HomeMy WebLinkAbout3375-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND
THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ('GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS
SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE
PRECEDENCE PROVISIONS IN THE "GREEN BOOK', THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER
FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING
DIVISION PRIOR TO THE START OF ANY WORK, INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO
THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS, CALL (909) 350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF
CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER,
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES
AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN
DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY,
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF
THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF
CALIFORNIA, TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT
PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE
PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION,
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE,
ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD
CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES,
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION.
CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERUNE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK
TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION
CONTROL STAKING DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION
TO THE CITY ENGINEER.
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS,
SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS
A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE
MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT
ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE
PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE
RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION
OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23, ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
24. 'IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE
BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL
CLEANOUT.
25, SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA
STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700.
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS
IN ALIGNMENT.
28, PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS.
CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE
PLANS.
29. ALL 4' HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30, TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12' BELOW THE GROUND SURFACE. WHEN PUBLIC
UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED
FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL.
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE
ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35, APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR
UPON COMPLETION OF PAVING,
37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL
DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS
TO THE CITY ENGINEER.
rR�\rr x\10, 1 �'
-LEGEND
BC
SEWER LINE
EC
SEWER LINE PER
CL
OTHER SHEET
- -EX S--- -
EXIST. SEWER LINE
F.S.
STORM DRAIN LINE
F.
FINISHED DIRT
WATER LINE
- ---E-X W_
EXIST. WATER LINE
SEWERLINE
SEWER MANHOLE
STORM DRAIN LINE
DIRECTION OF FLOW
WATERLINE
- -
RIGHT OF WAY
10+00.00
EDGE OF PAVEMENT
-
CENTERLINE
-ter-
WATER VALVE
♦-
FIRE HYDRANT
(909) 820-5598 -- UNDERGROUND
STREET LIGHT
®
HANDICAPPED ACCESS RAMP
BC
BEGIN CURVE
EC
END CURVE
CL
CENTERLINE
F.L.
FLOWLINE GUTTER
F.S.
FINISHED SURFACE
F.
FINISHED DIRT
EX
EXISTING
S
SEWERLINE
SD
STORM DRAIN LINE
W
WATERLINE
ST
STREET STATION
10+00.00
SEWER STATION
MH
MANHOLE
INT.
INTERSECTION
R/W RIGHT OF WAY
CONSTRUCTION NOTES
�1 CONSTRUCT SEWER MANHOLE PER CITY OF FONTANA STD. NO. 109, 112, & 114
�2 CONSTRUCT 4" DIA, (EXTRA STRENGTH) V.C.P. LATERAL WITH CLEAN-OUT AND
PLUG PER CITY OF FONTANA STD. NO. 125
O INSTALL 8' PLUG
® CONSTRUCT 8" D,I.P. SEWER MAIN
Q 4A CONSTRUCT 8" V,C.P. SEWER MAIN
05 INSTALL SEWER BACKFLOW DEVICE
® REMODEL EXIST. SEWER MANHOLE TO FLOW SOUTHERLY PER DETAIL 'A" ON SHT. 3.
Q REMOVE EX, 10" D.I.P, SEWER (CONCRETE ENCASED) AND RECONSTRUCT WITH
10' D.I.P. SEWER
* QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY AND ARE PROVIDED TO ASSIST THE CITY IN
DETERMINING FEE & BOND AMOUNTS ONLY.
* * THE CONTRACTOR SHALL VERIFY ALL QUANTITIES PRIOR TO START OF CONSTRUCTION.
INDEX MAP
XDENOTES SEE SHEET NO.
QUANTITIES
2 EA.
712 L.F.
1 EA.
358 LRA
285 LF. &
8 EA.
1 EA.
257 L.F.
3" MAX. SIZE NATIVE
SOIL COMPACTED 95%
6' MIN.
10" MAX.
6" MAX. SIZE
NATIVE SOIL --
COMPACTED 907o
1/2' CRUSHED STONE BEDDING
PER STD. SPECS. FOR PUBLIC
WORKS CONSTRUCTION TABLE
200 1.2 [A) SHOWN
8'
DWG.2506
1293
6" MIN.
10" MAX.
1' MAX. SIZE
SELECTED NATIVE
TO
ED90% COMPACTED
UTILITY NOTIFICATIONS
CITY OF FONTANA
PACIFIC BELL CO.
ATTN: CARLOS NAVARRO
ATTN: VIRGINIA BECKER
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5467
SOUTHERN CALIFORNIA GAS COMPANY
UNDERGROUND SERVICE ALERT
ATTN. DENNIS FREEMAN
(800) 422-4133
1981 W. LUGONIA AVE.
0-15
REDLANDS, CA. 92374
COMCAST (CABLE TV)
(909) 335-7547
ATTN: JACK HAYES
EMERGENCIES: (800) 427-2200
1205 DUPONT AVE.
h
ONTARIO, CA 91761
SOUTHERN CALIFORNIA EDISON COMPANY
(909) 390-4738
300 N. PEPPER STREET
ADDRESS: 310 S. MAPLE ST., SLE. D
RIALTO, CA 92376
GENERAL TELEPHONE CO.
