HomeMy WebLinkAbout3404-8ELECTfRiCAL ASI REvIATIONS
0
AT
A
AMPERES
ABV
ABOVE
AF
AMP FUSE OR AMP FRAME
AFC
AVAILABLE FAULT CURRENT (SYMMETRICAL)
AFF.
ABOVE FINISHED FLOOR
ARCH.
ARCHITECT
AS
AMP SWITCH
AT
AMP TRIP
AUTO
AUTOMATIC
BKBD
BACKBOARD
C
CONDUIT
CB
CiRCUiT BREAKER
CKT
CIRCUIT
CLG.
CEILING
CLR
CLEAR
C.O.
CONDUIT ONLY
CONC.
CONCRETE
CONN.
CONNECT OR CONNECTION
CONT.
CONTINUED/CONTINUATION
C.W.
COLD WATER
D
DEPTH
DET.
DETAIL
DIA.
DIAMETER
DISC.
DISCONNECT
ON
DOWN
DWG
DRAWING
ELEC
ELECTRIC OR ELECTRICAL
ELEV
ELEVATION
EMERG.
EMERGENCY
EQUIP.
EQUIPMENT
EXIST.
EXISTING
EXT.
EXTERIOR
FDR
FEEDER
FIXT.
FIXTURE
FLA
FULL LOAD AMPERES
FLR
FLOOR
FLUOR
FLUORESCENT
GALV.
GALVANIZED
GFCI
GROUND FAULT CIRCUIT INTERRUPTER
GFI
GROUND FAULT INTERRUPTER
GND
GROUND
H
HIGH OR HEIGHT
WORIZ.
HORIZONTAL
HP
HORSEPOWER
ATR
HEATER
HVAC
HEATING, VENTILATING AND AiR CONDITIONING
I.G.
ISOLATED GROUND
INCAND.
INCANDESCENT
IND.
INDICATED
NT.
INTERIOR
JB
JUNCTION BOX
KVA
KILOVOLT AMPERES
KW
KILOWATT
KWH
KILOWATT HOUR
L
LENGTH
LCL
LONG CONTINUOUS LOAD
LOC.
LOCATION
LTG
LIGHTING
MAX
MAXIMUM
MFR
MANUFACTURER
MN
MINIMUM OR MINUTES
MTD
MOUNTED
MTG
MOUNTING
MTG. NT.
MOUNTING HEIGHT
NA
NOT APPLICABLE
NF
NON FUSIBLE
N.L.
NiGHT LIGHT
NTS
NOT TO SCALE
P
POLE
PB
PULLBOX
P.C.
PHOTOCELL
PNL
PANEL
PWR.
POWER
RECEPT RECEPTACLE
REQ'D REQUIRED
RM ROOM
SCHED. SCHEDULE
SWT
SHEET
W. FT.
SQUARE FEET
STD.
STANDARD
SURF.
SURFACE
SW.
SWITCH
SWBD
SWITCHBOARD
SYS.
SYSTEM
TEL
TELEPHONE
TEMP.
TEMPORARY OR TEMPERATURE
TRANSF.
TRANSFORMER
TTB
TELEPHONE TERMINAL BACKBOARD
TYP
TYPICAL
Ufa. UNDERGROUND
U.ON. UNLESS OTHERWISE NOTED
V
VOLT
VA
VOLT AMPERES
VD.
VOLTAGE DROP
VERT.
VERTICAL
W
WATTS OR WiRE OR WIDE
W/
WiTH
W/O
WITHOUT
WP.
WEATHERPROOF
NOTE:
NOT ALL ABBREVIATION ARE
USED ON ALL PROJECTS
ELECTRICAL SPECiFICATiONS
A. GENERAL
1. SCOPE
THE DRAWINGS AND THESE SPECIFICATIONS DESCRIBE THE SYSTEMS FURNISH
ALL MATERIALS AND PERFORM ALL WORK REQUIRED BY THE DRAWINGS AND
SPECIFICATIONS. UNLESS SPECIFICALLY NOTED TO THE CONTRARY, FURNISH
AND INSTALL ALL NEW MATERIAL AND EQUIPMENT AS REQUIRED TO PRODUCE
A COMPLETE OPERATNG SYSTEM.
2. PERMITS AND CHARGES
OBTAIN AND PAY FOR ALL NECESSARY CONSTRUCTION PERMITS, INSPECTION
FEES, AND OTHER CHARGES BY AGENCIES HAVING JURiSDiCTiM
3. REGULATIONS AND CODES
PROVIDE AND INSTALL ALL MATERIALS IN CONFORMANCE WITH THE 1999 NATIONAL
ELECTRICAL CODE, CALIFORNIA ADMINISTRATIVE CODE TITLE 8, AND OTHER
CODES AND REGULATIONS HAVING JURISDICTION. INSTALL ALL EQUIPMENT N
ACCORDANCE WiTH THE REQUIREMENTS OF THE NSPECTNG AUTHORITY AND
THE MANUFACTURERS RECOMMENDATIONS
4. VERIFYNG EXISTNG CONDITIONS
BEFORE SUBMITTING BiD, BECOME THOROUGHLY FAMILIAR WITH ACTUAL
EXISTING CONDITIONS AT THE PROJECT SITE. THE INTENT OF THE WORK iS
SHOWN ON THE DRAWINGS AND DESCRIBED HEREINAFTER BY THE ACT OF
SUMTTNG A BiD PROPOSAL FOR WORK, THE CONTRACTOR SHALL BE DEEMED
TO NAVE MADE SUCH A STUDY AND EXAMINATION AND TO ACCEPT ALL
CONDITIONS PRESENT AT THE SITE. NO REQUEST FOR ADDITIONAL PAYMENT
SHALL BE CONSIDERED AS VALID, DUE TO FAILURE TO ALLOW FOR CONDITIONS
WHICH MAY EXiST.
5. COORDINATION
COORDINATE ALL WORK WiTH OTHER TRADES AND WITH THE UTILITY COMPANY.
OBTAIN ALL DRAWINGS THAT WILL REQUIRE COORDINATION AND PROVIDE ALL
ELECTRICAL CONNECTIONS REQUIRED WHETHER SHOWN ON ELECTRICAL DRAWINGS
OR NOT.
LOCATIONS OF ELECTRICAL EQUIPMENT, J -BOXES, AND CONDUIT RUNS SHOWN
ON THE DRAWINGS ARE APPROXIMATE. FiELD VERIFY FOR EXACT LOCATIONS
AND COORDINATE ALL WORK WITH THE OTHER DISCIPLINES TO AVOID CONFLICTS.
THiS CONTRACTOR 15 TO PROVIDE ALL CONTRCIL WIRING, RELAYS, STARTERS,
TiME SWITCHES CONDUITS, ETC. INDICATED THEREON AS BEING PROVIDED
UNDER THE ELECTRICAL WORK
6. AS BUILT
PROVIDE RECORD DRAWINGS TO THE OWNER WITH ALL CHANGES NOTED THEREON
At THE COMPLETION OF THE PROJECT. RECORD DRAWINGS SHALL BE SIGNED
AND DATED BY CONTRACTOR
1. GUARANTEE
CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS
ON ALL WORK AGAINST DEFECTS N WORKMANSHIP AND MATERIALS FOR A
PERIOD OF ONE YEAR, EXCEPT FOR LIGHTWx FIXTURE LAMPS
S SHOP DRAWNGS
SUBMIT REQUIRED SHOP DRAWINGS FOR REVIEW UJITHN ONE WEEK OF BID
AWARD. ALL EQUIPMENT TO BEAR U.L. LABEL OR TWAT OF ANOTHER
ACCEPTABLE TESTING LABORATORY. SHOP DRAWINGS MUST BE STAMPED BY THE
CONTRACTOR FOR CONFORMANCE PRIOR TO SUBMITTING.
ALL EQUIPMENT WAS BEEN PRE -APPROVED BY OILIER AND SPECIFIED AS SUCH.
NO SUBSTITUTIONS WILL BE ALLOWED.
9. CONTRACTOR BID
CONTRACTOR'S BiD SHALL BE BASED ON ALL WORK SWO11N ON THE PLANS AND
AS SPECIFIED. ALL PREMIUM TIME COSTS REQUIRED SMALL BE INCLUDED IN THE BID.
THE CONTRACTOR $WALL BE RESPONSIBLE AT HIS OWN EXPENSE FOR ANY CHANGES
RESULTING FROM ANY PROPOSED SUBSTITUTIONS WHICW AFFECT OTHER PARTS
OF NIS OWN WORK OR THE WORK OF OTHER CONTRACTORS
B: MATERIAL AND INSTALLATION
ALL WORK AND MATERIAL SMALL CONFORM TO THE LATEST RULES OF TME GOVERNING
ELECTRICAL CODE AND INSTALLATION SMALL BE OF THE LATEST NOUSTRY STANDARDS
OF WORKMANSHIP.
