Loading...
HomeMy WebLinkAbout3570-14e �D ;� I SIERRA LAKES PARKWAY 23 I 24 (-+ E-1 �I I I I I I I 11 I r NOTE: CONTRACTOR TO PULL (2) LABELD COMMON WIRES AND ALL REMAINING CONTROLL WIRE STATION D15 -1323 (LABLED) TO THIS LOCATION. LOCATE IN A LABELED VALVE BOX(S) WITH WITH A 36" LOOP FOR ALL WIRES 3�+i9 f 1�1t UST,A DRIVE 3l cc u COMMERCIAL SITE N'. C. E NOTE: 3 CONTRACTOR TO PULL (2) LABELD `COMMON WIRES Qr AND ALL REMAINING CONTROLL WIRE STATION i D24 -D32 (LABLED) TO THIS LOCATION. ` ` ,t LOCATE IN A LABELED VALVE BOX(S) WITH WITH A 36" OR ALL WIRES POINT OF CONNECTION: 'C' & 'D' 2" WATER METER, REFER TO CIVIL PLANS. CONTRACTOR TO INSTALL A 2" FEBCO 825Y REDUCED PRESSURE TYPE BACKFLOW PREVENTER AND LOCATE IN A LEMEUR VANDAL - RESISTANT STEEL MESH ENCLOSURE. COORDINATE LOCATION WITH CITY INSPECTOR. (SCREEN WITH SHRUBS) STATIC PRESSURE: 92.4 PSI DESIGN PRESSURE: 68.4 PSI MAXIMUM DEMAND: 65 GPM CONTROLLER: 'C' &_ 'D' _(STREETSCAPE) CONTRACTOR TO INSTALL (2) TORO NETWORK 8000 FIELD SATELLITE CONTROLLERS. CONTROLLERS TO BE MUST INCLUDE A RADIO CONTROL AND PHONE MODEM. COORDINATE LOCATION WITH CITY INSPECTOR. LOCATE CONTROLLER 'C'IN A STRONG BOX (SB-24SS-120V) AND CONTROLLER'D' IN A STRONG BOX (SB-24SS) (VERIFY WITH FIELD INSPECTOR PRIOR TO PURCHASE OR INSTALLATION) ENCLOSURE. SEE SITE ELECTRICAL PLANS. 'L P.O.C. , - ____ r \ ` I RR f C AT I ON LEC END M F M SYMBOL MFG. MODEL NO. DESCRIPTON RAD. GPM PSI SYMBOL MFG. MODEL NO. DESCRIPTION RAD. GPM PSI N TORO 570 Z-PRX-12P-COM-80 QUARTER SPRAY HEAD 8' .25 30 FM_j 2" DOMESTIC WATER METER - REFER TO CIVIL PLANS. ® TORO 570 Z-PRX-12P-COM-8H HALF SPRAY HEAD 8` .50 30 TORO 570 Z-PRX-12P-COM-8F FULL SPRAY HEAD 8' 1.0 30 FEBCO 825Y 2" REDUCED PRESSURE BACKFLOW PREVENTER IN LEMUR VANDAL- ' i 0 / (� TORO 570 Z-PRX-12P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 RESISTANT STEEL MESH ENCLOSURE - SEE DETAILS ® TORO 570 Z-PRX-I2P-COM-12H HALF SPRAY HEAD 12' 1.09 30 NIBCO T-113 GATE VALVE (3" OR SMALLER) - LINE SIZE TORO 570 Z-PRX-12P.COM-12F FULL SPRAY HEAD 12' 2.19 30 /IlLocate in a 10" round lockable plastic valve box. ® / SUPERIOR 590DW SERIES REMOTE CONTROL VALVE SIZE INDICATED / IU TORO 570 Z-PRX-12P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 ( ) / 0 TORO 570 Z-PRX-12P-COM-15H HALF SPRAY HEAD 15' 1.65 30 Locate in a 12" x18"rectangular lockable plastic valve box per valve. " @ TORO 570 Z-PRX-12P-COM-15F FULL SPRAY HEAD 15' 3.60 30 All valves and plastic valve boxes to be numbered. / ID TORO 570Z-PRX-12P-COM-2SST STRIP SPRAY HEAD 2X6' .09 30 & GRISWOLD 2230 MASTER VALVE / PRESSURE REGULATOR 21/2". (NORMALLY CLOSED) / 13 TORO 570Z-PRX-12P-COM-4EST END SPRAY HEAD 4X15' .45 30 O 11/2" DATA INDUSTRIAL MODEL 228 PV "IR" FLOW SENSOR / TORO 570Z-PRX-12P-COM-4SST STRIP SPRAY HEAD 4X30' .90 30 F TORO 570 Z-PRX-6P-COM-8Q QUARTER SPRAY HEAD 8' .25 30 Q0 RAINBIRD QUICK COUPLER 33D - Locate in a 10" round lockable plastic valve box If / ® TORO 570 Z-PRX-6P-COM-8H HALF SPRAY HEAD 8' .50 30 @ 150' o.c. maximum. Support with a sch 40 pvc pipe stake and two house clamps TORO 570 Z-PRX-6P-COM-8F FULL SPRAY HEAD 8' 1.0 30 each. \ C i d► 'y` TORO 570 Z-PRX-6P-COM-12Q QUARTER SPRAY HEAD 12' .50 30 //''�� AUTOMATIC CONTROLLER LOCATION (SEE CONTROLLER ENCLOSURE DETAIL). 