Loading...
HomeMy WebLinkAbout3448-7F ,`DI F OPTIONAL OUTSIDE EDGES TO BE EDGE OF CONCRETE ROUNDED TO D BARS 75 mm (31) R 75 mm (31) OC R I019•3) TIE BAR )P �- R=ID OF SPUR C L r 1 Ci 4-20M(06). E BARS At _ 975 mm (3'-3') LONG. J SEE NOTE 2- 4-I5M(°4) H D BARS _-IOM(°3) TIE BAR BARS 3R_ O•) LONG 75 mm (31) OC. 1.2 m SEE NOTE 93-15M(#4) J BARS 1.4 m (4'-0') (4•-8') LONG 75 mrn(3•) OC COWT.ADD'L. BARS 130 mm DETAIL 'N" F D2 F (69 OC TO INSIDE EDGE SEE NOTE 2 (RINGS AND COVER NOT SHOWN) OF MANHOLE. PLAN (SEE NOTE I) (SHAFT NOT SHOWN) MANHOLE FRAME STREET AND COVER PER GRADE STD. PLAN 630 PUBLIC WORKS STANDARDS RDSDS MC., GREENBOOKCTE OMMITE Isss RING SEAT 610 mm (24.1 a- H BARS MANHOLE SHAFT - at- SEE TABLE 125 mm x 50 mm m PER STD. 2Sj 160 mm 15'x2') ` PLAN 324 150 mm (6 PIPE SEAT 29 s 4 900 mm (3'-01 400 mm (161) FOR E BARS W IOM(•3 OR 94) PAVED STREETS. rn (61 F TIE BARS 650 mm (2'-21) FOR 300 mm 11 3/4' 2100 mm (84' 320 mm (12 I/2"1 STEPS 33 mm I/4! 40 mm (9611 TIE BARE 2550 mm (102') - 125 mm (5.1 F ' F J BARS ROUND EDGES .- 430 mm (17' TO 75 mm (31) R 443 mm 17 i/2`) SPRING LINE ISM(e4) 0 450 mm 453 mm tib• INLET (IT) OG BOTH M v -' ELEVATION WAYS TO BE USED APPLIES AT WHEN D= IS 1500 mrn THIS POINT (60.1 OR OVE SECTION A -A CONCRETE RINGS PIPE SEAT LEVEL. I SEE NOTE 8 E BARS Il I GRADE POINTS. \\ SEE NOTE 4 SECTION B -B PER STD.STREET GRADE PLAN 324 123 mm x 23 mm (51x1') PUBLIC WORKS STANDARDS RDSDS MC., GREENBOOKCTE OMMITE Isss RING SEAT OMIT TNIS STEPPAVED a- H BARS ( TO 75 mm ,(3') R - at- SEE TABLE STREETS am VARIABLE SECTION C -C 2Sj 160 mm H BARS ` 150 mm (61) 150 mm (6 W a s 4 E BARS 400 mm (161) FOR to M 50 IOM(•3 OR 94) PAVED STREETS. F (61 F TIE BARS 650 mm (2'-21) FOR 300 mm 11 3/4' 2100 mm (84' 320 mm (12 I/2"1 UNPAVED STREETS 33 mm I/4! 40 mm (9611 J BARS c AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATEDMANHOLE PIPE TO PIPE MAIN LINE ROUND PUBLIC WORKS STANDARDS RDSDS MC., GREENBOOKCTE OMMITE Isss --T Tom`-' 320-1 EDGES ( TO 75 mm ,(3') R TO 75 mm USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (3')R SECTION C -C 673 mm (2T•) c AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATEDMANHOLE PIPE TO PIPE MAIN LINE STA N .PLA" mETm PUBLIC WORKS STANDARDS RDSDS MC., GREENBOOKCTE OMMITE Isss ID=900 mm 3611OR LARGER 320-1 REV, 1998 ( TO 75 mm ,(3') R SHEET l OF 4 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION 4. MAIN LINE RCP OR REINFORCED MONOLITHIC ARCH. SEE NOTE 2 80 mm (3') SPUR - REINFORCING STEEL I I 80 mm (31) MIN. LINE NG !� /ROUND( I' EDGESrr- ELEV. I S { UNDISTURBED SECTION Z -Z 40 STA. POINT CONNECTOR P I 80 mm SEE NOTE 3 (3') MIN. STA. POINT LATERAL SEE NOTE 3 PLAN IOM O 430 mm 03 OR 04 O 18') OC TIE BAR G BARS I5M O 150 mm 04 O 61) OC y-( o�_ I13EI.m 0 Mo EV. R BARS 15M t•5) 80 mm l3') OC r'1 F BARS 15M (•S) O 73 mm 131) OC �- CONCRETE CRADLE. 