Loading...
HomeMy WebLinkAbout3413-31- /4 t 314" ww BASELINE AVENUE W es T3=3/4- 3/4 3 4 4" _ Q — __- - -t 62 t-1 1' �� 3 4 - — — — -- — -------------- — _` -- ----------------- ---- 1 \ � a :3 I _ 58 L L- ltWA11114 C.. ,,,.. .. p MAKE P.O.G. AT 1-1/2" WATER METER -VERIFY LOCATION $ 5 IN THE FIELD. APPX. P.5.1. I5 55- 1-1 23 I -I 22 11 111 16666 E 1-1 2• �1 4'•_ 77N _ T _ _ r ",ac�e,� /4. 3/4, �. �. �. /4. 3/`3/4. +. \ Ill pill pq _------------------- _— �— _�-=------ _�=— ------ ---� \ ---- -, —�--—,- - - - - - - --------y---- \ , v 43421) U21 - 0 26 IRRIGATION SPECIFICATIONS ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF FONTANA'5 LANDSCAPE DEVELOPMENT DESIGN INTENT 15 TO PROVIDE COMPLETE IRRIGATION COVERAGE TO ALL PLANTED AREAS, A5 STANDARD LANDSCAPE SPECIFICATION MANUAL FOR STREETSCAPES AND PARKS. FIELD CHANGE MAY OCCUR, CONTRACTOR 15 REQUIRED TO PROVIDE 100% COVERAGE TO ALL AREAS. IN NO INSTANCE SHALL HEAD 5PACING EXCEED 55% OF MANUFACTURER'S RECOMMENDED VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING ANY WORK, NOTIFY THE SPACING FOR COVERAGE. CONTRACTOR SHALL NOT KNOWINGLY INSTALL A SPRINKLER 5YSTEM LANDSCAPE ARCHITECT IMMEDIATELY IF ANY DISCREPANCY 15 FOUND. CONTRACTOR SHALL WITH IMPROPER COVERAGE, FAILURE TO NOTIFY THE LANDSCAPE ARCHITECT SHALL RESULT IN THOROUGHLY FAMILIARIZE HIMSELF HIT14 ALL SITE CONDITIONS PRIOR TO BIDDING OR THE CONTRACTOR REPAIRING/REPLACING SAID SYSTEM AT H15 OR HER EXPENSE. COMMENCING WORK. ALL SPRINKLER HEADS INSTALLED ADJACENT TO CURBS AND WALKS SHALL BE POP-UP TYPE. EXTREME CARE SHALL BE EXER015ED WHEN WORKING ADJACENT TO ANY STRUCTURE5 OR IN NO INSTANCE SHALL R15ER TYPE 5PRINKLER5 BE INSTALLED ADJACENT TO PEDESTRIAN UTILiTIE5. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES AND AS`S' REPAIRING ANY DAMAGES CAUSED BY HI5 NORK AT NO C05T TO THE OWNER. THE CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE IRRIGATION DESIGN 15 BASED ON AN AVAILABLE WATER PRE55URE OF 65 P.5.1. WITH A AND TO MINIMIZE OVER5PRAY ONTO WALKS, ROADWAY5 AND/OR BUILDIN55. THI5 SHALL MAXIMUM SYSTEM DEMAND OF 24 O.P.M. CONTRACTOR SHALL VERIFY DATA PRIOR TO INCLUDE SELECTING THE BEST DEGREE OF ARG TO FIT THE EXISTINO 51TE CONDITIONS AND COMMENCING WORK. WATER AVAILABILITY INFORMATION WA5 OBTAINED FROM FONTANA WATER TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM PRE55URE FOR EACH COMPANY. SYSTEM. MAKE POINT OF CONNECTION AT THE WATER METER A5 SHOWN ON THE PLANS AND RUN A 1-1/2" ALL PIPING AND WIRING UNDER PAVING 514ALL BE SLEEVED IN A SCH. 40 PVC PIPE, SIZE 5140 P.V.G. MAINLINE 16" DEEP TO AREAS WHERE VALVES ARE LOCATED. INSTALL A LINE A5 REQUIRED AND WITTY A MINIMUM COVER TO FINISHED PAVEMENT GRADE OF 24". SIZED GATE VALVE IN A ROUND PLASTIC BOX AT P.O.G. FOR EMERGENCY SHUT-OFF. ALL EQUIPMENT SHALL BE INSTALLED PER DETAILS, IN THE ABSENCE OF DETAILS, THE LANDSCAPE ARCHITECT SHALL BE RESPONSIBLE FOR THE