(909) 820-5598 -- UNDERGROUND
ATTN: STEVE HOCK
(909) 875-5100 -- TRANSMISSION
1400 E. PHILLIPS BLVD.
(213) 637-1233 -- PIPELINES
ONTARIO, CA. 91766
SCALE: 1' = 100'
(800) 422-4133
CRAWFORD CANYON MUTUAL WATER CO.
FONTANA WATER COMPANY
ATTN: BILL VANDERKIEFT, JR.
(619) 868-6040
ATTN: MICHAEL J. MCGRAW
8440 NUEVO AVE.
FONTANA, CA. 92235
DATE:
SEPTEMBER 17, 2003
(909) 822-2201
FAX (909) 823-5046
PRIVATE ENGINEER'S NOTES TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR ANY STRUCTURES SHOWN ON THESE
PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES
TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND
RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR AGREES THAT HE/ SHE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT
THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE CITY, THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR
LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
BASIS OF BEARINGS
THE BEARING OF N 89'58'10" W FOR THE CENTERUNE OF FOXWORTH STREET, AS SHOWN ON A MAP OF TRACT NO. 14293,
RECORDED IN BOOK 255, PAGES 94-98, INCLUSIVE, OF MAPS, RECORDS OF SAN BERNARDINO COUNTY, CALIFORNIA, WAS
USED AS THE BASIS OF BEARINGS FOR THIS MAP.
BENCHMARK
CITY OF FONTANA BENCHMARK NO. 378, CIRCUIT NO. 67-5, 30D NAIL IN POWER POLE (NO NUMBER), SOUTHWEST CORNER
OF BEECH AND FOOTHILL BLVD., DATED SEPTEMBER 1967.
ELEVATION = 1267.84'
3" MAX. SIZE NATIVE
SOIL COMPACTED 95%
6' MIN.
10' MAX.
i N
6" MAX. SIZE - --
NATIVE SOIL
COMPACTED 90%
f.I
8" VCP
Fd -
TYPICAL BEDDING FOR 8" VCP/DIP
10' OR DEEPER
NOT TO SCALE
6" MIN.
10" MAX.
1' MAX. SIZE
SELECTED NATIVE
BEDDING COMPACTED
TO 90%
_Iz
wro
`i o
CL
d -
TYPICAL BEDDING FOR S" VCP/DIP
LESS THAN 10' DEEP
NOT TO SCALE
TAELE :
200 -12 [A]
SIEVE SIZE
PERCENTAGE PASSING SIEVES
1-1/2"
-
1'
-
3/4'
100
1/2'
90 - 100
3/8'
20 - 60
NO.4
0-15
NO,8
0-5
ASTM C 131 TEST GRADING
a
tvoHTti
FESS/p
QRO L Nql
����.�'� R99�FyCOMMENCE
<-D N0. 29616,
�
Exp. 3/31/a7
��q c / �,�P
lF OA V 0¢
CA1 �E
p
DIAL Two WORKING
BEFORE »�� DAYS BEF❑RE
YOU DIG YOU DIG
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGRI]UND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE
ENGR.
CI
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
BASELINE
CITY OF FONTANA, CALIFORNIA
AVE
0�
s A I
a -os -o
MLR
Al
h
�C�
ADDRESS: 310 S. MAPLE ST., SLE. D
A lE
�' PROJECT
SITE
SEWER PLAN - ACT 16250
TITLE �IE
/
SCALE: 1' = 100'
COR A, CA 2880
TELEPHONE: (9 ) 272 10 2 FAX: (909) 272-0166
FOOTHILL
AVE
DESIGNED BY:
DATE:
SEPTEMBER 17, 2003
29616 e
SIGNATURE RCE ATE
VICINITY MAP
NOT TO SCALE
PREPARED BY
FESS/p
QRO L Nql
����.�'� R99�FyCOMMENCE
<-D N0. 29616,
�
Exp. 3/31/a7
��q c / �,�P
lF OA V 0¢
CA1 �E
p
DIAL Two WORKING
BEFORE »�� DAYS BEF❑RE
YOU DIG YOU DIG
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGRI]UND SERVICE ALERT
REV.
REVISION DESCRIPTION
DATE
ENGR.
CI
DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
STANDARDS IN EFFECT.
Prepared Under The Supervision Of :
Date :
CITY OF FONTANA, CALIFORNIA
FIRM:
r2tab engineering, inc.
0�
s A I
a -os -o
MLR
ADDRESS: 310 S. MAPLE ST., SLE. D
DRAWN BY:
SEWER PLAN - ACT 16250
TITLE �IE
/
SCALE: 1' = 100'
COR A, CA 2880
TELEPHONE: (9 ) 272 10 2 FAX: (909) 272-0166
DESIGNED BY:
DATE:
SEPTEMBER 17, 2003
29616 e
SIGNATURE RCE ATE
CHECKED 8Y:
APP 0 BY:
/0 _ C
DRAWING NO.: 1
3375 3
C TY ENGINEEfZ DATE: