HomeMy WebLinkAbout3448-1I ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE
CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN
BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS
OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL
IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR
TO IMPLEMENTING DETOURS.
5 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUN17Y DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY 1411THIN THE CITY LIMITS. CALL (909) 350-7610.
6 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER
TRAFFIC CONTROL DEVICES AT ALL TIMES.
8 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5
FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9 THE MIALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED
BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT
10 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
11 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND
ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO.
THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS
BEFORE EXCAVATION.
12 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC
WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES
SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES,
13 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR
VALVE OPERATION AND WATER REQUIREMENTS.
14 STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR
TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
16 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS
WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT
TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR.
SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED.
THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO
MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
18 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES, A
MINIMUM 72 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS
AND EMERGENCY VEHICLES.
19 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
20 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED
ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT
PRIOR WRITTEN APPROVAL,
21 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED
DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS
OBTAINED.
23 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
24 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING
CONCRETE.
25 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY
ENGINEER.
26 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND
LOCATION OF CONNECTIONS. CIT)` APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY
CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
27 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY
28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
3O APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
31 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY
THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
32 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES,
AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
33 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
34 MINIMUM D -LOAD FOR STORM DRAIN PIPE IS 1350.
MILLER AVENUE/ BEECH AVENUE STORM DRAIN
FROM STA. 10+00.00 TO STA. 4e+91.21
CITY OF FONTANA
1:1 SLOPE OR GREATER
OR ADEQUATE SHORING
907. COMPACTED
NATIVE BACKFILL
3" MAX. SIZE -'
GRANULAR BEDDING FROM
SELECTED TRENCH SIDE
MATERIAL (1 " MAX. SIZE).
i
U S9k
5 � r
11N.
IAX.
'D'
STORM DRAIN PIPE 0.6 -
GRANULAR BEDD/NG FROM SELECTED
TRENCH .SITE MATERIAL FOR PIPE
10' OR GREATER /N DEPTH USE
1/2 CRUSHED STONE BEDDING.
RCP TRENCH DETAIL
NOT TO SCALE
mtm
1. TRENCH WIDTH SHALL BE CONTROLLED
TO TOP OF PIPE ZONE.
2, TRENCH DEPTHS OF GREATER THAN 5'
SHALL HAVE ADEQUATE SHORING.
3, CLASS Il AGG. BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
N
COMPACTION SHALL BE 957. IN ALL
ZONES UNLESS OTHERWISE SPECIFIED,
TRENCH STABILITY SHALL CONFORM
TO CAL -OSHA REQUIREMENTS.
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES
SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO
THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE
SHOWN ON THESE PLANS, THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS, THE
CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE
UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE
DRAWINGS,
THE CONTRACTOR AGREES THAT HE SHALL_ ASSUME SOLE AND COMPLETE RESPONSIBIL17Y
FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER
HARMLESS FROM ANY AND ALL LIABILITY; REAL OR ALLEGED IN CONNE-CTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING
FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL_ REPORT
ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK.
STORM DRAIN LINE
(SEE PLAN FOR PIPE SIZE) (TYP )
DETAIL '""
(TYPICAL WATER/STORM DRAIN UNDERCROSSING DETAIL)
NOT TO SCALE
wiliff,` o 04
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5467
50. CALIFORNIA GAS COMPANY
COMCAST (CABLE TV)
ATTN, ALAN KESELOFF
ATTN: JACK HAYES
16231 VALLEY BLVD,
1205 DUPONT AVENUE FONTANA,
FONTANA, CA. 92335
ONTARIO, CA. 91761
(909) .335-7781
(909) 390-4736 EXT 3055
EMERGENCIES: (800) 427-2200
STORM DRAIN
SO. CALIFORNIA EDITON COMPANY
FONTANA WATER COMPANY
ATTN: JAIME AMESZCUA
ATTN: AL KROHN
(909) 357-6581
8440 NUEVO AVENUE
7951 REDWOOD AVENUE
FONTANA, CA 92335
FONTANA, CA. 92335
(909) 822-2201 EXT. 323
(909) 820-5598 UNDERGROUND
FAX. (909) 823®-5046
(909) 820-5137 TRANSMISSIONS
141A TER
(213) 637-1233 PIPELINES
CRAWFORD CANYON MUTUAL WATER CO.
(909) 357-6589 DISTRIBUTION
ATTN: BILL VANDERKIEFT, JR.