263-C-14 (450-C-2000). SEE NOTE 9 E LATERAL/ CONNECTOR PIPE •G BARS 15M O 130 mm (•4 O 61) OC -IOM 0 450 mm (93 OR •4 O 181 OC TIE BARS •E AND F BARS 15M075 mm (•S O 31) OC. SEE NOTE 8 TABLE OF VALUES FOR T I (ROUND H 130 mm (5") EDGE I as °D ( TO 75 mm ,(3') R � o Zt _ M_ 673 mm (2T•) 1 750 mm (301) 150 mm (61) 823 mm (331 W a ii o 1 I I N W to M I6S mm 66•) SPUR - REINFORCING STEEL I I 80 mm (31) MIN. LINE NG !� /ROUND( I' EDGESrr- ELEV. I S { UNDISTURBED SECTION Z -Z 40 STA. POINT CONNECTOR P I 80 mm SEE NOTE 3 (3') MIN. STA. POINT LATERAL SEE NOTE 3 PLAN IOM O 430 mm 03 OR 04 O 18') OC TIE BAR G BARS I5M O 150 mm 04 O 61) OC y-( o�_ I13EI.m 0 Mo EV. R BARS 15M t•5) 80 mm l3') OC r'1 F BARS 15M (•S) O 73 mm 131) OC �- CONCRETE CRADLE. 263-C-14 (450-C-2000). SEE NOTE 9 E LATERAL/ CONNECTOR PIPE •G BARS 15M O 130 mm (•4 O 61) OC -IOM 0 450 mm (93 OR •4 O 181 OC TIE BARS •E AND F BARS 15M075 mm (•S O 31) OC. SEE NOTE 8 TABLE OF VALUES FOR T B T 300 mm 02.1 130 mm (5") 373 mm (15) 130 mm (S') 450 mm (181) 130 mm (51) $23 mm (21'1 130 mm (51) 600 mm 1249 140 mm (5 1/21) 673 mm (2T•) 140 mm 13 I/2') 750 mm (301) 150 mm (61) 823 mm (331 170 mm (6 I/2') 900 mm (361) 170 mm (6 1/21) SECTION M -M BARS BARS AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THESTA JUNCTION STRUCTURE - PIPE TO PIPE INLET PIAN PUBLIC WOWS STANDARDS INC.. GREENBOOK COMMITTEE ID > 600 mm (24") OR -ID > 1/2 MAIN LINE ID METNDARD RIC 331-2 ,9 84 190. mm, 7 1/ 1125 mm 45• REV. 1990 SHEET I OF 2 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION TABLE OF VALUES FOR FDa TABLE OF VALUES FOR M (SEE NOT I F 0 mm 36•) 165 mm 1/2.1 975 mm 39.1 18 mm 7' 1050 mm 4;.)) 2' 190. mm, 7 1/ 1125 mm 45• t9S mm t 3/4•) 1200 mm (48' 2 mm 8'I 1275 mm (Sl` 215 mm S i/2'), mnt 4' 230 mrn ' 1423 mr» (5T 3 mm 14' 1500 mm 6 40 m I/2". 137 mm 63' 255 mm (10• I6S mm 66•) 26 mm 10 I/4• 1725 mm (69-1... m 10 374-1- 73 m /4• 18 0 mm (72• 1800 280 mm (II') I mm t7 300 mm 11 3/4' 2100 mm (84' 320 mm (12 I/2"1 0 mm ( 33 mm I/4! 40 mm (9611 353 mm 14• (IR -ii 2550 mm (102') 395 mm (13 I/2') 2700 mm (I 8') 403 mm (16') 2850 mm (1i4') 30 O mm (12 420 m3600 m (t6 I/2`) 430 mm (17'1 3iSO mm t 430 mm (17' 33 0 mm (132' 443 mm 17 i/2`) .450 mm (138•) 443 mm 17 I/2') mm 144• 453 mm tib• M v V L- AMERICAN 320 -1 PIPE TO VIVE MAIN LINE - TABLE OF VALUES FOR FDa TABLE OF VALUES FOR M (SEE NOT I F 0 mm 36•) 165 mm 1/2.1 975 mm 39.1 18 mm 7' 1050 mm 4;.)) 2' 190. mm, 7 1/ 1125 mm 45• t9S mm t 3/4•) 1200 mm (48' 2 mm 8'I 1275 mm (Sl` 215 mm S i/2'), mnt 4' 230 mrn ' 1423 mr» (5T 3 mm 14' 1500 mm 6 40 m I/2". 137 mm 63' 255 mm (10• I6S mm 66•) 26 mm 10 I/4• 1725 mm (69-1... m 10 374-1- 73 m /4• 18 0 mm (72• 1800 280 mm (II') I mm t7 300 mm 11 3/4' 2100 mm (84' 320 mm (12 I/2"1 0 mm ( 33 mm I/4! 40 mm (9611 353 mm 14• (IR -ii 2550 mm (102') 395 mm (13 I/2') 2700 mm (I 8') 403 mm (16') 2850 mm (1i4') 30 O mm (12 420 m3600 m (t6 I/2`) 430 mm (17'1 3iSO mm t 430 mm (17' 33 0 mm (132' 443 mm 17 i/2`) .450 mm (138•) 443 mm 17 I/2') mm 144• 453 mm tib• AMERICAN PUBLIC WORKS ASSOCIATION -SOUTHERN CALIFORNIA. CHAPTER TABLE OF VALUES FOR M (SEE NOT I MANHOLE PIPE TO PIPE- NlAli�t LINE SECTION PAVED STREET MAX. MIN. UNPAVED STREET MAX. MIN. A -A 867 mm (2'-I0 1/2.1 I FACE PLATE 1060 mm t3'-6') C -C 28 mm il' 217 mm (8 I/2') 414 mm (16'1 380 mm (iS') AMERICAN PUBLIC WORKS ASSOCIATION -SOUTHERN CALIFORNIA. CHAPTER STANDARD PIAN METRIC w2p"`. � 320 - 1 MANHOLE PIPE TO PIPE- NlAli�t LINE ID=900 mm JB" OR LARGER ID=900 mm 36" OR LARGER SHEET 2 OF 4 NOTES I. THIS JUNCTION STRUCTURE SHALL BE USED WHEN THE OUTSIDE DIAMETER OF THE LATERAL IS GREATER THAN 1/2 THE INSIDE DIAMETER D OF THE MAIN LINE; OR WHEN THE INSIDE DIAMETER 8 OF THE LATERAL IS GREATER THAN 600 mm (240). B SHALL NOT EXCEED .75 D OR 975 mm (392). 2. IF THE MAIN LINE IS A REINFORCED MONOLITHIC ARCH STORM DRAIN. D SHALL REFER TO THE CLEAR SPAN OF THE ARCH. REINFORCING STEEL SHALL BE CUT AND BENT INTO THE JUNCTION STRUCTURE IN THE SAME MANNER AS FOR A PIPE. A CONCRETE CRADLE IS NOT REQUIRED FOR A REINFORCED MONOLITHIC ARCH. 3. STATIONS SHOWN ON THE PROJECT DRAWINGS FOR LATERALS APPLY AT THE INTERSECTION OF CENTER LINE OF MAIN IN AND RA STATIONS S LINE A LATERAL. S 0 5 SHOWN ON THE PROJECT DRAWINGS FOR CATCH BASIN CONNECTOR PIPES APPLY AT THE INTERSECTION OF THE INSIDE WALL OF THE MAIN LINE WITH THE CONNECTOR PIPE CENTER LINE. 4. VALUES .FOR A. 8. C AND D SHALL BE SHOWN ON THE PROJECT DRAWINGS. Y TION HAL SHOWN ON WHEN IR P ELEVATION R AND ELEVATION S SHALL BE S O N LY E REQUIRED PER NOTE 5. 5. a. ELEVATIONS R AND S NEED NOT BE SHOWN ON THE PROJECT DRAWINGS IF THE INLET PIPE IS TO ENTER THE MAIN LINE RADIALLY. b. ELEVATION R SHALL BE SHOWN ON THE PROJECT DRAWINGS ONLY IF A STUB IS TO BE PROVIDED IN THE MAIN LINE FOR FUTURE CONNECTION OF AN INLET PIPE. c. ELEVATION S SHALL BE SHOWN ON THE PROJECT DRAWINGS IF AN INLET PIPE IS TO ENTER THE MAIN LINE OTHER THAN RADIALLY. INLET PIPE SHALL BE LAID ON A STRAIGHT GRADE FROM ELEVATION S TO THE CATCH BASIN OR GRADE BREAK IN LINE. 6. THE INLET PIPE SHALL ENTER THE MAIN LINE RADIALLY UNLESS OTHERWISE INDICATED. THE INLET PIPE MAY ENTER THE MAIN LINE OTHER THAN RADIALLY IF ANGLE A IS GREATER THAN 450 8 IS LESS THAN OR EQUAL TO 600 mm (24') AND THE OUTSIDE DIAMETER OF THE INLET PIPE IS LESS THAN .5 D: OTHERWISE. STANDARD PLAN 340 SHALL BE USED. 7. NO MORE THAN ONE OPENING SHALL BE MADE IN ANY ONE SECTION OF PIPE. 8. THE OPENING FOR THE BREAKOUT SHALL BE RECTANGULAR AND CUT NORMAL TO THE PIPE SURFACE WITHOUT DAMAGING