ALL MATERIALS SHALL BE NEW AND LiSTED BY UNDERWRITERS LABORATORY (UL,
OR ANOTHER ACCEPTABLE INDEPENDENT TESTING LABORATORY.
L CONDUITS
CONDUITS SHALL BE EMT, RiGiD OR FLEXIBLE STEEL TYPE ABOVE GRADE AND
SCHEDULE 40 PVC BELOW GRADE. FLEXIBLE STEEL CONDUIT SMALL BE MANUFACTURED
N ACCORDANCE WiTH UL -1, USED ONLY FOR LIGHTING FIXTURE CONNECTION, SHORT MOTOR
CONNECTION OR FOR THE EQUIPMENT REQUIRING VIBRATION) ISOLATION. LENGTH 15
LIMITED TO 12" MAXIMUM. A GROUND WiRE 15 REQUIRED IN ALL FLEXIBLE CONDUiT-
CONCEAL ALL CONDUITS, UNLESS OTHERWISE NOTED.
2. WiRE_ AND CABLE IDENTIFICATION
IDENTIFY BRANCH CIRCUITS WITH CORRESPONDING CiRCUIT DESIGNATION AT
THE OVERCURRENT DEVICE, AT ALL SPLICES, AND N JUNCTION BOXES.
MARK CiRCUIT DESIGNATION ON ALL JUNCTION BOX COVERS. CIRCUIT
DESIGNATION MEANS PANEL DESIGNATION AND CiRCUiT NUMBER I.E. A -I
USE PLASTIC COATED SELF -STICKING MARKERS SUCH AS THOMAS a BETTS E -Z
CODE FOR IDENTIFICATION OF CONDUCTORS AND METAL EDGE BANDED PAPER
TAGS ON PULL ROPES.
3. CONDUCTOR$
DELIVER ALL CONDUCTORS TO THE JOB SiTE N ORIGINAL UNBROKEN CARTON
OR REEL, PROPERLY TAGGED WITH U.L. LABEL SiZE, TYPE, MANUFACTURER'S
TRADE NAME AND THE DATE MANUFACTURED (MUST BE MANUFACTURED WITHN 6
MONTHS).
PROVIDE COPPER CONDUCTORS. $12 AWG MINIMUM, UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROVIDE SOLID CONDUCTORS, 610 AWG
AND SMALLER UNLESS OTHERWISE NOTED. PROVIDE STRANDED CONDUCTORS, 09
AWG AND LARGER UNLESS OTHERWISE NOTED.
USE CONDUCTORS WiTH THHN/THWN -2, 90'C. RATED, 600 VOLTS NSULATiON UNLESS
OTHERWISE NOTED.
INSTALLATION OF 600 VOLT CONDUCTORS: CONDUCTORS SMALL BE CONTNUOUS
BETWEEN OUTLETS OR JUNCTION BOXES. MAKE SPLICES N OUTLET BOXES,
PULLBOXE5 OR PANELBOARD GUTTERS. DO NOT SPLICE PANELBOARD FEEDERS.
4. LIGHTING FIXTURES
FURNISH AND INSTALL L16WTNG FIXTURES OF THE TYPE SPECIFIED ON THE
DRAWNGS a PROVIDE APPROPRIATE MOUNTNG HARDWARE. MO SUBSTITUTIONS ALLOWED)
5. SERVICE EQUIP. / PANELBOARDS
PANELBOARDS SHALL BE FACTORY -ASSEMBLED,
SURFACE MOUNTED, AS SHOWN ON DWGS.
PROVIDE TERMINAL LUGS ON MAN BREAKERS RATED FOR USE WITH COPPER CONDUCTORS,
FULL-SIZE NEUTRAL BUS AMC) BOLT -ON CiRCUiT BREAKERS RATED TO EXCEED THE
AVAILABLE SHORT CiRCUIT CURRENT.
PROVIDE PANEL IDENTIFICATION NAMEPLATE AND TYPEWRITTEN LiST OF
CIRCUITS iN THE DIRECTORY FRAME CLEARLY INDICATING THE LOADS
SERVED. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE -0 CO. TYPE NQOD
WITH BOLT -ON BREAKERS. SECURE SURFACE MOUNTED PANELBOARD TO WALL (5).