(800) 227-2600
(619) 868-6040
UNDERGROUND SERVICE ALERT
TELEPHONE
(800) 227-2600
EASEMENT
REV. REVISION DESCRIPTION DATE ENGR. G(n DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH INA DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE FLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
'T,P)
g
VICINITY
N. T S.
LEGEND.-
INSTALL 60" R.C.P., D LOAD PER PROFILE
FWC
FONTANA WATER COMPANY
TC
TOP OF CURB
FL
FLOW LINE (GUTTER)
INV
INVERT ELEVATION
STA
STATION
MH
MANHOLE
CB
CATCH BASIN
R/W
RIGHT-OF-WAY
CL
CENTERLINE
SD
STORM DRAIN
WA
WATER
SEW
SEWER
RCP
REINFORCED CONCRETE PIPE
VCP
VITRIFIED CLAY PIPE
13
CENTERLINE
-- - -®
RIGHT-OF-WAY
W
141A TER
S
SEWER
E
ELECTRIC
G
GAS
T
TELEPHONE
------
EASEMENT
NCH K- #360 BASIS OF BEARINGS -
C17 -Y OF FONTANA BENCH MARK j 360 THE BEARING OF N 00'22'40" E ALONG THI
A NAIL IN POLE j 1563704E CL OF BEECH AVE., AS SHOWN ON TR NO
AT SOUTHWEST CORNER OF LIME AVE. 13325-2, FILED IN BK. 216, PG. 13-18,
AND BASELINE AVE INCLUSIVE /N MAPS IN THE OFFICE OF THE
COUNTY RECORDER OF S.R.C., WAS USED
E A 1376.03 AS THE BASIS OF BEARING FOR THIS MAP.
INSTALL 60" R.C.P., D LOAD PER PROFILE
482
LF
INSTALL 48" R.C.P., D -LOAD PER PROFILE
1,988
LF
INSTALL 36" R.C.P., D -LOAD PER PROFILE
1,302
LF
INSTALL 3O" R.C.P., D -LOAD PER PROFILE
58
LF
INSTALL 24" R.C.P., D --LOAD PER PROFILE
118
LF
(�
CONST MANHOLE PIPE TO PIPE PER APWA STD. PLAN 322-1
1
EA
W1TH A BOLT DOWN LID
CONSTT, MANHOLE PIPE TO PIPE PER APWA STD. PLAN 320-1
13
EA
CONST JUNCTION STRUCTURE -PIPE TO PIPE APWA STD,
1
EA
PLAN 331-2
10
CONST. CONCRETE COLLAR FOR R.C.P. PER APWA STD. 380-2
3
EA
11
PROTECT EXISTING IMPROVEMENT IN PLACE
-
EA
12
CONST. CURB OPENING CATCH BASIN PER APWA STD. 300-2,
3
EA
W=PER PLAN
13
CONST PLUG WITH DOUBLE BRICK & MORTAR AND 1"± CONCRETE
3
EA
MORTAR AT THE END OF RCB / PIPE
%4
REMOVE EXSITT, STORM DRAIN STRUCTURE AND PIPE
5
EA /600 LF
75
CONST BLANKET PROTECTION PER A. P. W A. STD. PLAN 225-1
5
EA
16
FILL EX. STORM DRAIN PIPE WITH SAND, PLUG WTIH
3
EA
DOUBLE BRICK AND MORTAR AND ABANDON
17
SAWCUT, REMOVE AND REPLACE EX. AC PAVEMENT
46,570
SF
19
CONST LOCAL DRESSION PER APWA STD, 313-1
3
EA
20
GRIND 5' WIDE AND OVERLAY 0.1 ' MIN. PER DETAIL ON SHT. 2
5920
SF
21
ADJUST WATER VALVES TO GRADE
3
EA
22
ADJUST MANHOLE TO GRADE
1
EA
NCH K- #360 BASIS OF BEARINGS -
C17 -Y OF FONTANA BENCH MARK j 360 THE BEARING OF N 00'22'40" E ALONG THI
A NAIL IN POLE j 1563704E CL OF BEECH AVE., AS SHOWN ON TR NO
AT SOUTHWEST CORNER OF LIME AVE. 13325-2, FILED IN BK. 216, PG. 13-18,
AND BASELINE AVE INCLUSIVE /N MAPS IN THE OFFICE OF THE
COUNTY RECORDER OF S.R.C., WAS USED
E A 1376.03 AS THE BASIS OF BEARING FOR THIS MAP.