THE REINFORCING STEEL. THE TRANSVERSE REINFORCEMENT OF THE MAIN LINE SHALL BE CUT AT THE CENTER OF THE OPENING AND BENT INTO THE TOP AND BOTTOM SLABS OF THE SPUR. 9. THE MAIN LINE SHALL BE REINFORCED WITH A CONCRETE CRADLE AND ENCASEMENT (AS APPLICABLE). A CONCRETE ENCASEMENT IS REQUIRED IF A JOINT IN THE MAIN LINE FALLS WITHIN THE LIMITS OF THE CRADLE. THE CONCRETE ENCASEMENT SHALL EXTEND 300 mm (12') ABOVE THE TOP OF THE MAIN LINE AND TO THE LIMITS OF THE CRADLE.. IF CONNECTING TO AN EXISTING STORM DRAIN, PORTION OF CRADLE OPPOSITE INLET MAY BE OMITTED. 10. REINFORCING STEEL SHALL CONFORM TO ASTM A 615M. GRADE 300. (ASTM A 615. GRADE 40). AND BE PLACED 40 mm (1 1/20) CLEAR FROM CONCRETE SURFACES, UNLESS OTHERWISE SHOWN F BARS SHALL BE CARRIED TO A POINT NOT LESS THAN J DISTANCE FROM CENTER LINE WITH J=70/12 + 150 mm (6'). If. FLOOR OF THE SPUR SHALL BE STEEL -TROWELED TO THE SPRING LINE OF THE SPUR. 12. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING BARS SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN ,CALIFORNIA CHAPTER STANDARD PLAN ETRIC 331 2 SHEET20F2 JUNCTION STRUCTURE --PIPE TO PIPE INLET ID Z 600 mm 24" OR > 112 MAIN LINE ID TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION s NOTES I. WHEN DEPTH M FROM STREET GRADE TO THE TOP OF THE BOX IS LESS THAN 867 mm (2'-10 1/29 FOR PAVED STREETS OR 1060 mm (3'-61 FOR UN- PAVED STREETS. CONSTRUCT MONOLITHIC SHAFT PER SECTION C -C AND DETAIL 'N'. SHAFT FOR ANY DEPTH OF MANHOLE MAY BE CONSTRUCTED PER SECTION C -C. WHEN DIAMETER DI 13 1200 mm (481 OR LESS, CENTER OF SHAFT MAY BE LOCATED PER NOTE 2. 2. CENTER OF MANHOLE SHAFT SHALL BE LOCATED OVER CENTER LINE OF STORM DRAIN WHEN DIAMETER DI IS 1200 mm (484 OR LESS. IN WHICH CASE PLACE E BARS SYMMETRICALLY AROUND SHAFT AT 456 WITH CENTER LINE AND OMIT J BARS. 3. L AND P SHALL HAVE THE FOLLOWING VALUES UNLESS OTHERWISE SHOWN ON THE PROJECT DRAWINGS: A. D2=2400 mm (96.1 OR LESS. L=1.7 m (5'-6'). P=130 mm (301 B. D2 OVER 2400 mm (96'), L=1.8 m (6'-0'). P=210 mm (8') L MAY BE INCREASED OR LOCATION OF MANHOLE SHIFTED TO MEET PIPE ENDS. WHEN L GREATER THAN THAT SHOWN ABOVE IS SPECIFIED, D BARS SHALL BE CONTINUED 150 mm .(61) OC. 4. STATIONS OF MANHOLES SHOWN ON PROJECT DRAWINGS APPLY AT CENTER LINE OF SHAFT. ELEVATIONS ARE SHOWN AT CENTER LINE OF SHAFT AND REFER TO THE PROLONGED INVERT GRADE LINES. 5. REINFORCEMENT SHALL CONFORM TO ASTM A 615M. GRADE 300 (ASTM A 615. GRADE 40). AND SHALL TERMINATE 40 mm (1 1/20) CLEAR OF CONCRETE SUR- FACES UNLESS OTHERWISE SHOWN. 6. FLOOR OF MANHOLE SHALL BE STEEL TROWELED TO SPRING LINE. 7. BODY OF MANHOLE SHALL BE POURED IN ONE CONTINUOUS OPERATION EXCEPT THAT -A CONSTRUCTION JOINT WITH A LONGITUDINAL KEYWAY MAY BE PLACED AT SPRING LINE. 8. THICKNESS OF THE DECK SHALL VARY WHEN NECESSARY TO PROVIDE A LEVEL SEAT BUT SHALL NOT BE LESS THAN THE TABULAR VALUES FOR F SHOWN ON TABLE SH. 2. 