HomeMy WebLinkAbout3404-8ELECTfRiCAL ASI REvIATIONS 0 AT A AMPERES ABV ABOVE AF AMP FUSE OR AMP FRAME AFC AVAILABLE FAULT CURRENT (SYMMETRICAL) AFF. ABOVE FINISHED FLOOR ARCH. ARCHITECT AS AMP SWITCH AT AMP TRIP AUTO AUTOMATIC BKBD BACKBOARD C CONDUIT CB CiRCUiT BREAKER CKT CIRCUIT CLG. CEILING CLR CLEAR C.O. CONDUIT ONLY CONC. CONCRETE CONN. CONNECT OR CONNECTION CONT. CONTINUED/CONTINUATION C.W. COLD WATER D DEPTH DET. DETAIL DIA. DIAMETER DISC. DISCONNECT ON DOWN DWG DRAWING ELEC ELECTRIC OR ELECTRICAL ELEV ELEVATION EMERG. EMERGENCY EQUIP. EQUIPMENT EXIST. EXISTING EXT. EXTERIOR FDR FEEDER FIXT. FIXTURE FLA FULL LOAD AMPERES FLR FLOOR FLUOR FLUORESCENT GALV. GALVANIZED GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER GND GROUND H HIGH OR HEIGHT WORIZ. HORIZONTAL HP HORSEPOWER ATR HEATER HVAC HEATING, VENTILATING AND AiR CONDITIONING I.G. ISOLATED GROUND INCAND. INCANDESCENT IND. INDICATED NT. INTERIOR JB JUNCTION BOX KVA KILOVOLT AMPERES KW KILOWATT KWH KILOWATT HOUR L LENGTH LCL LONG CONTINUOUS LOAD LOC. LOCATION LTG LIGHTING MAX MAXIMUM MFR MANUFACTURER MN MINIMUM OR MINUTES MTD MOUNTED MTG MOUNTING MTG. NT. MOUNTING HEIGHT NA NOT APPLICABLE NF NON FUSIBLE N.L. NiGHT LIGHT NTS NOT TO SCALE P POLE PB PULLBOX P.C. PHOTOCELL PNL PANEL PWR. POWER RECEPT RECEPTACLE REQ'D REQUIRED RM ROOM SCHED. SCHEDULE SWT SHEET W. FT. SQUARE FEET STD. STANDARD SURF. SURFACE SW. SWITCH SWBD SWITCHBOARD SYS. SYSTEM TEL TELEPHONE TEMP. TEMPORARY OR TEMPERATURE TRANSF. TRANSFORMER TTB TELEPHONE TERMINAL BACKBOARD TYP TYPICAL Ufa. UNDERGROUND U.ON. UNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERES VD. VOLTAGE DROP VERT. VERTICAL W WATTS OR WiRE OR WIDE W/ WiTH W/O WITHOUT WP. WEATHERPROOF NOTE: NOT ALL ABBREVIATION ARE USED ON ALL PROJECTS ELECTRICAL SPECiFICATiONS A. GENERAL 1. SCOPE THE DRAWINGS AND THESE SPECIFICATIONS DESCRIBE THE SYSTEMS FURNISH ALL MATERIALS AND PERFORM ALL WORK REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. UNLESS SPECIFICALLY NOTED TO THE CONTRARY, FURNISH AND INSTALL ALL NEW MATERIAL AND EQUIPMENT AS REQUIRED TO PRODUCE A COMPLETE OPERATNG SYSTEM. 