HomeMy WebLinkAbout3545-12 10 f RWY
CURTIS
ER
CLI
�u
0 >< D-
o
Z ol
0
z
U
PROJECT SITE
VICINITY MAP
THOMAS BROS. GUIDE
PAGE 574, `4
AVE,
uj
AVE.
CE) n
D
oz
BEING A CHIZLED "Q' ON FIRE HYDRANT FLANGE LOCATED
AT THE NORTH WEST CORNER Of MALOOF AND CARTER
ELEVATION 1527,13
DA515 Of DEARING
CENTERLINE OF COOPER AVENUE- N00"03'J O"E
PER CR 187/037
TOLL f KEE -qwsmw"' 1-800-227-2GOO
A PUBLIC SERVICE BY UNDERGROUND 5ERVICE ALERT
EXIST. RIW
INDEX MAP
SCALE J "= 40'
a
25'
COLDPLANE
MIN. 5'
EXIST. AC PAVING
rF-Xl5T. GROUND
20'
3 2'
2 5'
CON5TKL)CTION NOTE5/f-,5TIMATF-5 Of QUANTITIES*
INSTALL 4" AC OVER 12" MIN Of 95% COMPACTED NATIVE 5UBGRADE (1 925 5f)
48 TONS
7 1 CY AGG
INSTALL G" FCC CURB 4- GUTTER PER CITY 5TD 1003
G4 Lf
INSTALL 10 RE51DENTIAL DIW PER CITY 5TE) 1005
1 EA
INSTALL 51W PER CITY STD 101 5
5f
(D 5AWCUT EXIST AC PAVING. . . . . . .. . .
I G8 Lf
REMOVE EXIST AC PAVING,
728 5f
EXIST PP TO BE RELOCATED,
I FA.
GRIND 0. 1 O' EXIST PAVEMENT f, OVERLAY 0, 1 O' MIN. . . . . .
.720 5f
INSTALL REDWOOD HEADER
.40 Lf
*ESTIMATE 15 FOR FEE PURPOSES ONLY. CONTRACTOR 15 RESPONSIBLE
FOR OWN QUANTITIES.
"PRELIMINARY SECTION. FINAL SECTION TO BE DETERMINED BY SOILS
ENGINEER.
EXIST, PROPOSED
RA&/ WW
ADD'L DEDICATION PER
1 21 SEP DOCS
�55'
_TJ I
1 J4�- 0.5'
PROPOSED
SLOPE VARIES (4
1.4G% TO
2.70%
EXISTING SLOPE -
(VARIES 0.00% TO 2.OG%)
TYPICAL X-5ECTION
COOFE-K AVE
STA 7+64.60 TO 6+45.41
NT5
T.1,=5.5
2%
THE EXISTENCE AND LOCATION Of ANY UNDERGROUND UTILITY
FIFES, CONDUITS OR STRUCTURES SHOWN ON THESE PLANS ARE
OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE
BE -5T OF OUR KNOWLEDGE. THERE ARE NO EXISTING UTILITIES
EXCEPT A5 SHOWN ON THESE DRAWINGS. THE CONTRACTOR 15
REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT THE
UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR
FURTHER ASSUMES ALL LIABILITY AND RF5FON51BILITY FOR
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OF, NOT SHOWN
ON THESE DRAWINGS.
CONTRACTOR AGREES THAT HE SHALL A55UME 50LE AND COMPLETE
RESPONSIBILITY FOR JOb5ITF- CONDITIONS DURING THE COURSE OF
CONSTRUCTION Of THIS PROJECT, INCLUDING SAFETY OF ALL
PEK5ON5 AND PROPERTY; THAT TH15 REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS;
AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD
THE COUNTY, THE OWNER AND THE ENGINEER HARMLESS FROM ANY
AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE
PERFORMANCE OR WORK ON THIS PROJECT, EXCEPTING FOR
LIABILITY ARISING FROM THF50LE NEGLIGENCE Of THE OWNER
OR THE ENGINEER.
GRIND 0. 1 O' MIN.
EXIST. PAVEMENT
OVEkLAY 0. 1 O' MIN.
EX15TING-J
PAVEMENT
5' v I' ,
(MIN.)
N]
(MIN.) �f-5AVVCUT $ REMOVE
EXIST. PAVEMENT
(DCOLD PLANE DETAIL.
NT5
NEW PAVEMENT
REV. REV 15ION DE5CKIFTION DATf- FNGR, crrr' DATE I
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
SEAL:
0,
ME W
�D
CAO 1
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY Of FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CON5TRUCTION("GKEEN
BOOK"). ALL F'\FffKE-NCf- SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT 15 FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED
BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK'. THE CONTRACTOR SHALL IMMEDIATELY REPORT
SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION,
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL Of THF,CITYFNGINF-ER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY Of FONTANA ENGINEERING DIVISION PRIOR TO
THE START Of ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEASTTWOWORKING DAYS
PRIOR TO THE START Of ANY WORK IN PUBLIC RIGHT-OF-WAY WITI--IIN THE CITY LIMITS. CALL (909) 350-7G 10.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN THE STATE Of CALIFORNIA MANUAL Of TRAFFIC CONTROLS, LATEST
NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
G. IT SHALL BE RESPONSIBILITY Of THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS
OR OTHER. TRAFFIC CONTROL DEVICES AT ALL TIMES
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR,
TRENCHES 5 FEET OR GRATER IN DEPTH FROM CALIFORNIA STATE DIVISION OF INDUSTRIAL
SAFETY.
