Loading...
HomeMy WebLinkAbout3468-1CONDUCTOR TABLE AWG. CIRCUIT OR POLE2AA�Aa,A RUNS LUMINAIRE 1 2 3 4 5 6 7 8 9 10 1 PHASE 6 POLE O1 0-0-10-0-10-0-10-0-10-0-1 QUAD VEHICLE PED. MESSAGE A B O 26A-4-129 35' POLE 2O 15' 1-1-01-1-01-1-01-1-0 B 6P E MAS,MAS,SV-1-T SP -1 -CS Augusta Dr E 8' 4' F=18' POLE �3 1-1-01-1-01-1-0 SV -1-T w O 1-A 10' - - - B 8P a 00 POLE 4O SP -1 -CS - 12' 1-1-01-1-0 O 24A-4-129 35' 35' 15' 250W B 8P S MAS,MAS,SV-1-T SP -1 -CS Sierra Lakes Pkwy 12 4 F=18' ® 1-A 10, - - - B 2P W TV -2-T SP -1 -CS - 11' 4' cr_o I1-1-0 POLE O5 26A-4-129 35' 45' 15' 250W B 2P W MAS,MAS,SV-1-T SP -1 -CS H N 23' 4' F=18' © 1-A 10 - - - B 4P I POLE 6O SP -1 -CS - 23' 4' O 1-1-01-1-0 35' 45' 15' 0 B 4P N MAS,MAS,SV-1-T SP -1 -CS Sierra Lakes Pkwy 24' 4' F=12' ® 1-A z r� o POLE O - - B 6P E TV -1-T 1-1-01-1-01-1-0 - 24' 4' POLE O 1-1-01-1-01-1-01-1-0 TOTAL 0-0-11-1-12-2-13-3-13-3-1 4-4-03-3- 2-2-01-1-0 #10 LUMINAIRE 2 2 2 2 - - - 2 2 - VIDEO VIDEO CABLE 1 1 2 2 - 4 - 1 1 - DET. OPTICOM CABLE 1 1 2 2 4 -- CONDUIT SIZE 3" 3" 4" 4" 4" 3" 4" 4" 4" 3" No m 1 MOUNTING DETAIL MODEL 711 OPTICAL DETECTOR M 5 r is � O A Aft a� 1 L _ w� wRR cAKE ~i1 z m � — CURB LINE R/W LINE _ - _._----------- __,----- 04 0 i 43' + VARIES { Is 28' I VARIES CURB LINE POLE SCHEDULE L STANDARD MAST ARMS LUMINAIRE PHASE 1 PHASE 2 PHASE 3 PHASE 4 REMARKS 0 C TYPE HT. SIG. PHASE 5 1 PHASE 6 1 PHASE 7 1 PHASE 8 m 1 MOUNTING DETAIL MODEL 711 OPTICAL DETECTOR M 5 r is � O A Aft a� 1 L _ w� wRR cAKE ~i1 z m � — CURB LINE R/W LINE _ - _._----------- __,----- 04 0 i 43' + VARIES { Is 28' I VARIES CURB LINE POLE SCHEDULE L STANDARD MAST ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S.* PLACEMENT REMARKS 0 C TYPE HT. SIG. LUM. H. P. S. V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B O 26A-4-129 35' 40' 15' 250W B 6P E MAS,MAS,SV-1-T SP -1 -CS Augusta Dr E 8' 4' F=18' SV -1-T O 1-A 10' - - - B 8P S TV -1-T SP -1 -CS - 12' 4' O 24A-4-129 35' 35' 15' 250W B 8P S MAS,MAS,SV-1-T SP -1 -CS Sierra Lakes Pkwy 12 4 F=18' ® 1-A 10, - - - B 2P W TV -2-T SP -1 -CS - 11' 4' O 26A-4-129 35' 45' 15' 250W B 2P W MAS,MAS,SV-1-T SP -1 -CS Marketplace 23' 4' F=18' © 1-A 10 - - - B 4P N TV -1-T SP -1 -CS - 23' 4' O 26A-4-129 35' 45' 15' 250W B 4P N MAS,MAS,SV-1-T SP -1 -CS Sierra Lakes Pkwy 24' 4' F=12' ® 1-A 10' - - - B 6P E TV -1-T SP -1 -CS - 24' 4' * S.N.S. SHALL BE INSTALLED ON SHAFT MOUNTED CANTILEVER MAST ARMS **INSTALL AT 17' r I n� 1) { I ! r—R/W LINE I o w Lj N U Q O_j jl 2 I ! I. I + w�wn s i 1 / N z Ld O 3 w w _cnN Q J O / Ip I \� Q J z I 1 % V) J V r - v- / (- ' O D' (10Xwyi." ` \ T7 00 --------'- - --- -- t U i4 ------- - - — 0 CB 01 02 1� ---- - __ f- 05 i ; 05 I I2 / 8 v� 08 54 --- 3 O7 ®- — f 8 4g 8 - - - _ _ -- ®-..---- 7:_ AT 17 -STALL -- - d — -- -- - - - -- -- - - _ —_ --_--- _ - - - - -- ---_ _ - --- -- ------ - R34 5 --!-� f ------------- - 03 JOINT TRENCH - - - - - - - - -71 i G I 07 �"--\------------- 5R3�4- ;�; - -----------—---------�--- - la— ---�-- -- - 'tag - - -- _ __--- I�----__-- _ 3 --- _ - ----- ---------- 1011- I -- ---- ------ - ---_ ------ - {----- -- . _.W - j 4 7 2"C, 2 #6 SIGNAL - - _ _ rr !:y _ _ - - r — W -- -- --- -- -- -- -- - -- - --- -- _ _ - _ _ 4 5 �---- 04 ; ----- - 06 01 01 ® --- -- - - -I- ----- ----------I -- -,' 6 -- - - TRAFFIC SIGNAL GENERAL NOTESi — 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO WORKING DAYS BEFORE DIGGING. 3. ALL TRAFFIC SIGNAL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE BROOKS TYPE P48 WITH EXTENSIONS (OR APPROVED EQUAL), PER SPECIAL PROVISIONS. INTERCONNECT PULLBOX LIDS SHALL BE LABELED "COMMUNICATIONS". 