2. PERMITS AND CHARGES OBTAIN AND PAY FOR ALL NECESSARY CONSTRUCTION PERMITS, INSPECTION FEES, AND OTHER CHARGES BY AGENCIES HAVING JURiSDiCTiM 3. REGULATIONS AND CODES PROVIDE AND INSTALL ALL MATERIALS IN CONFORMANCE WITH THE 1999 NATIONAL ELECTRICAL CODE, CALIFORNIA ADMINISTRATIVE CODE TITLE 8, AND OTHER CODES AND REGULATIONS HAVING JURISDICTION. INSTALL ALL EQUIPMENT N ACCORDANCE WiTH THE REQUIREMENTS OF THE NSPECTNG AUTHORITY AND THE MANUFACTURERS RECOMMENDATIONS 4. VERIFYNG EXISTNG CONDITIONS BEFORE SUBMITTING BiD, BECOME THOROUGHLY FAMILIAR WITH ACTUAL EXISTING CONDITIONS AT THE PROJECT SITE. THE INTENT OF THE WORK iS SHOWN ON THE DRAWINGS AND DESCRIBED HEREINAFTER BY THE ACT OF SUMTTNG A BiD PROPOSAL FOR WORK, THE CONTRACTOR SHALL BE DEEMED TO NAVE MADE SUCH A STUDY AND EXAMINATION AND TO ACCEPT ALL CONDITIONS PRESENT AT THE SITE. NO REQUEST FOR ADDITIONAL PAYMENT SHALL BE CONSIDERED AS VALID, DUE TO FAILURE TO ALLOW FOR CONDITIONS WHICH MAY EXiST. 5. COORDINATION COORDINATE ALL WORK WiTH OTHER TRADES AND WITH THE UTILITY COMPANY. OBTAIN ALL DRAWINGS THAT WILL REQUIRE COORDINATION AND PROVIDE ALL ELECTRICAL CONNECTIONS REQUIRED WHETHER SHOWN ON ELECTRICAL DRAWINGS OR NOT. LOCATIONS OF ELECTRICAL EQUIPMENT, J -BOXES, AND CONDUIT RUNS SHOWN ON THE DRAWINGS ARE APPROXIMATE. FiELD VERIFY FOR EXACT LOCATIONS AND COORDINATE ALL WORK WITH THE OTHER DISCIPLINES TO AVOID CONFLICTS. THiS CONTRACTOR 15 TO PROVIDE ALL CONTRCIL WIRING, RELAYS, STARTERS, TiME SWITCHES CONDUITS, ETC. INDICATED THEREON AS BEING PROVIDED UNDER THE ELECTRICAL WORK 6. AS BUILT PROVIDE RECORD DRAWINGS TO THE OWNER WITH ALL CHANGES NOTED THEREON At THE COMPLETION OF THE PROJECT. RECORD DRAWINGS SHALL BE SIGNED AND DATED BY CONTRACTOR 1. GUARANTEE CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON ALL WORK AGAINST DEFECTS N WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR, EXCEPT FOR LIGHTWx FIXTURE LAMPS S SHOP DRAWNGS SUBMIT REQUIRED SHOP DRAWINGS FOR REVIEW UJITHN ONE WEEK OF BID AWARD. ALL EQUIPMENT TO BEAR U.L. LABEL OR TWAT OF ANOTHER ACCEPTABLE TESTING LABORATORY. SHOP DRAWINGS MUST BE STAMPED BY THE CONTRACTOR FOR CONFORMANCE PRIOR TO SUBMITTING. ALL EQUIPMENT WAS BEEN PRE -APPROVED BY OILIER AND SPECIFIED AS SUCH. NO SUBSTITUTIONS WILL BE ALLOWED. 9. CONTRACTOR BID CONTRACTOR'S BiD SHALL BE BASED ON ALL WORK SWO11N ON THE PLANS AND AS SPECIFIED. ALL PREMIUM TIME COSTS REQUIRED SMALL BE INCLUDED IN THE BID. THE CONTRACTOR $WALL BE RESPONSIBLE AT HIS OWN EXPENSE FOR ANY CHANGES RESULTING FROM ANY PROPOSED SUBSTITUTIONS WHICW AFFECT OTHER PARTS OF NIS OWN WORK OR THE WORK OF OTHER CONTRACTORS B: MATERIAL AND INSTALLATION ALL WORK AND MATERIAL SMALL CONFORM TO THE LATEST