HomeMy WebLinkAbout3526-3W CLEAN BACK FILL SATURATE AND COMPACT TO 90% NATIVE BACKFILL 2" MINUS NON PRESSURE LATERAL LINE W/SLEEVE PRESSURE SUPPLY LINE W/SLEEVE -CONTROL WIRE SLEEVE SAND BACK FILL NQIM- INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE. SIZE PER SPEC. ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE UNE TO BE SLEEVED. i INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY INSPECTOR IF SLEEVES ARE TO BE USED AT A LATER DATE. CONTRACTOR SHALL TAPE ENDS AND PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL - ESU APPROVED BY: ft 25126 2 CITY ENGINEER DATE: ROBERT W. WEDDLE EV. 12/31/01 Dmvm BY: TIMOTHY RASTEOT_ !f awr uL0 DATE OF LAST REVISION: POP --UP SHRUB HEAD FINISH GRADE --, 12" SCH 80 PVC NIPPLE —� THREADED. BOTH ENDS CITY OF FONTANA SLEEVING DETAIL STD. PLAN NO. 518 1 SHT. i OF WALK OR CURB • PVC STREET ELLS NOTE: o INSTALL 12" SHRUB POP-UP HEAD 1 1/2" ABOVE F.G. o F.G. - 1 1/2"' BELOW WALK OR CURB o CHECK VALVE FOR LOW HEAD DRAINAGE 11%os1ss��� APPROVED BY: CITY OF FONTANA LAWN / 4!'6' 8" +a 25126 MY ENGINEER DATE: ROBERT W. W1=LE 5HKU5 PDP -UP HEAD DRAWN BY: TIMOTHY RA5TEDT am tf CAUL DATE OF LAST REVISION: STD. PLAN NO. 523 1 SHT. I OF 24" 77 EXACT LOCATION OF CONTROLLER SHAD. BE AGREED UPON BY EDISON. CITY LANDSCAPE INSPECTOR AND CONTRACTOR PRIOR TO ANY TRENCHING OR U WIRE PLACEMENT 360 GENERAL NOTES: PROVIOE 100A METER AND UM/2P MAIN C/9 WHERE INDICATED 12" ON ORAIIINGS PRO' W PANI"OARD WHERE POCATED ON ORAwWGS. PROME IRRICATION CONTROLLER CAMW WKRE INDICATED ON ORAWNG& TERMNATE AT EXISTION MAKNOLE. PER S.C.E. COMPANY RM 90 VERIFY EXACT LOCATION AND TERMINATION REO. WITH S.C.F. CO. SWEEP EUS CONTROLLER�R PRIOR TD T1tENCF1ING WIRES CONDUIT AND CONDuCM SIZES ARE 84SED ON NONMETALLEC CONM ANO COPPER CONDUCTORS WITH TYPE Pn*IN/3HMN" *WLATION. FRONT VIEW NTS IRRIGATION CONTROL 1 1 METER FACES I 1 U STREET METER I I I r i 36' STRONG BOX I I MODEL NO. SB— 24SS/120V I J I 1 t I 12' I I f 9d SWEEP CONDUIT FOR ELLS CONTROLLER WIRES END VIEW NIS._____ ELECTRIC METER & IRRIGATION CONTROLLER ENCLOSURE 1� oetol0s��,rAFMWVU:u IST: CITY OF FONTANA . k 2512 " CITY ENGINEER DATE: STRONG 13OX ROBERT W. WEDDLE * TJtp. 12/31/01 * DRAWN BY: TIMOTHY RmTEDT Crft El. ►tti3►�t DATE OF LAST REVISION: STD. PLAN NO. 505 1 SHT, 20F3 CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS (CFD'S) 1. Toro Network 8000 Model # 132-86-08, 32 station field satellite controller. 2. Mount in Strong Box Model NO. SB-24SS/ 12OV. (Stainless Steel) 3. Provide Roinmoster 32 PC 'Pigtail' for remote controll operation. 4. Provide Cambell Scientific Inc,TE525 tipping bucket (Heavy Duty Model) 5. Provide Sensor Input Board (SIB) Model #995-63 to interface with flow meter and rain shut off device. 6. Provide Radio Link Kit #89-7611 to communicate with central command. All radio equipment shall be compatible with VHF. 7. Provide ground rod and surge protection for each satellite controller. Contact: Curtis Newman California Turf 619 520•-6181 619 793--3999 Pager) 800 774--8873 Main Office) Pork and Landscape Development Section, Engineering Division Community Development Department, City of Fontana (1/26/98) Ett31py_f APPROVED BY: CITY OF FONTANA IW 25126 CITY ENGINEER DATE: CONTROLLER 5TANDARD ROBERT w WEDDLE E%P 12/31/01 * DRAWN BY: TIMOTHY RA5TEOT: I� COWL OWNER / DEVELOPER: NEW WEST HOME 369 SAN MIGUEL DRIVE, SUITE 375—A NEWPORT BEACH, CA 92660 (949) 640-6420 * FAX: (949) 640-6484 AE�dlDATE OF LAST REVISION: -- STD. PLAN NO. 505 1 SHT. 30F3 BENCHMARK: B.M. NO. 361 ELEV.