PROVIDE A PRE -CAST CONCRETE PAD AND VAULT INCLUDING GROUNIDING AS REQUIRED
BY SERVING UTILITY COMPANY. COORDINATE LOCATION AND SERVICE CONDUIT
REQUIREMENTS. PAD / VAULT TO BE BROOKS, OU"ET OR SHAW.
PROVIDE MAIN SWITCHBOARD AS SHOWN ON PLAN, ELEVATION AND ONE LiNE DIAGRAM
COORDINATE UNDERGROUND PULL SECTION!. MAIN DISCONNECT ANY METERING UT14 THE
SERVING UTILITY COMPANY. SWITCHBOARD SMALL BE SQUARE -D, CLASS 2110.
MISCELLANEOUS DISCONNECT SWITCHES, MOTOR STARTERS, ETC. SMALL BE SPECIFICATION
GRADE BY SQUARE -D.
6. NAMEPLATE
PROVIDE NAMEPLATES ON ALL PANELBOARDS, POWER DISTRIBUTION UNITS,
DISCONNECTS, AND ALL ELECTRICAL EQUIPMENT IDENTIFIED BY NAME
AS SHOWN N PLANS. NAMEPLATES SMALL BE LAMINATED BLACK AND
WHITE BAKELITE WITH CHARACTERS CUT THROUGH THE BLACK BAKELITE
(3/16' HiGH LETTERS MINIMUM). ATTACH TO EQUIPMENT WITH SCREWS.
LIGHTING FIXTURE SCHEDULE
LIGHTING FIXTURE SCHEDULE GENERAL NOTES: ALL LIGWT FIXTURES SHALL BE FURNISHED AND INSTALLED COMPLETE WITH ALL NECESSARY HARDWARE FITTINGS AND LAMPS.
X PROVIDE TAMPER PROOF SCREW DRIVER BY MANUFACTURER.
SIE X PROVIDE SEPARATE CIRCUIT WIRING FOR EACH FIXTURE. (480V -T* a 211V-10)
ELECTRICAL 5YM50LS
GENERAL SYMBOLS
NOTES: 1. MOUNTING HEIGHTS NOTED ARE DISTANCES MEASURED FROM THE
DEVICE CENTERLINE TO TWE FINISHED FLOOR OR FINISHED GRADE,
UNLESS OTHERWISE NOTED.
O 2. AN OVAL WITH A NUMBER INSIDE REFERS TO A (REFERENCE NOTE
ON THE DRAWING WHERE iT 15 INDICATED.
SURFACE MOUNTED SWITCHES WiTH MOUNTING HEIGHT 448' (WAN-)
❑'
INPUT
LAMPS
NOTED WITH 'NF'
MANUFACTURER
MOTOR RATED TOGGLE DiSC24NECT SWITCH
TYPE
DESCRIPTION
®
MOUNTING
REMARKS
NO.
WATTS
TYPE
PROTECTION UNLESS OTHERWISE NOTED
POWER AND WIRING DISTRIBUTION
VA
BRANCH CIRCUIT PANELBOARD
4 CATALOG NO.
CONDUIT RUN CONCEALED N CEILING OR WALL (SEE SPECIAL SYSTEMS
O
BASKETBALL COURT
FIXTURE
1050
1
1000
MH
POLE'
HUBBELL
nASB C-1O00MN-Dd-48®-SSP530-1-A-DB
SEE DWG. 5
480V -10
LIGHTING
HASH MARKS NDICATE THE QUANTITY OF CONDUCTORS REQUIRED. UNLESS
OTHERWISE NOTED, NO HASH MARKS NDICATE 2 012 AWG (010 AUKS
CONDUCTORS INDICATED). WHERE A NUMBER iS NOT INDICATED, THE
ES
ONOT
USED
CONDUCTOR SIZE
MIN. RACEWAY SIZE 12 10 8
ONE-HALF INCH 1 to 4• 1 to 4 ------
THREE-QUARTER NCH 5 to 8 5 to 6 Ito 3
LOT LIGHTING
ONE NCM 9 to 13 1 to ll 4 to 5
-QUANTITY OF CONDUCTORS AS INDICATED (TYR)
2LA-1,3,541
INDICATES A HOME" TO PANEL 2LA, CIRCUITS 1-3-5 WITH SHARED
KIM LIGHTING 'CCS' SERIES ARM MOUNTED
SEE DWG. 2
OPARKING
POLES (FIXTURES)
430
1
400
MN
POLE
ON 19'-6' "KRS20-4180 POLE.