RULES OF TME GOVERNING ELECTRICAL CODE AND INSTALLATION SMALL BE OF THE LATEST NOUSTRY STANDARDS OF WORKMANSHIP. ALL MATERIALS SHALL BE NEW AND LiSTED BY UNDERWRITERS LABORATORY (UL, OR ANOTHER ACCEPTABLE INDEPENDENT TESTING LABORATORY. L CONDUITS CONDUITS SHALL BE EMT, RiGiD OR FLEXIBLE STEEL TYPE ABOVE GRADE AND SCHEDULE 40 PVC BELOW GRADE. FLEXIBLE STEEL CONDUIT SMALL BE MANUFACTURED N ACCORDANCE WiTH UL -1, USED ONLY FOR LIGHTING FIXTURE CONNECTION, SHORT MOTOR CONNECTION OR FOR THE EQUIPMENT REQUIRING VIBRATION) ISOLATION. LENGTH 15 LIMITED TO 12" MAXIMUM. A GROUND WiRE 15 REQUIRED IN ALL FLEXIBLE CONDUiT- CONCEAL ALL CONDUITS, UNLESS OTHERWISE NOTED. 2. WiRE_ AND CABLE IDENTIFICATION IDENTIFY BRANCH CIRCUITS WITH CORRESPONDING CiRCUIT DESIGNATION AT THE OVERCURRENT DEVICE, AT ALL SPLICES, AND N JUNCTION BOXES. MARK CiRCUIT DESIGNATION ON ALL JUNCTION BOX COVERS. CIRCUIT DESIGNATION MEANS PANEL DESIGNATION AND CiRCUiT NUMBER I.E. A -I USE PLASTIC COATED SELF -STICKING MARKERS SUCH AS THOMAS a BETTS E -Z CODE FOR IDENTIFICATION OF CONDUCTORS AND METAL EDGE BANDED PAPER TAGS ON PULL ROPES. 3. CONDUCTOR$ DELIVER ALL CONDUCTORS TO THE JOB SiTE N ORIGINAL UNBROKEN CARTON OR REEL, PROPERLY TAGGED WITH U.L. LABEL SiZE, TYPE, MANUFACTURER'S TRADE NAME AND THE DATE MANUFACTURED (MUST BE MANUFACTURED WITHN 6 MONTHS). PROVIDE COPPER CONDUCTORS. $12 AWG MINIMUM, UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROVIDE SOLID CONDUCTORS, 610 AWG AND SMALLER UNLESS OTHERWISE NOTED. PROVIDE STRANDED CONDUCTORS, 09 AWG AND LARGER UNLESS OTHERWISE NOTED. USE CONDUCTORS WiTH THHN/THWN -2, 90'C. RATED, 600 VOLTS NSULATiON UNLESS OTHERWISE NOTED. INSTALLATION OF 600 VOLT CONDUCTORS: CONDUCTORS SMALL BE CONTNUOUS BETWEEN OUTLETS OR JUNCTION BOXES. MAKE SPLICES N OUTLET BOXES, PULLBOXE5 OR PANELBOARD GUTTERS. DO NOT SPLICE PANELBOARD FEEDERS. 4. LIGHTING FIXTURES FURNISH AND INSTALL L16WTNG FIXTURES OF THE TYPE SPECIFIED ON THE DRAWNGS a PROVIDE APPROPRIATE MOUNTNG HARDWARE. MO SUBSTITUTIONS ALLOWED) 5. SERVICE EQUIP. / PANELBOARDS PANELBOARDS SHALL BE FACTORY -ASSEMBLED, SURFACE MOUNTED, AS SHOWN ON DWGS. PROVIDE TERMINAL LUGS ON MAN BREAKERS RATED FOR USE WITH COPPER CONDUCTORS, FULL-SIZE NEUTRAL BUS AMC) BOLT -ON CiRCUiT BREAKERS RATED TO EXCEED THE AVAILABLE SHORT CiRCUIT CURRENT. PROVIDE PANEL IDENTIFICATION NAMEPLATE AND TYPEWRITTEN LiST OF CIRCUITS iN THE DIRECTORY FRAME CLEARLY INDICATING THE LOADS SERVED. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE -0 CO. TYPE NQOD WITH BOLT -ON BREAKERS. SECURE SURFACE MOUNTED PANELBOARD TO WALL (5). PROVIDE A PRE -CAST CONCRETE PAD AND VAULT INCLUDING GROUNIDING AS REQUIRED BY SERVING UTILITY COMPANY. COORDINATE LOCATION AND SERVICE CONDUIT REQUIREMENTS. PAD / VAULT TO BE BROOKS, OU"ET OR SHAW. PROVIDE MAIN SWITCHBOARD AS SHOWN ON PLAN, ELEVATION AND ONE LiNE DIAGRAM COORDINATE UNDERGROUND PULL SECTION!. MAIN DISCONNECT ANY METERING UT14 THE SERVING UTILITY COMPANY. SWITCHBOARD SMALL BE SQUARE -D, CLASS 2110. MISCELLANEOUS DISCONNECT SWITCHES, MOTOR STARTERS, ETC. SMALL BE SPECIFICATION GRADE BY SQUARE -D. 6. NAMEPLATE PROVIDE NAMEPLATES ON ALL PANELBOARDS, POWER DISTRIBUTION UNITS, DISCONNECTS, AND ALL ELECTRICAL EQUIPMENT IDENTIFIED BY NAME AS SHOWN N PLANS. NAMEPLATES SMALL BE LAMINATED BLACK AND WHITE BAKELITE WITH CHARACTERS CUT THROUGH THE BLACK BAKELITE (3/16' HiGH LETTERS MINIMUM). ATTACH TO EQUIPMENT WITH SCREWS. LIGHTING FIXTURE SCHEDULE LIGHTING FIXTURE SCHEDULE GENERAL NOTES: ALL LIGWT FIXTURES SHALL BE FURNISHED AND INSTALLED COMPLETE WITH ALL NECESSARY HARDWARE FITTINGS AND LAMPS. X PROVIDE TAMPER PROOF SCREW DRIVER BY MANUFACTURER. SIE X PROVIDE SEPARATE CIRCUIT WIRING FOR EACH FIXTURE. (480V -T* a 211V-10) ELECTRICAL 5YM50LS GENERAL SYMBOLS NOTES: 1. MOUNTING HEIGHTS NOTED ARE DISTANCES MEASURED FROM THE DEVICE CENTERLINE TO TWE FINISHED FLOOR OR FINISHED GRADE, UNLESS OTHERWISE NOTED. O 2. AN OVAL WITH A NUMBER INSIDE REFERS TO A (REFERENCE NOTE ON THE DRAWING WHERE iT 15 INDICATED. SURFACE MOUNTED SWITCHES WiTH MOUNTING HEIGHT 448' (WAN-) ❑' INPUT LAMPS NOTED WITH 'NF' MANUFACTURER MOTOR RATED TOGGLE DiSC24NECT SWITCH TYPE DESCRIPTION ® MOUNTING REMARKS NO. WATTS TYPE PROTECTION UNLESS OTHERWISE NOTED POWER AND WIRING DISTRIBUTION VA BRANCH CIRCUIT PANELBOARD 4 CATALOG NO. CONDUIT RUN CONCEALED N CEILING OR WALL (SEE SPECIAL SYSTEMS O BASKETBALL COURT FIXTURE 1050 1 1000 MH POLE' HUBBELL nASB C-1O00MN-Dd-48®-SSP530-1-A-DB SEE DWG. 5 480V -10 LIGHTING HASH MARKS NDICATE THE QUANTITY OF CONDUCTORS REQUIRED. UNLESS OTHERWISE NOTED, NO HASH MARKS NDICATE 2 012 AWG (010 AUKS CONDUCTORS INDICATED). WHERE A NUMBER iS NOT INDICATED, THE ES ONOT USED CONDUCTOR SIZE MIN. RACEWAY SIZE 12 10 8 ONE-HALF INCH 1 to 4• 1 to 4 ------ THREE-QUARTER NCH 5 to 8 5 to 6 Ito 3 LOT LIGHTING ONE NCM 9 to 