HomeMy WebLinkAbout3582-1GENERAL SEWER T w 1 ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LA TEST EDITION UNLESS OTHERWISE NOTED, 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVE— LOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON—METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY 7RAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8 7HE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING„ SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTEN77AL EXISTS FOR GROUND MOVEMENT. 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT—OF—WAY WITHOUT OBTAINING A SEPARA TE PERMIT FOR THA T PURPOSE. 10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAU77ON TO AVOID DAMAGE THERETO, THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCA VA TION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED, 14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS W1 THOUT PRIOR NO77FICA TION TO THE CITY ENGINEER. 16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFEC77VE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL 77MES. 19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT—OF—WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL, 20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 27 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE—WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED, 22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECT70N OF 77 -IE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON—ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS 23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24 IF SEWER CONSTRUCT70N IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY; NOT MORE THAN 150 FEET FROM THE DOWN STREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. 25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNA77ON 0700 FOR V.G.P.. 26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVA77ON AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 3O TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT—OF—WAY THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT 31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL, 32 IF EXISTING UTILITIES OR ANY OTHER FACIL177ES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL N077FY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIA TEL Y. 33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT 36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING 37 UPON COMPLE77ON OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SA77SFAC77ON OF THE CITY TRAFFIC ENGINEER. 38 AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. '.W40111111, CITY OF FONTANA PACIFIC BELL CO. ATTN: CARLOS NAVARRO ATTN: VIRGINIA BECKER 8J5J SIERRA AVENUE 3939 E.CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350--6632 (714) 666-5467 SO. CALIFORNIA GAS COMPANY COMCAST (GABLE TV) ATTN. GREG GASPAR ATTN: JACK HAYES 162(1 VALLEY BLVD. 1205 DUPONT AVENUE FONTANA, CA. 92335 ONTARIO, CA, 91761 11 (909) 390 4736 EMERGENCIES: (800) 427-2200 FAX: (909) 82J--5045 GENERAL TELEPHONE COMPANY SO. CALIFORNIA ED/SON COMPANY ATTN: STEVE HOCK 7951 REDWOOD AVENUE 1400 E. PHILLIPS BLVD. FONTANA, CA. 92JJ5 ONTARIO, CA. 91766 (909) 820-5598 UNDERGROUND (800) 422-4133 (909) 875-5100 - TRANSMISSIONS STORM DRAIN (213) 637-1233 PIPELINES FONTANA WATER COMPANY (909) 357-6233 DISTRIBUTION ATTV: MICHAEL J, McGRAW (800) 422-4133 8440 NUEVO AVENUE GRADINGASTM C 131 TEST FONTANA, CA 92JJ5 CRAWFORD CANYON MUTUAL WATER CO. (909) 822-2201 ATTN: BILL VANDERKIEFI JR. FAX: (909) 82J--5045 (619) 868-6040 --k; UNDERGROUND SERVICE ALERT { -�-- (800) 227-2600 --C-- THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY REAL OR ALLEGED IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK 6" MIN. 10" MAX, 5" MAX. SIZE--- NA TI VE SOIL COMPA C TED 05, 6" MAX. SIZE — NA TI VE SOIL COMPACTED 90.. VC,P./D.L i � ° v !