4. ALL VEHICLE INDICATIONS SHALL BE 12". ALL VEHICLE AND PEDESTRIAN HEADS SHALL BE PER SPECIAL PROVISIONS. 5. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH SOUTHERN CALIFORNIA EDISION COMPANY WELL IN ADVANCE OF NEED. 6. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING IS OPERATIONAL PER SPECIFICATIONS. 7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 8. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 9. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. 10. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 11. AL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXECPT AS NOTED TO BE CITY FURNISHED, OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. I AFA File: 692.003 S-LAKESBASE.DWG 9:14 AM 11/04/03 Q D 0 DIAL TWO WORKING BEFORE .u. DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT F91Z r J w z i1 CO 00 j � rY 1 U z I- N CURB LINE w Curb/Bern or edge of 0a REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. SCALE 1"=20' SIDEWALK EXISTING CURB �- NATIVE SOIL AT 90% AND/OR j 8' COMPACTION (IF SIDEWALK CURB AND GUTTER DOES NOT EXIST, COMPACTED NATIVE SHALL BE FLUSH WITH SURROUNDING SURFACE.) 6-1.5"(41mm) SCH 40 HDPE O CONDUITS AND 4 -SACK ORANGE PEA GRAVEL BACKFILL DUCT INSTALLATION AND Q TRENCH REPAIR DETAIL N (INSTALLATION IN PARKWAY) ' N. T. S. EADER CUT TACK COAT 1' 1' ALL EDGES 0.03' LIP 44 10' MIN. EXISTING A.C. 3 " ••:' SURFACE EXISTING CURB NEW A.C. AND/OR CURB AND GUTTER 6-1.5"(41mm) SCH 40 HDPE CONDUITS AND 4 -SACK ORANGE PEA GRAVEL BACKFILL DUCT INSTALLATION AND TRENCH REPAIR DETAIL (INSTALLATION IN PAVED STREET) N. T. S. DETAIL "C" TRAFFIC SIGNAL CONSTRUCTION NOTE -Sm ❑1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECT- RONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. ❑2 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711 OR EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER. E4 INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND AS DIRECTED BY THE ENGINEER. ❑5 FURNISH AND INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -7N. ❑6 CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS. �7 FURNISH AND INSTALL 2" CONDUIT WITH 1 -INTERCONNECT CABLE (6PR. #22). �8 FURNISH AND INSTALL 6-1.5" SCHEDULE 40 HDPE CONDUITS PER DETAIL "C". THE CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN. FURNISH AND INSTALL INTERCONNECT CABLE (6PR. #22) PER CALTRANS SEC. 86-2.08E AS INDICATED IN THE ORANGE CONDUIT. FURNISH AND INSTALL PULL ROPES IN ALL'" THE REMAINING CONDUITS F FUTURE CABLE. CONDUIT SWEEPS SHALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS. a FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 & CANERA MILES 909-357-6505). 10 REMOVE AND SALVAGE TO CITY YARD EXISTING STREET LIGHT POLE COMPLETE WITH ALL EQUIPMENT. REMOVE FOUNDATION. 20 10 0 20 40 60 `rEFSipy9l�' F0 o) �2 A!/ST// -FOUST ASSOC/A rES, /NC. LU 20258 `rTi TRAfF/C ENC/NEER/NC ANO TRANSPORTAT/ON PL ANN/NO Exp.9-30-05 2020 NORTH US 111VENUE SANTA ANA, CALIFORNIA 92705-7827 J!. TELEPH 71 )' 67-0496 FAX (714) 667-7952 J : F S , RCE 20258 EXPIRE 9-30-05 DATE: SERVICE ADDRESS ---------- --------------------- CITY-OF FONTANA, CALIFORNIA TRAFFIC SIGNAL PLAN DRAWN BY; J.J.A. SIERRA LAKES PKWY. AND DESI EDJBAY. , UGUS 1A RIVE EAST CHECKED BY: APPR 0 BY- R.S. CITY ENGINEER R.C.E. 51152 DATE W D 'Q z W W o 0 Q I J CV I CV I- U W w 0 a - SCALE: V=20 DATE: 11/04/03 DRAWING NO.: , .1= 3468 t