= 1365.00 NAIL IN POLE #1536697E S.W. CORNER SULTANA & BASELINE MARK I BY I DATE ENGINEER 19 TAPE � BUNDLE CONTROL UJIRE 0 20' O/C (TYP.) "SNAP TITE" CONNECTORS d EXPANSION COILS, 15 WRAPS AROUND 1/2" PIPE (TYP.) ADAPT TO LATERAL LINE REMOTE CONTROL VALVE (PER LEGEND) CHRI5TY I.D. TAGS. SECURE TO SOLENOID PIGTAIL. FIN15H GRADE 1/2" IN TURF, 2" IN GROUND COVER 12" X 18" RECT. PLASTIC VALVE BOX WITH HINGED, LOCKABLE TOP COLOR -GREEN BRAND STATION I.D. ON LID PVC ELL 2"X4" REDWOOD FRAME 4" PEA GRAVEL CONTROL WIRE (TYP.) TO CONTROLLER PVC SCH 80 NIPPLE MAIN LINE WITH TEE OR ELL SLIPXSLIPXFIPT CONTROL WIRE TO OTHER VALVES COMMON WIRE TO OTHER VALVES REMOTE CONTROL VALVIM NOTE: ALL POWER WIRES. GROUND WIRES ETC. SHALL BE SEPARATELY SLEEVED AND SWEPT THROUGH ENCLOSED PAD WITH SCH 40 RNGID CONOUIT ALL SLEEVING SHALL BE A MINIMUM OF I8" BELOW FINISHED GRADE. ALL SLEEVING IS A GRAPHIC REPRESENTATION IRRIG. OF A TYP. INSTALLATION. CONT. SIZE OF EOUIPMENT a 45"W X I WO X 54' KGH AND _ �j4 REARS 12-A13 O C. TYPX 24'0 X 8' TNIGK III ' ' � � 71-11 =r; I411MKA11.,�SRASS Pot !'"�• u��i.l ♦ # # �I—.-ORASS BALL Rl• 14 RCOM E �r Siio"` FRONT F�+NTAISE) GRAVEL VV_ NOTE E�E OR"s CLOW • 811AM UNION r. • - SIIS HALL s. /4 REBAR PLAN Ll2 I • iS,.Ii++:r Ir14TE; OR tom 2 t"%�C:D'it 11IGH END Ii#iN W AT ONE END SECURE TO 6'X9' f0OTWC W/4" J BOLTS IEOWWW 10 K OENTEREO INSME H1 v$m) GENERAL NOTES I. CONTRACTOR SHALL FORM ENCLOSURE AND BEQUEST WSPECTION PRIOR TU P JMNG FOOTING/FOUNDATION 2. CONTRACFQR SHALL USE 520—C--2540 CONCRETE, ,tT911311 APPROVEO BY: CITY OF FONTANA IA Xgz. ?5175"° CIiY ENGINEER DATE: RosEW W WIC TYP. BACKFLOW EV. It/SIS * DPAWN 13Y: EMI3TI-iY I TI!0T- DATE OF LAS" REV18ION.. _�. STD. PIAN NA.507 SHT. 10F1 e'DIA. X 12'0. OF 14 BOTTOMLESS GROUND WELL WHITE WIRES i 3" WITH PARKWAY COVER. (COMMON) FILL WITH PEA GRAVEL BLUE ti• 4 WATERPROOF ALL 4" m'- 5/a-00 X 10. ORNEN GROUND WIRE CONNECTIONS ,. ROD PER ARTICLE 250-81 AS PER STD. OF 1990 NEC . RED BLACK PROVIDE 20 AMP 2 POLE BREAKER FOR NEV PUMPS WHERE APPLICABLE 50 A TEMPLATE 2P 124/240 0 3111 12 CIR PAM! r7�,, FINISHED GRADE GROUND FOR ELECTRICAL EXTRA 11' CONOIMS 3/4'C. till ELECTRIC METER & IRRIGATION CONTROLLER ENCLOSURE 1a6 25126 * EA 12/x1/01 aW� �l�tf of CAL1E� 'ter"""`W ";: CITY OF FONTANA wao CITY ENGINEER DATE: STRONG BOX ROSERT W. Wt:DDLE DRAWN BY: TIMOTHY RASTEOT DATE OF LAST REVISION: I STD. PLAN NO.505 ISHT. 1 OF3 3612 MISSION INN A VE ���q'�q RA RIVERSIDE, CALIF. 92501 LANDSO►T' LIC. ,41512 �► ast:IT22Ts PH. (909) 781-1930 m FAX (909) 686-8091 * I aue PREPARED BY: APPR_ DATE COUNTY �qT£ a e OF CAS-��� DATE: 9__ FLOW SENSOR DIAMETER SAME SIZE AS FLOW METER SIZE MINIMUM DISTANCE UPSTREAM 1OX DIAMETER OF FLOW METER SIZE MASTER CONTROL VALVE MINIMUM DI TANCE DOWNSTREAM 5X DIAMETER OF FLOW METER SIZE APPROVED BY: CITY OF FONTANA ���0Q1,OIES511 °` Crit ENGINEER DATE: FLOW METER/ ►�e 25121 E1- 12/31/01 * ROSE"W WEDDLE DRAWN BY: TIMOTHY RASTEDT. MASTER VALVE DATE OF LAST REVISION: j STD. PLAN NO. 510 1 SHT. 1 OF 1 CITY OF FONTANA, CALIFORNIA .Op PUBLIC WORKS DEPARTMENT DRAWN BY: PARKWAY LANDSCAPE PLAN SCALE: 1"_30,-0 FB FOR1, DESIGNED BY: _.T CT 1630 DATE: JE IRR) ATI D,ET DEC. 17,2003 CHECKED BY APPROVED8 llt DWG. NO. SHEET 4E —C ENG R-_RtARDO SA DOVAL, rC.E. 51152 3 OF 6