HomeMy WebLinkAbout3564-1PHASE DIAGRAM
kW P" A
'rOACC19% 010%-UAN 0%-Mffdl=OAI
1 TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA
STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002).
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE, THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO WORKING DAYS
BEFORE: DIGGING,
3. ALL TRAFFIC SIGNAL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID
METAL UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE
BROOKS TYPE P48 WITH EXTENSIONS (OR APPROVED EQUAL), PER SPECIAL PROVISIONS.
INTERCONNECT PULLBOX LIDS SHALL BE LABELED "COMMUNICATIONS".
4. ALL VEHICLE INDICATIONS SHALL BE 12", ALL VEHICLE AND PEDESTRIAN HEADS
SHALL BE PER SPECIAL PROVISIONS.
5, CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING
WITH SOUTHERN CALIFORNIA EDISION COMPANY WELL IN ADVANCE OF NEED.
6. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING
IS OPERATIONAL PER SPECIFICATIONS,
7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT
LOCATIONS PRIOR TO FINAL PLACEMENT,
8. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER,
9, CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKLER SYSTEMS IF NECESSARY,
10. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A
CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS
FOR THIS PROJECT.
11. AL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK.
12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS AND HARDWARE TO CONSTRUCT
THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXECPT AS NOTED TO
BE CITY FURNISHED, OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS.
0
m
m
mirr-
CONDUITS AND 4 -SACK
ORANGE PEA GRAVEL BACKFILL
DUCT INSTALLATION AND
TRENCH REPAIR DETAIL
INSTALLATION IN UNPAVC[ =El�
N.T.S.
DETAIL "C"
---------F—T
REVISION DESCRIPTION DATE ENGRCITY
p �r
C*43,1. E 1- 0 C A 710 N D ET A I L
CHECKED BY:
mm
FURNISH
AND INSTALL 2 CONDUIT WITH PULL ROPE FOR FUT. INTERCONNECT CABLE (6PR. #22),
FURNISH
AND INSTALL 6-1.5" SCHEDULE 40 HDPE CONDUITS WITH PULL ROPES PER DETAIL "C".
THE CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN,
CONDUIT
SWEEPS SHALL BE INSTALLED WITH A MINIMUM 1O --FOOT RADIUS.
CC' A
FURNISH
AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE
REQUIREMENTS. COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 &
CANERA
MILES 909-357-6505).
C*43,1. E 1- 0 C A 710 N D ET A I L
CHECKED BY:
mm