HomeMy WebLinkAbout3513-1STORM DRAIN GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL 0 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 0 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF o THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. N 0 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 0 OWNER 0 REGENCY CENTERS U ro 555 S. FLOWER ST., STE 3500 LOS ANGELES, CA 90071 (213) 553-2200 c d AtDevelopment Resource Consultants, Inc. Civil Engineering Land Surveying Land Planning r �7�8175 EAST KAISER BOULEVARD ANAHEIM HILLS, CA 92808 (714) 685-6860 J :21 CONSTRUCTION DRAWINGS FOR THE CITY OF FONTANA STORM DRAIN IMPROVEMENT PLANS STORM DRAIN GENERAL NOTES (CONT'D 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER 33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34. MINIMUM D -LOAD FOR ALL RCP IS 1350 35. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES MUST BE INCREASED TO PROVIDED A MINIMUM OF 1-1/2" OVER THE REINFORCING WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STRENGTH IN THESE REACHED SHALL BE fc = 5,000 PSI FOR VELOCITIES EXCEEDING 2 E SECOND AND fc = 6,00 FOR VELOCITIES XCE DING D. INDEX OF DRAWINGS SHEET NO. DESCRIPTION 1 TITLE SHEET 2 A STORM DRAIN LINE "A" 3 STORM DRAIN LINE "B" 4-5 ST0- M DRAIN "C" LF _LINE OR DRAIN L TERAL C- 5' HIGH BY 10' WIDE REINFORCED CONCRETE BOX PER CALTRANS STD PLAN NO. D80 Q 1755 LF O4 7-1 U__-^ -, T L SET TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT TRACT N0. 16235 SHT INDEX MAP SCALEi 1'=400' CONSTRUCTION NOTES & QUANTITIES: ............ ITEM DESCRIPTIOiV•��'"• Q�IAN,T'iTY- . UN•IT TRACT NO. 16235 O CONSTRUCT 54" RCP STORM DRAIN 1450 LF O 'Wir. 300 LF OCONSTRUCT 5' HIGH BY 10' WIDE REINFORCED CONCRETE BOX PER CALTRANS STD PLAN NO. D80 Q 1755 LF O4 CONSTRUCT MANHOLE PER APWA STD. PLAN NO. 320-1 min EA O5 CONSTRUCT TRANSITION STRUCTURE PER APWA STD. PLAN NO. 340-1 2 EA 6O CONSTRUCT MANHOLE PER APWA STD PLAN NO. 323-1 5 EA O7 CONSTRUCT JUNCTION STRUCTURE PER APWA STD. PLAN NO. 333-1 A 2 SHT INDEX MAP SCALEi 1'=400' CONSTRUCTION NOTES & QUANTITIES: ............ ITEM DESCRIPTIOiV•��'"• Q�IAN,T'iTY- . UN•IT TRACT NO. 16235 O CONSTRUCT 54" RCP STORM DRAIN 1450 LF O CONSTRUCT 48" RCP STORM DRAIN 300 LF OCONSTRUCT 5' HIGH BY 10' WIDE REINFORCED CONCRETE BOX PER CALTRANS STD PLAN NO. D80 Q 1755 LF O4 CONSTRUCT MANHOLE PER APWA STD. PLAN NO. 320-1 7 EA O5 CONSTRUCT TRANSITION STRUCTURE PER APWA STD. PLAN NO. 340-1 2 EA 6O CONSTRUCT MANHOLE PER APWA STD PLAN NO. 323-1 5 EA O7 CONSTRUCT JUNCTION STRUCTURE PER APWA STD. PLAN NO. 333-1 A 2 EA 6/4/04 CONSTRUCT JUNCTION STRUCTURE PER APWA STD. PLAN NO. 332-1 20 EA Og CONSTRUCT CONCRETE COLLAR PER APWA STD. PLAN NO. 380-3 29 /N�A 10 CONSTRUCT CSP PIPE RISER WITH DEBRIS RACK CAGE PER CALTRANS STD. PLANS D93A AND D93C STD. 3 EA 11 CONSTRUCT 18" RCP (2000D) 3 435 LF 12 CONSTRUCT CURB OPENING CATCH BASIN PER MODIFIED APWA STD PLAN NO. 300-2 Q 7 EA -� �6-�,T�,(�-SIE R�c�tQ��►��,--�--v--�--v--��,__��--�.