MIN. FROM HARDSCAPES
61, MIN.
NON -PRESSURE LATERAL LINE
LATERAL LINE
PRESSURE SUPPLY LINE
CONTROL WIRES
LEAN BACKFILL
FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES, NO
LARGER THAN 1/2" IN SIZE. THIS WILL BE PERMITTED IN THE
INITIAL BACKFILL MEASURED FROM THE TOP OF PIPE. THE REMAINDER
OF TRENCH CAN BE FILLED WITH ROCK SCREENED 2" MINUS.
ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90%.
INSTALL ALL PVC PIPE WITH LABEL UP.
SNAKE ALL PIPES IN TRENCH.
BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE
SUPPLY LINE AND PROVIDE A SERVICE LOOP AT ALL 90 dEGREE
CHANGES IN DIRECTION.
PRESSURE MAIN LARGER THAN 2" SHALL BE P.V.C. CLASS 315
SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40.
CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT LINES WHEN
MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE.
CONTRACTOR SHALL PROVIDE 24" OF COVER OVER PIPE
SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE
3" AND LARGER.
-11=11 If I I I i- ��•'FIX� ii'�!�
II 11 �I I g,iggsi,���a%,4
11_II_91
�t,�ti�QQi�i�Qt�r:�7J1r`
n -I li • - •
ulr�li�•11=,1 ,
n=n=n=-:r�—n=nn-nor
NOTES:
INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE,
SIZE PER SPEC.
ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE
LINE TO BE SLEEVED.
* INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND
COMMERCIAL TRAFFIC WAYS.
SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS
REQUESTED BY INSPECTOR
IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE
ENDS AND PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE ON
GROUND LEVEL.
SLEEVING DETAIL
MAIN SUPPLY,
LATERAL N D
WIRING MAIN SUPPLY LATERAL 120 VOLT CONTROL WIRING
':LsJ
' � • LATERAD
WIRING MAINLIN a
ELEVATION VIEW
PROVIDE A 20" LOOP
OF WIRE IN ALL
M
CHANGES OF
ALL MAINLINE INSTALL ALL 120 DIRECTION GREATER
SHALL BE VOLT WIRE IN THAN 30 DEGREES
INSTALLED PER CONDUIT PER LOCAL REMOVE TIES AFTER
MFG'S ALL CONNETIONS
'' CODE
SPECIFICATIONS' HAVE BEEN MADE
TAPE AND SNAKE ALL PLASTIC PIPE
BUNDLE WIRING INTO TRENCHES AS
AT 10' O.C. SHOWN
MAXIMUM TO PLAN VIEW
MAINLAINE.
NOTE:
DO NOT INSTALL 120 VOLTAGE OR HIGHER WIRE
IN THE SAME TRENCH AS THE IRRIGATION
CONTROL WIRING
POP-UP SHRUB HEAD
FINISH GRADE
LL
SCH 80 PVC NIPPLE
THREADED BOTH ENDS
BOXTO BE PLACED AT RIGHT ANGLE T
HARDSCAPE EDGE w/ VALVE # ETCHED IN LID
12"X18" PLASTIC BOX AND COVER WIT
LOCK TOP
CURL TYPE EXPANSION LOOP (MIN.24"
WATERPROOF WIRE CONNECTION
IZ "OR HARDSCAPE
CHRISTY'S I.D TAG (STANDARD) Ab NOTEa
SECURE TO SOLENOID PIGTAIL
FINISH GRAD
d..
11=
12 "MAX. TOP I D 1211
OP VALME
PVC LINE PIPE 11
ON -
10" MIN �T— INE FITTINGURE
UNION CONNECTION
PEA GRAVEL
(MIN_3 CU. FT.)
PVC LINE PIPE PVC SCH. 40 MALE ADAPTOR
PVC ELBOW (TYP. 2 PLACES)
PVC LINE PIPE
COMMON WIR PVC SUPPLY LINE FITTINGS(SXSXS)
CONTROL WIRE)
NOTES:
1. VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE NOTED
2. WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAME AREA. PROVIDE A SPACE A MIN. OF
3 FT. APART.
3. USE TEFLON TAPE ON ALL THREADED FITTINGS.
4. ONE VALVE PER VALVE BOX
TYP. BRASS REMOTE CONTROL VALVE
WALK OR CURB
�• 10" VALVE BOX MARKED W/ 2" QUICK COUPLER VALVE
ill LETTERS READING Q.C. 12" MIN. FROM HARDSCAPE MATERIALS
FINISH GRADE
a �
= I =1 I L=7W=7111=1 11=1 11=1 11=1 11- 1-I I I--
° • . ' A. . a I 1=III=1 I I=L=1 I L=III-III-III-I 11=III=1 I I -III -I I III -I 11=1 11=111 -IIIA -I 11=1 I 1=1 I I III III=
-� 1=1 I= -I I IH I ILI=1 I IEiILI =111-111= 11=1 11= I I I -I I -I 11=111=11-1 I I -III LII -1 11=11 I I I -I
11=1 11=11=111a 11-1 I I I 1 1=111=111-111=11 I III 111 11 111:
6" MIN PEA GRAVEL 1= J
�—� 2 x 4 RWD OR BRICK
BRASS STREET ELL TYP.
S�Z.�RASS NIPPLE 6" MIN
PVC SHC 40 TEE OR ELL
PVC STREET ELLS LATERAL LINE SIZE TO BE NOTED ON PLAN
24" MIN. #4 REBAR, ATTACH
W/(2) STAINLESS STEEL BANDS
NOTE:
O INSTALL 12" SHRUB POP-UP HEAD 1 1/2"
1N GROUNDCOVER/MULCH, 3/4" TO 1- IN TURF,
ABOVE F.G.
