Loading...
HomeMy WebLinkAbout3404-21U C C •ti L OJ CU C .ry C w C ro L L t -i L U CIO3 J / Y L 00L CUC C: a� J T L L U L Q Cn 1 STATION BASE, MID ALUMINUM 1 2 ENCLOSURE, MID ALUMINUM 1 3 FAN, EXHAUST 1 4 DISCONNECT, FUSIBLE 1 5 SURGE ARRESTOR 1 6 RACK, PANEL 1 7 PANEL. OASIS CONTROL 1 T. FAN 4" FLANGED 3/4" FILL PUMP 151 MOTOR 1 16 VALVE, 4" CHECK i 17 MANIFOLD, 4" DISCHARGE 1 18 SWITCH. FLOW 1 1201 VALVE, 4" ISO I 1 I 1211 DISCHARGE. 4" FLANGED i 1 231 PUMP, PRESSURE MAINTENANCE 1 DESCRIPTION BASIC MODEL NUMBER: REFERENCE SFBV-M4XXA-XXX I XO REMOTE CONTROL VALVE ("X" IN MODEL NUMBER REPRESENTS DETAIL SPECIFIC TO ORDER) SIZE INDICATED 10-40 HP AVAILABLE IN 208/230/3/60 10-50 HP AVAILABLE IN 460/3/60 10-50 HP AVAILABLE IN 575/3/60 10 HP AVAILABLE IN 230/1/60 (CONTACT FACTORY FOR 110V APPLICATIONS) WEIGHT: 7 1900 LBS. MAXIMUM PART NOTES: 1.) MINIMUM CLEARANCE FROM ANY OBSTRUCTION AS REQUIRED BY NATIONAL ELECTRIC CODE 3'-6- NOTE 1 APPROVAL FOR CONSTRUCTION BY DATE i - MODIFICATION OF THIS DOCUMENT IN ANY FORM OUTSIDE OF FLOWTRONEX ENGINEERING DEPARTMENT RELEASES FLOWTRONEX OF ANY AND ALL LIABILITY AND RESPONSIBILITY ASSOCIATED WITH THE MODIFICATION. THE LATEST REVISION OF THIS DRAWING IN THE FLOWTRONEX ARCHIVES IS THE CONTROLLING DOCUMENT REGARDLESS OF WHAT MODIFICATIONS HAVE BEEN MADE OUTSIDE OF THE FLOWTRONEX ENGINEERING DEPARTMENT. NO SUCH CHANGES WILL BE HONORED BY FLOWTRONEX. a ,c A, 9" a- Rcecy10661 NEWKIRK ROAD MID SERIES, VARIABLE SPEED STATION: DALLAS, TX 75220 WITH PM PUMP FLOW RATE: 300 GPM AXnUSA 1-800-527-0539 INLET• PSI: 50 PSI �in9 Si DATE03/06/02 DWG NGSFBV-M4xxA-xxxlx0 DISCH. PSI: 105 PSI DESIGNED AND MANUFACTURED BY DRAWN BY K. GARNER SCALE NONE HORSEPOWER(S): PM PUMP: PUMP 2: PUMP 1: FLOWTRONEX PSI, INC. POWER REQ'D: APPROVED BY PAGE 1 OF 1 REVISION A PUMP START: REV DESCRIPTION BY DATE NOTE: CONTRACTOR TO PROVIDE FOR A CONCRETE PAD ON WHICH THE PUMP ASSEMBLY WILL BE INSTALLED BY CONTRACTOR. CONCRETE PAD TO BE 6" THICK WITH #4 REBARS 6" O.C. GOING ON BOTH DIRECTIONS WITH A 6" MINIMUM CLEARANCE ON ALL SIDES OF THE PUMP ASSEMBLY. SPECIAL NOTE: SOLVENT WELD PIPE FOR MAIN LINES 3" AND LARGER HAS BEEN SPECIFIED AT THE SOLE REQUEST OF THE CITY OF FONTANA'S COMMUNITY DEVELOPMENT DEPT., TIM RASTEDT, ASSISTANT PARK PLANNER. SCALITER IRRIGATION ENGINEERING, INC. DOES NOT RECOMMEND NOR APPROVE THE USE OF THIS TYPE OF PIPING CONNECTION FOR MAIN LINES 3" AND LARGER. AS SUCH, SCALITER IRRIGATION ENGINEERING, INC. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY PROBLEMS WITH THE IRRIGATION SYSTEM OR THE ENVIRONMENT DUE TO THE USE AND POSSIBLE FAILURE OF THESE CONNECTIONS. THE IRRIGATION PLANS CONTAIN INFORMATION PROPRIETARY TO SCALITER IRRIGATION ENGINEERING, INC. AND ARE FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SCALITER IRRIGATION ENGINEERING, INC. ALL RIGHTS RESERVED, OC COPYRIGHT 1987-2002. GENERAL IRRIGATION NOTES: 1. THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE MAXIMUM FLOW DEMAND SHOWN ON THE DRAWINGS AT EACH POINT OF CONNECTION. THE CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION, REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S AUTHORIZED REPRESENTATIVE. 2. THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHERE POSSIBLE. BELOW PAVED AREAS A MINIMUM OF 6" LAYER OF CLEAN FILL SAND SHALL BE INSTALLED ABOVE AND BELOW PIPING. 3. BEFORE ANY WORK COMMENCES, A CONFERENCE SHALL BE HELD WITH THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR, REGARDING GENERAL REQUIREMENTS OF THIS WORK. 4. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT UTILITIES AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND HE IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO, THESE LINES OR STRUCTURES. 5. CONTRACTOR AGREES THAT HE SHALL ASSUME COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT INCLUDING THE SAFTEY OF ALL PERSONS AND PROPERTY, THIS REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND CONTRACTOR AGREES TO DEFEND AND INDEMNIFY AND HOLD OWNER AND DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. 6. DO NOT INSTALL THE IRRIGATION SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS, IN THE FIELD, THAT OBSTRUCTIONS, GRADE DIFFERENCES, OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CON- SIDERED IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS NOT PERFORMED, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO PREVENT OVERSPRAY ONTO WALKS, ROADWAYS, AND/OR BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM OPERATING FLOW FOR EACH SYSTEM. 8. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN SHRUB OR GROUND COVER AREAS SHALL BE INSTALLED SO THAT THE TOP OF THE SPRINKLER HEAD IS 1-1/2" (INCH) ABOVE FINISHED GRADE. 9. ALL POP-UP TYPE SPRINKLER HEADS INSTALLED IN LAWN AREAS SHALL BE INSTALLED SO THE TOP OF THE SPRINKLER HEAD IS FLUSH WITH ADJACENT SIDE- WALK OR CURB. 10. IN OPEN SEEDED LAWN AREAS SET TOP OF POP-UP TYPE SPRINLER HEADS 3" ABOVE FINISH GRADE UNTIL LAWN IS ESTABLISHED. LOWERING OF ALL LAWN HEADS BY THE CONTRACTOR SO THAT THE TOP OF THE SPRINKLER HEADS IS FLUSH WITH FINISHED GRADE, SHALL BE ACCOMPLISHED WITHIN TEN (10) DAYS AFTER NOTIFICATION BY THE OWNER'S AUTHORIZED REPRESENTATIVE. 11. ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE OF THE AREA TO BE IRRIGATED UNLESS OTHERWISE DESIGNATED ON THE PLANS. 12. 110/120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL OUTLET TO THE AUTOMATIC CONTROLLER. 13. INSTALL ALL PIPE MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE TEFLON TAPE OR ON ALL PVC MALE PIPE THREADS ON ALL SPRINKLER SWING JOINT AND VALVE ASSEMBLIES. 14. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS WORK WITH THE SUBCONTRACTORS FOR THE LOCATION AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING STRUCTURES, ETC. 15. IN ADDITION TO THE CONTROL WIRE SLEEVES AND PIPE SLEEVES SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE AND PIPE SLEEVES OF SUFFICIENT SIZE UNDER ALL PAVED AREAS. NOTES (TYPICAL): 1) WHEN VERTICAL OBSTRUCTIONS (FIRE HYDRANTS, STREET LIGHTS, TREES, ETC.) INTERFERE WITH THE SPRAY PATTERN OF THE SPRINKLER HEADS SO AS TO PREVENT PROPER COVERAGE, THE CONTRACTOR SHALL FIELD ADJUST THE SPRINKLER SYSTEM BY INSTALLING A QUARTER CIRCLE OR HALF CIRCLE SPRINKLER HEAD ON EACH SIDE OF THE OBSTRUCTION SO AS TO PROVIDE PROPER COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 2) MAINLINE, VALVES, IRRIGATION METERS, ETC., ARE SHOWN ON THE STREET AND/OR SIDEWALK FOR CLARIFICATION ONLY. INSTALL IN PLANTER AREA THROUGHOUT THE SITE. 3 ADJUST ALL SPRINKLERS FOR HEAD-TO-HEAD COVERAGE. 4 INSTALL BACKFLOW PREVENTER IN GROUND COVER OR SHRUB AREA, ONLY. 5 AFTER ESTABLISHMENT OF ALL PLANT MATERIAL, CONTROLLERS SHALL BE PRO- GRAMMED TO IRRIGATE SOLELY DURING NIGHTTIME. 6) CONTROLLER SEQUENCE FOLLOWED BY AN 'a', 'b' OR 'c' LETTER INDICATES THAT THE VALVES ARE TO BE CONNECTED TO THE SAME STATION NUMBER AS NOTED ON DRAWINGS TO START IRRIGATING SIMULTANEOUSLY, e.g., VALVE A4b AND VALVE A4c ARE TO BE CONNECTED TO THE SAME STATION NUMBER 4 AT CONTROLLER 'A'. FLOW SENSOR NOTES: PROFESSIONAL MEMBER AMERICAN SOCIETY OF IRRIGATION CONSULTANTS 4& Donlei SooiTter FOUNDED 1970 Number. PR1054 Dote: J 1.FLOW SENSOR SHOULD BE INSTALLED IN-LINE, ONE AT EACH POC, WITH 10 DIAMETER OF SENSOR -SIZED PIPE UPSTREAM OF FLOW SENSOR AND 5 DIAMETER OF SENSOR -SIZED PIPE DOWNSTREAM, e.g., 6" SENSOR NEEDS 60" OF 6" PIPE UPSTREAM AND 30" OF 6" PIPE DOWNSTREAM. 2.17LOW SENSOR SHOULD BE INSTALLED 10 PIPE DIAMETER UPSTREAM OR DOWNSTREAM OF ANY VALVE, FITTING, METER OR BACKFLOW DEVICE. 3.WIRES FROM FLOW SENSOR TO CONTROLLER SHOULD CONSIST OF ONE (1) BLACK AND ONE (1) RED STANDARD #14 IRRIGATION VALVE WIRES. 4.FLOW SENSOR SHALL BE HOUSED IN A VALVE BOX AND MARKED "FS" PVC PIPE NOTES: 2-1/2" AND LARGER USE SOLVENT WELD PIPE WITH SCH. 80 FITTINGS AND THRUST BLOCKS AS PER CITY OF FONTANA DETAIL x#520 2" AND SMALLER USE SOLVENT WELD PIPE WITH PVC SCHEDULE 80 FITTINGS. TYPICAL. UNAUTHORIZED CHANGES AND USES CAUTION: SCALITER IRRIGATION ENGINEERING, INC. WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USE OF THE IRRIGATION PLANS. ALL CHANGES TO THE IRRI- GATION PLANS MUST BE IN WRITING AND MUST BE APPROVED BY SCALITER IRRIGATION ENGINEERING, INC. LEGEND GENERAL LEGEND SCALITER IRRIGATION ENGINEERING INC ® RRIOAT10N MASTER PI.AMNG&MRMTION DESK9WWATER MANAGEMENT 902 AARON DRIVE REDLANDS, CALIFORNIA 92374 (909) 794-5811 FAX (909) 794-5873 SYM. DESCRIPTION MANUF. & PART NO. REFERENCE ® REMOTE CONTROL VALVE IRRITROL SYST. 100 SERIES CENTURY PLUS' PSI ARC SIZE INDICATED WITH OMNIREG 5-100 PSI REG. OMR-100 DETAIL N0. 6 H4" MASTER IRRIGATION VALVE GRISWOLD 2250-4" (EPDXY-FUSED COATING)DETAIL N0. 2 3 15 30 360 7 © PART BOOSTER PUMP ASSEMBLY FLOWTRONEX PSI INC (800) 786-7480 DETAIL TORO 570Z-6P-COM-15TQ-PC 2.3 15 30 MODEL: FLOBOY SFBV-M4L5A-22P1 NO/4C THIS SHEET ® HALF CIRCLE 6" BACKFLOW PREVENTER FESCO 825YD-6" SERIES WITH A FESCO TORO 570Z -6P -COM -15H -PC 1.5 R 30 180 758 'Y" STRAINER 100 MESH DETAIL NO. 1 FS FLOW SENSOR DATA INDUSTRIAL IR-22OSS DETAIL NO. 3 TORO 570Z -6P -COM -15Q -PC 0.75 15 30 90 GATE VALVE, PIPE SIZE 2-1/2 AND SMALLER, NISCO T-113 FULL w SPRAY 3" AND LARGER, NIBCO P -619 -RW DETAIL N0. 4 1.92 IRRIGATION SATELLITE TURF STAR, INC (800) 585-8001 X4012 360 7 A TSIN-SSTFONT-24W WITH RADIO LINK CIRCLE O HEAD TSIN-RLFONT AND THE FOLLOWING ITEMS: DETAIL NO. 9 12 30 SENSOR INPUT BOARD MODEL 995-63 7 a 1/4 RELAY 2W925 AND RELAY BASE 2A582. SPRAY HEAD TORO 570Z -6P -COM -12Q -PC TIPPING RAIN BUCKET TE525-L25 12 30 90 7 IRRIGATION WATER METER SIZE INDICATED N/A CIRCLE SPRAY M TORO 5702 -6P -COM -10F -PC 1.33 10 N A / 36Q 7 V UNDER CIVIL WORK CIRCLE SPRAY HEAD QUICK COUPLING VALVE RAIN BIRD 33DLRC DETAIL NO. 5 30 180 7 v 1/4 CIRCLE 3" AD LARGER USE PVC CLASS 200, SDR -21 HEAD TORO 570Z -6P -COM -10Q -PC PRESSURE SUPPLY LINE, SIZE INDICATED 2 AND 2-1/2 USE PVC CLASS 315 SPECIFICATION 90 7 1-1/2" AND SMALLER USE PVC SC. 40 FULL CIRCLE NON PRESSURE LINE ,SIZE INDICATED PVC CLASS 200 SPECIFICATION 0.88 DENOTE MAIN LINE SLEEVE, 2 X LINE SIZE PVC SC. 80 SPECIFICATION 7 DENOTE LATERAL LINE SLEEVE, 2 X LINE SIZE PVC SC 80 SPECIFICATION SPRAY DENOTE SLEEVE FOR WIRES, 2 X LINE SIZE PVC SC 40 SPECIFICATION 8 30 180 7 1/4 CIRCLE SPRAY CONTROLLER SEQUENCE --__GALLONS PER MINUTES REMOTE CONTROL VALVESIZE SPRINKLER HEADS SYM. DESCRIPTION DRAWN BY: ROSENA PARK EAST MANUF. & PART NO. GPM RAD PSI ARC DETAIL NO. ® FULL CIRCLE SPRAY HEAD TORO 570Z -6P -COM -15F -PC 3 15 30 360 7 O PART CIRCLE SPRAY HEAD TORO 570Z-6P-COM-15TQ-PC 2.3 15 30 270 7 ® HALF CIRCLE SPRAY HEAD TORO 570Z -6P -COM -15H -PC 1.5 15 30 180 7 e 1/4 CIRCLE SPRAY HEAD TORO 570Z -6P -COM -15Q -PC 0.75 15 30 90 1 7 FULL CIRCLE SPRAY HEAD TORO 570Z -6P -COM -12F -PC 1.92 12 30 360 7 A HALF CIRCLE SPRAY HEAD TORO 570Z -6P -COM -12H -PC 0.96 12 30 180 7 a 1/4 CIRCLE SPRAY HEAD TORO 570Z -6P -COM -12Q -PC 0.48 12 30 90 7 �( FULL CIRCLE SPRAY HEAD TORO 5702 -6P -COM -10F -PC 1.33 10 30 36Q 7 V HALF CIRCLE SPRAY HEAD TORO 570Z -6P -COM -10H -PC 0.66 10 30 180 7 v 1/4 CIRCLE SPRAY HEAD TORO 570Z -6P -COM -10Q -PC 0.33 10 30 90 7 0 FULL CIRCLE SPRAY HEAD TORO 570Z -6P -COM -8F -PC 0.88 8 30 360 7 HALF CIRCLE SPRAY HEAD TORO 5702 -6P -COM -8H -PC 0.44 8 30 180 7 1/4 CIRCLE SPRAY HEAD