Loading...
HomeMy WebLinkAbout3467-1CONDUCTOR TABLE AWG. CIRCUIT OR POLE RUNS LUMINAIRE AAAAAaAAa,A 8 9 10 1 PHASE 6 1 POLE O 0-0-1 0-0-1 0-0-1 0-0-1 0-0-1 SIG. LUM. H.P.S.V. TYPE PHASE QUAD POLE 1-1-0 1-1-0 1-1-0 1-1-0 O 26A-4-129 35' 45' 15' 250W POLE O3 6P E 1-1-0 1-1-0 1-1-0 10' 4' F=22' O 1-A w - - - B 8P S TV -1-T SP -1 -CS - 11' 4' cn POLE O 19A-4-129 35' 25' 1-1-0 1-1-0 B 8P S MAS,SV-1-T SP -1 -CS N 11' 7' ®1-A 10 - - - B 2P 0 I O POLE Q SP -1 -CS - 12' 4' O 1-1-0 35' 45' 15' N B 2P W MAS,MAS,SV-1-T SP -1 -CS Tiburon Way 15' 4' F=21' © 1-A U - I POLE �6 - - B 4P N TV -1-T 1-1-0 1-1-0 15' 4' 0 O 26A-4-129 35' 40' 15' 250W B 4P N MAS,SV-1-T SP -1 -CS z POLE O 8' ® 1-A 10' - 1-1-0 1-1-0 1-1-0 6P E POLE O SP -1 -CS - 16' 4' 1-1-0 1-1-011-1-0 1-1-0 TOTAL 0-0-1 1-1-1 2-2-1 3-3-1 3-3-1 4-4-0 3-3-0 2-2-0 1-1-0 #10 LUMINAIRE 2 2 2 2 - - - 2 2 - VIDEO VIDEO CABLE 1 1 2 2 - 4 - 1 1 - DET. OPTICOM CABLE 11 22 4 ' 11 CONDUIT SIZE 3" 3" (E) 4, 4" (E) 4, 3, 4- 4" 4" (E) 1 3 (E) INDICATES EXISTING CONDUIT WITH PULL ROPE BARRIER NOT USED L STANDARD MAST ARMS LUMINAIRE PHASE 1 PHASE 2 PHASE 3 PHASE NOT USED O __4 PHASE 5 1 PHASE 6 1 PHASE 7 1 PHASE 8 \+I 1, MAST -ARM md it POLE SCHEDULE L STANDARD MAST ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S.* PLACEMENT REMARKS O C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B O 26A-4-129 35' 45' 15' 250W B 6P E MAS,MAS,SV-1-T SV -1-T** SP -1 -CS Tiburon Way 10' 4' F=22' O 1-A 10' - - - B 8P S TV -1-T SP -1 -CS - 11' 4' O 19A-4-129 35' 25' 15' 250W B 8P S MAS,SV-1-T SP -1 -CS Sierra Lakes Pkwy 11' 7' ®1-A 10 - - - B 2P W TV -1-T SP -1 -CS - 12' 4' O 26A-4-129 35' 45' 15' 2501 B 2P W MAS,MAS,SV-1-T SP -1 -CS Tiburon Way 15' 4' F=21' © 1-A 10 - - - B 4P N TV -1-T SP -1 -CS - 15' 4' O 26A-4-129 35' 40' 15' 250W B 4P N MAS,SV-1-T SP -1 -CS Sierra Lakes Pkwy 15' 8' ® 1-A 10' - - - B 6P E TV -1-T SP -1 -CS - 16' 4' * S.N.S. SHALL BE INSTALLED ON SHAFT MOUNTED CANTILEVER MAST ARMS **INSTALL AT 17' i II CURB LINE MOUNTING DETAIL �> MODEL 711 OPTICAL DETECTOR " ,i Iii w �y I 29' 29' 0 Vr o_ I 22' 22' 0 ow It Z w o CURB LINE w W WI 1 �- 2 R/W LINE 0 Z Q1A Curb/Bern �- Z 111 CB I o U or edge of 0 U w `1 w R/W LINE In In w o U c'-- 3 0 9 to w>1A Z 3 m o Z o wDCi M + J? O i ii + _j Iw -Uw + to n _j ZDW wOf m �cwn I �, Urr O N � cn � ---_ Y p I — — — — — — �8-------- ' W2 02 sat, j 04 08t o7 - -�--- - - - - - - - - - - - - - - - - - - - ----:j 4 CBi o MOUNT AT 17' 8 C�; `� 9 8 In----------------------- 1 I --- ----------------- --- ---- `�' ---- ---- ---- ---- ---- ---- ' 3 ;---- -----! ------------------------------------------------ 5 --------- --------- --- R34JOINT TRENCH 07 ' ------------------ '15-7------------------------ 51 R34 G1 ------------------- 1 , -------------------------------------------------------------- --------+ EX. 3"C W/PULLROPE 3 FOR EDISON USE — ----- —-------- ---a , + --- - -- - ---- - - - - - -- ---- ---- Ln - - -- ---- - - -- - - -- ---- ------------------- -- ---- I 4 i } i CB 1 1 9 ' LUMINAIRES 03 3 O'2 I 04' S E • i 4 - 2 NAL o6"C, 2 #6 SIG – - - - - - -�— - ---_-- --- - – -- -—_- ----- - --- -- -- --- �.-- - - -- w 4 hS - --------- -- -06. ---------- -- 4P , ` i I TRAFFIC SIGNAL GENERAL NOTESi ( Z z P I 02� 7 J Z i U W POLE LOCATION DETAIL 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA m - - - - - - -- -------------- TRAFFIC SIGNAL CONSTRUCTION NOTESi r STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 2002). _ J 1 af U - - - 5 6 U ❑1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTORJO „ 6 TYPE "R" CABINET, AUTOSCOPE DETECTION, AND APPURTENANT EQUIPMENT. SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS " CB © CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. CB — 8 7 DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECT - PHONE UNDERGROUND SERVICE ALERT AT (800)227-2600, TWO WORKING DAYSt RONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON BEFORE DIGGING. ;; ,, 3 SIDEWALK THE PLAN. 3. ALL TRAFFIC SIGNAL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGIDEXISTING CURB / ❑2 INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND METAL UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXES SHALL BE AND/OR / , , COMP SOIL AI 90DEWALK , SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. BROOKS TYPE P48 WITH EXTENSIONS (OR APPROVED EQUAL), PER SPECIAL PROVISIONS. CURB AND GUTTER / 8 DOES NOT EACTIONXIST. COMPACTED CURB LINE �- CURB LINE INTERCONNECT PULLBOX LIDS SHALL BE LABELED "COMMUNICATIONS". NATIVE SHALL BE FLUSH WITH �3 INSTALL UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711 OR SURROUNDING SURFACE.) 34.1 1 t u 22' EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER. 4. ALL VEHICLE INDICATIONS SHALL BE 12". ALL VEHICLE AND PEDESTRIAN HEADS 6-1.5'(41mm) SCH 40 HDPE + I SHALL BE PER SPECIAL PROVISIONS. CONDUITS AND 4 -SACK„ �4 INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND ORANGE PEA GRAVEL BACKFILL AS DIRECTED BY THE ENGINEER. 5. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING DUCT INSTALLATION AND + 11 TRENCH RA EPAIR DET IL ” Is WITH SOUTHERN CALIFORNIA EDISION COMPANY WELL IN ADVANCE OF NEED. 6. EXISTING LIGHTING SHALL REMAIN IN OPERATION UNTIL NEW SIGNAL AND LIGHTING IS OPERATIONAL PER SPECIFICATIONS. 7. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. 8. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. PROPOSED CURB AND9. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. CURB AND GUTTER MODIFY SPRINKLER SYSTEMS IF NECESSARY. 10. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND/OR SPECIFICATIONS FOR THIS PROJECT. 11. AL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXECPT AS NOTED TO BE CITY FURNISHED, OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. To I p O REV. I _ n AFA File: 692.003 S-LAKESBASE-ABC.DWG 5:06 PM 03/16/04 TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT (INSTALLATION IN PARKWAY) N.T.S. ;ED A.C. E 0-1.j k -+,mm) _m n -+v nvrr- CONDUITS AND 4 -SACK ORANGE PEA GRAVEL BACKFILL DUCT INSTALLATION AND TRENCH REPAIR DETAIL (INSTALLATION IN UNPAVED STREET) N.T.S. DETAIL "C" REVISION DESCRIPTION DATE ENGR. CITY �7 Elf DW45. 6/•!5 Irrf�*. ,Z oprz N43"_7"ws9WTo Al4.5W1l' o to, -r& rte, z DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL 0. •i SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. SCALE 1"=20' 00, .SSIO Nq�\ 4o�EFO� � No. � LU 20258 * Exp, 9.30-05 # OFC -d�� a FURNISH AND INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL U , ES -7N. ❑6 CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S REQUIREMENTS. 77 FURNISH AND INSTALL 2" CONDUIT WITH 2 -INTERCONNECT CABLE (6PR. #22). F8 EXISTING 6-1.5" SCHEDULE 40 HDPE CONDUITS PER DETAIL "C", WITH ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN CONDUITS. FURNISH AND INSTALL INTERCONNECT CABLE (6PR. #22) PER CALTRANS SEC. 86-2.08E AS INDICATED IN THE ORANGE CONDUIT. 191 FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE (DAVID QUEZADA 909-357-6240 & CANERA MILES 909-357-6505). 10 FURNISH AND INSTALL 2 -INTERCONNECT CABLE (6PR. #22) IN EXISTING CONDUIT. s�IISTIMF®!/Sr A JSOCIA %%ES INC. TRAFFIC £NCIN££RINO ANO TRANSPORTATION PLANNING 2020 NORT TU TI AVENUE SANTA ANA, CALIFORNIA 92705-7827 TELE P �( 667-0496 FAX (714) 667-7952 G _ J . F U T, RCE 20258 EXPIRE 9-30-05 DATE: � -/?-0 el SERVICE ADDRESS CITY OF FONTANA, CALIFORNIA TRAFFIC SIGNAL PLAN DRAWN BY: SC J.J.A. SIERRA LA PKWY. AND 1ALE=_2a - DESIGNED BY: TI p A`/ DATE: J.J.A. �3 I 3/17/04 CHECKED BY: D BY: DRAWING NO.: t 3467 R.S._fUn ENGMEER R. .E. 51152 DAT