480V -10 E5
CONDUIT BEND DOWN AWAY FROM OBSERVER .
PARKING LOT LIGHTING
KIM LIGHTNG 'CCS' SERIES, POLE TOP
SEE 2
CI
POLES (FIXTURES)
430
1
400
POLE
MOUNTING. POLE TO BE 19'-6' %"20-4180.
480V -10 ES
POST TOP LIGHTING:SPAULDiNG
LIGHTING NC_
"VA-150-HPS,
SEE
SEE i
O
FIXTURE VANDAL
113
1
150
NPS
POLE TOP
WITH 12 RAPVA POLE, 41.2 DIA.
150
x 12'-0" WIGH, AD NTAMPER RESISTANT METAL
FIN TYPE
BASE COVER PLATE
480V -14, E5
DI
SAME AS "D" WITH
T
150
POLE
0-H, a
SPAULDING LIGHTING INC. 'VA -15 P5
KIM LiGHTINdCs 'Yo150R-10@-HPS-HL"14-21'1 WiTH 12
SEE i
ADDITIONAL FLOOD LIGHT
300
HPS
1 .DIA x ., iGH
PVA POLE, /2FIXTURE
)K )K
1
100
TAMPER RESISTANTETAL ASE COVE PLATE
E5
211 a 480V -10
O
GRADE MOUNTED
FLUORESCENT FIXTURE FOR
35
1
32
Ts
FLUOR
GRADES
LiTELiNE SERIES
SEE 4
Eg
MONUMENT SiGN
'CFS' - 35 -28 -FL -120 -A15 -N-56
120V
O4'
FLUORESCENT (2) LAMP
STRiPLIGHT WiTH WiREGUARD
30
1
32
F32T8
SP35
SURFACE
COLUMBIA 0CS4-232-EBWLH
120V
MOISTURE AND
14M
SURFACE
VANDAL RESISTANT
)K
OENCLOSED,
DUST RESISTANT FIXTURE W/
60
1
50
CLEAR
CEILING /
WOLCOR "HSC88-505-120v. APF -TX
PRISMATIC LENS
WALL
120V
J
O
5' x 48' FLUORESCENT FIXTURE
WITH J81 POLY -CARBONATE
F32T8
SURFACE
KENALL VANDAL RESISTANT
120V
DIFFUSER
30
1
32
SP35
"SH5-48-i-32-i-120V. J$1-9500
Jl
5' x 48' FLUORESCENT FIXTURE
WITH POLY -CARBONATE
F32T8
SURFACE
KENALL VANDAL RESISTANT
PROVIDE EMER3. BATTERY
PACK WHERE INDICATED
.181
60
2
32
DIFFUSER
SP35
98145-48-2-32-1-120V .181-9500.
ON PLAN.
12OV.
LIGHTING FIXTURE SCHEDULE GENERAL NOTES: ALL LIGWT FIXTURES SHALL BE FURNISHED AND INSTALLED COMPLETE WITH ALL NECESSARY HARDWARE FITTINGS AND LAMPS.
X PROVIDE TAMPER PROOF SCREW DRIVER BY MANUFACTURER.
SIE X PROVIDE SEPARATE CIRCUIT WIRING FOR EACH FIXTURE. (480V -T* a 211V-10)
ELECTRICAL 5YM50LS
GENERAL SYMBOLS
NOTES: 1. MOUNTING HEIGHTS NOTED ARE DISTANCES MEASURED FROM THE
DEVICE CENTERLINE TO TWE FINISHED FLOOR OR FINISHED GRADE,
UNLESS OTHERWISE NOTED.
O 2. AN OVAL WITH A NUMBER INSIDE REFERS TO A (REFERENCE NOTE
ON THE DRAWING WHERE iT 15 INDICATED.