__ �__ -�,�, �C�ION,�ST�UCT�.LRE�EIj,,APWAD�PLAI�N0,,�331-2-^�-- 15 CONSTRUCT JUNCTION STRUCTURE PER APWA STD. PLAN NO. 334-1 12 EA 16 CONSTRUCT 30" RCP (2000D) 3 80 LF 17 CONSTRUCT BOX CULVERT WARPED WINGWALLS PER CALTRANS STD. PLAN D86A. 1 EA 18 CONSTRUCT 24" RCP (2000D) L6(405 LF 19 NOT USED - LF ©0 INSTALL CONCRETE BLANKET PROTECTION PER APWA STD PLAN NO. 225-1 11 EA 21 C N RU Ily- If 1=2E�E �'ERv�AAi�I,�'- STD PLAN N0. D80 10 LF © CONSTRUCT TRANSITION STRUCTURE PER APWA STD PLAN NO. 342-1 1 EA 2 �G C1111 1111111 11 1 110 11 IS CONNECTION PER DETAIL ON SHEET 9 1 EA - -�4 ' ,QONSS.RtJCT�-3 =+ffcI-I Bl'� 3 =. �E •`R I_NFORC GQNCRETE QOa� PER ^ CALTRANS STD PLAN NO. D80 �•- % ' 350 �• LF 0 CONSTRUCT TRANSITION STRUCCTUREtRKk PP ► - D PLAN N0. 341-1 --'-'-'"• 1 EA - A M, 1, 1 , - I?E cope o 8 AS BUILT 07/21/05 �...� 7 REVISED LAT. & CB #C-14 11/02/04 -� REV. 1 REVISION DESCRIPTION PLAN CHECK ISSUE DATE ENGR. 2/2/0 CITY DATE 2 PLAN CHECK ISSUE 2/19/0 o L3_ REVISED SIZE OF RCB LINE C AND ALIGNMENTS OF 5/04/0 W z RCB LINE C & LAT C-13. REVISED LINE A ALIGNMENT Y w �A\ REALIGN RCB AND DELETED LAT. A-15 5/14/0 4 REVISED ALIGNMENT OF UNE A 5/19/0 >Q 5 REVISED ALIGNMENT OF LINE A 6/4/04 6 REVISED LAT. C-2 AND C-14 6/30/ AVENUE P aAw 1 N (5 �Q�kOFESS/�\ MIT�,y� te- 15 No. 45715 v r Exp. 12-31-06 .4 i . D ' LEGAL DESCRIPTION: \ PORTIONS OF THE EAST 1/2 OF THE SOUTHEAST 1/4 OF SECTION 23, TOWNSHIP 1 NORTH, RANGE 5 WEST AND THE WEST 1/2 OF THE SOUTHWEST 1/4 OF SECTION 24, TOWNSHIP 1 NORTH, RANGE 6 WEST, SAN BERNARDINO MERIDIAN, IN THE CITY OF FONTANA, COUNTY OF SAN BERNARDINO, STATE OF CALIFORNIA / SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL QR�Essi AGF-41TCe SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, cc Orn No. 45715 THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO Exp. 12-31-06 �q�, CIVIL BRING THEM INTO CONFORMANCE WITH CONDITIONS AND FoF CA��Fo STANDARDS IN EFFECT. 0 SAN GABRIEL MOUNTAINS NORTH SITE LOCATION 7a., �oI VICINITY MAP N.T.S. CAUTION: "THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." NOTICE TO CONTRACTOR: UTILITIES SHOWN HEREON AS "PROPOSED" MAY IN FACT BE EXISTING AT THE TIME OF THIS CONSTRUCTION. THE CONTRACTOR SHALL DETERMINE IF ANY "FUTURE OR PROPOSED" UTILITY HAS BEEN CONSTRUCTED. UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FORM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. UTILITY PURVEYORS: ELECTRICITY SOUTHERN CALIFORNIA EDISON CO. DISTRIBUTION PLANNING 7951 REDWOOD AVENUE FONTANA, CA 92335 (909) 357-6240 CONTACT: RON CARDENAS GAS SOUTHERN CALIFORNIA GAS CO. DISTRIBUTION PLANNING 16231 VALLEY BOULEVARD FONTANA, CA 92335 (909) 428-8407 CONTACT: DAVE PADILLA WATER SAN GABRIEL VALLEY WATER COMPANY 11142 GARVEY AVENUE EL MONTE, CA 91733 (626) 448-6183 CONTACT: S. STEVE GAO BENCHMARK: BENCHMARK #8-17 CALTRANS ELEVATION=1428.6090 BRASS CAP IN CONCRETE S.C.E. TOWER LEG, 343 FEET NORTH OF HIGHLAND AVENUE, 0.20 MILES WEST OF SAN SEVAINE ROAD, 2.65 MILES WEST ALONG HIGHLAND