER LA TERAL
- - - -
SEWER
- - -W- - -
WA TER
- - --S-D - -
STORM DRAIN
- - --T---- - -
TELEPHONE
- -- -
ELECTRIC
- -- - -
GAS
WATER MAIN
--
FIRE HYDRANT
s—
POST INDICA TOR VAI_ VE
--k;
FIRE DEPT. CONNECTION
{ -�--
GA TE VALVE
--C--
BACK FLOW PREVEN TOR
--- -{----
METER
-- ----
MANHOLE
CLEAN OUT
H
THE BEARING OF NOO` 12'36'E ALONG
THE CENTERLINE OF CATAWBA AVENUE
4S SHOWN ON RECORD OF SURVEY,
FILED IN BOOK 10.3, PAGES 1 AND 2,
OF RECORDS OF .SURVEY ; WAS USED
4S THE BASIS OF BEARINGS FOR THIS
Prepared Under The Supervision Of :
PREPARED IN THE OFFICE O
MADOLE AND ASSOCIATES,
10601 CHURCH
RANCHO CUCAMONGA, CA 91730
PHONE * 948-1311
RCE 65195
m
J:\826-1739\sewer\sewCatawba0l .dwg, 03/25/2004 04:03:07 Pm, cc