9. D BARS SHALL BE 15M(°4) FOR D2=975 mm(39') OR LESS. 15M(05) FOR 02 =1050 mm (42.1 TO 2100 mm (84'1 INCLUSIVE AND 20M(°6) FOR 02=2250 mm (908) OR OVER. 10. CENTER LINE OF INLET PIPE SHALL INTERSECT INSIDE FACE OF.CONE AT SPRING LINE UNLESS OTHERWISE SHOWN. I1. STEPS SHALL CONFORM TO STANDARD PLAN 635 OR 636 UNLESS OTHERWISE SHOWN. STEPS SHALL BE UNIFORMLY SPACED 350 mm (141 TO 375 mm (154 OC. THE LOWEST STEP SHALL NOT BE MORE THAN 600 mm (24') ABOVE THE INVERT. 12. THE FOLLOWING CRITERIA SHALL BE USED FOR THIS MANHOLE: A. MAIN LINE - 900 mm 1364 INSIDE DIAMETER OR LARGER. EXCEPT IF THE MAIN LINE RCP DOWNSTREAM OF MANHOLE IS 900 mm (361 TO 1050 mm (420) INSIDE DIAMETER AND THE MAIN LINE RCP UPSTREAM IS 825 mm (330) OR LESS STANDARD PLAN 321 SHALL BE USED. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PIAN METRIC 320 - 1 MANHOLE PIPE TO PIPE MAIN LINE p ID=900 mm 36" OR LARGER - SHEET 3OF4 W r O 8 J '15M O 300 mm(04012'1 EACH WAY -5 mm(1/41)R 1 STANDARD PLAN 32METRIC 0-1 SHEET40F4 100 mm (4')R STANDARD !AN PROMULGATED THE PUBLIC WORKS STANDARDS INC. �CURE,OPENING CATCH BASIN FLOW LINE GREENSOOK COMMITTEE I FACE PLATE 300 �TY I Rte' 1B88 SHEET 1 OF 2 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SCORING i POINT E a CURB LINE 2 EXTRA {5M(•4) I I STEPS OMANHOLEFRAOF ME I ( t IAND COVER I I CATCH BASIN I MANHOLE FRAIAE I Ia a AND COVER M v V L- O;STEPS ' _1 DOWEL iTYP.) PLAN / -100 mm FACE PLATE ASSEMBLY STREET CER O)L OUT' SSIION SURFACI �_l - _ _ �I Ldl A X. 3.u (41MIINN. ' 0 mm 75 mm '0)MAX -OPTIONAL SUBGRADE CONNECTOR PIPE oR MONOLITHIC B CONNECTIONN SECTION A -A 200 mm(8') IOMI•4) �j90• DOWEL DETAIL AMERICAN PUBLIC WORKS ASSOCIATION • SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 32METRIC 0-1 SHEET40F4 MANHOLE PIPE TO PIPE MAIN LINE ID=900 mm 36" OR LARGER STANDARD !AN PROMULGATED THE PUBLIC WORKS STANDARDS INC. �CURE,OPENING CATCH BASIN E -4CATCH Iii GREENSOOK COMMITTEE 300 I N4 - Rte' 1B88 SHEET 1 OF 2 USE WITH STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION B. THE OUTSIDE DIAMETER OF THE LATERAL MUST BE LESS THAN OR EQUAL TO 1/2 THE INSIDE DIAMETER OF THE MAIN LINE. IF THE UPSTREAM AND DOWNSTREAM DIAMETERS OF THE MANHOLE ARE NOT THE SAME. THE GOVERNING INSIDE DIAMETER OF THE MAIN LINE SHALL BE CONSIDERED TO BE THAT WHERE THE EXTENDED CENTER LINE OF THE LATERAL ENTERS THE MANHOLE. C. IN NO INSTANCE SHALL THE INSIDE DIAMETER OF THE LATERAL TO THE MANHOLE BE GREATER THAN 750 mm (309. 13. MANHOLE FRAME AND COVER SHALL CONFORM TO STANDARD PLAN 630 UNLESS OTHERWISE SHOWN. 14. MANHOLE SHAFT SHALL CONFORM TO STANDARD PLAN 324 UNLESS OTHERWISE SHOWN. 15. WHERE A MANHOLE SHAFT - 900 mm (36') WITHOUT REDUCER IS SPECIFIED REFER TO STANDARD PLAN 326. 