21t" , ® TORO 570 Z-PRX-6P-COM-12H HALF SPRAY HEAD 12' 1.09 30 V \` / @TORO 570 Z-PRX-6P-COM-12F FULL SPRAY HEAD 12' 2.19 30 Provide controller charts per City requirements. / / TORO 570 Z-PRX-6P-COM-15Q QUARTER SPRAY HEAD 15' .85 30 Contractor to also instal a Rainguard moisture sensor @ the controller. Locate TORO 570 Z-PRX-6P-COM-15H HALF SPRAY HEAD 15' 1.65 30 in a vandal resistant area free from overhead obstruction and outside of the TORO 570 Z-PRX-6P-COM-15F FULL SPRAY HEAD 15' 3.6 30 irrigation spray pattern. � v t% 31 t�" /447 / ® TORO 570 Z-PRX-6P-SB-2-180-PC2 STREAM BUBBLER 2X6' .09 30 PVC SCN. 40 MAINLINE -1-1/2" AND SMALLER. PVC CLASS 315,2- AND LARGER. 570 Z-PRX-6P-SB-90-PC2 24" COVER UNDER PAVING, 18" COVER IN PLANTING AREAS, SIZES AS INDICATED. \ t (CONTRACTOR TO DECIDE IN FIELD WHICH BUBBLER TO INSTALL) jft CONTRACTOR MUST USE TORO 570 ADJUSTABLE ARC NOZZLES OR 570 V-15 PVC CLASS 200 LATERAL LINE -12" COVER IN PLANTING AREAS. t , 25\ / NOZZLES TO AVOID OVERSPRAY AND INSURE FULL COVERAGE. PVC SCHED. 40- 24" COVER UNDER PAVING IV �1 wIt THE CONTRACTOR MAY USE STANDARD RISERS IN SHRUB AREAS THAT ARE _ PVC SCH 40 MAIN AND LATERAL LINE SLEEVE 2x DIAMETER OF PIPE ADJACENT TO WALLS OR BUILDINGS OR WHERE PEDESTRIAN TRAFFIC WILL NOT Pipe, controller wires and communication cable to be 24" deep under paving and t 3 Z \ \ " ® OCCUR. 18" below walls. THE CONTRACTOR IS REQUIRED TO USE 570Z -COM (CHECK-O-MATIC) \ \ \ I POP-UP BODY'S ON ANY HEADS ON A SYSTEM WITH TOR GREATER THAN — — — SCH. 40 WIRE SLEEVE -Locate in a separate trench per UBC and City Specifications. \ ` " '� ELEVATION CHANGE- OR AS NEEDED IN FIELD. INDICATES VALVE NUMBER \ � \ \ N,4 " " THE 8 SPRAY HEADS MAY BE SUBSTITUTED WITH 10 NOZZLES AS REQUIRED IN INDICATES CONTROLLER o INDICATES VALVE GPM THE FIELD. ANY HEADS THAT NEED A REDUCTION OF MORE THAN 50 % OF THE 3"4 LISTED SPRAY PATTERN WILL REQUIRE TORO PCD SCREENS. INDICATES VALVE SIZE 4 SEE SHEET L-7 & L-8 FOR IRRIGATION DETAILS. NOTES & LEGEND 71 ®� \ ® �4w 34 T ® 1 ? 34 ZVw \ SHEE 5731 4 ' //� :mss f •' ."'ter �II��I��'���✓� � ,� �� �A� r Am 11i. Roy a27824AW ell ac SCALE 9lF �F CA���`�� ■ S I T 11: j C A P[ S Landscape Architecture and Planning 3195—B Airport Loop Dr., Costo Mom, CA. 92626 Richard Polhamus, License CA—#2782 (919) 64-9370 (714) 210-3140 FAX Q z o O u� 1 ' r W Z con �a U o >.4W N 002 � a N:t 0 `� M � a Un U Z pC) z iti-4 Wo Pit., Z H �w � o W Un ®VM CW DATE 06/04/03 JOB* 02-035 of 25 W >� •C •� d1 O O o zz ®VM CW DATE 06/04/03 JOB* 02-035 of 25