INTERPRETATION OF THE INSTALLATION SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE TRADE. DRAWING5 SHOULD A QUE51`I0N ARISE. CONTRACTOR SHALL GUARANTEE ALL MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR PIPING 51 ON THE PLANS 15 E55ENTIALLY DIAGRAMMATIC, ROUTE PIPING AND LOCATE FROM DATE OF FINAL ACCEPTANCE BY THE OWNER. VALVES TO AVOID CONFLICT WITH STATIONARY ELEMENTS. WHEN VERTICAL 055TR1GTION5 (FIRE HYDRANTS, LIGHT5, TREES ETC) INTERFERE WITH THE SPRAY PATTERN OF THE HEADS, PROVIDE A COLOR GODED LAMINATED CONTROLLER CHART IN THE CONTROLLER 5HOHIN67 THE THE IRRIGATION CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM AT NO ADDITIONAL VALVES AND AREAS SERVED BY EACH VALVE. COST TO THE OWNER, BY INSTALLING A QUARTER OR HALF HEAD SPRINKLER ON EACH SIDE OF THE OBSTRUCTION 50 AS TO PROVIDE PROPER COVERAGE. LOCATE ALL VALVE5 AND BACKFLOW BEFORE BEGINNING CONSTRUCTION, THE CONTRACTOR MUST OBTAIN ALL NECESSARY PERMITS DEVICE IN SHRUB BEDS WHERE POSSIBLE. FROM THE CITY. WIRING FROM THE CONTROLLER TO THE VALVE5 5HALL BE DIRECT 13URIAL A.F.N, MINIMUM THE IRRIGATION 51 WILL BE TE5TED BY THE ONNER5 REPRESENTATIVE IN THE FIELD 14 GAUGE. PROVIDE A CONTINUOUS SPARE WIRES) TO VALVE(5) FURTHEST FROM THE BEFORE FINAL APPROVAL. CONTROLLER. LOOP WIRE INTO EACH VALVE BOX ALONG THE MAINLINE WITH A MIN. 30" EXPANSION COIL. SPARE WIRE IS TO 13E A DIFFERENT COLOR FROM OTHER CONTROL HIRE5. INSTALL ALL COMPONENTS PER CURRENT U.P.G. AND LOCAL CODES. LABEL WIRE 5PARE IN CONTROLLER. CONTRACTOR SHALL MAINTAIN A GLEAN AND SAFE WORKING ENVIRONMENT. DAY AND NIGHT PROVIDE CHECK VALVES AS NEEDED TO ELIMINATE ALL LOW HEAD DRAINAGE. BARRICADES MUST 13E PROVIDED FOR ALL OPEN TRENCHES. ALL EQUIPMENT SHALL BE AS L15TED IN THE LEGEND. SUBSTITUTIONS WILL NOT BE THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE UNDERGROUND SERVICE ALERT PERMITTED WITHOUT PRIOR APPROVAL OF THE LANDSCAPE ARCHITECT. AT I-600-422-4133 AT LEAST 46 HOURS PRIOR TO TRENCHING FOR EXACT UNDERGROUND UTILITY LOCATIONS. THE CONTRACTOR A55UME5 ALL RESPONSIBILITY FOR THE REPAIR OR CONTRACTOR SHALL PROVIDE COMPLETE AND ACCURATE RECORD DRAWINGS TO THE CITY UPON REPLACEMENT OF UNDERGROUND UTILITIES OR STRUCTURES M104 ARE DAMAGED DURING THE COMPLETION OF THE PROJECT. DRAWINGS SHALL INDICATE ANY CHANGES FROM THE ORIGINAL COURSE OF COMPLETING TH15 WORK. PLANS AND DIMENSIONS OF VALVES, QUICK COUPLERS, CONTROLLERS AND ALL OTHER EQUIPMENT FROM STATIONARY POINTS OF REFERENCE. SPECIFICATIONS FOUND IN THE CITY OF FONTANA 5TANDARD LANDSCAPE 5PECIFICATION5 SHALL TAKE PRECEDENCE AND SHALL BE FOLLOWED FOR THE INSTALLATION OF THE LANDSCAPE AND IRRIGATION SYSTEM. 0 0' 20' W. 60' 0 REFER TO SHEET 2 FOR IRRIGATION LEGEND REFER TO SHEET 6 FOR IRRIGATION CONSTRUCTION DETAILS i I i I 24 23 22 21 --T 1I� I I I it 11 I I I I III II I /4* Wd 3/4'I II 1 I p 1 4.� ll ! I 3/4' �. l \ 2" SLEEVE 4" SLEEVE I I I I I MA� —t— -----r- ■n