16. WHERE A PRESSURE MANHOLE SHAFT - WITH ECCENTRIC, REDUCER IS SPECIFIED REFER TO STANDARD PLAN 328. 17. WHERE A PRESSURE MANHOLE SHAFT - 914 mm (360) WITHOUT REDUCER IS SPECIFIED REFER TO STANDARD PLAN 329. 18. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES. EXCEPT REINFORCING BAR SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. THE FOLLOWING STANDARD PLANS'ARE INCORPORATED HEREIN: 324 MANHOLE SHAFT - WITH ECCENTRIC REDUCER 326 MANHOLE SHAFT - 900 mm (369 WITHOUT REDUCER 328 PRESSURE MANHOLE SHAFT - WITH ECCENTRIC 329 PRESSURE MANHOLE SHAFT 914 mm (361 WITHOUT REDUCER 630 610 mm (24') MANHOLE FRAME AND COVER 633 914 mm (361) MANHOLE FRAME AND COVER 635 STEEL STEP 636 POLYPROPYLENE PLASTIC STEP AMERICAN PUBLIC WORK$ ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 32METRIC 0-1 SHEET40F4 MANHOLE PIPE TO PIPE MAIN LINE ID=900 mm 36" OR LARGER NOTES: 1. WHERE THE BASIN IS TO BE CONSTRUCTED WITHIN THE LIMITS OF EXISTING OR PROPOSED SIDEWALK OR IS CONTIGUOUS TO SUCH SIDEWALK. THE TOP SLAB OF THE BASIN MAY BE POURED EITHER MONOLITHIC WITH THE SIDEWALK OR SEPARATELY, USING THE SAME CLASS OF CONCRETE AS IN THE BASIN. WHEN POURED MONOLITHICALLY. THE SIDEWALK SHALL BE PROVIDED WITH A WEAKENED PLANE OR A 25 mm(1') DEEP SAWCUT CONTINUOUSLY AROUND THE EXTERNAL PERIMETER OF THE CATCH BASIN WALLS. INCLUDING ACROSS THE FULL WIDTH OF THE SIDEWALK. SURFACE OF ALL EXPOSED CONCRETE SHALL CONFORM IN SLOPE, GRADE. COLOR. FINISH. AND SCORING TO EXISTING OR PROPOSED CURB AND WALK ADJACENT TO THE BASIN. 2. ALL CURVED CONCRETE SURFACES SHALL BE FORMED BY CURVED FORMS. AND SHALL NOT BE SHAPED BY PLASTERING. 3. FLOOR OF BASIN SHALL BE GIVEN A STEEL TROWEL FINISH AND SHALL HAVE A LONGITUDINAL AN A D LATERAL SLOPE OF i: 12 MINIMUM AN E: 3 MAXIMUM, EXCEPT WHERE THE GUTTER GRADE EXCEEDS 8 PERCENT. IN WHICH CASE THE LONGITUDINAL SLOPE OF THE FLOOR SHALL BE THE SAME AS THE GUTTER GRADE. SLOPE FLOOR FROM ALL DIRECTIONS TO THE OUTLET. 4. DIMENSIONS: B = 970 mm(3'-21) V = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF THE CATCH BASIN AT THE OUTLET = 1.35 m(4.51). VU = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT AT THE UPSTREAM END OF THE BASIN. AND SHALL BE DETERMINED BY THE REQUIREMENTS OF NOTE 3, BUT SHALL NOT BE LESS THAN CURB FACE PLUS 300 mm()2'). .V1 = THE DIFFERENCE IN ELEVATION BETWEEN THE TOP OF THE CURB AND THE INVERT OF THE INLET. NOTED ON THE PROJECT PLANS. H NO ON THE PROJECT PLANS. W = NOTED ON THE PROJECT PLANS. A THE ANGLE. IN DEGREES. INTERCEPTED BY THE CENTERLINE OF THE CONNECTOR PIPE AND THE CATCH BASIN WALL TO WHICH THE CONNECTOR PIPE IS ATTACHED. 