13 1 to ll 4 to 5 -QUANTITY OF CONDUCTORS AS INDICATED (TYR) 2LA-1,3,541 INDICATES A HOME" TO PANEL 2LA, CIRCUITS 1-3-5 WITH SHARED KIM LIGHTING 'CCS' SERIES ARM MOUNTED SEE DWG. 2 OPARKING POLES (FIXTURES) 430 1 400 MN POLE ON 19'-6' "KRS20-4180 POLE. 480V -10 E5 CONDUIT BEND DOWN AWAY FROM OBSERVER . PARKING LOT LIGHTING KIM LIGHTNG 'CCS' SERIES, POLE TOP SEE 2 CI POLES (FIXTURES) 430 1 400 POLE MOUNTING. POLE TO BE 19'-6' %"20-4180. 480V -10 ES POST TOP LIGHTING:SPAULDiNG LIGHTING NC_ "VA-150-HPS, SEE SEE i O FIXTURE VANDAL 113 1 150 NPS POLE TOP WITH 12 RAPVA POLE, 41.2 DIA. 150 x 12'-0" WIGH, AD NTAMPER RESISTANT METAL FIN TYPE BASE COVER PLATE 480V -14, E5 DI SAME AS "D" WITH T 150 POLE 0-H, a SPAULDING LIGHTING INC. 'VA -15 P5 KIM LiGHTINdCs 'Yo150R-10@-HPS-HL"14-21'1 WiTH 12 SEE i ADDITIONAL FLOOD LIGHT 300 HPS 1 .DIA x ., iGH PVA POLE, /2FIXTURE )K )K 1 100 TAMPER RESISTANTETAL ASE COVE PLATE E5 211 a 480V -10 O GRADE MOUNTED FLUORESCENT FIXTURE FOR 35 1 32 Ts FLUOR GRADES LiTELiNE SERIES SEE 4 Eg MONUMENT SiGN 'CFS' - 35 -28 -FL -120 -A15 -N-56 120V O4' FLUORESCENT (2) LAMP STRiPLIGHT WiTH WiREGUARD 30 1 32 F32T8 SP35 SURFACE COLUMBIA 0CS4-232-EBWLH 120V MOISTURE AND 14M SURFACE VANDAL RESISTANT )K OENCLOSED, DUST RESISTANT FIXTURE W/ 60 1 50 CLEAR CEILING / WOLCOR "HSC88-505-120v. APF -TX PRISMATIC LENS WALL 120V J O 5' x 48' FLUORESCENT FIXTURE WITH J81 POLY -CARBONATE F32T8 SURFACE KENALL VANDAL RESISTANT 120V DIFFUSER 30 1 32 SP35 "SH5-48-i-32-i-120V. J$1-9500 Jl 5' x 48' FLUORESCENT FIXTURE WITH POLY -CARBONATE F32T8 SURFACE KENALL VANDAL RESISTANT PROVIDE EMER3. BATTERY PACK WHERE INDICATED .181 60 2 32 DIFFUSER SP35 98145-48-2-32-1-120V .181-9500. ON PLAN. 12OV. LIGHTING FIXTURE SCHEDULE GENERAL NOTES: ALL LIGWT FIXTURES SHALL BE FURNISHED AND INSTALLED COMPLETE WITH ALL NECESSARY HARDWARE FITTINGS AND LAMPS. X PROVIDE TAMPER PROOF SCREW DRIVER BY MANUFACTURER. SIE X PROVIDE SEPARATE CIRCUIT WIRING FOR EACH FIXTURE. (480V -T* a 211V-10) ELECTRICAL 5YM50LS GENERAL SYMBOLS NOTES: 1. MOUNTING HEIGHTS NOTED ARE DISTANCES MEASURED FROM THE DEVICE CENTERLINE TO TWE FINISHED FLOOR OR FINISHED GRADE, UNLESS OTHERWISE NOTED. O 2. AN OVAL WITH A NUMBER INSIDE REFERS TO A (REFERENCE NOTE ON THE DRAWING WHERE iT 15 INDICATED. SURFACE MOUNTED SWITCHES WiTH MOUNTING HEIGHT 448' (WAN-) ❑' DISCONNECT SWITCH WITH OVERCURRENT PROTECTION UNLESS OTHERWISE ROSENA PARK - EAST 