AVENUE, FROM SIERRA AVENUE. Prepared Under The Supervision Of : R.C.E. 45715 �hffibw DRAWN BY: EXP 12-31-06 AT DESIGNED BY.. JAM Date LMG 0012EyiIICi CITY OF FONTANA 8353 SIERRA AVENUE P.O. BOX 518 FONTANA, CA 92335 (909) 350-7610 OWNERAEVELOPER REGENCY REALTY GROUP, INC. 14200 CULVER DRIVE, SUITE S IRVINE, CA 92604 (949) 726-6000 CONTACT: LARRY G. LARSON VERIZON CALIFORNIA. INC. 13911 PARK AVENUE SUITE 200 VICTORVILLE, CA 92392-2407 (760) 245-0330 CONTACT: FRANK AUGUSTAIN BASIS OF BEARINGS: THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF LYTLE CREEK ROAD BEING N 00'40'42" W PER RECORD OF SURVEY 96-0149 FILED IN BOOK 108, PAGES 13-28, RECORDS OF THE COUNTY RECORDER OF SAN BERNARDINO COUNTY. CITY OF FONTANA, CALIFORNIA STORM DRAIN IMPROVEMENT PLANS TITL SHEET SCA S SHOWN T . 16235 DATE 2/19/04 APPR D DRAWING NO.: 1 R. .E. 51152 DATE: 3513 SUM AVENUE o o W z Y w > w z ♦000000 >Q c„ HIGHLAND AVENUE a w w U) U o: o J = U cn W D = W U 2 m U BASE LINE ROAD VICINITY MAP N.T.S. CAUTION: "THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." NOTICE TO CONTRACTOR: UTILITIES SHOWN HEREON AS "PROPOSED" MAY IN FACT BE EXISTING AT THE TIME OF THIS CONSTRUCTION. THE CONTRACTOR SHALL DETERMINE IF ANY "FUTURE OR PROPOSED" UTILITY HAS BEEN CONSTRUCTED. UNDERGROUND UTILITIES & STRUCTURES THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES. "CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS." PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FORM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. UTILITY PURVEYORS: ELECTRICITY SOUTHERN CALIFORNIA EDISON CO. DISTRIBUTION PLANNING 7951 REDWOOD AVENUE FONTANA, CA 92335 (909) 357-6240 CONTACT: RON CARDENAS GAS SOUTHERN CALIFORNIA GAS CO. DISTRIBUTION PLANNING 16231 VALLEY BOULEVARD FONTANA, CA 92335 (909) 428-8407 CONTACT: DAVE PADILLA WATER SAN GABRIEL VALLEY WATER COMPANY 11142 GARVEY AVENUE EL MONTE, CA 91733 (626) 448-6183 CONTACT: S. STEVE GAO BENCHMARK: BENCHMARK #8-17 CALTRANS ELEVATION=1428.6090 BRASS CAP IN CONCRETE S.C.E. TOWER LEG, 343 FEET NORTH OF HIGHLAND AVENUE, 0.20 MILES WEST OF SAN SEVAINE ROAD, 2.65 MILES WEST ALONG HIGHLAND AVENUE, FROM SIERRA AVENUE. Prepared Under The Supervision Of : R.C.E. 45715 �hffibw DRAWN BY: EXP 12-31-06 AT DESIGNED BY.. JAM Date LMG 0012EyiIICi CITY OF FONTANA 8353 SIERRA AVENUE P.O. BOX 518 FONTANA, CA 92335 (909) 350-7610 OWNERAEVELOPER REGENCY REALTY GROUP, INC. 14200 CULVER DRIVE, SUITE S IRVINE, CA 92604 (949) 726-6000 CONTACT: LARRY G. LARSON VERIZON CALIFORNIA. INC. 13911 PARK AVENUE SUITE 200 VICTORVILLE, CA 92392-2407 (760) 245-0330 CONTACT: FRANK AUGUSTAIN BASIS OF BEARINGS: THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF LYTLE CREEK ROAD BEING N 00'40'42" W PER RECORD OF SURVEY 96-0149 FILED IN BOOK 108, PAGES 13-28, RECORDS OF THE COUNTY RECORDER OF SAN BERNARDINO COUNTY. CITY OF FONTANA, CALIFORNIA STORM DRAIN IMPROVEMENT PLANS TITL SHEET SCA S SHOWN T . 16235 DATE 2/19/04 APPR D DRAWING NO.: 1 R. .E. 51152 DATE: 3513