5. PLACE CONNECTOR PIPES AS INDICATED ON THE PROJECT PLANS. UNLESS OTHERWISE SPECI- FIED. THE CONNECTOR PIPE SHALL BE LOCATED AT THE DOWNSTREAM END OF THE BASIN. WHERE THE CONNECTOR PIPE IS SHOWN AT A CORNER. THE CENTERLINE OF THE PIPE SHALL INTERSECT THE INSIDE CORNER OF THE BASIN. THE PIPE MAY BE CUT AND TRIMMED AT A SKEW NECESSARY TO INSURE MINIMUM 80 mm(3') PIPE EMBEDMENT, ALL AROUND. WITHIN THE CATCH BASIN WALL. AND 75 mm(3') RADIUS OF ROUNDING OF STRUCTURE CONCRETE. ALL AROUND. ADJACENT TO PIPE ENDS. A MONOLITHIC CATCH BASIN CONNECTION SHALL BE USED TO JOIN THE CONNECTOR PIPE TO THE CATCH BASIN WHENEVER ANGLE 'A• IS LESS THAN 70 DEGREES OR GREATER THAN 110 DEGREES, OR WHENEVER THE CONNECTOR PIPE IS LOCATED IN A CORNER. THE OPTIONAL USE OF A MONOLITHIC CATCH BASIN CONNECTION IN ANY CASE IS PERMITTED. MONOLITHIC CATCH BASIN CONNECTIONS MAY BE CONSTRUCTED TO AVOID CUT- TING STANDARD LENGTHS OF PIPE. 6. STEPS SHALL BE LOCATED AS SHOWN. IF THE CONNECTOR PIPE INTERFERES WITH THE STEPS. THEY SHALL BE LOCATED AT THE CENTERLINE OF THE DOWNSTREAM END WALL. STEPS SHALL BE SPACED 300 mm(12-) APART. THE TOP STEP SHALL BE 175 mm(T) BELOW THE TOP TO THE MANHOLE AND PROJECT 65 mm(2-1/21. ALL OTHER STEPS SHALL PROJECT 130 mm(5'). 7. DOWELS ARE REQUIRED AT EACH CORNER AND AT 2 m(7') ON CENTER (MAXIMUM) ALONG THE BACKWALL. 8. THE FOLLOWING STANDARD PLANS ARE INCORPORATED HEREIN: 308 MONOLITHIC CATCH BASIN CONNECTION 309 CATCH BASIN REINFORCEMENT 310 CATCH BASIN FACE PLATE ASSEMBLY AND PROTECTION BAR 312 CATCH BASIN MANHOLE FRAME AND COVER 633 STEEL STEP 636 POLYPROPYLENE PLASTIC STEP 9. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACT EQUAL VALUES. IF METRIC VALUES ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES, EXCEPT REINFORCING BARS SIZES IN ENGLISH UNITS MAY BE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED. ALL VALUES USED FOR CONSTRUCTION SHALL BE ENGLISH UNITS. AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER STANDARD PLAN 300 - 2 LOCAL DEPRESSIONS CURD OPENING CATCH BASIN SHEET 2 OF 2 DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. ui N PROMULGATED BY THE LOCAL DEPRESSIONS W CURB OPEN E -4CATCH Iii BAS SHEET t OF 4 USE WITH STANDARD s . G(FICAT}ONS FOR PUBLIC WORKS CONSTRUCTION CURBS POINT A---" 450m (1.59 9 POINT E g 2 'DIRECTION OF FLOW PLAN 132 z N K WD --- -- �! POINT A POINT B POINT C FLOW LINE PROFILE CASE A N L WD of lg CURB OPENING i xCA S) BASIN ( �3zc 02 ( I I I 4.1 CURB -' . POINT A\ -POINT B POINT C �4 J POINT E _- c POINT F La `-POINT G ----DIRECTION OF FLOW L -POINT D LINE CURB a GUTTER t �m 0 V �_ Ll CURB p & _aUTI&R ) u. DIRECTION OF RAWP -.. I •• �PUlnF G , DIRECTION Of FLOW � m N L WpL DN L S- _---- POINT A POINT D POINT B POINT C FLOW LINE PROFILE +tow LINE CASE B 25 m (11 150 mm (61 25 mm (11 150 mm (6') 25 mm (11 ----'M I- i M_ 1) -- 1- moi '--M,G,OR VAR. (1.51 50 mm I) -VAR. ( I �.nR. (2.1 CURB 1-�- RIDG FACE + H '�� rLLEY _, VALLEY. CIO- ° eco