10-A RK CTR. LOT W NOTED WITH 'NF' S T MOTOR RATED TOGGLE DiSC24NECT SWITCH S M MANUAL MOTOR STARTER ® MAGNETIC MOTOR STARTER COMBINATION MOTOR STARTER -DISCONNECT DEVICE, WITH OVERCURRENT PROTECTION UNLESS OTHERWISE NOTED POWER AND WIRING DISTRIBUTION BRANCH CIRCUIT PANELBOARD CONDUIT RUN CONCEALED N CEILING OR WALL (SEE SPECIAL SYSTEMS r AND DEFINITION SYMBOLS FOR RACEWAY CODING) -- -- CONDUIT RUN EXPOSED — —NI CONDUIT RUN N OR BELOW FLOOR SLAB OR GRADE 010 INDICATES AN EQUIPMENT GROUND CONDUCTOR ,T_ HASH MARKS NDICATE THE QUANTITY OF CONDUCTORS REQUIRED. UNLESS OTHERWISE NOTED, NO HASH MARKS NDICATE 2 012 AWG (010 AUKS CONDUCTORS INDICATED). WHERE A NUMBER iS NOT INDICATED, THE CONDUCTORS ARE 012 AUG (MN). CONDUIT SiZE SMALL BE AS FOLLOWS: CONDUCTOR SIZE MIN. RACEWAY SIZE 12 10 8 ONE-HALF INCH 1 to 4• 1 to 4 ------ THREE-QUARTER NCH 5 to 8 5 to 6 Ito 3 ONE NCM 9 to 13 1 to ll 4 to 5 -QUANTITY OF CONDUCTORS AS INDICATED (TYR) 2LA-1,3,541 INDICATES A HOME" TO PANEL 2LA, CIRCUITS 1-3-5 WITH SHARED NEUTRAL AND CiRCUiT 1 WITH DEDICATED NEUTRAL FLEXIBLE CONDUIT n n CABLE OR CORD �YJC� ARROW INDICATES A PLUG -N CONNECTION ----0 CONDUIT BEND UP TOWARD OBSERVER —® CONDUIT BEND DOWN AWAY FROM OBSERVER . SPECIAL SYSTEMS RACEWAY CODING T TELEPHONE GENERAL LIGHTING INDICATES A REFERENCE TO THE LIGHTING FIXTURE SCHEDULE: TYPE 'A' FiXTURE INDICATED. ® SURFACE MOUNTED FLUORESCENT FiXTURE. D FIXTURES WiTH EMERGENCY BATTERY PACK. F-0 --j SURFACE MOUNTED FLUORESCENT STRIP FIXTURE a WALL MOUNTED LIGHT FIXTURE. D PARK WALKWAY LIGHTING FIXTURE, POLE MOUNTED (SHADED INDICATES SECURITY FIXTURE). M.0 ❑0 PARKING LOT LIGHTING FIXTURE, POLE MOUNTED (SHADED INDICATES SECURITY FiXTURE). ❑ SURFACE CEILING MOUNTED LiGHT r-wuRE. t y GRADE MOUNTED FLOOD LIGHT FIXTURE. Q -O BASKETBALL COURT LIGHTING FIXTURE, POLE MOUNTED. RECESSED SWITCHES WITH MOUNTING HEIGHTS 448' (U.ON.J $a SINGLE POLE $WITCH, 20A,120 VAC CEILING MOUNTED OCCUPANCY SENSOR FOR CONTROL OF LIGHTS. ® NOViTAS 'DESIGNER SERIES OR EQUAL BY WATT STOPPER PROVIDE POWER PACK AT LIGHT FIXTURE OUTLET BOX. SUBSCRIPT LETTERS NEXT TO THE ABOVE SYMBOLS INDICATES DEVICE CONTROLLED BY THE SWITCH WITH THE SAME SUBSCRIPT LETTER WHERE MULTIPLE SUBSCRIPT LETTERS APPEAR EACH SUBSCRIPT DESIGNATES ONE SWiTCW OF THE TYPE INDICATED. SINGLE LINE SYMBOLS ® UTILITY COMPANY METERNG AND TEST BLOCKS AS REQUIRED BY THE SERVING AGENCY DISTRIBUTION TRANSFORMER OR