SURFACE MOUNTED SWITCHES WiTH MOUNTING HEIGHT 448' (WAN-)
❑'
DISCONNECT SWITCH WITH OVERCURRENT PROTECTION UNLESS OTHERWISE
ROSENA PARK - EAST
10-A RK CTR. LOT W
NOTED WITH 'NF'
S T
MOTOR RATED TOGGLE DiSC24NECT SWITCH
S M
MANUAL MOTOR STARTER
®
MAGNETIC MOTOR STARTER
COMBINATION MOTOR STARTER -DISCONNECT DEVICE, WITH OVERCURRENT
PROTECTION UNLESS OTHERWISE NOTED
POWER AND WIRING DISTRIBUTION
BRANCH CIRCUIT PANELBOARD
CONDUIT RUN CONCEALED N CEILING OR WALL (SEE SPECIAL SYSTEMS
r
AND DEFINITION SYMBOLS FOR RACEWAY CODING)
-- --
CONDUIT RUN EXPOSED
— —NI
CONDUIT RUN N OR BELOW FLOOR SLAB OR GRADE
010
INDICATES AN EQUIPMENT GROUND CONDUCTOR
,T_
HASH MARKS NDICATE THE QUANTITY OF CONDUCTORS REQUIRED. UNLESS
OTHERWISE NOTED, NO HASH MARKS NDICATE 2 012 AWG (010 AUKS
CONDUCTORS INDICATED). WHERE A NUMBER iS NOT INDICATED, THE
CONDUCTORS ARE 012 AUG (MN).
CONDUIT SiZE SMALL BE AS FOLLOWS:
CONDUCTOR SIZE
MIN. RACEWAY SIZE 12 10 8
ONE-HALF INCH 1 to 4• 1 to 4 ------
THREE-QUARTER NCH 5 to 8 5 to 6 Ito 3
ONE NCM 9 to 13 1 to ll 4 to 5
-QUANTITY OF CONDUCTORS AS INDICATED (TYR)
2LA-1,3,541
INDICATES A HOME" TO PANEL 2LA, CIRCUITS 1-3-5 WITH SHARED
NEUTRAL AND CiRCUiT 1 WITH DEDICATED NEUTRAL
FLEXIBLE CONDUIT
n n
CABLE OR CORD
�YJC�
ARROW INDICATES A PLUG -N CONNECTION
----0
CONDUIT BEND UP TOWARD OBSERVER
—®
CONDUIT BEND DOWN AWAY FROM OBSERVER .
SPECIAL SYSTEMS RACEWAY CODING
T TELEPHONE
GENERAL LIGHTING
INDICATES A REFERENCE TO THE LIGHTING FIXTURE SCHEDULE:
TYPE 'A' FiXTURE INDICATED.
® SURFACE MOUNTED FLUORESCENT FiXTURE.
D FIXTURES WiTH EMERGENCY BATTERY PACK.
F-0 --j SURFACE MOUNTED FLUORESCENT STRIP FIXTURE
a WALL MOUNTED LIGHT FIXTURE.
D PARK WALKWAY LIGHTING FIXTURE, POLE MOUNTED (SHADED
INDICATES SECURITY FIXTURE).
M.0 ❑0 PARKING LOT LIGHTING FIXTURE, POLE MOUNTED (SHADED
INDICATES SECURITY FiXTURE).
❑ SURFACE CEILING MOUNTED LiGHT r-wuRE.
t
y GRADE MOUNTED FLOOD LIGHT FIXTURE.
Q -O BASKETBALL COURT LIGHTING FIXTURE, POLE MOUNTED.
RECESSED SWITCHES WITH MOUNTING HEIGHTS 448' (U.ON.J
$a SINGLE POLE $WITCH, 20A,120 VAC
CEILING MOUNTED OCCUPANCY SENSOR FOR CONTROL OF LIGHTS.
® NOViTAS 'DESIGNER SERIES OR EQUAL BY WATT STOPPER PROVIDE
POWER PACK AT LIGHT FIXTURE OUTLET BOX.
SUBSCRIPT LETTERS NEXT TO THE ABOVE SYMBOLS INDICATES DEVICE
CONTROLLED BY THE SWITCH WITH THE SAME SUBSCRIPT LETTER WHERE
MULTIPLE SUBSCRIPT LETTERS APPEAR EACH SUBSCRIPT DESIGNATES
ONE SWiTCW OF THE TYPE INDICATED.