O F.G. - 1 1/2" BELOW WALK OR CURB
Iii 1 9 a I lilf i
'�
FINISH GF'^nr
SCH 80 PVC NIPPLE —
THREADED BOTH ENDS
WALK OR CURB
b"
MARLEX STREET ELL
PVC LATERAL LINE
NOTE:
0 ALL BUBBLERS TO BE INSTALLED
WITH TRIPLE SWING JOINTS
O F.G. - 1 1/2" BELOW WALK OR CURB
FINISH GRADE
RISER
MAIN OR LATERAL LINE
TEE OR ELL
12" NIPPLE
TEE OR ELL
— — — — — MAIN OR LATERAL LINE
MARLEX STREET ELL(PRIVATE)
PVC STREET ELL(PUBLIC)
12" NIPPLE
PLAN
MARLEX STREET ELL(PRIVATE)
PVC STREET ELL(PUBUC)
SCHEDULE 40 STREET ELL
SCHEDULE 80 PVC RISER
NOTE: ALL PIPE AND FITTINGS SHALL BE SCHEDULE 40 &
80 PVC UNLESS OTHERWISE SPECIFIED
USE PVC STREET ELLS W/TEFLON TAPE FOR ALL
PUBLIC JOBS
SWING JOINT
NOTE:
USE TEFLON TAPE ON ALL THREADED FITTINGS
CONC. WALK 1 1/2°
OR CURB
FINISH GRADE
!. •• + • I I( III I—I I 1=11 11 I I 1 I
• ' >7• HI POP SHRUB HEAD
PVC STREET ELL
LATERAL LINE WITH
PVC TEE OR ELL
DOUBLE SWING JOINT
2 EA. PVC STEET ELLS
NOTE:
INSTALL HI -POP IRR. HEAD 1 1/2" ABOVE F.G.
F.G. 1 1/2" BELOW HARDSCAPE
VALVE BOX W/ LOCK
FINISH GRADE -,
IIIIIIIIIIIIIIIfiIIICI
WATERPROOF ALL
WIRE CONNECTIONS
AS PER STD.
RED
BLACK
GATE VALVE
PVC MALE ADAPTOR
1 CU. FT. PEA GRAVEL
MAINLINE
2" X 4" RWD. BLOCK
GATE VALVE
OF 14
WHITE WIRES
(COMMON)
BLUE
FLOW SENSOR
DIAMETER SAME SIZE
AS FLOW METER SIZE
MINIMUM DISTANCE UPSTREAM
1OX DIAMETER OF FLOW
METER SIZE
MASTER CONTROL
VALVE
MINIMUM DISTANCE DOWNSTREAM
5X DIAMETER OF FLOW METER SIZE
1 Rio C1 ita
♦I If `s, ►nlllult.IIIIIIIILI � �ni11� 111111►111,
not
I low
PRESSURE SUPPLY -tONC. STABILIZER FRONT PRESSURE
LINE (INTAKE) (TRUST BLOCK) LINE
(DISCHARGE)
REDUCE
PRESSURE BACKFLOW
3/4" GRAVEL
toll
NIP LE
(4 PLACES
- BRASS
ELBOW
-BRASS
UNION
-BRASS
PIPE
-BRASS
BALL
VALVE
r�
I�
•
�C
CIS
1
t2"
PLAN
WO
NOTE: BACKFLOW
ENCLOSURE,LE MEUR
00
OR EQUAL
24"X60"X36" HIGH
HINGED AT
ONE END SECURE
TO 6"X8"
FOOTING W/4" J
BOLTS (EQUIPMENT TO BE
WQ
CENTERED
INSIDE HOUSING)
REDUCE
PRESSURE BACKFLOW
PREVENT
-BRASS
NIP LE
(4 PLACES
- BRASS
ELBOW
-BRASS
UNION
-BRASS
PIPE
-BRASS
BALL
VALVE
LOCK BOX
(ACKFLOW ENCLOSURE
SEE NOTE BELOW
BRASS ELBOW
-BRASS UNION
BRASS BALL
VALVE
-#4 REBAR
GENERAL NOTES:
1. CONTRACTOR SHALL FORM ENCLOSURE AND REQUEST INSPECTOR
PRIOR TO POURING ENCLOSURE
2. CONTRACTOR SHALL USE 520-C-2500 CONCRETE
111 VAS I I 4_;j1fAj11 11111k I I "It
etl�,N%DSC.4 CITY OF FONTANA
278 y% LANDSCAPE PLANS
W"""'0 SULD
SIERRA LAKES PAI&KWAY / S SHOWN
Muslim �Q
we MEDIAN ISL S
tp�91Fy �0� MEMO= 301wrsw� »n � w+
OFCA�-� �►,� 9
i ��._V 3570 21
II T e C A P IC
Landscape Architecture
and Planning
3195-8 Airport Loop Dr.,
Costa Mesa, CA. 92626
Richard Palhamus. IJasnse CA—#2782
(949) 6"-9370 (714) 210-3140 FAX
Dvm CHK
DATE 06/04/03
JO'3 * 02-035
L8
of 25
V1
00
r�
I�
•
�C
CIS
1
WO
.,..,
00
dN
WQ
O-z:s�
M--oll
Q
Z
cis
z
�10
I.
Dvm CHK
DATE 06/04/03
JO'3 * 02-035
L8
of 25