TORO 570Z -6P -COM -8Q -PC 0.22 8 30 90 7 HALF CIRCLE SPRAY HEAD TORO 570Z -6P -COM -5H -PC 0.20 5 30 180 7 1/4 CIRCLE SPRAY HEAD TORO 570Z -6P -COM -5Q -PC 0.10 5 30 90 7 ® SIDE STRIP SPRAY HEAD TORO 570Z-6P-COM-4SST-PC 0.88 N/A 1 30 4X30 7 o END STRIP SPRAY HEAD TORO 570Z-6P-COM-ESST-PC 0.44 N/A 1 30 415 7 FULL CIRCLE ROTOR HEAD TORO 644-02-43 15.7 55 60 360 7 4s HALF CIRCLE ROTOR HEAD TORO 642-02-43 15.7 55 60 180 7 ® 174 -CIRCLE ROTOR HEAD TORO 641-02-41 11.0 50 60 90 7 148 @ PART CIRCLE ROTOR HEAD TORO 640-02-43-148 15.7 55 60 148 7 @127 PART CIRCLE ROTOR HEAD TORO 640-02-41-127 11.0 50 60 127 7 173 43 PART CIRCLE ROTOR HEAD TORO 640-02-43-173 15.7 55 60 173 7 @192 PART CIRCLE ROTOR HEAD TORO 640-02-43-192 15.7 55 60 192 7 238 @ PART CIRCLE ROTOR HEAD TORO 640-02-41-238 11.0 50 60 238 7 @ HALF CIRCLE ROTOR HEAD HUNTER 1 -20 -HP -ADS -3.5 3.00 35 1 40 180 1 5 35 174 CIRCLE ROTOR HEAD HUNTER 1 -20 -HP -ADS -2.0 1.80 .35 40 90 8 @O HALF CIRCLE ROTOR HEAD HUNTER 1 -20 -HP -ADS -3.0 2.40 30 40 180 8 0 1/4 CIRCLE ROTOR HEAD HUNTER 1 -20 -HP -ADS -1.5 1.40 30 40 90 8 © HALF CIRCLE ROTOR HEAD HUNTER 1 -20 -HP -ADS -2.0 1.80 25 4.0 180 8 Q 1/4 CIRCLE ROTOR HEAD HUNTER 1 -20 -HP -ADS -1.0 1.00 25 40 90 8 ® FULL CIRCLE ROTOR HEAD HUNTER 1-20-HP-36S-3.OSR 2.70 20 40 360 8 ® HALF CIRCLE ROTOR HEAD HUNTER 1-20-HP-ADS-1.5SR 1.30 20 40 180 8 1 4 CIRCLE ROTOR HEAD HUNTER 1-20-HP-ADS-0.75SR 0.70 20 40 90 8 @ HALF CIRCLE ROTOR HEAD HUNTER 1-20-HP-ADS-I.OSR 0.90 15 40 180 8 1 4 CIRCLE ROTOR HEAD HUNTER 1-20-HP-ADS-0.5SR 0.43 15 40 90 8 P@ FULL CIRCLE ROTOR HEAD HUNTER 1-20-6P-36S-3.OSR 2.70 20 40 360 7 @P HALF CIRCLE ROTOR HEAD HUNTER 1-20-6P-ADS-1.5SR 1.30 20 40 180 7 P@ HALF CIRCLE ROTOR HEAD HUNTER 1 -20 -6P -ADS -3.5 1 3.00 35 40 180 7 35 1/4 CIRCLE ROTOR HEAD HUNTER 1 -20 -6P -ADS -2.0 1 1.80 1-35--t-40 90 7 NOTE: USE TORO 570Z -12P -COM, 12" POP-UP SPRAY HEADS IN LIEU OF TORO 570Z -6P -COM, 6" POP-UP SPRAY HEADS IN ALL GROUNDCOVER AND SHRUB PLANTING AREAS. SEE CONSTRUCTION DETAIL NO. 8. ADJUST FOR HEAD-TO-HEAD COVERAGE. TYPICAL. Underground Service Alert Call: TOLL FREE 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG CITY OF FONTANA, CALIFORNIA DRAWN BY: ROSENA PARK EAST SCU: GPD 10 -ACRE PARK TR. 15842 LOT''A") NO SCALE DESIGNED BY: DATE: GPD 06/02/03 CHECKED BY: O D Y:. DA�'E;�•/ . APPRDATE DWG. NO.: 1 JAF ,CQ ENGINEER RC.. ,7 iZ0J/I)J 3404 DESIGN GROUP LAND S CAPE ARCHITECTURE SITE PLANNING 1062 Ch d Street, Sui 110p6 R($�p4 $>�ga, CA 130 Fax (909 4-2802 �` CaR7 itC. ede 95 L.A. SEAL�1 PROJECT CLIENT SHEET TITLE REVISIONS A A A A DR S ON DRAWN BY � S.I.E DATE 06-02-03 SCALE NO SCALE JOB NUMBER-� 0143-4 SHEET NUMBER L. U 21 OF 26 SHTS. 1 1 REVISIONS A A A A DR S ON DRAWN BY � S.I.E DATE 06-02-03 SCALE NO SCALE JOB NUMBER-� 0143-4 SHEET NUMBER L. U 21 OF 26 SHTS. 1