INSTRUMENTATION POTENTIAL rYTY TRANSFORMER n CiRCUIT BREAKER CIRCUIT BREAKER WITH GROUND FAULT PROTECTION GROUND SEE SINGLE LINE DIAGRAM, BONDS TO GROUND ELECTRODE SHALL BE BY EXOTHERMIC WELDS. MOTOR (NUMBER INSIDE SYMBOL DESIGNATES W OF MOTOR) OUTLETS MOUNTING HEIGHTS AS INDICATED ON SYMBOLS LIST, UNLESS OTHERWISE NOTED BY SPECIFIC LOCATION N PLANS TYPICAL OUTLET CODING Q CIRCLE OR DIAMOND DESIGNATES OUTLET BOX, CEILING MOUNTED 4 BRACKET DESIGNATES OUTLET BOX, WALL MOUNTED AT 418' UNLESS OTHERWISE NOTED (Q4 DOUBLE DUPLEX (QUAD) RECEPTACLE 418" AFF. NEMA 5-20R (LION. i DOUBLE DUPLEX (QUAD) RECEPTACLE: NEMA 5-20R (UAN-) MOUNT +6" ABOVE COUNTER SPLASH ®I TELEPHONE OUTLET NOTE: NOT ALL SYMBOLS ARE USED ON ALL PROJECTS. CITY OF FONTANA, CALIFORNIA DRAWN BY EF: ROSENA PARK - EAST 10-A RK CTR. LOT W SCALE NONE DESIGNED BY. RF. DATE:- ATE:RF: 09/02/03 CHECKED BY: Ll B CA— ). 1 CITY ENCaR�tE R.C.E 51152 D� DATE 1213VO3 DWG. NOz 34Q4 1 V1 GENERAL NOTES i. ALL DEVICES INSTALLED OUTSIDE OR IN DAMP LOCATIONS SHALL BE APPROVED WEATHERPROOF. 2. THE CONTRACTOR SHALL PROVIDE SUPPORT FOR ALL FIXTURES AND ELECTRICAL EQUIPMENT TO COMPLY WITH THE SEISMIC REQUIREMENTS OF THE UNIFORM BUILDING CODE AND ALL LOCAL ORDINANCES. 3. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, THE ELECTRICAL DRAWINGS ARE E55ENTIALLY DIAGRAMMATIC. THE SiZE AND LOCATION OF EQUIPMENT iS SHOWN TO SCALE WHEREVER POSSIBLE. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS DATA INFORMATION AS INDICATED ON THE DRAWINGS AND N THE SPECIFICATIONS SECTIONS WHERE ELECTRICAL WORK INTERFACES WITH OTHER TRADES. 4. ALL UNDERGROUND BONDING CONDUCTORS SHALL BE COPPER. 5. ALL SYMBOLS AND ABBREVIATION$ SHOWN MAY NOT BE APPLICABLE TO THIS PROJECT. INSTALL EQUIPMENT GREEN GROUNDING CONDUCTOR, SiZED PER N.E.C. 250-122 N ALL CONDUITS. GROUND WIRES ARE NOT SHOWN ON DRAWINGS. MEOHANlCAt- �L�CTF!"OAL CANS ULT"N G31 Sinha & Keyfauver Engineering, Inc. 421 EAST HUNTINGTON DRIVE MONROVIA, CALIFORNIA 91016 626-930-1383 Fax: 626-930-1385 Job No: 99100 10979 �( E p. 6/30/2007 CAL�� DATE SIGNED: 11-6-2003 SIL IZp04,- LANDSCAPE ARCHITECTURE SITE PLANNING wawftftlm ftft 4 O CA 9it30 Floc 04%M ��''aa''y�yy� Cliff, awsWSN�w MWeto LA SEAL N' PROJECT / CLIENT L Q N 0 L0 O O • 'd � O `' m Noe L t0 CU E Y C C.� v C U I tti C w C O UL O U SHEET TITLE _1 i r Al� DRAWN BY R.R. DATE 09/02/03 SCALE AS NOTED I JOB NUMBER 0143-4 SHEET NUMBER E-1 OF 8 SHTS. 26