8. TFIF WALLS AND FACES Of ALL EXCAVATIONS GRATER THAN (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORTING, -9LOFING,Of THE GROUND OR OTHER APPROVED MEANS PURSUANT TO
THE REQUIREMENT Of THE DIVISION Of INDUSTRIAL SAFETY Of THE STATE Of CALIFORNIA.
TRENCHES LESS THAN (5) FEET 51-IALL ALSO BE GUARDED WHEN POTENTIAL Ex15T5 FOR GROUND
MOVEMENT,
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT AWAY WITH OUT
OBTAINING A 5fPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS Of THE UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE
INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY Of THE CONTRACTOR TO
DETERMINED, IN THE FIELD , THE TRUE LOCATION AND ELEVATION Of ANY EXISTING UTILITIES,
AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL
CONTACT UNDERGROUND 5E-KVICE ALERT AT 1-600-227-2GOO TWO WORKING DAYS BEFORE
EXCAVATION.
) I . THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GA5, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC
WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRAN5, ALL UTILITY COMPANIES
SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
) 2. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES
WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE
APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND AND WATER REQUIREMENTS.
13. CURVE DATA REFERS TO THE FACE CURB.
14. STATIONING REFERS TO THE CENTERLINE Of 5TKEET5 EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR 51-IALL BE RESPONSIBLE FOR THE
PRESERVATION Of BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION,
I G. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT Of EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCHMARKS. SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND 5URVE-YOK, SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT Of THIS CONSTRUCTION SHALL BE REPLACED. THE
CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION 50 THAT TIES TO MONUMENTS CAN
BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
15. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL KF51DFNT5 AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FEET LANE 511ALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND
EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS Of DUST CONTROL, INCLUDING
ADEQUATE WATERING AT ALL TIMES.
20. ALL GRADING OPERATIONS SMALL BE D15CONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES
PER HOUR.
2 1 . THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBR15 TO BE DEPOSITED
ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT Of WAY DURING CONSTRUCTION WITHOUT FKIOR
WRITTEN APPROVAL.
22, NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL Of THE CITY INSPECTOR.
23. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DEN51TY SHALL REQUIRE RE -WORKING OF THAT PORTION Of THE WORK UNTIL THE SPECIFIED DENSITY 15 OBTAINED.
24. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND 5WALE5 FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEADLE
5WALE5 ENTERING OR LEAVING IMPROVEMENTS.
25. THE FINAL LOCATION AND WIDTH Of DRIVEWAY APPROACH APRONS SHALL BE APPROVED AT THE TIME Of
CONSTRUCTION AND SHALL CONFORM TO THE CITY Of FONTANA STANDARD DETAILS.
2G. ALL EXPOSED CONCRETE SURFACE SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
27, THE SEWER CONTRACTOR SHALL STAMP "5" IN THE FACE Of THE CURB AT THE LOCATION Of THE SEWER
LATERAL,
28, NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING 5TIFEL HAVE BEEN PLACED,.
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
30. APPROVED 501L 5TERILANT IS REQUIRED UNDER ALL NE-WA5PHALT PAVEMENT PRIOR TOPLACEMENT.
3 1. PAVEMENT STRUCTURAL SECTIONS SHOWN ARE MINIMUM AND SUBJECT TO KF-VI510N AND APPROVAL Of THE
CITY ENGINEER. AS DETERMINED BY SOILS TESTS TAKEN AFTER COMPLETION Of ROUGH GRADING.
32. ACTUAL TIIICKNE55 Of A.C. PAVEMENT AND/OR BASE COURSE MATERIAL FOR STRUCTURAL STREET 5FCTION5
SHALL BE RECOMMENDED BY A GEOTECHNICAL REPORT AND SUBMITTED TO THE CITY OF FONTANA FOR APPROVAL
UPON COMPLETION Of ROUGH GRADING.
33, ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES 511ALL BE RAISED TO FINISHED GRADE
BY THE PAVING CONTRACTOR UPON COMPLETION Of PAVING,
34. UPON COMPLETION Of CONSTRUCTION, CONTRACTOR 511ALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND
OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION Of THE CITY TRAFFIC ENGINEER.
35. CONTRACTOR SMALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALKS AFFECTED BY
THE CONSTRUCTION TO THE SATISFACTION OF THE CITY ENGINEER.
3C. A5 -BUILT DRAWINGS 51-IALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER Of RECORD. WHO SHALL
PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
C I I U A 5 "KNIA
17' "" f f ul"NTANA CALIM
5TrRTET IMPR"u"VEMENT FLAN5
DRAWN BY: G327 COOF�R AVf NUE- SEAL
AFN 0226- 1(54-13
AS SHOWN
DESIGNED BY:
DATE:
M\VF
NOV 2002
cHFC�kE[) BY:
APP QVED 13Y°
DRAWING
NO.:
UAJ L:
3545 2