SINGLE LINE SYMBOLS
® UTILITY COMPANY METERNG AND TEST BLOCKS AS REQUIRED BY THE
SERVING AGENCY
DISTRIBUTION TRANSFORMER OR INSTRUMENTATION POTENTIAL
rYTY TRANSFORMER
n CiRCUIT BREAKER
CIRCUIT BREAKER WITH GROUND FAULT PROTECTION
GROUND SEE SINGLE LINE DIAGRAM, BONDS TO GROUND ELECTRODE
SHALL BE BY EXOTHERMIC WELDS.
MOTOR
(NUMBER INSIDE SYMBOL DESIGNATES W OF MOTOR)
OUTLETS
MOUNTING HEIGHTS AS INDICATED ON SYMBOLS LIST, UNLESS OTHERWISE NOTED
BY SPECIFIC LOCATION N PLANS
TYPICAL OUTLET CODING
Q CIRCLE OR DIAMOND DESIGNATES OUTLET BOX, CEILING MOUNTED
4 BRACKET DESIGNATES OUTLET BOX, WALL MOUNTED AT 418' UNLESS
OTHERWISE NOTED
(Q4 DOUBLE DUPLEX (QUAD) RECEPTACLE 418" AFF. NEMA 5-20R (LION.
i DOUBLE DUPLEX (QUAD) RECEPTACLE: NEMA 5-20R (UAN-)
MOUNT +6" ABOVE COUNTER SPLASH
®I TELEPHONE OUTLET
NOTE:
NOT ALL SYMBOLS ARE USED ON ALL PROJECTS.
CITY OF FONTANA, CALIFORNIA
DRAWN BY
EF:
ROSENA PARK - EAST
10-A RK CTR. LOT W
SCALE
NONE
DESIGNED BY.
RF.
DATE:-
ATE:RF: 09/02/03
CHECKED BY:
Ll
B CA— ).
1
CITY ENCaR�tE R.C.E 51152 D� DATE 1213VO3
DWG. NOz
34Q4
1
V1
GENERAL NOTES
i. ALL DEVICES INSTALLED OUTSIDE OR IN DAMP LOCATIONS SHALL BE
APPROVED WEATHERPROOF.
2. THE CONTRACTOR SHALL PROVIDE SUPPORT FOR ALL FIXTURES AND
ELECTRICAL EQUIPMENT TO COMPLY WITH THE SEISMIC REQUIREMENTS OF
THE UNIFORM BUILDING CODE AND ALL LOCAL ORDINANCES.
3. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, THE ELECTRICAL DRAWINGS
ARE E55ENTIALLY DIAGRAMMATIC. THE SiZE AND LOCATION OF EQUIPMENT
iS SHOWN TO SCALE WHEREVER POSSIBLE. THE CONTRACTOR SHALL VERIFY
ALL CONDITIONS DATA INFORMATION AS INDICATED ON THE DRAWINGS AND
N THE SPECIFICATIONS SECTIONS WHERE ELECTRICAL WORK INTERFACES
WITH OTHER TRADES.
4. ALL UNDERGROUND BONDING CONDUCTORS SHALL BE COPPER.
5. ALL SYMBOLS AND ABBREVIATION$ SHOWN MAY NOT BE APPLICABLE TO THIS
PROJECT.
INSTALL EQUIPMENT GREEN GROUNDING CONDUCTOR,
SiZED PER N.E.C. 250-122 N ALL CONDUITS.
GROUND WIRES ARE NOT SHOWN ON DRAWINGS.
MEOHANlCAt-
�L�CTF!"OAL
CANS ULT"N G31
Sinha & Keyfauver Engineering, Inc.
421 EAST HUNTINGTON DRIVE
MONROVIA, CALIFORNIA 91016
626-930-1383 Fax: 626-930-1385
Job No: 99100
10979
�( E p. 6/30/2007
CAL��
DATE SIGNED: 11-6-2003
SIL IZp04,-
LANDSCAPE
ARCHITECTURE
SITE PLANNING
wawftftlm
ftft
4 O CA 9it30
Floc 04%M ��''aa''y�yy�
Cliff, awsWSN�w
MWeto
LA SEAL
N'
PROJECT / CLIENT
L
Q
N
0
L0 O
O
• 'd
� O
`'
m
Noe
L t0
CU E
Y
C
C.� v
C U
I tti
C
w
C
O
UL
O
U
SHEET TITLE _1
i
r
Al�
DRAWN BY
R.R.
DATE
09/02/03
SCALE
AS NOTED
I JOB NUMBER
0143-4
SHEET NUMBER
E-1
OF 8 SHTS. 26