�u��I\II i VARIES 6" MIN. I I 1 10" MAX. I" MAX. SIVE SEL EC TED NA Tl VE BEDDING COMPA C TED TO 9071: 10' OR DEEPER USE 112 " ----- CRUSHED STONE BEDDING PER S TD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A] TYPICAL BEDDINGDETAIL NOT TO SCALE 2 22�. 23 1 24 .CONSTRUCTION NOTES: 0- INSTALL 8" EXTRA STRENGTH V C. P. SEWER. 20- CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF_ FONTANA STD. DWG. NO. 112 (0=48"). 0-- INSTALL 4" EXTRA STRENGTH V. G. P. SEWER LATERAL PER CITY OF FONTANA STD. DWG. NO. 125. REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND �-- CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS T RING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT® lT 1,112 L.F. 5 EA. 220 L.F.% 11 EA. ortvun warm; No. 615 RAILROAD SPIKE AT INTERSECTION OF CITRUS AVE. AND LOS CEDROS AVE., IN POWER POLE NO, 9011 E ON THE EAST SIDE OF CITRUS AVE. ELEVATION. 1467.59 Je su,, "'Lt�\ SEWER LA TERAL - - - - SEWER c No. 65195 o WA TER - - --S-D - - STORM DRAIN - - --T---- - - TELEPHONE - -- - ' IINIIIIIIII/��� r GRADINGASTM C 131 TEST WATER MAIN 6" MIN. 10" MAX, 5" MAX. SIZE--- NA TI VE SOIL COMPA C TED 05, 6" MAX. SIZE — NA TI VE SOIL COMPACTED 90.. VC,P./D.L i � ° v !�u��I\II i VARIES 6" MIN. I I 1 10" MAX. I" MAX. SIVE SEL EC TED NA Tl VE BEDDING COMPA C TED TO 9071: 10' OR DEEPER USE 112 " ----- CRUSHED STONE BEDDING PER S TD. SPECS. FOR PUBLIC WORKS CONSTRUCTION TABLE 200 1.2 [A] TYPICAL BEDDINGDETAIL NOT TO SCALE 2 22�. 23 1 24 .CONSTRUCTION NOTES: 0- INSTALL 8" EXTRA STRENGTH V C. P. SEWER. 20- CONSTRUCT PRECAST CONCRETE MANHOLE PER CITY OF_ FONTANA STD. DWG. NO. 112 (0=48"). 0-- INSTALL 4" EXTRA STRENGTH V. G. P. SEWER LATERAL PER CITY OF FONTANA STD. DWG. NO. 125. REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND �-- CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS T RING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT® lT 1,112 L.F. 5 EA. 220 L.F.% 11 EA. ortvun warm; No. 615 RAILROAD SPIKE AT INTERSECTION OF CITRUS AVE. AND LOS CEDROS AVE., IN POWER POLE NO, 9011 E ON THE EAST SIDE OF CITRUS AVE. ELEVATION. 1467.59 CIV t� CAU\ CINITY MAP NOT TO SCALE Je su,, "'Lt�\ SEWER LA TERAL - - - - SEWER c No. 65195 o WA TER - - --S-D - - CIV t� CAU\ CINITY MAP NOT TO SCALE THE BEARING OF NOO` 12'36'E ALONG THE CENTERLINE OF CATAWBA AVENUE 4S SHOWN ON RECORD OF SURVEY, FILED IN BOOK 10.3, PAGES 1 AND 2, OF RECORDS OF .SURVEY ; WAS USED 4S THE BASIS OF BEARINGS FOR THIS Prepared Under The Supervision Of : PREPARED IN THE OFFICE O MADOLE AND ASSOCIATES, 10601 CHURCH RANCHO CUCAMONGA, CA 91730 PHONE * 948-1311 RCE 65195 m J:\826-1739\sewer\sewCatawba0l .dwg, 03/25/2004 04:03:07 Pm, cc SERVER MAIN SEWER LA TERAL - - - - SEWER - - -W- - - WA TER - - --S-D - - STORM DRAIN - - --T---- - - TELEPHONE - -- - ELECTRIC - -- - - GAS WATER MAIN -- FIRE HYDRANT s— POST INDICA TOR VAI_ VE --k; FIRE DEPT. CONNECTION { -�-- GA TE VALVE --C-- BACK FLOW PREVEN TOR --- -{---- METER -- ---- MANHOLE CLEAN OUT H THE BEARING OF NOO` 12'36'E ALONG THE CENTERLINE OF CATAWBA AVENUE 4S SHOWN ON RECORD OF SURVEY, FILED IN BOOK 10.3, PAGES 1 AND 2, OF RECORDS OF .SURVEY ; WAS USED 4S THE BASIS OF BEARINGS FOR THIS Prepared Under The Supervision Of : PREPARED IN THE OFFICE O MADOLE AND ASSOCIATES, 10601 CHURCH RANCHO CUCAMONGA, CA 91730 PHONE * 948-1311 RCE 65195 m J:\826-1739\sewer\sewCatawba0l .dwg, 03/25/2004 04:03:07 Pm, cc