o Z-11-. a _j CIO SECTION A -A SECTION B -B SECTION G -G AMERICAN PUBLIC WORKS ASSOCIATION - SOUTHERN CALIFORNIA CHAPTER PROMULGATED BY THE LOCAL DEPRESSIONS STANDARD PLAN PUBLIC REENBOe STANDARDS INC., GREENBOOK COMMITTEE 1984 - AT CATCH BASINS RIC 313 -1 REV. ,99e SHEET t OF 4 USE WITH STANDARD s . G(FICAT}ONS FOR PUBLIC WORKS CONSTRUCTION NOTE: 1. ALL EXPOSED EDGES SHALL BE ROUNDED TO A 15 mm (HALF INCH) RADIUS. 2. THE CURB FACE AT POINTS A AND D SHALL BE THE NORMAL CURB FACE OF THE ADJACENT CURB. THE C C URB FACE AT POINTS B ANDS C HALL BE THE NORMAL CURB FACE OF THE ADJACENT CURB PLUS H (SEE APPLICABLE CATCH BASIN STANDARD PLAN). 3. IN EXISTING STREETS WHERE NO PAVEMENT REMODELING IS INDICATED, THE ELEVATION OF THE OUTER EDGE OF THE LOCAL DEPRESSION SHALL MEET tHE FINISHED STREET SURFACE. 4. IN NEW STREETS, OR IN EXISTING STREETS WHERE (PAVEMENT REMODELING IS INDICATED: THE ELEVATIONS OF POINTS F AND G SHALL BE SET H1 HIGHER THAN THE GUTTER FLOW LINE ELEVATIONS AT POINTS A AND D, RESPECTIVELY. THE ELEVATIONS OF POINTS P AND R SHALL BE SET Hz HIGHER THAN THE GUTTER FLOW LINE ELEVATIONS AT POINTS B AND C, RESPECTIVELY:. THE ELEVATION OF POINT S SHALL BE SET H2 HIGHER THAN THE ELEVATION AT THE NEAREST GUTTER FLOW LINE. WHERE THERE IS N0 GUTTER ADJACENT TO THE LOCAL DEPRESSION, THE ELEVATION OF -INT` E SHALL BE SET HS HIGHER• THAN THE ELEVATION AT THE NEAREST TOE OF CURB. 5. DIMENSIONS: H = NOTED ON THE PROJECT PLANS. H1 - NOTED ON THE PROJECT PLANS. H. - NOTED ON THE PROJECT PLANS. H3 - NOTED ON THE PROJECT PLANS. G - 600 mm (2 Feet) K - 1.5 m (5 Feet) L - 1.8 m (6' Feet) M - 1.2 m (4 ' Feat) N - 1.5 m (5 Feet) WD - CATCH BASIN W FOR ONE. CATCH BASIN OR DISTANCE BETWEEN EXTREME END WALLS FOR MUTIPLE CATCH BASINS. THE THICKNESS OF THE LOCAL DEPRESSION SHALL BE 200 mm (8 INCHES). 6. DIMENSIONS SHOWN ON THIS PLAN FOR METRIC AND ENGLISH UNITS ARE NOT EXACTLY EQUAL VALUES. IF METRIC UNITS ARE USED, ALL VALUES USED FOR CONSTRUCTION SHALL BE METRIC VALUES, EXCEPT REINFORCING BAR SIZES IN ENGLISH UNITS MAYBE SUBSTITUTED FOR METRIC BAR SIZES. IF ENGLISH UNITS ARE USED, ALL VALUES USED FOR 'CONSTRUCTION SHALL BE ENGLISH VALUES. AMERICAN RUBLIO.WIORKS ASSOCIATION:- SOUTH_ERN CALtFpRNIA CHAPTER STANDARD PIAN METRIC 313-1 FOCAL DEPRESSIONS AT CATCH BASINS SHEET 4 0P 4 r• Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA IN THE OFFICOF MADOLERED AND ASSOCIAT SE INC. S TORM DRA IN I MPRO VEMEN T PLA NS ANC OCUPHONA-13tt 107 DRAWN BY - SCALE: MILLER AVE./BEECH AVE. SAS SHAWN RANCHO CLIC CA 91730 DESIGNED BY: DATE: LP MJ STANDARD AND DETAILS NOV 20a4-1-�03 ate : 1,0 T,b3 CHECKED BY: PPRIXD BY: DRAWING NO.: 7 ) R.C.E. 62183 EXP. 0-30-06A. T.S./ • b /'�- Z a • 3448 8 ITY ENGINEER R.C.E. 51152 DATE J:1692-17221storm1sd07.dwg, 1 2/1 8/2003 03:59:02 PM, MG